Plan Review Details - Permit 17060236
| Plan Review Stops For Permit 17060236 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-29 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-29 |
Time |
07:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-12 |
Time |
08:09 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-12 |
Time |
06:24 |
Sent To |
|
|
| Notes |
| 2017-06-12 08:09:33 | ****CORRECTIONS**** | | | REVISED 6/23/17 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. SEE ENERGY CALCS; VERY LITTLE DATA IN THE DATA ENTRY | | | REPORT - NO FLOOR, EXT. LIGHTING, WINDOWS, ROOF, DOORS, | | | WALLS, ETC. CLARIFY OR REVISE, FBC 107. | | | | | | 2. FBC B 1004, A-1.0, REVISE PROJECT INFORMATION TO | | | INCLUDE SQUARE FOOT AREA FOR THIS SPACE, SQUARE FEET | | | PER PERSON. | | | | | | 3. FBC A 604.8.1, REVISE PLAN TO SHOW OVERALL SIZE OF | | | ACCESSIBLE COMPARTMENT, FBC A FIGURE 604.8.1.6 SHOW | | | TURNING RADIUS REQUIRED. PLAN APPEARS TO COMPLY; REVISE | | | TO DEMONSTRATE COMPLIANCE AND FIELD REQUIREMENT. | | | | | | 4. FBC A 604.8.1.2, THE TOILET COMPARTMENT DOOR IS TO | | | BE SELF CLOSING, REVISE PLAN TO INDICATE REQUIREMENT. | | | | | | 5. 6/23/17 - FBC COURSE - OK (RECEIVED VIA EMAIL, | | | FORWARDED TO FBPE) | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-09 |
Time |
07:13 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-09 |
Time |
07:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-30 |
Time |
12:13 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-06-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-12 |
Time |
12:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-03 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-27 |
Time |
15:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-13 |
Time |
10:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-06 |
Time |
14:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-09 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-09 |
Time |
14:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-07-03 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-03 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-30 |
Time |
18:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-13 |
Time |
10:32 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-13 |
Time |
10:32 |
Sent To |
|
|
| Notes |
| 2017-06-13 10:37:11 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE SHOW COMPLIANCE WITH FBC ACC 604.5.1 SIDE | | | WALL. | | | THE SIDE WALL GRAB BAR SHALL BE 42 INCHES (1065 MM) | | | LONG MINIMUM, LOCATED 12 INCHES (305 MM) MAXIMUM FROM | | | THE REAR WALL AND EXTENDING 54 INCHES (1370 MM) MINIMUM | | | FROM THE REAR WALL. | | | 604.5.2 REAR WALL. | | | THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG | | | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER | | | CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 | | | INCHES (610 MM) MINIMUM ON THE OTHER SIDE. | | | | | | 2. TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. PER FBC ACC 604.7 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|