Plan Review Details - Permit 17060235
Plan Review Stops For Permit 17060235
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status N Date 2017-07-25 Cont ID  
Sent By ccole Date 2017-07-25 Time 08:29 Rev Time 0.00
Received By ccole Date 2017-07-25 Time 08:29 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-07-21 Cont ID  
Sent By jwitmer Date 2017-07-21 Time 08:49 Rev Time 0.00
Received By jwitmer Date 2017-07-21 Time 08:37 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-20 Cont ID  
Sent By jwitmer Date 2017-06-20 Time 09:00 Rev Time  
Received By jwitmer Date 2017-06-20 Time 07:45 Sent To  
Notes
2017-06-20 09:00:292014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17060235
 ADD: 480 HIBISCUS ST. SUITE: 104
 CONT: L. J. SHEEHAN INC.
 TEL: 561-223-2750
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 1ST REVIEW
 DATE: JUNE 20, 2017
 ACTION: DENIED
  
 1) SHEET A.001:
 1A) PLANS INDICATE THEY WERE DESIGNED UNDER THE 2014
 FBC-EXISTING BUILDING CODE, LEVEL II ALTERATION. PLEASE
 BE AWARE THE CITY HAS NEVER RECORDED A CERTIFICATE OF
 OCCUPANCY FOR THIS UNIT. A PERMIT WAS ISSUED IN 2008
 BUT NO INSPECTIONS WERE EVER SCHEDULED, THE PERMIT
 EXPIRED. THIS APPLIED FOR PERMIT APPLICATION IS STILL
 CONSIDERED NEW WORK UNDER THE 2014 FBC-B FOR NEW WORK!
 THE 2014 EXISTING BUILDING CODE SHOULD NOT BE
 REFERENCED SINCE THIS UNIT HAS NEVER HAD A CERTIFICATE
 OF OCCUPANCY ISSUED.
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 111.1 USE AND OCCUPANCY. NO BUILDING OR
 STRUCTURE SHALL BE USED OR OCCUPIED, AND NO CHANGE IN
 THE EXISTING OCCUPANCY CLASSIFICATION OF A BUILDING OR
 STRUCTURE OR PORTION THEREOF SHALL BE MADE, UNTIL THE
 BUILDING OFFICIAL HAS ISSUED A CERTIFICATE OF OCCUPANCY
 THEREFORE AS PROVIDED HEREIN. ISSUANCE OF A CERTIFICATE
 OF OCCUPANCY SHALL NOT BE CONSTRUED AS AN APPROVAL OF A
 VIOLATION OF THE PROVISIONS OF THIS CODE OR OF OTHER
 ORDINANCES OF THE JURISDICTION. SAID CERTIFICATE SHALL
 NOT BE ISSUED UNTIL ALL REQUIRED ELECTRICAL, GAS,
 MECHANICAL, PLUMBING AND FIRE PROTECTION SYSTEMS HAVE
 BEEN INSPECTED FOR
 COMPLIANCE WITH THE TECHNICAL CODES AND OTHER
 APPLICABLE LAWS AND ORDINANCES AND RELEASED BY THE
 BUILDING OFFICIAL.
  
 1B) CONSTRUCTION DATA LIST THIS PROJECT AS A BUSINESS
 OCCUPANCY PLEASE BE AWARE THAT THIS USAGE REFLECTS A
 MERCANTILE OCCUPANCY. 2014 FBC-B 309.1 MERCANTILE GROUP
 M. MERCANTILE GROUP M OCCUPANCY INCLUDES, AMONG OTHERS,
 THE USE OF A BUILDING OR STRUCTURE OR A PORTION
 THEREOF, FOR THE DISPLAY AND SALE OF MERCHANDISE AND
 INVOLVES STOCKS OF GOODS, WARES OR MERCHANDISE
 INCIDENTAL TO SUCH PURPOSES AND ACCESSIBLE TO THE
 PUBLIC.
  
 1C) CONSTRUCTION DATA DOES NOT PROVIDE THE OCCUPANT
 LOAD FOR THIS TENANT SPACE.
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR
 BUILDINGS.
 107.3.5.1 COMMERCIAL BUILDINGS:
 107.3.5.1.1 BUILDING
 (7) OCCUPANT LOADS
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-11-27 Cont ID  
Sent By ppetty Date 2017-11-27 Time 12:40 Rev Time 0.00
Received By ppetty Date 2017-11-27 Time 12:39 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-06-16 Cont ID  
Sent By jleahy Date 2017-06-16 Time 13:59 Rev Time 0.00
Received By jleahy Date 2017-06-16 Time 13:59 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-06-14 Cont ID  
Sent By pleduc Date 2017-06-14 Time   Rev Time 0.00
Received By pleduc Date 2017-06-13 Time 16:04 Sent To  
Notes
2017-06-14 10:23:54THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) ANY FIRE SPRINKLER WORK SHALL BE UNDER SEPARATE SHOP
 DRAWINGS BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
  
 2) ENSURE THAT THE EXISTING SYSTEM CAN PROTECT THE
 PROPOSED COMMODITY. A REVIEW BY A FIRE SPRINKLER
 PROFESSIONAL IS REQUIRED TO ENSURE CODE COMPLIANT
 PROTECTION.
  
  
 3) ENSURE THAT THE PROPOSED EQUIPMENT AND SHELVING DO
 NOT CREATE AN OBSTRUCTION TO FIRE SPRINKLER PROTECTION.
  
  
 4) ANY FIRE ALARM WORK SHALL BE UNDER SEPARATE SHOP
 DRAWINGS BY CERTIFIED LIFE SAFETY CONTRACTORS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2017-07-25 Time   Rev Time 0.00
Received By lmarchan Date 2017-07-21 Time 14:14 Sent To  
Notes
2017-07-24 14:14:42RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2017-07-21 Time   Rev Time 0.00
Received By lmarchan Date 2017-07-18 Time 13:05 Sent To  
Notes
2017-07-19 13:05:57RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2017-06-20 Time   Rev Time 0.00
Received By lmarchan Date 2017-06-07 Time 08:43 Sent To  
Notes
2017-06-09 08:43:58B25

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-06-20 Cont ID  
Sent By jwitmer Date 2017-06-20 Time 09:00 Rev Time  
Received By jwitmer Date 2017-06-20 Time 07:45 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-07-25 Cont ID  
Sent By ccole Date 2017-07-25 Time 08:25 Rev Time 0.00
Received By ccole Date 2017-07-25 Time 08:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-07-20 Cont ID  
Sent By ccole Date 2017-07-20 Time 10:09 Rev Time 0.00
Received By ccole Date 2017-07-20 Time 10:01 Sent To  
Notes
2017-07-20 10:13:282ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17060235
 7/20/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) A NON-COMBUSTIBLE LOUVERED DOOR IS REQUIRED FOR THE
 AC CLOSET, HOWEVER THE ARCHITECTURAL PLANS ARE
 INDICATING A WOOD DOOR- PLEASE SEE SECTION C403.2.7.2
 FBC-14 ENERGY CONSERVATION.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-06-20 Cont ID  
Sent By ccole Date 2017-06-20 Time 12:13 Rev Time 0.00
Received By ccole Date 2017-06-20 Time 11:59 Sent To  
Notes
2017-06-20 12:17:461ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17060235
 6/20/17
  
 PLAN REVIEW RESULT: DENIED.
  
 1) REFER TO SECTION C403.2.1 FBC-14 ENERGY CONSERVATION
 AND PROVIDE AC COOLING AND HEATING CALCULATIONS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-06-19 Cont ID  
Sent By gjohnson Date 2017-06-16 Time 08:56 Rev Time 0.00
Received By gjohnson Date 2017-06-16 Time 16:26 Sent To  
Notes
***NONE***