| 2017-07-20 15:01:02 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17060287 |
| | ADD: 419 NORTHWOOD RD. |
| | CONT: FLAMINGO SIGNS |
| | TEL: 772-220-7377 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 2ND REVIEW |
| | DATE: THURS. JULY 20/ 2017 |
| | ACTION: DENIED |
| | |
| | 1) THE 1ST REVIEW THE SIGN WAS A HAND PAINTED SIGN. |
| | THIS REVIEW THE LETTERS ARE SHOWN TO BE ? INCH THICK |
| | FLAT CUT PVC LETTERS. THE ANCHORING DESIGN HAS NOT |
| | GIVEN THE WIND DESIGN CRITERIA THESE LETTERS WERE |
| | DESIGNED TO? |
| | |
| | 2014 FBC-B 1603.1.4 WIND DESIGN DATA. THE FOLLOWING |
| | INFORMATION RELATED TO WIND LOADS SHALL BE SHOWN, |
| | REGARDLESS OF WHETHER WIND LOADS GOVERN THE DESIGN OF |
| | THE LATERAL FORCE-RESISTING SYSTEM OF THE STRUCTURE: |
| | |
| | 1.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), |
| | MILES PER HOUR AND NOMINAL DESIGN WIND SPEED, VASD, AS |
| | DETERMINED IN ACCORDANCE WITH SECTION 1609.3.1. |
| | |
| | 1.2. RISK CATEGORY. |
| | |
| | 1.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE |
| | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. |
| | HEIGHT AND EXPOSURE. |
| | |
| | 1.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. |
| | |
| | 1.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR |
| | COMPONENTS AND CLADDING MATERIALS NOT SPECIFICALLY |
| | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL |
| | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF. |
| | |
| | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & |
| | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE |
| | BUILDING. |
| | |
| | 2) THE CUT SECTION OF WALL DOES NOT GIVE THE TYPE OF |
| | STRUCTURE/ MATERIALS THIS DESIGN IS TO BE INSTALLED/ |
| | 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 3) THE CUT SECTION FOR THE LETTERS DOES NOT INDICATE |
| | WHAT MATERIAL THE ANCHORING STUD IS, HOW THE ANCHORING |
| | STUD IS ATTACHED TO THE PVC LETTERS, THE DIAMETER OF |
| | THE MATERIAL AND HOW MANY ANCHORS ARE REQUIRED FOR EACH |
| | LETTER. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 4) THE CUT SECTION FOR THE LETTERS DOES NOT INDICATE |
| | WHAT MATERIAL THE RECTANGLE IS AROUND THE LETTERS, , |
| | HOW THE ANCHORING STUD IS ATTACHED TO THE PVC RECTANGLE |
| | SURROUND, THE DIAMETER OF THE MATERIAL AND HOW MANY |
| | ANCHORS ARE REQUIRED FOR EACH LETTER. 107.2.1.3 |
| | ADDITIONAL INFORMATION IS REQUIRED. |
| | |
| | 5) THE APPLICATION WILL NEED TO BE AMENDED SINCE THE |
| | DESCRIPTION OF WORK STILL STATES A HAND PAINTED SIGN. |
| | 105.1 PERMIT AND REQUIRED INFORMATION. |
| | |
| | 6) THE ORIGINAL VALUE OF THE HAND PAINTED SIGN WAS |
| | $1,500.00 IN VALUE. THE CONTRACTOR WILL ALSO NEED TO |
| | AMEND THE VALUE, THERE IS A DEFINITE INCREASE IN THE |
| | VALUE OF THE PERMIT. |
| | |
| | 108.3* BUILDING PERMIT VALUATION. IF, IN THE OPINION OF |
| | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF |
| | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, |
| | MECHANICAL, OR PLUMBING SYSTEMS APPEARS TO BE UNDER |
| | ESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE |
| | DENIED. FOR PERMITTING PURPOSES, VALUATION OF BUILDINGS |
| | AND SYSTEMS SHALL BE TOTAL REPLACEMENT PURPOSES, |
| | VALUATION OF BUILDINGS AND SYSTEMS SHALL BE THE TOTAL |
| | REPLACEMENT VALUE TO INCLUDE STRUCTURAL, ELECTRICAL, |
| | PLUMBING, MECHANICAL, INTERIOR FINISHES, NORMAL SITE |
| | WORK (EXCAVATION AND BACKFILL FOR BUILDINGS), |
| | ARCHITECTURAL AND DESIGN FEES, MARKETING COST, OVERHEAD |
| | AND PROFIT; EXCLUDING ONLY LAND VALUE. VALUATION |
| | REFERENCES MAY INCLUDE THE LATEST PUBLISHED DATA OF |
| | NATIONAL CONSTRUCTION COST ANALYSIS SERVICES |
| | (MARSHALL-SWIFT, MEANS, ETC.) WITH REGIONAL ADJUSTMENTS |
| | FOR LOCATION AS PUBLISHED BY THE INTERNATIONAL CODE |
| | CONGRESS. |
| | |
| | 7) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |