Plan Review Details - Permit 17060236
Plan Review Stops For Permit 17060236
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-29 Cont ID  
Sent By shill Date 2017-06-29 Time 07:51 Rev Time 0.00
Received By shill Date 2017-06-29 Time 07:39 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-12 Cont ID  
Sent By shill Date 2017-06-12 Time 08:09 Rev Time 0.00
Received By shill Date 2017-06-12 Time 06:24 Sent To  
Notes
2017-06-12 08:09:33****CORRECTIONS****
 REVISED 6/23/17
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. SEE ENERGY CALCS; VERY LITTLE DATA IN THE DATA ENTRY
 REPORT - NO FLOOR, EXT. LIGHTING, WINDOWS, ROOF, DOORS,
 WALLS, ETC. CLARIFY OR REVISE, FBC 107.
  
 2. FBC B 1004, A-1.0, REVISE PROJECT INFORMATION TO
 INCLUDE SQUARE FOOT AREA FOR THIS SPACE, SQUARE FEET
 PER PERSON.
  
 3. FBC A 604.8.1, REVISE PLAN TO SHOW OVERALL SIZE OF
 ACCESSIBLE COMPARTMENT, FBC A FIGURE 604.8.1.6 SHOW
 TURNING RADIUS REQUIRED. PLAN APPEARS TO COMPLY; REVISE
 TO DEMONSTRATE COMPLIANCE AND FIELD REQUIREMENT.
  
 4. FBC A 604.8.1.2, THE TOILET COMPARTMENT DOOR IS TO
 BE SELF CLOSING, REVISE PLAN TO INDICATE REQUIREMENT.
  
 5. 6/23/17 - FBC COURSE - OK (RECEIVED VIA EMAIL,
 FORWARDED TO FBPE)
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-06-09 Cont ID  
Sent By jpearson Date 2017-06-09 Time 07:13 Rev Time 0.00
Received By jpearson Date 2017-06-09 Time 07:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-06-30 Cont ID  
Sent By pleduc Date 2017-06-30 Time   Rev Time 0.00
Received By pleduc Date 2017-06-30 Time 12:13 Sent To P
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-06-12 Cont ID  
Sent By pleduc Date 2017-06-12 Time   Rev Time 0.00
Received By pleduc Date 2017-06-12 Time 12:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-03 Cont ID  
Sent By gjohnson Date 2017-07-03 Time 15:44 Rev Time 0.00
Received By gjohnson Date 2017-06-27 Time 15:03 Sent To  
Notes
2017-06-28 15:03:52B08

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-06-13 Cont ID  
Sent By gjohnson Date 2017-06-13 Time 10:37 Rev Time 0.00
Received By gjohnson Date 2017-06-06 Time 14:09 Sent To  
Notes
2017-06-07 14:09:24B05

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2017-06-09 Cont ID  
Sent By ccole Date 2017-06-09 Time 15:58 Rev Time 0.00
Received By ccole Date 2017-06-09 Time 14:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-07-03 Cont ID  
Sent By gjohnson Date 2017-07-03 Time 15:44 Rev Time 0.00
Received By gjohnson Date 2017-06-30 Time 18:05 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-06-13 Cont ID  
Sent By gjohnson Date 2017-06-13 Time 10:32 Rev Time 0.00
Received By gjohnson Date 2017-06-13 Time 10:32 Sent To  
Notes
2017-06-13 10:37:111ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.5.1 SIDE
 WALL.
 THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM)
 LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM
 THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM
 FROM THE REAR WALL.
 604.5.2 REAR WALL.
 THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG
 MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER
 CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24
 INCHES (610 MM) MINIMUM ON THE OTHER SIDE.
  
 2. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND
 SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230
 MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO
 THE CENTERLINE OF THE DISPENSER. PER FBC ACC 604.7
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  