| Plan Review Stops For Permit 17060189 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-28 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-28 |
Time |
14:10 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-03 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-03 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-13 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-30 |
Time |
10:43 |
Sent To |
|
|
| Notes |
| 2017-09-13 16:05:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 17060191 APARTMENT BUILDING # | | | 17060189 APARTMENT BUILDING, 2191 N AUSTRALIAN AVE (SIX | | | STORY) | | | 17060192 CLUBHOUSE BUILDING | | | | | | COMMENTS FROM PREVIOUS REVIEW; UNABLE TO LOCATE A | | | RESPONSE LETTER; EMAILED APPLICANT. | | | | | | 1-2. OK | | | | | | 3. ADDRESS PLUMBING COMMENTS REGARDING FAIR HOUSING AS | | | THEY ARE APPLICABLE FOR BUILDING REVIEW. | | | | | | 4. FBC B 1803, PROVIDE THE GEOTECHNICAL INVESTIGATION | | | REPORT. 2ND REQUEST. | | | | | | 5-8. OK | | | | | | 9. FBC B 1207.2, 1207.3, REVISE COVER PAGE TO INCLUDE | | | FLOORING UNDERLAYMENT AS AN ITEM TO BE SUBMITTED AT A | | | LATER TIME. | | | | | | 12-13. OK | | | | | | 14. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A. SEPARATE PERMITS REQUIRED FOR FENCING, SITE WALLS, | | | SIGNAGE, PARKING LOT/PAVING, DUMPSTER ENCLOSURE. | | | | | | B. FLOORING UNDERLAYMENT TEST REPORTS (STC, IIC, FLAME | | | SPREAD) REQUIRED TO BE SUBMITTED PRIOR TO INSTALLATION. | | | | | | C. SEPARATE ROOF PERMIT REQUIRED. NOA 15-1026.04 WAS | | | SUBMITTED; WHEN SUBMITTING ROOF PERMIT APPLICATION, | | | INDICATE ASSEMBLY PROPOSED AND PROVIDE ENGINEERING IF | | | REQUIRED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-17 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-14 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2017-07-17 15:35:43 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 17060191 APARTMENT BUILDING # | | | 17060189 APARTMENT BUILDING A (SIX STORY) | | | 17060192 CLUBHOUSE BUILDING | | | | | | 1. ALL PAGES HAVE AN INCORRECT ADDRESS AND NOT ALL ARE | | | CONSISTENT WITH EACH OTHER (DIFFERENT INCORRECT | | | ADDRESSES). FBC 107, PLEASE CORRECT THE ADDRESS ON EACH | | | PAGE. | | | | | | 2. FS471.0195, THE DBPR RECORD FOR THE FOLLOWING | | | ENGINEER(S) DO NOT REFLECT THAT THE ADVANCED FLORIDA | | | BUILDING CODE COURSE HAS BEEN COMPLETED. EMAIL THE | | | CERTIFICATE TO FBPE AND REQUEST THAT THE DBPR RECORD BE | | | UPDATED. NOTE THAT IT IS POSSIBLE THAT THE COURSE WAS | | | COMPLETED AND THE WEBSITE IS NOT CURRENT. | | | | | | SANTIAGO ARANEGUI, PE | | | JOE SPASOVSKI, PE | | | | | | PERMIT ISSUANCE WILL NOT BE DELAYED DUE TO THIS | | | COMMENT. HOWEVER, FLORIDA STATUTE REQUIRES THAT: | | | LOCAL JURISDICTIONS SHALL BE RESPONSIBLE FOR NOTIFYING | | | THE BOARD WHEN DESIGN DOCUMENTS ARE SUBMITTED FOR | | | BUILDING CONSTRUCTION PERMITS BY PERSONS WHO ARE NOT IN | | | COMPLIANCE WITH THIS SECTION. | | | | | | 3. ADDRESS OTHER TRADES' COMMENTS REGARDING FAIR | | | HOUSING AS THEY ARE APPLICABLE FOR BUILDING REVIEW. | | | | | | 4. FBC B 1803, PROVIDE THE GEOTECHNICAL INVESTIGATION | | | REPORT. THIS IS AREA IS KNOWN TO HAVE THE POTENTIAL OF | | | POOR SOILS. | | | | | | 5. SECTION 5-A6.6.2, REVISE PLAN TO SHOW FRT (LUMBER) | | | OR REVISE PLAN TO INCLUDE APPLICABLE EXCEPTION, FBC B | | | 602. REVISE OTHER LOCATIONS WHICH SHOW WOOD (SUCH AS | | | MUTIPLE DETAILS, S3.5). | | | | | | 6. S1.0, ROOF LIVE LOAD IS 20PSF; FBC B TABLE 1607.1 | | | REQUIRES 300 CONCENTRATED FOR "ALL ROOF SURFACES | | | SUBJECT TO MAINTENANCE WORKERS". RTU EQUIPMENT SHOWN. | | | EITHER REVISE DESIGN CRITERIA FOR THIS ROOF SECTION OR | | | PROVIDE RATIONALE FOR 20PSF LIVE LOAD. | | | | | | 7. IT APPEARS THAT NOT ALL LAP SPLICES WERE SPECIFIED | | | ON THE PLAN FOR THE FOUNDATION; REVISE PLAN OR ADVISE | | | WHERE THIS CAN BE LOCATED, FBC 107, FBC B CHAPTER 19. | | | | | | 8. FBC B 420.3, PROVIDE A DETAIL SHOWING COMPLIANCE | | | WITH THE 1 HOUR SEPARATION REQUIREMENT FOR THE | | | FLOOR/CEILING ASSEMBLIES BETWEEN UNITS. REVISE THE PLAN | | | TO SHOW THE 1 HOUR (MINIMUM) FLOOR/CEILING ASSEMBLY. | | | | | | 9. FBC B 1207.2, 1207.3, PROVIDE TEST REPORTS FOR THE | | | FLOORING UNDERLAYMENT (STC/IIC). REVISE PLAN TO INCLUDE | | | REQUIREMENT FOR ACOUSTIC INSULATION. NOTE THAT SPEC | | | SHEETS ARE NOT ACCEPTABLE; ACTUAL TEST REPORTS ARE | | | REVIEWED. IT IS LIKELY THAT THE MANUFACTURER WILL BE | | | REQUIRED TO DO A COMPARATIVE ANALYSIS AS IT IS UNLIKELY | | | THAT THE UNDERLAYMENT WAS TESTED WITH HOLLOW CORE (MOST | | | TESTS ARE DONE WITH A CONCRETE SLAB). | | | | | | CSM CRACK SUPPRESSION & SOUND CONTROL SPEC SHEET WAS | | | PROVIDED. PLEASE SEND TEST REPORTS VIA EMAIL FOR | | | PRELIMINARY REVIEW. WHEN REVISING PLAN TO INCLUDE | | | UNDERLAYMENT REQUIREMENT, IT IS ADVISED THAT YOU DO NOT | | | SPEC A PRODUCT. | | | | | | 10. FBC 720.2, PROVIDE A COPY OF THE FLAME SPREAD TEST | | | FOR THE PROPOSED FLOORING UNDERLAYMENT. | | | | | | 11. AS THIS IS NEW CONSTRUCTION, APPLY FOR AN | | | ENGINEERING PERMIT; 561-494-1040. ENGINEERING | | | DEPARTMENT APPROVAL IS REQUIRED PRIOR TO PERMIT | | | ISSUANCE. CONTACT THEM DIRECTLY REGARDING REQUIREMENTS. | | | IF YOU HAVE ALREADY APPLIED, PROVIDE THE APPLICATION | | | NUMBER. I WAS UNABLE TO LOCATE AN ENGINEERING | | | APPLICATION FOR THIS PARCEL ID. | | | | | | HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR | | | MS,-PERMITS-APPLICATIONS | | | | | | 12. A SEPARATE ROOF PERMIT IS REQUIRED. A ROOF PRODUCT | | | APPROVAL WAS SUBMITTED, FIBERTITE SINGLE PLY ROOF | | | SYSTEMS OVER LIGHTWEIGHT CONCRETE DECKS (NOA | | | 15-1026.04). | | | | | | FBC 1609, AT THIS TIME, APPLICANT MAY INDICATE WHICH | | | APPROVED ASSEMBLY IS PROPOSED. IF THIS IS DONE NOW, THE | | | ROOF SUB PERMIT WILL BE ISSUED WITHOUT ANY OTHER | | | INFORMATION REQUIRED. | | | | | | IF APPLICANT DOES NOT PROVIDE THIS INFORMATION AT THIS | | | TIME, THIS PERMIT WILL BE ISSUED WITH PROVISO THAT, AT | | | TIME OF ROOF SUB PERMIT APPLICATION, THE APPROVED | | | ASSEMBLY IS TO BE SELECTED. A PLAN REVIEW WILL BE | | | REQUIRED AT THAT TIME. | | | | | | 13. WHEN AVAILABLE, PROVIDE A COPY OF THE CONTRACT FOR | | | THE THREE PROPOSED BUILDINGS, FBC 109. | | | | | | 14. THIS PERMIT WILL BE ISSUED WITH PROVISOS: | | | | | | A. SEPARATE PERMITS REQUIRED FOR FENCING, SITE WALLS, | | | SIGNAGE, PARKING LOT/PAVING, DUMPSTER ENCLOSURE, | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-11-03 |
Time |
09:17 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-11-03 |
Time |
09:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-09-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-05 |
Time |
12:29 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-05 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2017-09-05 12:29:49 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. ADDRESS NUMBER ON PERMIT APPLICATION IS 2191, ON | | | COVER SHEET IS 2181, AND ON ELECTRICAL SHEETS IS 2180. | | | PROVIDE CORRECT ADDRESS ON PLANS. FBC 107.2.1 | | | 2. SHEET E-8 SHOWS 6 SETS OF 750 KCMIL CU FOR SERVICE | | | FEEDERS, WHILE SHEET E-6 SHOWS 7 SETS OF 600 KCMIL CU. | | | CORRECT DISCREPANCY. FBC 107.2.1 | | | 3. LOAD CALCULATION FOR MDP SHOWS SEVERAL DIFFERENT | | | CALCULATIONS (ONE STORY, TWO STORY, ETC.). PROVIDE LOAD | | | CALCULATION RELATED TO THIS PERMIT ONLY FOR THE SIX | | | STORY BUILDING. REMOVE ALL OTHER UNRELATED INFORMATION. | | | ADDITIONALLY, THE LOAD VA SHOWN FOR THE 1 BEDROOM UNIT | | | IS THE SAME AS FOR THE 2 BEDROOM UNIT. LOAD CALCULATION | | | FOR PANEL H IS DIFFERENT THAN LISTED IN PANEL SCHEDULE. | | | PROVIDE CORRECTIONS. NEC 220; FBC 107.2.1 | | | 4. PANEL H SHOWS A JOCKEY PUMP ON CIRCUIT 19, 21, 23. | | | IS THIS THE JOCKEY PUMP FOR THE FIRE PUMP SYSTEM? IF | | | SO, THIS CANNOT BE FEED FROM PANEL H. THE JOCKEY PUMP | | | SPECIFIED ON SHEET FP 2.0 IS NOT SHOWN ON RISER DIAGRAM | | | WITH FIRE PUMP. PROVIDE CORRECTION. NEC 215.5, | | | 695.4(B)(3); FBC 107.2.1 | | | 5. FIRE PUMP SERVICE IS NOT LABELED AS ONE OF THE MAINS | | | FOR THE BUILDING. PROVIDE CORRECTION. NEC 230.2(E) | | | 6. PANEL H LOAD CALCULATION STATES THAT THE FIRST 10K | | | VA ARE AT 100%. HOWEVER, THE LOAD SHOWN IS 4320 VA, NOT | | | 10,000. PANEL H1 LOAD CALCULATION IS SIMILARLY WRONG. | | | PROVIDE CORRECTION. NEC 220.44 | | | 7. PROVIDE DETAILS OF SECOND POWER SOURCE REQUIRED FOR | | | FIRE PUMP. NEC 695.3(B) | | | 8. PROVIDE LOAD CALCULATION FOR FIRE PUMP CONTROLLER | | | AND ASSOCIATED EQUIPMENT TO VERIFY FEEDER, GROUNDING, | | | AND OVERCURRENT PROTECTION REQUIREMENTS. NEC 695.6 | | | 9. PLAN STATES THAT THE LOCKED ROTOR CURRENT FOR THE | | | FIRE PUMP MOTOR IS 32.2 AMPS. ACCORDING TO TABLE | | | 430.251(B), THE LOCKED ROTOR CURRENT FOR A MOTOR THIS | | | SIZE SHOULD BE 179 AMPS. PROVIDE CORRECTION. NEC TABLE | | | 430.251(B); FBC 107.2.1 | | | 10. PLAN INCLUDES ELECTRICAL PLAN FOR 1ST FLOOR, 4TH | | | FLOOR, AND ROOF ONLY. PROVIDE FULL SET OF PLANS FOR | | | REVIEW. FBC 107.2.1, 107.3.5 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-07-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-07-03 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-07-03 |
Time |
15:17 |
Sent To |
|
|
| Notes |
| 2017-07-03 15:29:16 | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | PAGE E-6 NEED TO SIZE THE FIRE PUMP AND CONTROLER | | | | | | PAGE E-6 NEED TO SUPPLY AN INTYERSYSTEM BONDING STRIP | | | AT EAC SERVICE LOCATION PER 250.94 | | | | | | PAGE E-8 NO SITE LIGHT CIRCUITS SHOWN, ARE THERE ANY | | | FIXTURES ON THE BUILDING? |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2017-10-05 |
|
|
Cont ID |
|
| Sent By |
squinone |
Date |
2017-10-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
squinone |
Date |
2017-10-05 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-10-05 15:44:26 | 1) NO CIVIL PLANS WERE INCLUDED WITH THIS SUBMITTAL. | | | CIVIL PLANS ARE UNDER REVIEW THROUGH ENGINEERING PLAN | | | REVIEW, E17060013. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2017-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-17 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-17 |
Time |
08:10 |
Sent To |
|
|
| Notes |
| 2017-07-17 08:10:43 | CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT | | | APPLICATION IF REQUIRED | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE | | | | | | MAIN PHONE: (561) 822-1200 | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-10-25 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-10-25 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-10-25 |
Time |
10:12 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-08-18 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-08-18 |
Time |
09:25 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-08-16 |
Time |
16:06 |
Sent To |
|
|
| Notes |
| 2017-08-18 09:18:00 | 2181 NORTH AUSTRALIAN AVENUE - 6 STORY APARTMENTS | | | PERMIT #17060189 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | CIVIL SHEET 2 OF 14: PROVIDE A FIRE DEPARTMENT KNOX KEY | | | SWITCH TO ALLOW EMERGENCY RESPONSE VEHICLES ACCESS INTO | | | THE PROPERTY. BOTH GATES SHALL FUNCTION SIMULTANEOUSLY. | | | | | | CIVIL SHEET 6 OF 14: A POST INDICATOR VALVE (PIV) WILL | | | BE NEEDED TO ISOLATE EACH FIRE PROTECTION SERVICE MAIN | | | ENTERING EACH BUILDING. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-06-21 |
Time |
13:50 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-06-21 |
Time |
12:15 |
Sent To |
|
|
| Notes |
| 2017-06-21 12:16:09 | 2181 NORTH AUSTRALIAN AVENUE - 6 STORY APARTMENTS | | | PERMIT #17060189 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | NO CIVIL PLANS SUBMITTED. | | | | | | PER NFPA 241 SECTION 8.7.2.3, WHERE UNDERGROUND WATER | | | MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL BE | | | INSTALLED, TESTED, APPROVED, AND IN SERVICE PRIOR TO | | | VERTICAL CONSTRUCTION WORK. | | | | | | WILL ANY CONSTRUCTION TRAILERS BE LOCATED ON SITE? THE | | | CITY OF WEST PALM BEACH REQUIRES CONSTRUCTION TRAILERS | | | LARGER THAN A SINGLE "DOUBLE WIDE" (OR TWO "SINGLE | | | WIDE") TO EITHER BE PROTECTED BY AN AUTOMATIC SPRINKLER | | | SYSTEM OR COMPLY WITH THE SEPARATION REQUIREMENTS OF | | | NFPA 241. TEMPORARY CONSTRUCTION TRAILERS OR MODULAR | | | BUILDINGS WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE | | | FOLLOWING: | | | PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION, | | | ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2: | | | TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF | | | COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE | | | CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS, | | | TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1. | | | PER TABLE 4.2.1: | | | 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 30 FEET | | | 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 35 FEET | | | 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 40 FEET | | | 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 45 FEET | | | 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM | | | ADJACENT STRUCTURES BY AT LEAST 50 FEET | | | 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE | | | SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET | | | **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL | | | BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC | | | SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE. | | | | | | PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN | | | TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE | | | PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE | | | PROVIDED AS REQUIRED BY THE AUTHORITY HAVING | | | JURISDICTION. | | | | | | PLANS INDICATE AN ADDRESS OF 2181; HOWEVER, THE PERMIT | | | APPLICATION INDICATES THE ADDRESS TO BE 2191 NORTH | | | AUSTRALIAN AVENUE. | | | | | | SHEET A-6.9.2: PER NFPA 101 SECTION 7.2.2.6.2 VISUAL | | | PROTECTION. OUTSIDE STAIRS SHALL BE ARRANGED TO AVOID | | | ANY IMPEDIMENTS TO THEIR USE BY PERSONS HAVING A FEAR | | | OF HIGH PLACES. OUTSIDE STAIRS MORE THAN 36 FEET ABOVE | | | THE FINISHED GROUND LEVEL SHALL BE PROVIDED WITH AN | | | OPAQUE VISUAL OBSTRUCTION NOT LESS THAN 48-INCHES IN | | | HEIGHT. | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2017-12-21 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-21 |
Time |
13:06 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-20 |
Time |
09:11 |
Sent To |
|
|
| Notes |
| 2017-12-21 09:11:49 | IMPACT FEES ROUTED TO ACLANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-28 |
Time |
14:34 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-16 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2017-11-16 12:04:12 | GJOHNSTON'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-03 |
Time |
16:18 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-10-19 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-10-11 |
Time |
08:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-07 |
Time |
15:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-17 |
Time |
15:35 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-05 |
Time |
13:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
P |
Date |
2017-12-21 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-21 |
Time |
12:46 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-21 |
Time |
11:48 |
Sent To |
|
|
| Notes |
| 2017-12-21 12:49:47 | PALM BEACH COUNTY IMPACT FEES PAID. $527,017.05 | | | RECEIPT NO: 2017-1220-331 | | | 12/20/2017 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-28 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-28 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2017-11-28 14:34:01 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-03 |
Time |
16:08 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-03 |
Time |
16:08 |
Sent To |
|
|
| Notes |
| 2017-11-03 16:09:57 | ****PLAN REVIEW COMMENTS**** | | | | | | ART LANGE - BUILDING INSPECTOR | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT | | | FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID. | | | UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE | | | SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN | | | IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP | | | AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE | | | CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN | | | BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY | | | IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-14 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-14 |
Time |
15:21 |
Sent To |
|
|
| Notes |
| 2017-07-14 15:22:54 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED. | | | | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT FEES DUE WERE PAID, IF APPLICABLE, IS TO BE | | | PROVIDED. | | | | | | 561-233-5025 FOR MORE INFORMATION. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-10-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-10-31 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-10-30 |
Time |
17:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-06 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-06 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2017-09-06 10:13:28 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17060189 | | | 9/6/17 | | | | | | 1) THE ENERGYGAUGE SUMMIT IECC COMPLIANCE FORM DOES NOT | | | INCLUDE DATA FOR THE ACCU- AHU #1, 2, & 3 SYSTEM. | | | | | | 2) PLEASE SEE COMMENT #3 FROM THE 1ST REVIEW AND | | | SECTION C407.5.2.3 FBC-14 ENERGY CONSERVATION- PROVIDE | | | AC CALCULATIONS USING ONE THERMAL BLOCK PER SPACE, OR | | | ONE THERMAL BLOCK FOR MULTIPLE SPACES THAT ARE FACING | | | THE SAME ORIENTATIONS. PLEASE NOTE THAT CORNER UNITS | | | AND UNITS WITH ROOFS OR FLOOR LOADS SHALL ONLY BE | | | COMBINED WITH UNITS SHARING THE SAME FEATURES. IN | | | ADDITION | | | | | | PLEASE REFER TO SECTION C403.2.1: DESIGN LOADS SHALL BE | | | DETERMINED IN ACCORDANCE WITH THE PROCEDURES DESCRIBED | | | IN THE ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL N AND | | | SHALL BE ATTACHED TO THE CODE COMPLIANCE FORM SUBMITTED | | | TO THE BUILDING DEPARTMENT. | | | | | | 3) M-4: PLEASE ENLARGE THE AC EQUIPMENT SCHEDULE FOR | | | THE APARTMENT UNITS AND NUMBER THEM AS EITHER AC-1 OR 2 | | | AS THEY ARE SHOWN ON THE DRAWINGS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-07-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-03 |
Time |
09:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-30 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2017-07-03 09:55:19 | 1ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | | PERMIT #17060189 | | | 7/3/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE LOUVERED AC CLOSETS DOORS SHALL BE | | | NON-COMBUSTIBLE PER SECTION C403.2.7.2 FBC-14 ENERGY | | | CONSERVATION. THE DOOR SCHEDULE ON SHEET A-8.1 | | | INDICATES WOOD DOORS. | | | | | | 2) THE SUBMITTED ENERGYGAUGE FORM R405-2014 IS A | | | RESDIENTIAL COMPLIANCE FORM, HOWEVER THE PROPOSED | | | PROJECT IS A COMMERCIAL BUILDING- SEE SECTION C202 & | | | R202 DEFINITIONS FBC-14 ENERGY CONSERVATION. PLEASE SEE | | | SECTIONS C101.5 & C407.4.1 AND SUBMIT A COMMERCIAL | | | COMPLIANCE FORM. | | | | | | 3) THE SUBMITTED ENERGYGAUGE FORM R405-2014 IS | | | SPECIFYING A WORST CASE METHOD, HOWEVER THAT METHOD IS | | | NOT APPLICABLE TO A COMMERCIAL BUILDING PROJECT. PLEASE | | | SEE SECTIONS C407.4.2- C407.5.2.3 FOR THERMAL ZONING | | | BLOCKS USING DEFINED HVAC ZONES ON THE PLANS, OR | | | UNDEFINED ZONES. | | | | | | 4) SHEET M-3: CONTRARY TO THE NOTE ON THE ROOF PLAN | | | THERE ARE NO STRUCTURAL DETAILS FOR MOUNTING THE AC | | | STANDS AND CONDENSER TO THE ROOF STRUCTURE. PLEASE | | | PROVIDE THE WIND LOAD DESIGN CRITERIA AND STRUCTURAL | | | DETAILS PER SECTION 301.15 FBC-14 MECHANICAL. | | | ADDITIONALLY, THE ENGINEER OF RECORD SHALL CIRCLE, | | | HIGHLIGHT, OR OTHERWISE MARKUP THE AC STAND NOA TO SHOW | | | THE APPLICABLE | | | INSTALLATION DETAILS. PLEASE INDICATE THE STAND | | | CONFIGURATION, STAND ANCHORING TO THE ROOF, AND | | | CONDENSER ANCHORING TO THE STAND. | | | | | | 5) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR THE | | | APARTMENTS IN COMPLIANCE WITH TABLE 403.3 OR TABLE 6-1 | | | ASHRAE 62.1. INDICATE THE REQUIRED AND PROVIDE | | | VENTILATION RATES. | | | | | | 6) PROVIDE MINIMUM VENTILATION CALCULATIONS AND | | | VENTILATION PLANS FOR THETRASH COMPACTOR ROOM, THE | | | ELECTRICAL ROOMS, AND THE PUMP ROOM- SEE TABLE 403.3. | | | PLEASE NOTE THAT TABLE 6-4 ASHRAE 62.1 REQUIRES AN | | | EXHAUST SYSTEM FOR THE TRASH COMPACTOR ROOM DESIGNED AT | | | A RATE OF 1 .00 CFM PER SQ. FT. | | | | | | 7) INDICATE HOW THE ELEVATOR HOISTWAY WILL BE VENTED IN | | | ACCORDANCE WITH SECTION 3004 FBC-14 BUILDING. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-11-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-28 |
Time |
08:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-28 |
Time |
08:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2017-11-01 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-11-01 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-11-01 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2017-11-01 17:10:21 | 3RD REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT. A - 6.5.1 - A -6.5.4 FHA REQUIREMENTS. | | | | | | A) THE GRAB BAR WOULD MOUNTED ON THE OPPOSITE SIDE OF | | | THE TOILET FROM THE APPROACH WHICH WOULD BE HE TUB SIDE | | | WHICH WOULD REQUIRE THE 18" REQUIRED CLEARANCE TO BE ON | | | THE TUB SIDE NOT VANITY SIDE. PER FHA DESIGN MANUAL PG. | | | 6.5 - 6.7 | | | B) THE BOTTOM OF THE BACKING ON THE SIDE WALL OF THE | | | TUB SHALL BE 6"MAX FROM TOP OF TUB. PER FHA DESIGN | | | MANUAL PG. 6.9 | | | C) SHOW THE CLEAR FLOOR SPACE FOR THE TOILET. PER FHA | | | DESIGN MANUAL PG. 7.43 | | | D) THE VANITY SHALL HAVE A MAXIMUM DEPTH OF 24". PER | | | FHA DESIGN MANUAL PG.7.43 | | | | | | 2. THE SANITARY ISOMETRIC DRAWING IS TO COMPACT AND TO | | | CONGESTED IT MAKES IT EXTREMELY HARD TO READ AND WHEN | | | IT IS SCANNED FOR OUR RECORDS IT WILL BE WORSE, THE MIN | | | REQUIREMENT FOR PLANS IS 1/8IN. SCALE PER WPB AMEND TO | | | FBC 107.2.1.4 | | | I SUGGEST YOU SPLIT THE BUILDING INTO 2 SECTIONS AND | | | EXPAND THE ISOMETRIC THE PIPING IS NOT SHOWN TO OVERLAP | | | EACH OTHER. | | | | | | 3. PLEASE SHOW THE PIPING FOR THE WASHING MACHINE ON | | | THE ISOMETRIC. PER WPB AMEND TO FBC 107.2.1 | | | | | | 4. SHT. P-10 THE NOTE THAT YOU ADDED " PROVIDE WATER | | | TEMPERATURE LIMITING DEVISE FOR LAVATORY'S TO PROVIDE | | | TEMPERED WATER" THE CODE ONLY REQUIRES TEMPERED WATER | | | AT PUBLIC LAVATORY'S THIS NOTE DOES NOT MEET THE CODE | | | REQUIREMENT FOR RESIDENTIAL FIXTURES THAT REQUIRE HOT | | | WATER MINIMUM OF 110DEG. PLEASE REMOVE NOTE. PER FBC PL | | | 607.1 | | | | | | 5. SHUT OFF VALVES FOR STACKABLE WASHING MACHINES SHALL | | | BE ACCESSIBLE. A NOTE ON THE PLAN WILL SUFFICE. PER FBC | | | PL 606.3 | | | | | | 6. THE DRAIN FOR THE ELEVATOR SHLL DRAIN THROUGH A | | | GREASE INTERCEPTOR OR HAVE AN OILMINDER SWITCH PLEASE | | | PROVIDE COMPLIANCE. PER FBC PL 1003.4 | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-06 |
Time |
11:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-05 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2017-09-06 12:17:22 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED 2ND | | | REQUEST | | | | | | 1. WHAT IS WORKFORCE HOUSING IS THIS PROJECT FEDERALLY | | | FUNDED. PER WPB AMEND TO FBC 107.2.1 | | | | | | 17. PROVIDE MANUFACTURE SPECIFICATIONS FOR SUB WATER | | | METER. PER WPB AMEND TO FBC 107.2.1 | | | | | | NEW COMMENTS: | | | | | | 1. SHT. A-6.5.1 THROUGH A-6.5.4 DETAIL 1 + 3 THE END OF | | | THE GRAB BAR BACKING SHALL LINE UP WITH THE FRONT OF | | | THE TUB. PER FHA DESIGN MANUAL PG 6.8-6.9 AS SHOWN ON | | | DIAGRAM | | | | | | 2. SHT. A-6.5.1 THROUGH A-6.5.4 DETAIL 2 THE TOP OF | | | GRAB BAR BACKING SHALL MEASURE 38" OF FINISHED FLOOR. | | | PER FHA DESIGN MANUAL PG 6.8-6.9 AS SHOWN ON DIAGRAM | | | | | | 3. SHT. A-6.5.1 THROUGH A-6.5.4 THE CENTER LINE OF THE | | | TOILET SHALL BE 18" OFF THE TUB OR WALL. FHA DESIGN | | | MANUAL PG 6.7 - 7.43 | | | | | | 4. PLEASE PROVIDE PLUMBING FIXTURE SCHEDULE. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 5. ALL FLOOR DRAINS SHALL HAVE A TRAP PRIMER VALVE THE | | | TRAP GUARD IS NOT APPROVED. PER FBC PL 1002.4 WHERE A | | | TRAP SEAL IS SUBJECT TO LOSS BY EVAPORATION, A TRAP | | | SEAL PRIMER VALVE SHALL BE INSTALLED. TRAP SEAL PRIMER | | | VALVES SHALL CONNECT TO THE TRAP AT A POINT ABOVE THE | | | LEVEL OF THE TRAP SEAL. A TRAP SEAL PRIMER VALVE SHALL | | | CONFORM TO ASSE 1018 OR ASSE 1044. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-30 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-29 |
Time |
15:30 |
Sent To |
|
|
| Notes |
| 2017-06-30 11:35:36 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. WHAT IS WORKFORCE HOUSING IS THIS PROJECT FEDERALLY | | | FUNDED. PER WPB AMEND TO FBC 107.2.1 | | | | | | 2, SHT. A-1.4 LABEL ROOF AREAS ON THE PLAN THAT YOU | | | REFERENCE IN YOU ROOF DRAIN CALCULATIONS. PER WPB AMEND | | | TO FBC 107.2.1 | | | | | | 3. PLEASE CLARIFY ON THE PLAN WHICH DESIGN | | | SPECIFICATION A OR B THAT YOU WILL BE USING ON EACH | | | UNIT. PER FHA | | | | | | 4. PLEASE INDICATE ON THE PLAN WHICH DOCUMENT THE FHA | | | DESIGN MANUAL OR THE FHA GUIDELINES FOUND IN FBC ACC, | | | YOU WILL BE USING TO DESIGN THE ELEMENTS TO COMPLY WITH | | | THE FHA . PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. SHOW THE CLEAR FLOOR SPACE FOR THE FIXTURES IN THE | | | BATHROOM AND KITCHEN. PER FHA | | | | | | 6. SHT. A-6.10 DETAIL 1.7 SHOWS A 20" X 4" SCUPPER | | | SHTA-1.4 THE SCUPPER IS SHOWN AT 6" X 12' PLEASE | | | CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 7. TRAP PRIMERS REQUIRED ON ALL FLOOR DRAINS. PER FBC | | | PL 1002.4 | | | | | | 8. PLEASE SHOW ON THE PLANS THE SQUARE FOOTAGE BEING | | | DRAINED BY EACH ROOF DRAIN . PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 9. TERMINATION OF THE PAN DRAINS SHALL COMPLY WITH FBC | | | PL 504.7.2 PAN DRAIN TERMINATION. | | | THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER | | | A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR FLOOR | | | DRAIN OR EXTEND TO THE EXTERIOR OF THE BUILDING AND | | | TERMINATE NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE | | | THAN 24 INCHES (610 MM) ABOVE THE ADJACENT GROUND | | | SURFACE. | | | | | | 10. PLEASE SHOW DETAIL OF KITCHEN RISER THE WAY IT IS | | | NOW I CAN NOT DETERMINE HOW YOU ARE DESIGNING IT. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 11. LABEL THE RISERS ON SHT P-8. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 12. PROVIDE DETAIL FOR FLUSHING RING ON TRASH-SHOOT . | | | PER WPB AMEND TO FBC 107.2.1 | | | | | | 13. SHOW FLUSHRING ON WATER RISER. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 14. PROVIDE MANUFACTURE SPECIFICATIONS FOR SUMP PIT | | | PUMP AND BOOSTER PUMPS. PER WPB AMEND TO FBC 107.2.1 | | | | | | 15. SHT. A-6.5.4 AND A-6.5.3 DETAIL B(L) B(R) IF YOU | | | ARE YOU ARE USING THE B SPECIFICATIONS FOR THESE UNITS | | | IT SHALL HAVE A CLEAR FLOOR SPACE FOR A PARALLEL | | | APPROACH TO THE TUB. PER FHA | | | | | | 16. THE BACKING FOR THE GRAB BAR ON THE SIDE WALL OF | | | THE TUB SHALL START 6" MAX FROM THE TOP OF THE TUB AND | | | EXTEND UP TO A MIN OF 38" OFF THE FLOOR. PER FHA | | | | | | 17. PROVIDE MANUFACTURE SPECIFICATIONS FOR SUB WATER | | | METER. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
| Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2017-07-17 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-17 |
Time |
10:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-17 |
Time |
10:17 |
Sent To |
|
|
| Notes |
| 2017-07-17 10:25:36 | NOA 15-1026.04 SUBMITTED | | | THE ASSEMBLY PROPOSED WAS NOT INDICATED | | | PRIOR TO ROOF COMMENCEMENT, A SEPARATE PERMIT IS | | | REQUIRED. ROOF PERMIT APPLICANT IS TO SELECT ASSEMBLY | | | PROPOSED. A ROOF REVIEW WILL BE REQUIRED AT THAT TIME. | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2017-11-03 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-11-03 |
Time |
16:10 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-03 |
Time |
16:10 |
Sent To |
|
|
| Notes |
| 2017-11-03 16:17:28 | | | | ART LANGE - BUILDING PLANS EXAMINER | | | 561-805-6667 [email protected] | | | FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA | | | RESIDENTIAL CODE 2015 5TH EDITION | | | | | | RECEIVED SPECIAL INSPECTOR AGGREEMENT: | | | | | | PAUL DANFORTH PE SI PE 44653 THRESHOLD INSPECTOR SI | | | 1103 | | | | | | NOEL WOODALL BN 2505, PX 1224 | | | | | | CARLTON CROOK BN 3909 | | | | | | PROVIDED A COPY OF THE AGREEMENT TO KEN CONRAD. |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-14 |
Time |
15:23 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-14 |
Time |
15:23 |
Sent To |
|
|
| Notes |
| 2017-07-14 15:24:33 | ****CORRECTIONS**** | | | PROVIDE AN EMAIL ADDRESS; SI AGREEMENT AND POLICY WILL | | | BE SENT VIA EMAIL | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | | PLACE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL | | | INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER | | | INFORMATION BEFORE THE PERMIT MAY BE ISSUED. | | | | | | C) THRESHOLD BLDG., REQUIRED STATEMENT W.P.B. AMENDMENT | | | 110.3.7.4.4, FS553.79(7)(D): ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT?S OR ENGINEER?S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE | | | FIRESAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS CHAPTER AND CHAPTER | | | 633. | | | | | | W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONSTRUCTION. | | | | | | F) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, | | | PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING | | | ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE | | | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR | | | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN | | | COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR | | | THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE | | | IN BLACK & WHITE. | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD | | | BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS | | | CONCERNING SPECIAL INSPECTORS. | | | | | | G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | | DOCUMENTS BY THE CONTRACTOR. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-08-18 |
Time |
16:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-06-16 |
Time |
08:33 |
Sent To |
|
|
| Notes |
|
|