| Plan Review Stops For Permit 17060212 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-15 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-15 |
Time |
11:24 |
Sent To |
G |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-29 |
Time |
14:03 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-29 |
Time |
13:45 |
Sent To |
|
|
| Notes |
| 2017-06-29 14:10:27 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ROOFING PERMIT REQUIRED. | | | | | | 2. PROVIDE SHOP DRAWINGS OF PRE-ENGINEERED STAIRS. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | 3. PROVIDE ICC-ES REPORT AND MANUFACTURERS INSTALLATION | | | INSTRUCTION FOR THE PROPOSED INSULATION. DESIGNER TO | | | SELECT PRODUCT THAT WILL ACHEIVE THE PRESCRIPTIVE R-30 | | | LEVEL OF INSULATION. | | | | | | R402.1.1 INSULATION AND FENESTRATION CRITERIA. | | | THE BUILDING THERMAL ENVELOPE SHALL MEET THE | | | REQUIREMENTS OF TABLE R402.1.1 BASED ON THE CLIMATE | | | ZONE SPECIFIED IN CHAPTER 3. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-05-18 |
|
|
Cont ID |
|
| Sent By |
ppetty |
Date |
2018-05-18 |
Time |
08:51 |
Rev Time |
0.00 |
| Received By |
ppetty |
Date |
2018-05-18 |
Time |
08:45 |
Sent To |
|
|
| Notes |
| 2018-05-18 08:51:24 | FOUR TIMES FEE FOR PLAN REVIEW ADDED, SEE BELOW. | | | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | PLEASE READ COMMENTS IN THEIR ENTIRETY AND RESPOND TO | | | ALL ITEMS. | | | | | | 1 CORRECTED | | | 2. CORRECTED | | | 3. CORRECTED | | | 4. CORRECTED | | | 5. CORRECTED | | | 6 CORRECTED | | | 7. CORRECTED. | | | | | | SINCERELY, | | | PHIL PETTY | | | ELECTRICAL PLANS EXAMINER,CHIEF ELECTRICAL INSPECTOR | | | 561-805-6742 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-03 |
Time |
15:40 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-03 |
Time |
15:40 |
Sent To |
|
|
| Notes |
| 2017-11-03 15:36:36 | FOUR TIMES FEE FOR PLAN REVIEW ADDED, SEE BELOW. | | | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | PLEASE READ COMMENTS IN THEIR ENTIRETY AND RESPOND TO | | | ALL ITEMS. THERE ARE A TOTAL OF 7 COMMENTS. THE | | | RESPONSE LETTER PROVIDED STATED THE PREVIOUS COMMENTS | | | WERE ADDRESSED, BUT THE FOLLOWING ITEMS REMAIN | | | INCORRECT. | | | | | | 1. PREVIOUS COMMENT # 10. PROVIDE CARBON MONOXIDE | | | ALARMS AS REQUIRED PER CODE. FBC RE315.1 CO ALARMS ARE | | | REQUIRED WITHING 10 FEET OF EACH SLEEPING AREA. SEE | | | REFERENCED CODE AND PROVIDE CORRECTION. FBC R315.1 | | | 2. PREVIOUS COMMENT # 11. SHOW GFCI PROTECTED OUTLET | | | FOR GARAGE DOOR OPENER. NEC 210.8; FBC RE3902.2 | | | 3. PREVIOUS COMMENT # 12. 400 AMP SERVICE IS SHOWN WITH | | | 3/0 WIRE FEEDING THE SERVICE. 3/0 WIRE IS NOT RATED FOR | | | A 400 AMP SERVICE. PROVIDE CORRECTION. NEC | | | 310.15(B)(7),(16), FBC RE3603 | | | | | | NEW COMMENTS BASED ON SUBMITTED PLANS: | | | | | | 4. SHEET E-1 REFERENCED ON COVER SHEET IS NOT INCLUDED | | | IN PLANS. PROVIDE FULL SET OF PLANS FOR REVIEW. FBC | | | 107.2.1, 107.3.5 | | | 5. PROVIDE AFCI PROTECTION AS NOTED: ALL 120-VOLT, | | | SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS | | | SUPPLYING OUTLETS IN DWELLING UNIT FAMILY ROOMS, DINING | | | ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, | | | HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI | | | PROTECTION. NEC 210.12; FBC RE3902.12 | | | 6. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC CE R404.1 | | | 7. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-09-07 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-07 |
Time |
13:15 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-07 |
Time |
13:15 |
Sent To |
|
|
| Notes |
| 2017-09-07 13:15:46 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | PREVIOUS COMMENTS NOT ADDRESSED SATISFACTORILY: | | | | | | "9. AHU-1 SHOWS A 60 AMP FEED. THE PANEL SCHEDULE | | | STATES THIS IS A 17.5KW HEAT LOAD, WHICH EQUALS 72.92 | | | AMPS JUST FOR THE HEAT. PROVIDE CORRECT WIRE AND | | | BREAKER SIZING. NEC 240.4, 310.15(B)(16), 440.34; FBC | | | RE3702.11" THE DATA PROVIDED ON SHEET M-2 STATES THAT | | | AHU-1 WILL HAVE 10KW HEAT AND AHU-2 WILL HAVE 8KW HEAT. | | | CORRECT DISCREPANCY AND PROVIDE CORRECT WIRE AND | | | BREAKER SIZES FOR THESE UNITS. NEC 240.4, | | | 310.15(B)(16), 440.34; FBC RE3702.11 | | | "10. PROVIDE CARBON MONOXIDE ALARMS AS REQUIRED PER | | | CODE. FBC RE315.1" CO ALARMS ARE REQUIRED WITHING 10 | | | FEET OF EACH SLEEPING AREA. SEE REFERENCED CODE AND | | | PROVIDE CORRECTION. FBC R315.1 | | | "11. WILL THERE BE A GARAGE DOOR OPENER, WHICH NEEDS AN | | | OUTLET? CLARIFY AND/OR CORRECT. FBC 107.2.1" GARAGE | | | DOOR OPENER IS NOW SHOWN, BUT THERE IS NOT A GFCI | | | PROTECTED OUTLET FOR THE UNIT. PROVIDE CORRECTION. NEC | | | 210.8; FBC RE3902.2 | | | "12. PROVIDE DETAIL ON HOW THE FEED FROM TWO 200 AMP | | | PANELS WILL BE TIED INTO ONE 200 AMP SERVICE. FBC | | | 107.2.1; NEC 110.3" 400 AMP SERVICE IS SHOWN WITH 3/0 | | | WIRE FEEDING THE SERVICE. 3/0 WIRE IS NOT RATED FOR A | | | 400 AMP SERVICE. PROVIDE CORRECTION. NEC | | | 310.15(B)(7),(16), FBC RE3603 | | | | | | NEW COMMENTS BASED ON SUBMITTED PLANS: | | | | | | 1. SHEET E-1 REFERENCED ON COVER SHEET IS NOT INCLUDED | | | IN PLANS. PROVIDE FULL SET OF PLANS FOR REVIEW. FBC | | | 107.2.1, 107.3.5 | | | 2. PROVIDE AFCI PROTECTION AS NOTED: ALL 120-VOLT, | | | SINGLE PHASE, 15 AND 20 AMPERE BRANCH CIRCUITS | | | SUPPLYING OUTLETS IN DWELLING UNIT FAMILY ROOMS, DINING | | | ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, | | | BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, | | | HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI | | | PROTECTION. NEC 210.12; FBC RE3902.12 | | | 3. PROVIDE COMPLIANCE: "A MINIMUM OF 75 PERCENT OF THE | | | LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | BE HIGH-EFFICACY LAMPS OR A MINIMUM OF 75 PERCENT OF | | | THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL | | | CONTAIN ONLY HIGH EFFICACY LAMPS". A NOTE WILL SUFFICE. | | | FBC CE R404.1 | | | 4. PROVIDE TAMPER RESISTANT RECEPTACLES PER CODE. A | | | NOTE WILL SUFFICE. NEC 406.12; FBC RE4002.14 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-06-22 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-22 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-22 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2017-06-22 08:09:47 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: | | | | | | 1. PROVIDE ACCURATE LOAD CALCULATION WITH ALL LOADS | | | INCLUDED. CURRENTLY, A/C-2 OR AHU-2 IS NOT INCLUDED. | | | NEC 220; FBC RE3602.2 | | | 2. PROVIDE GFCI PROTECTED OUTLET ON 2ND FLOOR BALCONY. | | | NEC 210.52(E)(3); FBC RE3901.7 | | | 3. PROVIDE NOTE FOR LIGHTS LOCATED IN TUB/SHOWER AREAS | | | TO BE "SUITABLE FOR DAMP LOCATIONS". NEC 410.10(A); FBC | | | RE4003.11 | | | 4. PROVIDE CORRECTION FOR BATHROOM GFCI OUTLETS. BATH 1 | | | AND 2 HAVE RECEPTACLES AND LIGHTING ON THE SAME | | | CIRCUIT. CODE STATES: "A MINIMUM OF ONE 20 AMPERE | | | BRANCH CIRCUIT SHALL BE PROVIDED TO SUPPLY BATHROOM | | | RECEPTACLE OUTLET(S). SUCH CIRCUITS SHALL HAVE NO OTHER | | | OUTLETS". NEC 210.11(C)(3); FBC RE3703.4 | | | 5. PROVIDE GFCI PROTECTED OUTLET FOR SERVICING OF A/C | | | EQUIPMENT PER CODE. NEC 210.63; FBC RE3901.12 | | | 6. PLAN APPEARS TO SHOW AN OUTLET IN THE SHOWER AREA OF | | | BATH 1. PROVIDE CORRECTION AND/OR CLARIFICATION. FBC | | | 107.2.1; NEC 406.9(C); FBC RE4002.11 | | | 7. PANEL A, CIRCUIT 17 IS LABELED AS A 15 AMP CIRCUIT. | | | CODE REQUIRES A 20 AMP CIRCUIT. LIGHTING NOT PERMITTED | | | ON SAME CIRCUIT. PROVIDE CORRECTION. NEC 210.11(C), | | | 210.52(B); FBC RE3901.3 | | | 8. AHU-2 SHOWS A CIRCUIT THAT IS #6 WIRE ON A 60 AMP | | | BREAKER. #6 ROMEX WIRE, WHICH IS TYPICAL IN RESIDENTIAL | | | WIRING, IS NOT RATED FOR 60 AMPS. PROVIDE CORRECTION. | | | NEC 334.80; FBC RE3705.4.4 | | | 9. AHU-1 SHOWS A 60 AMP FEED. THE PANEL SCHEDULE STATES | | | THIS IS A 17.5KW HEAT LOAD, WHICH EQUALS 72.92 AMPS | | | JUST FOR THE HEAT. PROVIDE CORRECT WIRE AND BREAKER | | | SIZING. NEC 240.4, 310.15(B)(16), 440.34; FBC RE3702.11 | | | 10. PROVIDE CARBON MONOXIDE ALARMS AS REQUIRED PER | | | CODE. FBC R315.1 | | | 11. WILL THERE BE A GARAGE DOOR OPENER, WHICH NEEDS AN | | | OUTLET? CLARIFY AND/OR CORRECT. FBC 107.2.1 | | | 12. PROVIDE DETAIL ON HOW THE FEED FROM TWO 200 AMP | | | PANELS WILL BE TIED INTO ONE 200 AMP SERVICE. FBC | | | 107.2.1; NEC 110.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
4 |
Status |
P |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-22 |
Time |
16:11 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-22 |
Time |
16:11 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
F |
Date |
2017-10-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-10-30 |
Time |
13:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-10-30 |
Time |
13:25 |
Sent To |
|
|
| Notes |
| 2017-10-30 13:28:51 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. ONE PLAN SET DID NOT HAVE THE CORRECTED PLUMBING | | | PAGES PLEASE PROVIDE TWO COMPLETE SET OF PLANS. PER WPB | | | AMEND TO FBC 107.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2017-09-19 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-19 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-19 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2017-09-19 12:02:49 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. P-3 STATES FBC FG TABLE 402.4(2) WAS USED FOR | | | SIZING THE SYSTEM THAT TABLE IS FOR A .5 LB SYSTEM | | | UNDER THE GAS SYSTEM INFO IT CALLS OUT A 2LB SYSTEM | | | PLEASE CLARIFY IF IT IS A .5LB OR 2LB SYSTEM. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 2. SHT P-2 NOTES A TANKLESS PROPANE WATER HEATER PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. SHT P-1 DETAIL SHOWS A TANK TYPE HEATER SHT P-2+3 | | | SHOWS A TANKLESS WATER HEATER PLEASE CLARIFY. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 4. THE MANUAL FOR GAS RANGE DOES NOT LIST BTU LOAD OR | | | THE STANDARDS THAT IT MEETS SHALL MEET ANSI Z21.1, ANSI | | | Z21.58 OR ANSI Z83.11 PER FBC FG 623.1 | | | | | | 5. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. FOR FIRE PLACES AND | | | RANGE | | | | | | 6. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS SERVING FIRE PLACES PER | | | FBC-2014 FUEL GAS CODE SEC. 502 THRU 505. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-20 |
Time |
11:08 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-20 |
Time |
11:08 |
Sent To |
|
|
| Notes |
| 2017-06-20 11:26:45 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | GAS COMMENTS: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. TYPE OF GAS, (LP OR NATURAL). THE PLAN SHOWS BOTH | | | PROPANE AND NATURAL PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 3.SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402. THERE ARE CONFLICTING MEASUREMENTS PLEASE | | | CLARIFY PER WPB AMEND TO FBC 107.2.1 | | | | | | 4.SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | 5. IS THIS A 5LB SYSTEM RESIDENTIAL SYSTEMS ARE | | | TYPICALLY 2LB OR .05LB PLEASE CLARIFY. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | 6. YOU HAVE NOTED ON THE RISER DIAGRAM THE USE OF ANSUL | | | VALVES ON EVERY APPLIANCE PLEASE PROVIDE MANUFACTURE | | | SPEC FOR THESE VALVES WE DO NOT TYPICALLY SEE THESE ON | | | RESIDENTIAL SYSTEMS IS THIS A FIRE SUPPRESSION SYSTEM | | | VALVE PLEASE CLARIFY PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
N |
Date |
2017-06-19 |
|
|
Cont ID |
|
| Sent By |
fmittner |
Date |
2017-06-19 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
fmittner |
Date |
2017-06-19 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-06-07 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-05-29 |
Time |
16:17 |
Sent To |
|
|
| Notes |
| 2018-05-30 16:17:45 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-05-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-05-04 |
Time |
14:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-11-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-10-12 |
Time |
15:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-13 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-10-13 |
Time |
15:07 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-16 |
Time |
15:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-29 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-06 |
Time |
14:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2018-06-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-06-07 |
Time |
09:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-06-07 |
Time |
07:22 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2018-05-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-05-23 |
Time |
08:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-05-22 |
Time |
17:44 |
Sent To |
I |
|
| Notes |
| 2018-05-23 08:40:46 | 4TH REVIEW FBC-2014 RESIDENTIAL MECHANICAL | | | PERMIT #17060212 | | | 5/22/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | THE FOLLOWING REVIEW IS BASED ON THE NEW MECHANICAL | | | PLANS AND SPECIFICATIONS SUBMITTED. THE VOIDED PLANS | | | WERE NOT RETURNED WITH THE NEW PLAN SHEETS. | | | | | | 1) SHEET M-2: THE RETURN TRANSFER DUCTS FROM THE | | | BEDROOMS ARE UNDERSIZED PER SECTION M1602.4 ITEMS 1 & 2 | | | FBC-14 RESIDENTIAL. BECASUE ALL BEDROOMS ARE MASTER | | | SUITES CONTAINING BATHS AND CLOSET, AND EACH IS BEING | | | SUPPLIED BY A 16" X 10" DUCT, THEN EACH WILL REQUIRE A | | | TRANSFER DUCT WITH A MINIMUM CROSS SECTION AREA OF 240 | | | SQ. INCHES, | | | | | | 2) THE SUBMITTAL FOR THE EXHAUST HOOD INDICATES A | | | MAXIMUM EXHAUST RATE OF 900 CFMS WHICH WILL REQUIRE | | | MAKEUP AIR TO BE PROVIDED PER SECTION M1503.4. THE | | | MAKEUP AIR SYSTEM SHALL BE EQUIPPED WITH A MEANS OF | | | CLOSURE, AND SHALL BE AUTOMATICALLY CONTROLLED TO START | | | AND OPERATE SIMULTANEOUSLY WITH THE EXHAUST SYSTEM. | | | | | | 3) THE AHRI CERTIFICATES DO NOT MATCH WITH THE NEW 4 | | | AND 2.5-TON AC SYSTEMS SELECTED AND SHOWN IN THE | | | SCHEDULES ON M-2. | | | | | | 4) THE RESCHECK ENERGY EFFICIENCY CERTIFICATE DOES NOT | | | PROVIDE ANY COMPLIANCE DATA FOR THE AC SYSTEMS OR THE | | | WATER HEATER. | | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2017-11-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-11-22 |
Time |
10:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-11-22 |
Time |
10:33 |
Sent To |
|
|
| Notes |
| 2017-11-22 10:48:55 | 3RD REVIEW FBC-2014 RESIDENTIAL MECHANICAL | | | PERMIT #17060212 | | | 11/22/17 | | | | | | PLAN REVIEW RESULTS: DENIED | | | | | | COMMENTS 4, 5, & 6 FROM THE PREVIOUS (2ND) REVIEW HAVE | | | NOT BEEN ADDRESSED COMPLETELY. THOSE COMMENTS ARE | | | PRINTED BELOW | | | | | | 1) AS PREVIOUSLY REQUESTED IN THE FIRST REVIEW, | | | INDICATE HOW COMBUSTION AIR IS BEING PROVIDED FOR THE | | | GAS FIREPLACE (COMMENT #4). THE SUBMITTED INSTALLATION | | | GUIDELINES ARE INDICATING THE UNIT IS " DESIGNED TO | | | OPERATE WITH ALL COMBUSTION AIR BEING SIPHONED FROM THE | | | OUTSIDE OF THE BUILDING" (PAGE 5). PLEASE PROVIDE | | | DETAILS ON THE PLAN INDICATING COMPLIANCE. | | | | | | 2) AS PREVIOUSLY REQUESTED PROVIDE A VENTING PLAN FOR | | | THE FIREPLACE (COMMENT #5). PLEASE SEE PAGE 14 WHICH | | | SHOWS A LIST OF ACCEPTABLE VENT SYSTEMS AND SUBMIT THE | | | SPECIFICATIONS AND INSTALLATION GUIDELINES. | | | | | | 3) REFER TO SECTION 1503.4 FBC-14 RESIDENTIAL AND | | | PROVIDE A MAKEUP AIR SYSTEM FOR THE NEW AIRFLOW RANGE | | | HOOD. | | | | | | | | | 2ND REVIEW FBC-2014 RESIDENTIAL MECHANICAL | | | | | | 4) THE PLUMBING PLANS ARE INDICATING A GAS FIREPLACE IN | | | THE MASTER BEDROOM AND A NEW GAS RANGE IN THE KITCHEN. | | | PLEASE SUBMIT PRODUCT DATA SHEETS FOR BOTH APPLIANCES- | | | SECTIONS G2434 & G2435. PLEASE NOTE COMBUSTION AIR | | | SHALL BE REQUIRED IN ACCORDANCE WITH MANUFACTURER'S | | | SPECIFICATIONS AND THE SECTION 304 FBC-14 FUEL GAS. | | | | | | 5) PROVIDE A VENTING PLAN FOR THE GAS FIREPLACE WHICH | | | SHOWS THE TYPE AND SIZE OF VENT FLUE, THE VENT FLUE | | | RUN, AND THE TERMINATION LOCATION- SECTION G2427. | | | SUBMIT SPECS FOR THE VENT FLUE. | | | | | | 6) REFER TIO SECTION M1503 AND CLARIFY IF A NEW RANGE | | | HOOD WILL BE INSTALLED OVER THE NEW GAS RANGE, AND | | | PROVIDE EXHAUST VENTILATION DETAILS AND PRODUCT SPEC | | | SHEETS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-15 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-15 |
Time |
08:11 |
Sent To |
|
|
| Notes |
| 2017-09-15 09:00:09 | 1ST REVIEW FBC-2014 RESDIENTIAL MECHANICAL | | | PERMIT #17060212 | | | 9/15/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) M-2: THE 12" TRANSFER DUCT FROM THE MASTER BEDROOM | | | IS UNDERSIZED. REFER TO SECTION M1602.4 EXCEPTIONS 1 & | | | 3, FBC-14 RESIDENTIAL: THE PLAN SHOWS A 10"X16" DUCT | | | ENTERING THE MASTER SUITE WHICH, PER THE CODE SECTIONS, | | | REQUIRES A TRANSFER DUCT TO SIZED AT 1-1/2 TIMES THE | | | CROSS SECTIONAL AREA OF THE 10"X16" DUCT. THE MINIMUM | | | TRANSFER DUCT SIZE THEREFORE MUST BE 16". | | | | | | 2) M-2: AS PREVIOUSLY REQUESTED, SHOW THE CONDENSATE | | | PIPING RUNS AND DISCHARGE LOCATIONS. SUBMIT SPECS FOR | | | THE CONDENSATE PUMPS (IF APPLICABLE)- SECTION M1411.3 | | | | | | 3) M-2: AS PREVIOUSLY REQUESTED, PROVIDE INSTALLATION | | | DETAILS FOR THE EXTERIOR CONDENSERS- SEE SECTIONS | | | M1305.1.4.1 AND M1401.4 . | | | | | | 4) THE PLUMBING PLANS ARE INDICATING A GAS FIREPLACE IN | | | THE MASTER BEDROOM AND A NEW GAS RANGE IN THE KITCHEN. | | | PLEASE SUBMIT PRODUCT DATA SHEETS FOR BOTH APPLIANCES- | | | SECTIONS G2434 & G2435. PLEASE N0OTE COMBUSTION AIR | | | SHALL BE REQUIRED IN ACCORDANCE WITH MANUFACTURER'S | | | SPECIFICATIONS AND THE SECTION 304 FBC-14 FUEL GAS. | | | | | | 5) PROVIDE A VENTING PLAN FOR THE GAS FIREPLACE WHICH | | | SHOWS THE TYPE AND SIZE OF VENT FLUE, THE VENT FLUE | | | RUN, AND THE TERMINATION LOCATION- SECTION G2427. | | | SUBMIT SPECS FOR THE VENT FLUE. | | | | | | 6) REFER TIO SECTION M1503 AND CLARIFY IF A NEW RANGE | | | HOOD WILL BE INSTALLED OVER THE NEW GAS RANGE, AND | | | PROVIDE EXHAUST VENTILATION DETAILS AND PRODUCT SPEC | | | SHEETS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-29 |
Time |
10:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-29 |
Time |
10:11 |
Sent To |
|
|
| Notes |
| 2017-06-29 10:18:55 | 1ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL , ENERGY | | | CONSERVATION CODES | | | PERMIT #17060212 | | | 6/29/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) REFER TO R101.4.5 ENERGY CONSERVATION: THE | | | PREVIOUSLY UNCONDITIONED RESIDENCE THAT IS NOW BECOMING | | | CONDITIONED SPACE SHALL BE BROUGHT INTO FULL COMPLIANCE | | | WITH THE CODE. PLEASE SEE SECTION R101.5.1 AND SUBMIT | | | AN ENERGY COMPLIANCE FORM. | | | | | | 2) SHEET M-2: THE AC CALC PASTED ON THE PLAN SHEET ARE | | | NOT CONSISTENT WITH THE AC SYSTEMS SPECIFIED ON THE | | | PLANS. THE CALCULATION WHICH IS TITLED "SYSTEM #1" ARE | | | INDICATING A COOLING LOAD OF APPROXIMATELY 25,000 BTUH, | | | HOWEVER THE PLANS ARE INDICATING SYSTEM 1 AT 60,000 | | | BTUH AND SYSTEM 2 AT 42,000 BTUH- SEE SECTION R403.6.1 | | | FBC-14 ENERGY CONSERVATION AND PROVIDE COMPLETE AC | | | CALCULATIONS INCLUDING THE MANUAL J WORKSHEETS. | | | | | | 3) M-2: THE1ST FLOOR MAIN RETURN GRILL SHALL NOT BE | | | LOCATED IN THE KITCHEN- SECTION M1602 ITEM #4 FBC-14 | | | RESDIENTIAL. PLEASE RELOCATE THE GRILL AND PROVIDE IT'S | | | DIMENSIONS. | | | | | | 4) M-2: AHU-1 LOCATED IN THE GARAGE SHALL BE PROTECTED | | | FROM VEHICAL IMPACT- SECTION M1307.3.1 FBC-14 | | | RESIDENTIAL. | | | | | | 5) M-2: PROVIDE THE DIMENSIONS OF THE SECOND FLOOR MAIN | | | RETURN GRILL IN THE HALLWAY, | | | | | | 6) M-2: PROVIDE THE SIZE OF THE TRANSFER DUCT AT THE | | | 18X10 RETURN FRILL IN THE SECOND FLOOR MASTER BEDROOM. | | | PLEASE SEE SECTION M1602.4 EXCEPTIONS 1, 2, & 3 TO SIZE | | | THE RETURN COMPONENTS IN COMPLIANCE WITH THE CODE. | | | | | | 7) M-2: SHOW THE CONDENSATE PIPING RUNS AND DISCHARGE | | | LOCATIONS. SUBMIT SPECS FOR THE CONDENSATE PUMPS (IF | | | APPLICABLE). | | | | | | 8) M-2: THE DRYER EXHAUST DUCT SHALL HAVE A SMOOTH | | | INTERIOR FINISH AND BE MINIMUM 28 GAUGE- SECTION | | | M1502.4.1. FLEX DUCTS ARE NOT PERMITTED. | | | | | | 9) M-2: PROVIDE INSTALLATION DETAILS FOR THE EXTERIOR | | | CONDENSERS- SEE SECTIONS M1305.1.4.1 AND M1401.4 . | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-05-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-05-22 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-05-22 |
Time |
16:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-10-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-10-30 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
| 2017-10-30 13:29:18 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. ONE PLAN SET DID NOT HAVE THE CORRECTED PLUMBING | | | PAGES PLEASE PROVIDE TWO COMPLETE SET OF PLANS. PER WPB | | | AMEND TO FBC 107.2 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-20 |
Time |
10:50 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-20 |
Time |
09:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2017-09-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-09-15 |
Time |
14:09 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-09-15 |
Time |
11:24 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-06-29 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-29 |
Time |
14:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-29 |
Time |
14:01 |
Sent To |
|
|
| Notes |
| 2017-06-29 14:02:55 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE PRODUCT APPROVALS FOR NEW ROOF SYSTEM | | | COMPONENTS. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE ROOFING SUBMITTALS. |
|
|