Plan Review Details - Permit 17060685
| Plan Review Stops For Permit 17060685 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-09-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-01 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-01 |
Time |
11:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-08 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-08 |
Time |
10:44 |
Sent To |
|
|
| Notes |
| 2017-07-08 10:47:19 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE DEMENSIONS FOR PRE-FABRICATED GATES. | | | 2. ALL SUBMITTAL DOCUMENTS SHALL BE IN DUPLICATE. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-09-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-01 |
Time |
11:46 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-28 |
Time |
13:34 |
Sent To |
|
|
| Notes |
| 2017-08-29 13:35:13 | RESUB ROUTED TO ESCHNEIDER VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-07-08 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-08 |
Time |
10:44 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-14 |
Time |
11:05 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-09-01 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-09-01 |
Time |
10:36 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2017-09-01 |
Time |
10:36 |
Sent To |
B |
|
| Notes |
| 2017-08-29 16:43:12 | ROUTED TO ERIC SCHNEIDER |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-08 |
Time |
10:44 |
Rev Time |
0.50 |
| Received By |
eschneid |
Date |
2017-06-27 |
Time |
15:18 |
Sent To |
B |
|
| Notes |
| 2017-06-27 15:19:02 | FAILED | | | | | | PLEASE PROVIDE WRITTEN RESPONSES. | | | | | | 1) PROVIDE THE WIDTH OF THE DUMPSTER ENCLOSURE OPENING | | | ON THE PLAN. IT MUST CONTAIN A MINIMUM 12 FOOT 6 INCH | | | WIDE OPENING (NO DIMENSION PROVIDED). | | | | | | 2) THE OVERALL DUMPSTER ENCLOSURE DEPTH DOES NOT MEET | | | CITY STANDARDS. PROVIDE A LETTER FROM THE CITY?S | | | SANITATION DEPARTMENT THAT THE 10 FOOT DEPTH MEETS IS | | | APPROVED. | | | | | | 3) SECTION 94-221(D)(10) OF THE ZONING AND LAND | | | DEVELOPMENT REGULATIONS REQUIRES THAT DUMPSTERS FOR | | | FOOD SERVICE BUSINESSES SHALL BE FULLY ENCLOSED AND | | | AIR-CONDITIONED. THE CHIEF BUILDING OFFICIAL DETERMINED | | | THAT AIR-CONDITIONING THE DUMPSTER ENCLOSURE WOULD NOT | | | COMPLY WITH THE ENERGY CODE REQUIREMENTS, SO THE | | | DUMPSTER DOES NOT NEED TO BE AIR-CONDITIONED. HOWEVER, | | | THE FULLY ENCLOSED DUMPSTER NEEDS TO HAVE SOME SORT OF | | | EXHAUST FAN. PROVIDE THE DETAILS ON HOW THE ENCLOSURE | | | WILL BE VENTED. PLEASE NOTE THAT THE FAN (MECHANICAL | | | EQUIPMENT) SHALL BE SCREENED IN ACCORDANCE WITH SECTION | | | 94-221(D)(8). THE NOTE ON THE PLAN TO REFERENCE THE | | | MASTER PERMIT DOES NOT APPLY SINCE NOTHING RELATING TO | | | THE DUMPSTER ENCLOSURE WAS APPROVED AS PART OF THE | | | MASTER BUILDING PERMIT BY ZONING. ALL DUMPSTER | | | ENCLOSURE DETAILS AND SPECIFICATIONS ARE TO BE INCLUDED | | | AND APPROVED BY THIS PERMIT. | | | | | | 4) PROVIDE TWO COPIES OF ALL PLANS. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446 | | | [email protected] | | | | | 2017-06-15 14:26:31 | ROUTED TO ERIC SCHNEIDER |
|
|
|