Plan Review Details - Permit 17060666
| Plan Review Stops For Permit 17060666 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-03-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-24 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-24 |
Time |
10:42 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-05 |
Time |
11:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-01-04 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2018-01-05 11:52:52 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SEPERATE PERMIT REQUIRED FOR CABANA. NO REVIEW | | | PERFORMED ON CABANA AT THIS TIME. THIS REVIEW (2ND) IS | | | FOR THE MAIN RESIDENCE ONLY. THE VALUE MAY BE | | | PROPORTIONED BETWEEN STRUCTURES. | | | 2. PALM BEACH COUNTY IMPACT FEES REQUIRED. | | | 3. PROVIDE SITE DRAINAGE PLAN. | | | 4. PLANS FOR CONCRETE FLOOR SYSTEM TO BE SIGNED AND | | | SEALED BY DESIGN PROFESSIONAL. | | | 5. PROVISO - SHORING ENGINEER TO INSPECT AND APPROVE IN | | | WRITING THE SHORING OF ELEVATED DECK. | | | 6. ENERGY SUBMITTAL INCLUDES INFORMATION FOR BOTH | | | STRUCTURES. A SEPERATE ENERGY SUBMITTAL IS REQUIRED FOR | | | EACH STRUCTURE. | | | 7. NOA 15-0122.04 FOR HARDIE PLANK HAS EXPIRED. PROVIDE | | | CURRENT NOA. | | | 8. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS FOR | | | BBQ GRILL. | | | 9. STATE FINISHED FLOOR ELEVATION ON PLANS. | | | 10. SITE PLAN SHOWS PROPERTY IS LOCATED ON CORTEZ ROAD. | | | PROPERTY IS LOCATED ON POTTER ROAD. | | | 11. SELECT ICYNENE PRODUCT TO ACHIEVE THE R-30 RATING. | | | MANUFACTURERS INSTALLATION INSTRUCTIONS TO BE ON-SITE | | | AT TIME OF INSTALLATION/INSPECTION. | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | | | | FBC R401.3 SITE DRAINAGE | | | PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING | | | COMPLIANCE WITH FBC R401.3 DRAINAGE. | | | SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER | | | CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT | | | DOES NOT CREATE A HAZARD. | | | LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM | | | FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6 | | | INCHES WITHIN THE FIRST 10 FEET. | | | EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER | | | PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10 | | | FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE | | | DRAINAGE AWAY FROM THE STRUCTURE. | | | IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING | | | FOUNDATION SHALL BE SLOPED A MINIMUM OF | | | 2 PERCENT AWAY FROM THE BUILDING. | | | | | | PLANS THAT HAVE BEEN PREPARED BY AN ENGINEER AND | | | SUBMITTED FOR PUBLIC RECORD SHALL BEAR THE SIGNATURE, | | | DATE AND SEAL OF THE ENGINEER PER FL ADMIN. CODE RULE | | | 61G15-23.001. | | | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | _ OR _ | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | | | | R401.3 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD | | | (MANDATORY). | | | THE BUILDING OFFICIAL SHALL REQUIRE THAT AN ENERGY | | | PERFORMANCE LEVEL (EPL) DISPLAY CARD BE COMPLETED AND | | | CERTIFIED BY THE BUILDER TO BE ACCURATE AND CORRECT | | | BEFORE FINAL APPROVAL OF THE BUILDING FOR OCCUPANCY. | | | FLORIDA LAW [SECTION 553.9085, FLORIDA STATUTES)] | | | REQUIRES THE EPL DISPLAY CARD TO BE INCLUDED AS AN | | | ADDENDUM TO EACH SALES CONTRACT FOR BOTH PRESOLD AND | | | NON-PRESOLD RESIDENTIAL BUILDINGS. THE EPL DISPLAY CARD | | | CONTAINS INFORMATION INDICATING THE ENERGY PERFORMANCE | | | LEVEL AND EFFICIENCIES OF COMPONENTS INSTALLED IN A | | | DWELLING UNIT. THE BUILDING OFFICIAL SHALL VERIFY THAT | | | THE EPL DISPLAY CARD COMPLETED AND SIGNED BY THE | | | BUILDER ACCURATELY REFLECTS THE PLANS AND | | | SPECIFICATIONS SUBMITTED TO DEMONSTRATE CODE COMPLIANCE | | | FOR THE BUILDING. A COPY OF THE EPL DISPLAY CARD CAN BE | | | FOUND IN APPENDIX C. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-19 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-19 |
Time |
11:29 |
Sent To |
M |
|
| Notes |
| 2017-07-19 17:01:45 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. SEPERATE PERMIT REQUIRED FOR DETACHED GARAGE. | | | SEPERATE PLANS NOT REQUIRED. THE FOLLOWING COMMENTS ARE | | | FOR THE MAIN RESIDENCE ONLY. | | | 2. IMPACT FEES REQUIRED. | | | 3. PROVIDE SITE DRAINAGE PLAN. | | | 4. DESIGN CRITERIA ON PLAN PAGE 2 OF 7 REFERENCES THE | | | 2010 FBC. CURRENT CODE IS 2014 FBC 5TH ED. | | | 5. PROVIDE SHOP DRAWINGS, SIGNED AND SEALED BY DESIGN | | | PROFESSIONAL FOR PRE-ENGINEERED CONCRETE FLOOR SYSTEM. | | | 6. PROVIDE ICC-ES REPORT (ESR-1826) FOR PROPOSED | | | ICYNENE INSULATION. DESIGNER TO SELECT SYSTEM TO BE | | | USED. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTION | | | ON-SITE AT TIME OF INSPECTION. | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. | | | | | | FBC-110.7 IMPACT OF CONSTRUCTION. NEW CONSTRUCTION | | | ACTIVITY SHALL NOT ADVERSELY IMPACT LEGAL HISTORIC | | | SURFACE WATER DRAINAGE FLOWS SERVING ADJACENT | | | PROPERTIES, AND MAY REQUIRE SPECIAL DRAINAGE DESIGN | | | COMPLYING WITH ENGINEERING STANDARDS TO PRESERVE THE | | | POSITIVE DRAINAGE PATTERNS OF THE AFFECTED SITES. | | | SUPPLY A DRAINAGE DESIGN | | | | | | GOVERNING CODES | | | 2014 FLORIDA BUILDING CODE 5TH ED W/2010 WEST PALM | | | BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER | | | 1 ADMINISTRATION | | | | | | R402.1.1 INSULATION AND FENESTRATION CRITERIA. | | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | | REQUIREMENTS OF TABLE R402.1.1 BASED ON THE CLIMATE | | | ZONE SPECIFIED IN CHAPTER 3. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY | | | REVIEWED SHEETS DETACHED AND MARK VOID. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-03-15 |
Time |
13:23 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-03-15 |
Time |
12:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-01-03 |
Time |
15:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-01-03 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2018-01-03 15:53:55 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: PREVIOUS COMMENT NOT | | | ADDRESSED SATISFACTORILY HAVE FURTHER COMMENTS IN | | | PARENTHESES. COMMENTS CORRECTED ARE NOTED. | | | | | | 1. CORRECTED. | | | 2. CORRECTED. | | | 3. #6 GROUNDING ELECTRODE CONDUCTOR SHOWN FROM PANEL B | | | TO CWP IS INCORRECT IN SIZE AND LOCATION. GEC MUST BE | | | SIZED PER NEC 250.66. ADDITIONALLY, ALL GROUNDING | | | ELECTRODES PRESENT MUST BE BONDED TOGETHER, NOT JUST | | | THE CWP. NEC 250.50; FBC RE3608.1 (GROUNDING ELECTRODE | | | SYSTEM IS ESTABLISHED AT THE MAIN SERVICE, WHICH IS | | | LOCATED ON THE SIDE OF THE GARAGE. THE ONLY OTHER | | | LOCATION FOR A GROUNDING ELECTRODE WOULD BE AT A | | | SEPARATE STRUCTURE. PROVIDE CORRECTION.) | | | 4. PROVIDE FEEDER INFORMATION, WIRE AND BREAKER SIZE | | | FOR PANEL C. NEC 215.5 (NOT PROVIDED. ADDITIONALLY, NO | | | LOAD FOR PANEL C IS SHOWN IN THE PANEL SCHEDULE FOR | | | PANEL B. PROVIDE CORRECTION.) | | | 5. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. NEC 250.94; FBC RE3609.3 (NOT SHOWN ON PLAN.) | | | 6. CORRECTED. | | | 7. CORRECTED. | | | 8. CORRECTED. | | | 9. CORRECTED. | | | 10. GARAGE BUILDING, 2ND FLOOR BEDROOM DOES NOT SHOW A | | | SMOKE ALARM. ADDITIONALLY, THE COMBO SMOKE/CO ALARM IS | | | REQUIRED TO BE WITHIN 10 FEET OF BEDROOM. ADDITIONALLY, | | | A SMOKE ALARM IS REQUIRED ON EACH LEVEL OF THE BUILDING | | | AND THERE IS NOT ONE SHOWN ON 1ST FLOOR PLAN. PROVIDE | | | CORRECTION. FBC R314, R315 (NOT PROVIDED, A NOTE IS NOT | | | SUFFICIENT.) | | | 11. GARAGE BUILDING, BEDROOM CLOSET SHOWS A RECESS | | | LIGHT. LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS | | | AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE | | | PERMITTED IN CLOSETS. PROVIDE CORRECTION. NEC | | | 410.16(B), FBC RE4003.12 (STATING THAT LED LIGHTS WILL | | | BE USED IS NOT SUFFICIENT AS MANY LED LIGHTS HAVE OPEN | | | BULBS. PROVIDE CORRECTION AS PREVIOUSLY REQUESTED.) | | | 12. MASTER CLOSETS SHOW RECESS LIGHTS. LIGHTING WITH | | | OPEN OR PARTIALLY ENCLOSED LAMPS AND PENDANT LUMINAIRES | | | OR LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOSETS. | | | PROVIDE CORRECTION. NEC 410.16(B), FBC RE4003.12 | | | (STATING THAT LED LIGHTS WILL BE USED IS NOT SUFFICIENT | | | AS MANY LED LIGHTS HAVE OPEN BULBS. PROVIDE CORRECTION | | | AS PREVIOUSLY REQUESTED.) | | | 13. MASTER BATH SHOWS A RECESS LIGHT ABOVE TUB. | | | LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE SUITABLE | | | FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC 410.10(A), | | | FBC RE4003.11 (CORRECTION NOT PROVIDED. LIGHTING ABOVE | | | TUB MUST BE VAPOR ROOF. PROVIDE AS REQUESTED.) | | | 14. OUTDOOR RECESS LIGHTS IN PORCH AND COVERED WALKWAY | | | AREAS ARE REQUIRED TO BE SUITABLE FOR DAMP LOCATIONS. | | | PROVIDE NOTE TO COMPLY. NEC 410.10(A), FBC RE4003.11 | | | (NOT PROVIDED.) | | | | | | NEW COMMENTS: | | | 15. NOTE UNDER RECESS LIGHTS STATES THAT 50% OF | | | LIGHTING SHALL BE HIGH EFFICIENCY. PROVIDE COMPLIANCE: | | | "A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY | | | INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY | | | LAMPS OR A MINIMUM OF 75 PERCENT OF THE PERMANENTLY | | | INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH | | | EFFICACY LAMPS". A NOTE WILL SUFFICE. FBC EC R404.1 | | | 16. PLEASE BE ADVISED THAT SOME OF THE COMMENTS HAVE | | | NOT BEEN ADDRESSED FOR TWO REVIEWS. IF UPON THE THIRD | | | REVIEW, IF IT IS NECESSARY TO REJECT THE SUBMITTED PLAN | | | A THIRD TIME FOR THE SAME REASONS, AN ADDITIONAL PLAN | | | REVIEW IS REQUIRED. FLORIDA STATUTES STATE: ?WITH | | | RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. FS 553.80(2)(B)? | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-30 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-30 |
Time |
08:05 |
Sent To |
|
|
| Notes |
| 2017-06-30 09:15:44 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: | | | | | | 1. PROVIDE GROUNDING ELECTRODE SYSTEM FOR MAIN HOUSE AS | | | REQUIRED FOR A BUILDING OR STRUCTURE SUPPLIED BY A | | | FEEDER OR BRANCH CIRCUIT. NEC 250.32; FBC RE3607.3 | | | 2. #6 GROUNDING ELECTRODE CONDUCTOR SHOWN FROM PANEL A | | | TO CWP IS INCORRECT IN SIZE AND LOCATION. ALL GROUNDING | | | ELECTRODE CONDUCTORS MUST ATTACH TO THE GROUNDED | | | SERVICE CONDUCTOR ON THE SUPPLY SIDE OF THE SERVICE AND | | | SHALL BE SIZED PER NEC 250.66. NEC 250.64(D)(3); FBC | | | RE3607.1 | | | 3. #6 GROUNDING ELECTRODE CONDUCTOR SHOWN FROM PANEL B | | | TO CWP IS INCORRECT IN SIZE. GEC MUST BE SIZED PER NEC | | | 250.66. ADDITIONALLY, ALL GROUNDING ELECTRODES PRESENT | | | MUST BE BONDED TOGETHER, NOT JUST THE CWP. SEE COMMENT | | | #1 ALSO. NEC 250.50; FBC RE3608.1 | | | 4. PROVIDE FEEDER INFORMATION, WIRE AND BREAKER SIZE | | | FOR PANEL C. NEC 215.5 | | | 5. PROVIDE INTERSYSTEM BONDING TERMINATION POINT AT | | | SERVICE. NEC 250.94; FBC RE3609.3 | | | 6. PANEL B, CIRCUITS 2,4 AND 6,8 AND 10,12 SHOW A #6 | | | ROMEX WIRE ON A 60 AMP BREAKER. #6 WIRE IS NOT RATED | | | FOR 60 AMPS. PROVIDE CORRECTION. NEC 334.80; FBC | | | RE3705.4.4 | | | 7. PANEL C, CIRCUIT 2,4 SHOW A #6 ROMEX WIRE ON A 60 | | | AMP BREAKER. #6 WIRE IS NOT RATED FOR 60 AMPS. PROVIDE | | | CORRECTION. NEC 334.80; FBC RE3705.4.4 | | | 8. NOTE ON RISER DIAGRAM STATES "PER 2008 NEC". CORRECT | | | TO CURRENT CODE, 2011 NEC. FBC PREFACE | | | 9. PROVIDE 20 AMP CIRCUIT FOR BATH GFCI OUTLETS. A | | | MINIMUM OF ONE 20 AMPERE BRANCH CIRCUIT SHALL BE | | | PROVIDED TO SUPPLY BATHROOM RECEPTACLE OUTLET(S). SUCH | | | CIRCUITS SHALL HAVE NO OTHER OUTLETS. NEC 210.11(C)(3) | | | , FBC RE3703.4 | | | 10. GARAGE BUILDING, 2ND FLOOR BEDROOM DOES NOT SHOW A | | | SMOKE ALARM. ADDITIONALLY, THE COMBO SMOKE/CO ALARM IS | | | REQUIRED TO BE WITHIN 10 FEET OF BEDROOM. ADDITIONALLY, | | | A SMOKE ALARM IS REQUIRED ON EACH LEVEL OF THE BUILDING | | | AND THERE IS NOT ONE SHOWN ON 1ST FLOOR PLAN. PROVIDE | | | CORRECTION. FBC R314, R315 | | | 11. GARAGE BUILDING, BEDROOM CLOSET SHOWS A RECESS | | | LIGHT. LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS | | | AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE | | | PERMITTED IN CLOSETS. PROVIDE CORRECTION. NEC | | | 410.16(B), FBC RE4003.12 | | | 12. MASTER CLOSETS SHOW RECESS LIGHTS. LIGHTING WITH | | | OPEN OR PARTIALLY ENCLOSED LAMPS AND PENDANT LUMINAIRES | | | OR LAMPHOLDERS SHALL NOT BE PERMITTED IN CLOSETS. | | | PROVIDE CORRECTION. NEC 410.16(B), FBC RE4003.12 | | | 13. MASTER BATH SHOWS A RECESS LIGHT ABOVE TUB. | | | LIGHTING IN BATHTUB OR SHOWER AREAS SHALL BE SUITABLE | | | FOR DAMP LOCATIONS. PROVIDE CORRECTION. NEC 410.10(A), | | | FBC RE4003.11 | | | 14. OUTDOOR RECESS LIGHTS IN PORCH AND COVERED WALKWAY | | | AREAS ARE REQUIRED TO BE SUITABLE FOR DAMP LOCATIONS. | | | PROVIDE NOTE TO COMPLY. NEC 410.10(A), FBC RE4003.11 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-05 |
Time |
13:39 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-05 |
Time |
13:39 |
Sent To |
|
|
| Notes |
| 2017-07-05 13:40:36 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT IS REQUIRED FOR THE GAS INSTALLATION. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-03-26 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-02-20 |
Time |
14:29 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-01-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-01-23 |
Time |
14:39 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-12-15 |
Time |
17:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-07-20 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-06-14 |
Time |
12:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
P |
Date |
2018-03-24 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-24 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-24 |
Time |
10:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-01-05 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-01-04 |
Time |
10:28 |
Sent To |
|
|
| Notes |
| 2018-01-05 11:23:06 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-07-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-19 |
Time |
16:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-19 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2017-07-19 16:37:51 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-03-26 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-03-26 |
Time |
10:40 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-03-26 |
Time |
09:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2018-01-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-01-23 |
Time |
14:38 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-01-23 |
Time |
14:34 |
Sent To |
I |
|
| Notes |
| 2018-01-23 14:38:21 | PLAN DENIED | | | ENERGY CALCULATIONS AND PLAN DO NOT MATCH | | | CFM AND SEER. REFER TO SECTION | | | 107 FBC 2014. | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-07-20 |
Time |
15:04 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-07-20 |
Time |
13:11 |
Sent To |
|
|
| Notes |
| 2017-07-20 15:04:08 | PASS PROVISO | | | 1) REFER TO SECTION M1602.4 BALANCED RETURN AIR | | | 2014RESIDENTIAL CODE | | | 2) REFER TO SECTION 403.2.4 AIR HANDLER UNITS | | | 2014 FLORIDA ENERGY CODE | | | | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-03-16 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-03-16 |
Time |
17:10 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-03-16 |
Time |
17:10 |
Sent To |
|
|
| Notes |
| 2018-03-16 17:12:12 | 03/16/18 APPROVED BY PLUMBING AND PUT BACK IN R41, LAC |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-01-11 |
|
|
Cont ID |
|
| Sent By |
thunt |
Date |
2018-01-11 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
thunt |
Date |
2018-01-11 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2018-01-11 15:22:11 | PROVISO APPROVAL: PROVIDE A CODE COMPLIANT SANITARY | | | RISER DRAWING |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-05 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-05 |
Time |
09:45 |
Sent To |
|
|
| Notes |
| 2017-07-05 12:02:50 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1.THE ENERGY CALCULATIONS SHOW A PROPANE TANKLESS | | | HEATER OR IS IT A NATURAL GAS PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 2. THE SOIL STACK FOR SECOND FLOOR IN MAIN HOUSE SHALL | | | CONNECT TO BUILDING DRAIN DOWN STREAM OF THE BATHROOM | | | GROUP. PER FBC RES P3108.1 | | | | | | 3. A CLEAN OUT IS REQUIRED AT THE BASE OF EVERY SOIL | | | STACK. PER FBC RES P3005.2.6 | | | | | | 4. THE LAUNDRY SINK AND WASHING MACHINE IN MAIN HOUSE | | | SHALL BE SHOWN ON THE RISER CONNECTED TO SECOND FLOOR | | | PIPING. PER FBC RES P3108.1 | | | | | | 5. THE KITCHEN SINK IN THE OUTDOOR KITCHEN SHALL | | | CONNECT DOWN STREAM OF THE BATHROOM. PER FBC RES | | | P3108.1 | | | | | | 6. THE LAV IN THE DOWN STAIRS BATHROOM IN DETACHED | | | GARAGE IS NIT VENTED. PER FBC RES P3101.2.1 | | | | | | 7. THE WASHING MACHINE UPSTAIRS IN THE DETACHED GARAGE | | | IS NOT SHOWN ON THE RISER DIAGRAM PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 8. ISLAND SINK UPSTAIRS IN DETACHED GARAGE SHALL | | | CONNECT DOWN STREAM OF THE BATHROOM GROUP. PER FBC RES | | | P3108.1 | | | | | | 9. PROVIDE ACCESS TO THE SHUT OFF VALVES FOR STACKABLE | | | WASHING MACHINES . PER FBC RES P2903.9.3 | | | | | | 10. PLEASE SHOW LOCATION OF WATER HEATERS. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2017-07-19 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-19 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-19 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2017-07-19 16:38:50 | ROOF PERMIT REQUIRED. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2018-03-02 |
|
|
Cont ID |
|
| Sent By |
awooten |
Date |
2018-03-02 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-03-02 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2018-01-18 |
|
|
Cont ID |
|
| Sent By |
AW |
Date |
2018-01-18 |
Time |
16:04 |
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2018-01-18 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-01-18 16:04:37 | ***********************************ZONING REVIEW | | | FAILED********************************** | | | | | | 1. ADDITIONAL/SEPARATE PERMITS ARE REQUIRED FOR FENCES, | | | POOLS, POOL EQUIPMENT, LANDSCAPE, | | | IRRIGATION AND DRIVEWAY | | | | | | 2. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES. AS PER SECTION | | | 94-305(B)(4) OF THE ZONING CODE ("ZLDR"): MECHANICAL | | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | | REQUIRED SETBACK. | | | | | | 3. FOR LANDSCAPING YOU HAVE TWO OPTIONS, YOU CAN SUBMIT | | | A SEPARATE LANDSCAPE PERMIT AND IRRIGATION PLAN WITH | | | TWO (2) COPIES OF A LANDSCAPE PLAN SHOWING COMPLIANCE | | | WITH SECTIONS 94-442 AND 94-445 OF THE ZLDR, OR YOU CAN | | | SUBMIT FOR A CONDITIONAL LANDSCAPE APPROVAL | | | APPLICATION, IN WHICH YOU WOULD HAVE TO SUBMIT FOR | | | LANDSCAPE PERMIT AND PASS THE FINAL LANDSCAPE | | | INSPECTION PRIOR TO ISSUSANCE OF CO. FOR THE | | | CONDITIONAL LANDSCAPE APPROVAL APPLICATION, PLEASE | | | CONTACT ME. | | | | | | GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY | | | DWELLING UNITS SHALL BE AS FOLLOWS: | | | | | | A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. | | | | | | | | | PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS. | | | | | | ALANA WOOTEN | | | PLANNING AND ZONING | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-07-17 |
|
|
Cont ID |
|
| Sent By |
nwira |
Date |
2017-07-17 |
Time |
16:11 |
Rev Time |
|
| Received By |
awooten |
Date |
2017-07-17 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-07-17 16:11:37 | ***********************************ZONING REVIEW | | | FAILED********************************** | | | | | | 1. ADDITIONAL/SEPARATE PERMITS ARE REQUIRED FOR FENCES, | | | POOLS, POOL EQUIPMENT, LANDSCAPE, | | | IRRIGATION AND DRIVEWAY | | | | | | 2. INDICATE SETBACK DIMENSIONS FROM PROPOSED A/C | | | EQUIPMENT TO ALL PROPERTY LINES. AS PER SECTION | | | 94-305(B)(4) OF THE ZONING CODE ("ZLDR"): MECHANICAL | | | EQUIPMENT MAY NOT PROJECT MORE THAN 4 FEET INTO A | | | REQUIRED SETBACK. | | | | | | 3. PLEASE SUBMIT A SEPARATE LANDSCAPE PERMIT AND | | | IRRIGATION PLAN WITH TWO (2) COPIES OF A LANDSCAPE PLAN | | | SHOWING COMPLIANCE WITH SECTIONS 94-442 AND 94-445 OF | | | THE ZLDR. | | | | | | GENERAL LANDSCAPING STANDARDS FOR SINGLE-FAMILY | | | DWELLING UNITS SHALL BE AS FOLLOWS: | | | | | | A. SINGLE-FAMILY DWELLING UNITS. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHADE, FLOWERING OR FRUIT | | | TREE SHALL BE PLANTED FOR EACH 1,200 SQUARE FEET OF | | | OPEN SPACE OR PORTION THEREOF. FOR SINGLE-FAMILY | | | DWELLING UNITS, AT LEAST ONE SHRUB SHALL BE PLANTED FOR | | | EACH 500 SQUARE FEET OF OPEN SPACE OR PORTION THEREOF. | | | | | | | | | PLEASE LET ME KNOW IF YOU HAVE ANY QUESTIONS. | | | | | | ALANA WOOTEN | | | PLANNING AND ZONING | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] | | | | | | | | | |
|
|
|