Plan Review Details - Permit 17060596
| Plan Review Stops For Permit 17060596 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-08-11 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-08-11 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-29 |
Time |
11:28 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-29 |
Time |
11:28 |
Sent To |
|
|
| Notes |
| 2017-06-29 11:28:19 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17060556 (MASTER) | | | TRAVELING TOGETHER 17060559, 17060562, 17060565, | | | 17060568, 17060571, | | | 17060574, 17060578, 17060581, 17060584, 17060587, | | | 17060590, 17060593, 17060596, 17060599, 17060602, | | | 17060605, 17060608, 17060611, 17060614 | | | | | | ADD: 410 EVERNIA ST. SUITE NUMBER 802 | | | CONT: URBAN TEAM CONSTRUCTION | | | TEL: 305-710-3886 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: THURS. JUNE 29/2017 | | | ACTION: DENIED | | | | | | 4X FEE NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B) | | | | | | | | | | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | | | | | | | 1) 2ND REQUEST THE VALUES STATED ARE EXTREMELY LOW FOR | | | THE VALUE STATED AND THE SCOPE OF WORK. 108.3 IS FOR | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER | | | ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, | | | PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE | | | WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD | | | AND PROFIT. | | | I?VE SPOKEN WITH THE CHIEF PLUMBING INSPECTOR AND FOR | | | THE REPLACEMENT OF T FIXTURES, REMOVAL, DISPOSAL, LABOR | | | TO BRING THE NEW FIXTURES TO THE TENANT UNIT, UNPACK | | | SET AND INSTALL NEW VALVES, SPOUT, HANDLES, SHOWER | | | HEADS, PLUS LABOR AND OVERHEAD A MINIMUM OF $2,500.00 | | | PER UNIT WOULD BE A MINIMUM VALUE WE WOULD ACCEPT WE | | | BELIEVE THE ACTUAL VALUE IS $3,500.00 PER UNIT. | | | IN REGARDS TO THE VALUE STATED FOR THE REMOVAL & | | | INSTALLATION OF LIGHT FIXTURES, THE $25.00 DOLLARS | | | STATED IS THE AVERAGE WAGE FOR AN ELECTRICIAN, NOT THE | | | VALUE THE CONTRACTOR CHARGES, THE RATE CHARGED CAN BE | | | AS HIGH AS $90.00 DEPENDING ON THE COMPLEXITY AND TYPE | | | OF JOB. WE WILL USE $75.00 FOR THE AVERAGE RATE FOR AN | | | ELECTRICIAN, PLEASE PROVIDE THE CUT SHEETS FOR | | | FIXTURES, COST OF THE FIXTURE AND BULB. . FOR | | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | | SHALL BE TOTAL REPLACEMENT PURPOSES, VALUATION OF | | | BUILDINGS AND SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, PLUMBING, | | | MECHANICAL, INTERIOR FINISHES, NORMAL SITE WORK | | | (EXCAVATION AND BACKFILL FOR BUILDINGS), ARCHITECTURAL | | | AND DESIGN FEES, MARKETING COST, OVERHEAD AND PROFIT. | | | | | | 1ST ROUND OF COMMENTS. FOR THE SCOPE OF WORK THE VALUE | | | OF THE PROJECT IS LOW. | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | 108.3* BUILDING PERMIT VALUATION. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER | | | ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, | | | PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE | | | WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD | | | AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION | | | REFERENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF | | | NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | | | | 2) COMPLIED. PLEASE PROVIDE A FLOOR PLAN OF THE FLOOR | | | FINISHES TO BE REPLACE AND WHAT FINISH MATERIALS. | | | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 3) 2ND REQUEST. SAME COMMENT AS THE 1ST REVIEW. THE | | | QUALIFIER OF THE COMPANY HAS TO TAKE OWNERSHIP OF THE | | | PLANS SUBMITTED UNLESS THE PLANS ARE DESIGNED BY EITHER | | | AN ARCHITECT UNDER F. S 481 OR AN ENGINEER UNDER F. S. | | | 471. | | | 1ST ROUND OF COMMENTS. THE AUTHOR (QUALIFIER OF | | | COMPANY) OF THE FLOOR PLAN IS TO PRINT THEIR NAME, SIGN | | | THEIR NAME AND PRINT THEIR LICENSE NUMBER OF THE PLANS | | | THEY DREW. 107.3.4 DESIGN PROFESSIONAL IN RESPONSIBLE | | | CHARGE. | | | 4) 2ND REQUEST. THE SUBMITTED SHAW SUNDRIES GROUND | | | WORKS ACOUSTICAL UNDERLAYMENT STYLE 074VS IS A SALES | | | BROCHURE LISTING TESTING, NOT THE ACTUAL TEST REPORTS. | | | SEE 1ST ROUND OF COMMENTS. | | | | | | 1ST ROUND OF COMMENTS. BLDG TYPE: TYPE I/ TYPE II FLOOR | | | INSULATION (FBC-B 2014) | | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | | | | 4A) 2ND REQUEST. FBC-B 2014 1207.3 STRUCTURE-BORNE | | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 4B) 2ND REQUEST. FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 4C) 2ND REQUEST. FLAME SPREAD- FBC-B 2014 603.1. | | | EXCEPTION 2. INSULATION INSTALLED BETWEEN A FINISHED | | | FLOOR AND SOLID DECKING WITHOUT INTERVENING AIRSPACE | | | SHALL BE ALLOWED TO HAVE A FLAME SPREAD INDEX OF NOT | | | MORE THAN 200. | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | THIS REVIEW CYCLE A THOROUGH REVIEW COULD NOT BE | | | COMPLETED AND ADDITIONAL AND OR NEW COMMENTS MAY OCCUR | | | ON SUBSEQUENT REVIEWS. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-22 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-22 |
Time |
15:47 |
Rev Time |
|
| Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2017-06-22 15:47:37 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17060556 (MASTER) | | | TRAVELING TOGETHER 17060559, 17060562, 17060565, | | | 17060568, 17060571, | | | 17060574, 17060578, 17060581, 17060584, 17060587, | | | 17060590, 17060593, 17060596, 17060599, 17060602, | | | 17060605, 17060608, 17060611, 17060614 | | | | | | ADD: 410 EVERNIA ST. SUITE NUMBER 802 | | | CONT: URBAN TEAM CONSTRUCTION | | | TEL: 305-710-3886 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: THURS. JUNE 22/2017 | | | ACTION: DENIED | | | | | | 1) FOR THE SCOPE OF WORK THE VALUE OF THE PROJECT IS | | | LOW. | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | 108.3* BUILDING PERMIT VALUATION. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER | | | ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS | | | AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, | | | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL | | | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, | | | PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE | | | WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD | | | AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION | | | REFERENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF | | | NATIONAL CONSTRUCTION COST ANALYSIS SERVICES | | | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS | | | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE | | | CONGRESS. | | | 2) PLEASE PROVIDE A FLOOR PLAN OF THE FLOOR FINISHES TO | | | BE REPLACE AND WHAT FINISH MATERIALS. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | 3) THE AUTHOR (QUALIFIER OF COMPANY) OF THE FLOOR PLAN | | | IS TO PRINT THEIR NAME, SIGN THEIR NAME AND PRINT THEIR | | | LICENSE NUMBER OF THE PLANS THEY DREW. 107.3.4 DESIGN | | | PROFESSIONAL IN RESPONSIBLE CHARGE. | | | 4) BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B | | | 2014) | | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | | LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH | | | CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | 4A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | 4B) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | 4C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2. | | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | 5) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | THIS REVIEW CYCLE A THOROUGH REVIEW COULD NOT BE | | | COMPLETED AND ADDITIONAL AND OR NEW COMMENTS MAY OCCUR | | | ON SUBSEQUENT REVIEWS. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-08-11 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-08-11 |
Time |
11:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-09 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-09 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2017-08-09 13:31:45 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ONLY ONE COPY OF PLAN WAS SUBMITTED. 2 COPIES ARE | | | REQUIRED. FBC 107.1 | | | 2. PER CONVERSATION WITH CONTRACTOR, THE PLAN SHOULD | | | STATE THAT ALL ELECTRICAL WORK IS EXISTING AND THEY | | | SCOPE OF WORK IS TO INSTALL LIGHT FIXTURES ONLY. FBC | | | 107.2.1 | | | 3. PLAN SHOWS 3 DIFFERENT MODELS, WHICH IS THE LAYOUT | | | FOR THIS UNIT? PROVIDE CORRECT LAYOUT AND REMOVE ANY | | | SHEETS THAT ARE IRRELEVANT. FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-05 |
Time |
14:53 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-05 |
Time |
14:53 |
Sent To |
|
|
| Notes |
| 2017-07-05 14:53:43 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL 2ND REVIEW COMMENTS: | | | | | | 1. PREVIOUS COMMENT NOT ADDRESSED: "NO ELECTRICAL PLAN | | | PROVIDED FOR REVIEW. PROVIDE PLAN SHOWING ALL | | | ELECTRICAL WORK". WITH EACH APPLICATION, THERE ARE | | | SEVERAL DIFFERENT FLOOR LAYOUTS. REMOVE ANY ITEMS NOT | | | RELATED TO THE UNIT IN QUESTION AND PROVIDE ELECTRICAL | | | PLAN SHOWING WHICH FIXTURES WILL BE | | | REMOVED/REPLACED/INSTALLED. ELECTRICAL PLAN IS REQUIRED | | | TO BE SIGNED BY A DESIGN PROFESSIONAL OR THE ELECTRICAL | | | CONTRACTOR QUALIFIER. FS 471.003(2)(H); 471.025; FBC | | | 107.3.5 | | | 2. PREVIOUS COMMENT NOT ADDRESSED: "PROVIDE COPY OF | | | CONTRACT SHOWING TOTAL COST OF JOB, TO INCLUDE LABOR | | | AND MATERIALS". PROVIDING AN UNSIGNED CONTRACT WITH A | | | PER FIXTURE PRICE IS NOT ACCEPTABLE. PROVIDE TOTAL | | | VALUE OF JOB FOR EACH UNIT, INCLUDING LABOR AND COST OF | | | FIXTURES. PROVIDE SPEC SHEET OF LIGHT FIXTURES. NEC | | | 110.3; FBC 109.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-21 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-21 |
Time |
08:55 |
Sent To |
|
|
| Notes |
| 2017-06-21 08:55:44 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: | | | | | | 1. NO ELECTRICAL PLAN PROVIDED FOR REVIEW. PROVIDE PLAN | | | SHOWING ALL ELECTRICAL WORK. FBC 107.3.5 | | | 2. PROVIDE COPY OF CONTRACT SHOWING TOTAL COST OF JOB, | | | TO INCLUDE LABOR AND MATERIALS. FBC 109.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-08-11 |
Time |
11:41 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-08-03 |
Time |
15:52 |
Sent To |
|
|
| Notes |
| 2017-08-04 15:53:01 | B27 | | | **TRAVELLING TOGETHER - 17060556, 17060559, 17060562, | | | 17060565, 17060568, 17060571, 17060574, 17060578, | | | 17060581, 17060584, 17060587, 17060590, 17060593, | | | 17060596, 17060599, 17060602, 17060605, 17060608, | | | 17060611, 17060614** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-07 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-23 |
Time |
15:28 |
Sent To |
|
|
| Notes |
| 2017-06-26 15:28:07 | B18 | | | **TRAVELLING TOGETHER - 17060556, 17060559, 17060562, | | | 17060565, 17060568, 17060571, 17060574, 17060578, | | | 17060581, 17060584, 17060587, 17060590, 17060593, | | | 17060596, 17060599, 17060602, 17060605, 17060608, | | | 17060611, 17060614** |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-13 |
Time |
12:46 |
Sent To |
|
|
| Notes |
| 2017-06-19 12:46:21 | B14 | | | **TRAVELLING TOGETHER - 17060556, 17060559, 17060562, | | | 17060565, 17060568, 17060571, 17060574, 17060578, | | | 17060581, 17060584, 17060587, 17060590, 17060593, | | | 17060596, 17060599, 17060602, 17060605, 17060608, | | | 17060611, 17060614** |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-08-11 |
Time |
11:40 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-08-11 |
Time |
11:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-07-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-07 |
Time |
16:27 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-07 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2017-07-07 16:27:11 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17060556 (MASTER) | | | TRAVELING TOGETHER 17060559, 17060562, 17060565, | | | 17060568, 17060571, | | | 17060574, 17060578, 17060581, 17060584, 17060587, | | | 17060590, 17060593, 17060596, 17060599, 17060602, | | | 17060605, 17060608, 17060611, 17060614 | | | | | | | | | 2NDREVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENT HAS NOT COMPLIED | | | | | | 2ND REQUEST1. PLEASE PROVIDE FLOOR PLAN AND INDICATE | | | PLUMBING WORK ON PLAN. PER WPB AMEND TO FBC 107.2.1 | | | PROVIDE SCOPE OF PLUMBING WORK WHICH SPECIFIC FIXTURES | | | ARE BEING REPLACED , SPECIFY UNIT | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-21 |
Time |
14:29 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-21 |
Time |
14:29 |
Sent To |
|
|
| Notes |
| 2017-06-21 14:29:36 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE FLOOR PLAN AND INDICATE PLUMBING WORK | | | ON PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|