Plan Review Details - Permit 17060518
Plan Review Stops For Permit 17060518
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-19 Cont ID  
Sent By jgomez Date 2017-06-19 Time 10:53 Rev Time 0.00
Received By jgomez Date 2017-06-19 Time 10:53 Sent To  
Notes
2017-06-19 11:01:18TALKED TO MONICA (CONTRACTOR) FOR CLARIFICATION OF
 SCOPE OF WORK. THIS APARTMENT IS LOCATED IN THE FIRST
 FLOOR. NO NEED FOR ACOUSTICAL INSTALLATION. THE SCOPE
 OF WORK IS FOR INSTALLATION OF CERAMIC TILE. JG.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-19 Cont ID  
Sent By cthroop Date 2017-06-19 Time 08:08 Rev Time 0.00
Received By cthroop Date 2017-06-19 Time 08:08 Sent To  
Notes
2017-06-19 08:20:04BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. IDENTIFY UNDERLAYMENT TO BE INSTALLED.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 2. PROVIDE TEST REPORTS FOR ASTM E-90, E-492 & E-84 FOR
 THE PROPOSED UNDERLAYMENT FOR THE EXISTING SITE
 CONDITIONS.
  
 FBC 603.1 FLAME SPREAD ? ASTM E-84
 FBC 1207.2 AIR-BORNE SOUND. ASTM E - 90-02
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
 FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E - 492-04
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 3. ALL SUBMITTAL DOCUMENTS SHALL BE IN DUPL;ICATE.
  
 FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF
 CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL
 INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL
 BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT
 APPLICATION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-06-19 Cont ID  
Sent By jgomez Date 2017-06-19 Time 10:53 Rev Time 0.00
Received By jgomez Date 2017-06-19 Time 10:51 Sent To  
Notes
2017-06-19 10:52:49TALKED TO MONICA (CONTRACTOR) FOR CLARIFICATION OF
 SCOPE OF WORK. THIS APARTMENT IS LOCATED IN THE FIRST
 FLOOR. NO NEED FOR ACOUSTICAL INSTALLATION. THE SCOPE
 OF WORK IS FOR INSTALLATION OF CERAMIC TILE. JG.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-06-19 Cont ID  
Sent By cthroop Date 2017-06-19 Time 08:08 Rev Time 0.00
Received By cthroop Date 2017-06-13 Time 09:30 Sent To  
Notes
2017-06-14 09:31:13BLDG <5K