Plan Review Details - Permit 17060677
| Plan Review Stops For Permit 17060677 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-03 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-03 |
Time |
13:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-03 |
Time |
13:02 |
Sent To |
|
|
| Notes |
| 2017-08-03 13:05:05 | PROVISO | | | | | | NO REVISION REQUIRED TO BE SUBMTITED TO BUILDING | | | DIVISION UNLESS REQUESTED BY THE INSPECTOR | | | | | | FBC BUILDING 1609, PROVIDE A DETAIL OR SPECIFICATION | | | FOR ATTACHMENT OF THE MECHANICAL UNIT TO THE CURB. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-02 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-02 |
Time |
11:37 |
Sent To |
|
|
| Notes |
| 2017-08-02 11:47:29 | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | COMMENT FROM PREVIOUS LISTS: | | | | | | 2) SEMI-COMPLIED. FOR ALL ROOF TOP EQUIPMENT, PLEASE | | | PROVIDE THE DETAIL FOR THE ATTACHMENT FROM THE ROOF | | | STAND TO THE EQUIPMENT ABOVE. | | | 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 3RD REVIEW - PLAN WAS NOT REVISED. RESPONSE LETTER | | | PROVIDES A DESCRIPTION OF A DETAIL (APPEARS TO BE | | | 7-A5.01, ALREADY ON PLAN), AND AT THE END OF THE | | | DESCRIPTION STATES "THE UNIT WILL BE CONNECTED TO THE | | | NEW SUPPORT STEEL USING 1/2' STAINLESS STEEL BOLTS." | | | RESPONSE LETTER ALSO REFERS TO ATTACHED PRODUCT SHEET. | | | | | | COMMENT #2 REQUESTS "A DETAIL FOR ATTACHMENT FROM THE | | | ROOF STAND TO THE EQUIPMENT ABOVE". THE PRODUCT SHEET | | | CANNOT BE USED TO SPECIFY ATTACHMENT (NOT SIGNED AND | | | SEALED, NO WIND DESIGN CRITERIA, LACKS FASTENING | | | SPECIFICATION. | | | | | | THE RESPONSE LETTER DOES NOT ADDRESS THE COMMENT; 1/2" | | | STAINLESS STEEL BOLTS IS TOO GENERAL AND THE RESPONSE | | | LETTER IS NOT RETAINED AS A PART OF THE PERMIT | | | DOCUMENTS. | | | | | | EITHER A SEPARATE DETAIL CAN BE PROVIDED, OR THE DETAIL | | | ON THE PLAN CAN BE MODIFIED TO INCLUDE THE | | | SPECIFICATION. | | | | | | PLEASE REVISE PLAN TO INCLUDE THE INFORMATION | | | REQUESTED; ALSO INCLUDE INFORMATION SUCH AS NUMBER | | | REQUIRED, OR FASTENING PATTERN AS APPLICABLE, DIAMETER, | | | LENGTH. | | | | | | THIS MAY BE A PROVISO ITEM UPON REQUEST. PLANS HAVE | | | BEEN STAMPED. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | SAMANTHA HILL | | | (FOR JAMES A. WITMER BN, PX, CBO) | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6724 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-07-14 |
Time |
15:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-07-14 |
Time |
14:05 |
Sent To |
|
|
| Notes |
| 2017-07-14 15:52:06 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17060677 | | | ADD: 2218 S. DIXIE HWY. | | | CONT: BEELINE BUILDING CORP. | | | TEL: 561-254-6779 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: FRI. JULY 14, 2017 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) SEMI-COMPLIED. FOR ALL ROOF TOP EQUIPMENT, PLEASE | | | PROVIDE THE DETAIL FOR THE ATTACHMENT FROM THE ROOF | | | STAND TO THE EQUIPMENT ABOVE. | | | 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 3-6) COMPLIED. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-23 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-23 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2017-06-23 11:37:04 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17060677 | | | ADD: 2218 S. DIXIE HWY. | | | CONT: BEELINE BUILDING CORP. | | | TEL: 561-254-6779 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: FRI. JUNE 23, 2017 | | | ACTION: DENIED | | | | | | 1) THERE IS A DISCREPANCY IN THE PLANS. SHEET A3.01 | | | INDICATES A NEW ROOF TOP UNIT WHEREAS THE MECHANICAL | | | SHEET M3.01 INDICATES THE REPLACEMENT OF (2) 6 TON ROOF | | | TOP UNITS AND THE REPLACEMENT OF AN EXISTING 15 TON | | | ROOF TOP UNIT. WHEN WE VIEW THIS PROPERTY WITH EITHER | | | THE PALM BEACH COUNTY PROPERTY APPRAISERS AERIAL | | | PICTURES, OR THE COUNTY WIDE GIS/ GOOGLE, BING OR | | | PICTORIAL AERIAL PHOTOGRAPHS THERE ARE ONLY (2) ROOF | | | TOP UNITS. 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | | PLEASE CORRECT PLANS TO DEPICT AN ACCURATE ACCOUNTING | | | OF EXISTING ROOF TOP UNITS. | | | | | | 2) FOR THE NEW ROOF TOP UNIT, THE PLANS WILL NEED TO | | | PROVIDE DETAILS FOR THE TYPE OF ROOF FRAMING, WOOD | | | TRUSSES, METAL BAR JOIST AND OR CONCRETE T SYSTEM OR | | | TWIN T SYSTEMS, TYPE OF ROOF DECK AND THE REQUIRED | | | FRAMING AROUND THE NEW ROOF PENETRATION, AND ATTACHMENT | | | OF ROOF TOP CURB TO THE ROOF FRAMING SYSTEM AS WELL AS | | | THE NEW RTU TO THE CURB. | | | FOR ALL ROOF TOP EQUIPMENT, CURBS OR A/C STANDS, | | | DETAILED ATTACHMENT TO THE ROOF FRAMING & DECK AS WELL | | | AS FROM THE CURB OR ROOF STAND TO THE EQUIPMENT ABOVE. | | | | | | 2014 FBC-B 1604.4 ANALYSIS. LOAD EFFECTS ON STRUCTURAL | | | MEMBERS AND THEIR CONNECTIONS SHALL BE DETERMINED BY | | | METHODS OF STRUCTURAL ANALYSIS THAT TAKE INTO ACCOUNT | | | EQUILIBRIUM, GENERAL STABILITY, GEOMETRIC COMPATIBILITY | | | AND BOTH SHORT- AND LONG-TERM MATERIAL PROPERTIES. | | | EVERY STRUCTURE SHALL BE DESIGNED TO RESIST THE | | | OVERTURNING EFFECTS CAUSED BY THE LATERAL FORCES | | | SPECIFIED IN THIS CHAPTER. SEE SECTION 1609 FOR WIND | | | LOADS. | | | | | | 3) FOR THE 2 REPLACEMENT ROOF TOP UNITS, PLEASE PROVIDE | | | IF THE EXISTING CURB IS TO BE USED, IF EITHER A NEW | | | CURB OR CURB ADAPTOR WILL BE REQUIRED, AND PROVIDE THE | | | ANCHORING SYSTEM FOR THE CURB ADAPTOR AND THE ANCHORS | | | REQUIRED TO ANCHOR THE REPLACEMENT RTU, UNITS. 2014 | | | FBC-B 1604.4 ANALYSIS. 2014 FBC-M- 301.15 WIND | | | RESISTANCE. MECHANICAL EQUIPMENT, APPLIANCES AND | | | SUPPORTS THAT ARE EXPOSED TO WIND SHALL BE DESIGNED AND | | | INSTALLED TO RESIST THE WIND PRESSURES DETERMINED IN | | | ACCORDANCE WITH THE FLORIDA BUILDING CODE, BUILDING. | | | | | | 4) NEITHER THE ARCHITECTURAL SHEETS NOR MECHANICAL | | | SHEETS PROVIDE THE WIND DESIGN CRITERIA FOR THE NEW | | | ROOF TOP & REPLACEMENT RTU UNITS. 2014 FBC-B 1603.1.4 | | | WIND DESIGN DATA. | | | | | | 5) PLEASE NOTE EXISTING ROOF TOP UNITS ARE BEING | | | REPLACED AND NEW ROOF TOP UNITS, PLEASE SHOW COMPLIANCE | | | WITH: | | | 2014 FBC-B 1013.6 MECHANICAL EQUIPMENT. GUARDS SHALL BE | | | PROVIDED WHERE APPLIANCES, EQUIPMENT, FANS, ROOF HATCH | | | OPENINGS OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE | | | LOCATED WITHIN 10 FEET (3048 MM) OF A ROOF EDGE OR OPEN | | | SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS | | | LOCATED MORE THAN 30 INCHES (762 MM) ABOVE THE FLOOR, | | | ROOF OR GRADE BELOW. THE GUARD SHALL BE CONSTRUCTED SO | | | AS TO PREVENT THE PASSAGE OF A SPHERE 21 INCHES (533 | | | MM) IN DIAMETER. THE GUARD SHALL EXTEND NOT LESS THAN | | | 30 INCHES (762 MM) BEYOND EACH END OF SUCH APPLIANCE, | | | EQUIPMENT, FAN OR COMPONENT. | | | | | | 6) FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS | | | WHICH ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE | | | REVIEWED AND APPROVED IN WRITING BY THE DESIGNER OF | | | RECORD PRIOR TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. | | | FL 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-07-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-28 |
Time |
10:02 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-28 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-21 |
Time |
14:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-21 |
Time |
14:27 |
Sent To |
|
|
| Notes |
| 2017-07-21 15:01:39 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS (2ND REVIEW): | | | | | | 1. LIGHTING PLAN SHOWS 1 OFFICE AND 2 BATHROOMS WITH | | | OCCUPANCY SENSORS, BUT NO OTHER AREAS SHOW THE REQUIRED | | | CONTROL. THE MECHANICAL ROOM HAS A STANDARD SWITCH, AND | | | THE SALES AREAS SAY THAT THEY ARE TO BE CONNECTED TO | | | LCP, BUT NO DETAIL IS PROVIDED FOR LCP AND NO OCCUPANCY | | | SENSORS ARE SHOWN ON PLAN. CLARIFY AND/OR CORRECT. FBC | | | 107.2.1, C405.2.2 | | | 2. SHOW LOCATION OF PANEL MDP ON POWER PLAN. FBC | | | 107.2.1 | | | 3. AHU-1 IS BEING FED FROM PANEL AC AND IS SHOWN ON A | | | 20 AMP BREAKER WITH #12 WIRE. SPECS FROM THE MECHANICAL | | | PLAN STATE THAT THE MINIMUM CIRCUIT AMPACITY FOR THIS | | | IS 79 AMPS AND THE MAXIMUM OVER CURRENT PROTECTION | | | (OCP) IS SHOWN AS 80 AMP. PROVIDE CORRECTION. NEC | | | 110.3, 310.15(B)(16), 440.22(C), FBC 107.2.1 | | | 4. LOAD CALCULATION FOR PANEL AC DOES NOT INCLUDE THE | | | ACCURATE LOAD FOR AHU-1. IT ALSO SHOWS THE MOTOR LOAD | | | AT 100% INSTEAD OF THE REQUIRED 125%. PROVIDE | | | CORRECTION AND UPDATE PANEL AC AND PANEL C WITH THIS | | | INFORMATION. IT APPEARS THAT PANEL AC OCP AND POSSIBLY | | | PANEL C WILL BE OVERLOADED WHEN THIS IS INCLUDED. MAKE | | | ANY ADJUSTMENTS TO EQUIPMENT OR OCP AS NEEDED. FBC | | | 107.2.1, NEC 220, 215.2, 215.3, 408.30 | | | 5. RISER DIAGRAM NEEDS TO BE COMPLETE WITH ALL WIRE | | | SIZES TO CONFIRM CODE COMPLIANCE. VERIFYING WIRE AT | | | LATER DATE IS NOT ACCEPTABLE. PROVIDE CORRECTION. NEC | | | 215.5, FBC 107.2.1 | | | 6. RISER DIAGRAM STATES THAT THE ESTIMATED FAULT | | | CURRENT IS 21,000, WHICH MATCHES THE RATING OF PANEL | | | MDP. THE CALCULATION PROVIDED STATES THAT THE FAULT | | | CURRENT IS 23,192, WHICH IS IN EXCESS OF THE RATING OF | | | PANEL MDP. PROVIDE LETTER FROM POWER COMPANY WITH | | | ACCURATE FAULT CURRENT, ADJUST EQUIPMENT AS NECESSARY. | | | NEC 110.9, 110.10 | | | 7. PROVIDE ACCURATE LOAD CALCULATION FOR PANEL A, | | | SEVERAL LOADS ARE MISSING/NOT INCLUDED. SIZE EQUIPMENT | | | AND OCP AS NEEDED. NEC 220, 215.2, 215.3, 408.30 | | | 8. PROVIDE LOAD CALCULATION FOR ENTIRE SERVICE TO | | | CONFIRM THAT THE SERVICE IS NOT OVERLOADED. WHILE THE | | | OTHER SPACE IS STATED AS BEING VACANT, IF IT IS USED IN | | | THE FUTURE THIS COULD BE A PROBLEM. OUT OF THE | | | AVAILABLE 400 AMP SERVICE, APPROXIMATELY 300 AMPS ARE | | | REQUIRED FOR THIS TENANT. PROVIDE FULL LOAD | | | CALCULATION, UPGRADE SERVICE IF NECESSARY. NEC 220, | | | 230.31, FBC 107.2.1 | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-06-22 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-06-22 |
Time |
18:07 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-06-22 |
Time |
17:59 |
Sent To |
|
|
| Notes |
| 2017-06-22 18:06:52 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | FBC- 107.3.5.3 ? ELECTRIC SERVICE RISER WITH WIRE | | | SIZES, CONDUIT DETAIL AND GROUNDING DETAIL. COMPLETE | | | LOAD CALCULATIONS, PANEL SCHEDULES AND SHOW CIRCUITS ON | | | FLOOR PLAN. | | | | | | C405.2 LIGHTING CONTROLS (MANDATORY). | | | LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS | | | SPECIFIED IN SECTIONS C405.2.1, C405.2.2, C405.2.3 AND | | | C405.2.4. | | | | | | C405.2.1 MANUAL LIGHTING CONTROLS. | | | ALL BUILDINGS SHALL INCLUDE MANUAL LIGHTING CONTROLS | | | THAT MEET THE REQUIREMENTS OF SECTIONS C405.2.1.1 AND | | | C405.2.1.2. | | | | | | C405.2.1.1 INTERIOR LIGHTING CONTROLS. | | | EACH AREA ENCLOSED BY WALLS OR FLOOR-TO-CEILING | | | PARTITIONS SHALL HAVE AT LEAST ONE MANUAL CONTROL FOR | | | THE LIGHTING SERVING THAT AREA. THE REQUIRED CONTROLS | | | SHALL BE LOCATED WITHIN THE AREA SERVED BY THE CONTROLS | | | OR BE A REMOTE SWITCH THAT IDENTIFIES THE LIGHTS SERVED | | | AND INDICATES THEIR STATUS. | | | | | | C405.2.2.2 OCCUPANCY SENSORS. | | | OCCUPANCY SENSORS SHALL BE INSTALLED IN ALL CLASSROOMS, | | | CONFERENCE/MEETING ROOMS, EMPLOYEE LUNCH AND BREAK | | | ROOMS, PRIVATE OFFICES, RESTROOMS, STORAGE ROOMS AND | | | JANITORIAL CLOSETS, AND OTHER SPACES 300 SQUARE FEET | | | (28 M2) OR LESS ENCLOSED BY FLOOR-TO-CEILING HEIGHT | | | PARTITIONS. THESE AUTOMATIC CONTROL DEVICES SHALL BE | | | INSTALLED TO AUTOMATICALLY TURN OFF LIGHTS WITHIN 30 | | | MINUTES OF ALL OCCUPANTS LEAVING THE SPACE, AND SHALL | | | EITHER BE MANUAL ON OR SHALL BE CONTROLLED TO | | | AUTOMATICALLY TURN THE LIGHTING ON TO NOT MORE THAN 50 | | | PERCENT POWER. | | | | | | EXCEPTION: FULL AUTOMATIC-ON CONTROLS SHALL BE | | | PERMITTED TO CONTROL LIGHTING IN PUBLIC CORRIDORS, | | | STAIRWAYS, RESTROOMS, PRIMARY BUILDING ENTRANCE AREAS | | | AND LOBBIES, AND AREAS WHERE MANUAL-ON OPERATION WOULD | | | ENDANGER THE SAFETY OR SECURITY OF THE ROOM OR BUILDING | | | OCCUPANTS | | | | | | NO OUTLETS SHOWN ON DRAWINGS | | | | | | FAULT CURRENT CALCULATION REQUIRED PER 110.21 | | | | | | A/C EQUIPMENT SHOWN BUT NO ELECTRIC. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-07-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-07-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-07-17 |
Time |
13:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-06-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-19 |
Time |
13:04 |
Sent To |
|
|
| Notes |
| 2017-06-19 14:06:13 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET A 3.01 - ON THE WAY TO THE FRONT EXIT DOOR, | | | THERE IS A SPACE TO GO THROUGH BETWEEN DISPLAY 8 & 6 ON | | | THE DIAGONAL. THE DIMENSION OF THIS DIAGONAL SPACE IS | | | NOT INDICATED AND SHALL MEET THE MINIMUM REQUIREMENTS | | | OF THE CODE. | | | | | | NFPA 101 CHAPTER 7 MEANS OF EGRESS | | | | | | 7.3.4 MINIMUM WIDTH. | | | 7.3.4.1 THE WIDTH OF ANY MEANS OF EGRESS, UNLESS | | | OTHERWISE PROVIDED IN 7.3.4.1.1 THROUGH 7.3.4.1.3, | | | SHALL BE AS FOLLOWS: | | | (1) NOT LESS THAN THAT REQUIRED FOR A GIVEN EGRESS | | | COMPONENT IN THIS CHAPTER OR CHAPTERS 11 THROUGH 43 | | | (2) NOT LESS THAN 36 IN. (915 MM) WHERE ANOTHER PART OF | | | THIS CHAPTER AND CHAPTERS 11 THROUGH 43 DO NOT SPECIFY | | | A MINIMUM WIDTH | | | | | | | | | NFPA 101 CHAPTER 36, NEW MERCANTILE | | | | | | 36.2.5.5 REQUIRED AISLES SHALL BE NOT LESS THAN 36 IN. | | | (915 MM) INCLEAR WIDTH. | | | | | | | | | PLEASE PROVIDE THE APPLICABLE DIMENSION AND ENSURE THAT | | | IT MEETS THE MINIMUM REQUIRMENTS AT ALL TIMES. | | | | | | | | | | | | | | | 2) SHEET A 3.01 - THERE IS A NEW DOOR INDICATED LEADING | | | TO THE VESTIBULE. THERE IS NO DOOR SCHEDULE FOR THIS | | | DOOR INCLUDING, BUT NOT LIMITED TO, EXIT HARDWARE. ALL | | | OTHER DOORS ARE ALSO NOT ACCOUNTED FOR ON A DOOR | | | SCHEDULE. | | | | | | 36.2.2.2 DOORS. | | | 36.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE | | | PERMITTED. | | | 36.2.2.2.2* LOCKS COMPLYING WITH 7.2.1.5.5 SHALL BE | | | PERMITTED ONLY ON PRINCIPAL ENTRANCE/EXIT DOORS. | | | | | | 7.2.1 DOOR OPENINGS. | | | 7.2.1.1 GENERAL. | | | 7.2.1.1.1 A DOOR ASSEMBLY IN A MEANS OF EGRESS SHALL | | | CONFORM TO THE GENERAL REQUIREMENTS OF SECTION 7.1 AND | | | TO THE SPECIAL REQUIREMENTS OF 7.2.1. | | | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES. | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS | | | OCCUPIED. | | | 7.2.1.5.2* THE REQUIREMENT OF 7.2.1.5.1 SHALL NOT APPLY | | | TO DOOR LEAVES OF LISTED FIRE DOOR ASSEMBLIES AFTER | | | EXPOSURE TO ELEVATED TEMPERATURE IN ACCORDANCE WITH THE | | | LISTING, BASED ON LABORATORY FIRE TEST PROCEDURES. | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | | OPERATION FROM THE EGRESS SIDE. | | | 7.2.1.5.4 THE REQUIREMENTS OF 7.2.1.5.1 AND 7.2.1.5.3 | | | SHALL NOT APPLY WHERE OTHERWISE PROVIDED IN CHAPTERS 18 | | | THROUGH 23. | | | | | | | | | PLEASE REIVEW AND PROVIDE A DETAILED DOOR SCHEDULE. | | | | | | | | | 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-02 |
Time |
11:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-26 |
Time |
16:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-21 |
Time |
15:01 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-10 |
Time |
10:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-23 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-14 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-06-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-23 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-23 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-08-01 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-01 |
Time |
12:45 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-01 |
Time |
12:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-07-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-19 |
Time |
17:32 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-19 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2017-07-19 17:44:54 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17060677 | | | 7/19/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) AS PREVIOUSLY REQUESTED PLEASE PROVIDE AN AHRI | | | CERTIICATE FOR THE NEW 15 TON SYSTEM- SECTION C101.4.7 | | | FBC-14 ENERGY CONSERVATION. | | | | | | 2) SHEET M1.01: THE O/A INTAKE OPENING FOR THE | | | MECHANCIAL ROOM IS NOT IN COMPLIANCE WITH SECTION 401.4 | | | (2) WHICH SPECIFIES A MINIMUM 10' CLEARANCE DISTANCE | | | FROM THE PARKING LOT AREA. | | | | | | 3) M1.01: THE 9" FLEX DUCT SUPPLYING THE TWO 250 CFM | | | DIFFUSERS OVER THE DISPLAY BOX 2 AREA IS UNDERSIZED AT | | | 1.0 W.G PRESSURE. PLEASE UPSIZE THE DUCT TO MINIMUM 10" | | | DIAMETER. | | | | | | 4) M2.01: PLEASE ADD THE 0.6 CFM/SF CALCULATION TO THE | | | TORAL REQUIRED CFMS OF O/A FOR THE SHOWROOM- TABLE | | | 403.3. | | | | | | 4) A5.01: INDICATE HOW THE CONDENSER WILL BE ANCHORED | | | TO THE NEW SUPPORT STEEL- SECTION 301.15. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-21 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-21 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2017-06-21 13:25:20 | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING, ENERGY | | | CONSERVATION CODES. | | | PERMIT #17060677 | | | 6/21/17 | | | | | | 1) SUBMIT TWO COPIES OF THE DEVELOPMENT SERVICES | | | DEPARTMENT AC CHANGEOUT FORM FOR THE REPLACED 15-TON | | | AIR HANDLER AND THE TWO 6-TON CONDENSER UNITS. | | | | | | 2) REFER TO SECTION C101.4.7 EXCEPTIONS FBC-14 ENERGY | | | CONSERVATION: MATCHING SYSTEMS ARE REQUIRED FOR | | | REPLACEMENT OF THE 15-TON SYSTEM AND THE MATCH MUST BE | | | VERIFIED BY ANYONE OF THE FOLLOWING MEANS: A) AHRI | | | CERTIFICATE B) ACCREDITTED LABORATORY C) MANUFACTURER'S | | | LETTER D) LETTER FROM A FL. REGISTERED PROFESSIONAL | | | ENGINEER. | | | | | | 3) MECHANICAL PLAN M3.01: PROVIDE AN AC EQUIPMENT | | | SCHEDULE ON THE PLAN. | | | | | | 4) M3.01: INDICATE THE TYPE OF RETURN AIR DOOR TO BE | | | INSTALLED AT THE MECHANICAL/ELECTRICAL ROOM. PLEASE | | | NOTE THAT THE DOOR SHALL BE NON-COMBUSTIBLE PER SECTION | | | C403.2.7.2 FBC-14 ENERGY CONSERVATION, AND SECTION 602 | | | FBC-14 MECHANICAL. PLEASE REVIEW ALL SUB-SECTIONS OF | | | SECTION 602 FOR ALL MATERIALS ALLOWED TO BE IN THE | | | PLENUM INCLUDING ELECTRICAL EQUIPMENT AND WIRING, FOAM | | | PLASTIC ETC. PLEASE NOTE THAT NO FUEL-FIRED APPLIANCES | | | OR EQUIPMENT ARE PERMITTED TO BE LOCATED IN THE ROOM- | | | SECTION 602.1. | | | | | | 5) M3.01: REFER TO SECTION 606.2.1 FBC-14 MECHANICAL | | | AND SHOW THE LOCATION(S) OF THE REQUIRED SMOKE | | | DETECTOR(S) IN THE MECHANICAL ROOM. | | | | | | 6) M3.01: REFER TO SECTION 809.2 FBC-14 EXISTING | | | BUILDING CODE AND PROVIDE MINIMUM VENTILATION | | | CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE 403.3 | | | FBC-14 MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES | | | THE REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 7) A3.01 & M3.01: THE TWO NEW OFFICES 102, AND | | | EXECUTIVE OFFICE102 ROOMS BEING CREATED WILL REQUIRE | | | RETURN AIR TO ACHIEVE BALANCED AIR FOR THE SYSTEM- | | | SECTION 601.5. PLEASE PROVIDE DETAILS AND INDICATE THE | | | AMOUNT OF SUPPLY CFMS AT EACH DIFFUSER LOCATION IN THE | | | NEW ROOMS. IT MAY BE HELPFUL FOR THE DESIGN | | | PROFESSIONAL TO ASSIGN DIFFERENT ROOM NUMBERS TO EACH | | | OF THE THREE OFFICES. | | | | | | 8) M3.01: PROVIDE EXHAUST VENTILATION FOR THE NEW | | | TOILET ROOMS- TAVBLE 403.3. | | | | | | 9) SHOW THE LOCATIONS OF THE NEW 6-TON CONDENSERS AND | | | PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION- SECTION | | | 301.15 FBC-14 MECHANICAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-20 |
Time |
16:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-20 |
Time |
13:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-23 |
Time |
07:17 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-21 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2017-06-23 07:25:42 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE DETAILED SCOPE OF PLUMBING WORK THE | | | RISERS ON THE PLUMBING PAGE ARE UNCLEAR TWO OF THE | | | RISERS ARE LABELED NEW ADA BATH BUT NO NEW BATHROOM IS | | | SHOWN ON THE FLOOR PLAN. ANOTHER RISER SHOWS TWO NEW | | | LAVS BUT NONE SHOWN ON FLOOR PLAN PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 2. ANY NEW SINKS INCLUDING BREAKROOM SINKS SHALL COMPLY | | | WITH. FBC ACC 606.2 AND 606.3 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|