Plan Review Details - Permit 17060189
Plan Review Stops For Permit 17060189
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2017-11-28 Cont ID  
Sent By aclange Date 2017-11-28 Time 14:34 Rev Time 0.00
Received By aclange Date 2017-11-28 Time 14:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-11-03 Cont ID  
Sent By aclange Date 2017-11-03 Time 16:18 Rev Time 0.00
Received By aclange Date 2017-11-03 Time 11:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-09-13 Cont ID  
Sent By shill Date 2017-09-13 Time 16:05 Rev Time 0.00
Received By shill Date 2017-08-30 Time 10:43 Sent To  
Notes
2017-09-13 16:05:18****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 17060191 APARTMENT BUILDING #
 17060189 APARTMENT BUILDING, 2191 N AUSTRALIAN AVE (SIX
 STORY)
 17060192 CLUBHOUSE BUILDING
  
 COMMENTS FROM PREVIOUS REVIEW; UNABLE TO LOCATE A
 RESPONSE LETTER; EMAILED APPLICANT.
  
 1-2. OK
  
 3. ADDRESS PLUMBING COMMENTS REGARDING FAIR HOUSING AS
 THEY ARE APPLICABLE FOR BUILDING REVIEW.
  
 4. FBC B 1803, PROVIDE THE GEOTECHNICAL INVESTIGATION
 REPORT. 2ND REQUEST.
  
 5-8. OK
  
 9. FBC B 1207.2, 1207.3, REVISE COVER PAGE TO INCLUDE
 FLOORING UNDERLAYMENT AS AN ITEM TO BE SUBMITTED AT A
 LATER TIME.
  
 12-13. OK
  
 14. THIS PERMIT WILL BE ISSUED WITH PROVISOS:
  
 A. SEPARATE PERMITS REQUIRED FOR FENCING, SITE WALLS,
 SIGNAGE, PARKING LOT/PAVING, DUMPSTER ENCLOSURE.
  
 B. FLOORING UNDERLAYMENT TEST REPORTS (STC, IIC, FLAME
 SPREAD) REQUIRED TO BE SUBMITTED PRIOR TO INSTALLATION.
  
 C. SEPARATE ROOF PERMIT REQUIRED. NOA 15-1026.04 WAS
 SUBMITTED; WHEN SUBMITTING ROOF PERMIT APPLICATION,
 INDICATE ASSEMBLY PROPOSED AND PROVIDE ENGINEERING IF
 REQUIRED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-07-17 Cont ID  
Sent By shill Date 2017-07-17 Time 15:35 Rev Time 0.00
Received By shill Date 2017-07-14 Time 15:21 Sent To  
Notes
2017-07-17 15:35:43****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 17060191 APARTMENT BUILDING #
 17060189 APARTMENT BUILDING A (SIX STORY)
 17060192 CLUBHOUSE BUILDING
  
 1. ALL PAGES HAVE AN INCORRECT ADDRESS AND NOT ALL ARE
 CONSISTENT WITH EACH OTHER (DIFFERENT INCORRECT
 ADDRESSES). FBC 107, PLEASE CORRECT THE ADDRESS ON EACH
 PAGE.
  
 2. FS471.0195, THE DBPR RECORD FOR THE FOLLOWING
 ENGINEER(S) DO NOT REFLECT THAT THE ADVANCED FLORIDA
 BUILDING CODE COURSE HAS BEEN COMPLETED. EMAIL THE
 CERTIFICATE TO FBPE AND REQUEST THAT THE DBPR RECORD BE
 UPDATED. NOTE THAT IT IS POSSIBLE THAT THE COURSE WAS
 COMPLETED AND THE WEBSITE IS NOT CURRENT.
  
 SANTIAGO ARANEGUI, PE
 JOE SPASOVSKI, PE
  
 PERMIT ISSUANCE WILL NOT BE DELAYED DUE TO THIS
 COMMENT. HOWEVER, FLORIDA STATUTE REQUIRES THAT:
 LOCAL JURISDICTIONS SHALL BE RESPONSIBLE FOR NOTIFYING
 THE BOARD WHEN DESIGN DOCUMENTS ARE SUBMITTED FOR
 BUILDING CONSTRUCTION PERMITS BY PERSONS WHO ARE NOT IN
 COMPLIANCE WITH THIS SECTION.
  
 3. ADDRESS OTHER TRADES' COMMENTS REGARDING FAIR
 HOUSING AS THEY ARE APPLICABLE FOR BUILDING REVIEW.
  
 4. FBC B 1803, PROVIDE THE GEOTECHNICAL INVESTIGATION
 REPORT. THIS IS AREA IS KNOWN TO HAVE THE POTENTIAL OF
 POOR SOILS.
  
 5. SECTION 5-A6.6.2, REVISE PLAN TO SHOW FRT (LUMBER)
 OR REVISE PLAN TO INCLUDE APPLICABLE EXCEPTION, FBC B
 602. REVISE OTHER LOCATIONS WHICH SHOW WOOD (SUCH AS
 MUTIPLE DETAILS, S3.5).
  
 6. S1.0, ROOF LIVE LOAD IS 20PSF; FBC B TABLE 1607.1
 REQUIRES 300 CONCENTRATED FOR "ALL ROOF SURFACES
 SUBJECT TO MAINTENANCE WORKERS". RTU EQUIPMENT SHOWN.
 EITHER REVISE DESIGN CRITERIA FOR THIS ROOF SECTION OR
 PROVIDE RATIONALE FOR 20PSF LIVE LOAD.
  
 7. IT APPEARS THAT NOT ALL LAP SPLICES WERE SPECIFIED
 ON THE PLAN FOR THE FOUNDATION; REVISE PLAN OR ADVISE
 WHERE THIS CAN BE LOCATED, FBC 107, FBC B CHAPTER 19.
  
 8. FBC B 420.3, PROVIDE A DETAIL SHOWING COMPLIANCE
 WITH THE 1 HOUR SEPARATION REQUIREMENT FOR THE
 FLOOR/CEILING ASSEMBLIES BETWEEN UNITS. REVISE THE PLAN
 TO SHOW THE 1 HOUR (MINIMUM) FLOOR/CEILING ASSEMBLY.
  
 9. FBC B 1207.2, 1207.3, PROVIDE TEST REPORTS FOR THE
 FLOORING UNDERLAYMENT (STC/IIC). REVISE PLAN TO INCLUDE
 REQUIREMENT FOR ACOUSTIC INSULATION. NOTE THAT SPEC
 SHEETS ARE NOT ACCEPTABLE; ACTUAL TEST REPORTS ARE
 REVIEWED. IT IS LIKELY THAT THE MANUFACTURER WILL BE
 REQUIRED TO DO A COMPARATIVE ANALYSIS AS IT IS UNLIKELY
 THAT THE UNDERLAYMENT WAS TESTED WITH HOLLOW CORE (MOST
 TESTS ARE DONE WITH A CONCRETE SLAB).
  
 CSM CRACK SUPPRESSION & SOUND CONTROL SPEC SHEET WAS
 PROVIDED. PLEASE SEND TEST REPORTS VIA EMAIL FOR
 PRELIMINARY REVIEW. WHEN REVISING PLAN TO INCLUDE
 UNDERLAYMENT REQUIREMENT, IT IS ADVISED THAT YOU DO NOT
 SPEC A PRODUCT.
  
 10. FBC 720.2, PROVIDE A COPY OF THE FLAME SPREAD TEST
 FOR THE PROPOSED FLOORING UNDERLAYMENT.
  
 11. AS THIS IS NEW CONSTRUCTION, APPLY FOR AN
 ENGINEERING PERMIT; 561-494-1040. ENGINEERING
 DEPARTMENT APPROVAL IS REQUIRED PRIOR TO PERMIT
 ISSUANCE. CONTACT THEM DIRECTLY REGARDING REQUIREMENTS.
 IF YOU HAVE ALREADY APPLIED, PROVIDE THE APPLICATION
 NUMBER. I WAS UNABLE TO LOCATE AN ENGINEERING
 APPLICATION FOR THIS PARCEL ID.
  
 HTTP://WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS/FOR
 MS,-PERMITS-APPLICATIONS
  
 12. A SEPARATE ROOF PERMIT IS REQUIRED. A ROOF PRODUCT
 APPROVAL WAS SUBMITTED, FIBERTITE SINGLE PLY ROOF
 SYSTEMS OVER LIGHTWEIGHT CONCRETE DECKS (NOA
 15-1026.04).
  
 FBC 1609, AT THIS TIME, APPLICANT MAY INDICATE WHICH
 APPROVED ASSEMBLY IS PROPOSED. IF THIS IS DONE NOW, THE
 ROOF SUB PERMIT WILL BE ISSUED WITHOUT ANY OTHER
 INFORMATION REQUIRED.
  
 IF APPLICANT DOES NOT PROVIDE THIS INFORMATION AT THIS
 TIME, THIS PERMIT WILL BE ISSUED WITH PROVISO THAT, AT
 TIME OF ROOF SUB PERMIT APPLICATION, THE APPROVED
 ASSEMBLY IS TO BE SELECTED. A PLAN REVIEW WILL BE
 REQUIRED AT THAT TIME.
  
 13. WHEN AVAILABLE, PROVIDE A COPY OF THE CONTRACT FOR
 THE THREE PROPOSED BUILDINGS, FBC 109.
  
 14. THIS PERMIT WILL BE ISSUED WITH PROVISOS:
  
 A. SEPARATE PERMITS REQUIRED FOR FENCING, SITE WALLS,
 SIGNAGE, PARKING LOT/PAVING, DUMPSTER ENCLOSURE,
  
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2017-11-03 Cont ID  
Sent By jpearson Date 2017-11-03 Time 09:17 Rev Time 0.00
Received By jpearson Date 2017-11-03 Time 09:17 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-09-05 Cont ID  
Sent By jpearson Date 2017-09-05 Time 12:29 Rev Time 0.00
Received By jpearson Date 2017-09-05 Time 12:29 Sent To  
Notes
2017-09-05 12:29:49CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2014 5TH EDITION
 FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014
 5TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION,
 PART VIII ELECTRICAL
 NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. ADDRESS NUMBER ON PERMIT APPLICATION IS 2191, ON
 COVER SHEET IS 2181, AND ON ELECTRICAL SHEETS IS 2180.
 PROVIDE CORRECT ADDRESS ON PLANS. FBC 107.2.1
 2. SHEET E-8 SHOWS 6 SETS OF 750 KCMIL CU FOR SERVICE
 FEEDERS, WHILE SHEET E-6 SHOWS 7 SETS OF 600 KCMIL CU.
 CORRECT DISCREPANCY. FBC 107.2.1
 3. LOAD CALCULATION FOR MDP SHOWS SEVERAL DIFFERENT
 CALCULATIONS (ONE STORY, TWO STORY, ETC.). PROVIDE LOAD
 CALCULATION RELATED TO THIS PERMIT ONLY FOR THE SIX
 STORY BUILDING. REMOVE ALL OTHER UNRELATED INFORMATION.
 ADDITIONALLY, THE LOAD VA SHOWN FOR THE 1 BEDROOM UNIT
 IS THE SAME AS FOR THE 2 BEDROOM UNIT. LOAD CALCULATION
 FOR PANEL H IS DIFFERENT THAN LISTED IN PANEL SCHEDULE.
 PROVIDE CORRECTIONS. NEC 220; FBC 107.2.1
 4. PANEL H SHOWS A JOCKEY PUMP ON CIRCUIT 19, 21, 23.
 IS THIS THE JOCKEY PUMP FOR THE FIRE PUMP SYSTEM? IF
 SO, THIS CANNOT BE FEED FROM PANEL H. THE JOCKEY PUMP
 SPECIFIED ON SHEET FP 2.0 IS NOT SHOWN ON RISER DIAGRAM
 WITH FIRE PUMP. PROVIDE CORRECTION. NEC 215.5,
 695.4(B)(3); FBC 107.2.1
 5. FIRE PUMP SERVICE IS NOT LABELED AS ONE OF THE MAINS
 FOR THE BUILDING. PROVIDE CORRECTION. NEC 230.2(E)
 6. PANEL H LOAD CALCULATION STATES THAT THE FIRST 10K
 VA ARE AT 100%. HOWEVER, THE LOAD SHOWN IS 4320 VA, NOT
 10,000. PANEL H1 LOAD CALCULATION IS SIMILARLY WRONG.
 PROVIDE CORRECTION. NEC 220.44
 7. PROVIDE DETAILS OF SECOND POWER SOURCE REQUIRED FOR
 FIRE PUMP. NEC 695.3(B)
 8. PROVIDE LOAD CALCULATION FOR FIRE PUMP CONTROLLER
 AND ASSOCIATED EQUIPMENT TO VERIFY FEEDER, GROUNDING,
 AND OVERCURRENT PROTECTION REQUIREMENTS. NEC 695.6
 9. PLAN STATES THAT THE LOCKED ROTOR CURRENT FOR THE
 FIRE PUMP MOTOR IS 32.2 AMPS. ACCORDING TO TABLE
 430.251(B), THE LOCKED ROTOR CURRENT FOR A MOTOR THIS
 SIZE SHOULD BE 179 AMPS. PROVIDE CORRECTION. NEC TABLE
 430.251(B); FBC 107.2.1
 10. PLAN INCLUDES ELECTRICAL PLAN FOR 1ST FLOOR, 4TH
 FLOOR, AND ROOF ONLY. PROVIDE FULL SET OF PLANS FOR
 REVIEW. FBC 107.2.1, 107.3.5
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-07-03 Cont ID  
Sent By jleahy Date 2017-07-03 Time 15:17 Rev Time 0.00
Received By jleahy Date 2017-07-03 Time 15:17 Sent To  
Notes
2017-07-03 15:29:16FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH ED
 NFPA 70 2011 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 PAGE E-6 NEED TO SIZE THE FIRE PUMP AND CONTROLER
  
 PAGE E-6 NEED TO SUPPLY AN INTYERSYSTEM BONDING STRIP
 AT EAC SERVICE LOCATION PER 250.94
  
 PAGE E-8 NO SITE LIGHT CIRCUITS SHOWN, ARE THERE ANY
 FIXTURES ON THE BUILDING?

Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2017-10-05 Cont ID  
Sent By squinone Date 2017-10-05 Time   Rev Time 0.00
Received By squinone Date 2017-10-05 Time   Sent To  
Notes
2017-10-05 15:44:261) NO CIVIL PLANS WERE INCLUDED WITH THIS SUBMITTAL.
 CIVIL PLANS ARE UNDER REVIEW THROUGH ENGINEERING PLAN
 REVIEW, E17060013.

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2017-07-17 Cont ID  
Sent By shill Date 2017-07-17 Time 08:10 Rev Time 0.00
Received By shill Date 2017-07-17 Time 08:10 Sent To  
Notes
2017-07-17 08:10:43CONTACT ENGINEERING DEPARTMENT DIRECTLY AND SUBMIT
 APPLICATION IF REQUIRED
 HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS
 /FORMS,-PERMITS-APPLICATIONS
  
 ENGINEERING APPROVAL REQUIRED PRIOR TO PERMIT ISSUANCE
  
 MAIN PHONE: (561) 822-1200
  
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2017-10-25 Cont ID  
Sent By wjolin Date 2017-10-25 Time 10:17 Rev Time 0.00
Received By wjolin Date 2017-10-25 Time 10:12 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-08-18 Cont ID  
Sent By wjolin Date 2017-08-18 Time 09:25 Rev Time 0.00
Received By wjolin Date 2017-08-16 Time 16:06 Sent To  
Notes
2017-08-18 09:18:002181 NORTH AUSTRALIAN AVENUE - 6 STORY APARTMENTS
 PERMIT #17060189
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 CIVIL SHEET 2 OF 14: PROVIDE A FIRE DEPARTMENT KNOX KEY
 SWITCH TO ALLOW EMERGENCY RESPONSE VEHICLES ACCESS INTO
 THE PROPERTY. BOTH GATES SHALL FUNCTION SIMULTANEOUSLY.
  
 CIVIL SHEET 6 OF 14: A POST INDICATOR VALVE (PIV) WILL
 BE NEEDED TO ISOLATE EACH FIRE PROTECTION SERVICE MAIN
 ENTERING EACH BUILDING.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-06-21 Cont ID  
Sent By wjolin Date 2017-06-21 Time 13:50 Rev Time 0.00
Received By wjolin Date 2017-06-21 Time 12:15 Sent To  
Notes
2017-06-21 12:16:092181 NORTH AUSTRALIAN AVENUE - 6 STORY APARTMENTS
 PERMIT #17060189
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 NO CIVIL PLANS SUBMITTED.
  
 PER NFPA 241 SECTION 8.7.2.3, WHERE UNDERGROUND WATER
 MAINS AND HYDRANTS ARE TO BE PROVIDED, THEY SHALL BE
 INSTALLED, TESTED, APPROVED, AND IN SERVICE PRIOR TO
 VERTICAL CONSTRUCTION WORK.
  
 WILL ANY CONSTRUCTION TRAILERS BE LOCATED ON SITE? THE
 CITY OF WEST PALM BEACH REQUIRES CONSTRUCTION TRAILERS
 LARGER THAN A SINGLE "DOUBLE WIDE" (OR TWO "SINGLE
 WIDE") TO EITHER BE PROTECTED BY AN AUTOMATIC SPRINKLER
 SYSTEM OR COMPLY WITH THE SEPARATION REQUIREMENTS OF
 NFPA 241. TEMPORARY CONSTRUCTION TRAILERS OR MODULAR
 BUILDINGS WILL REQUIRE A PERMIT AND COMPLIANCE WITH THE
 FOLLOWING:
 PER NFPA 241- STANDARD FOR SAFEGUARDING CONSTRUCTION,
 ALTERATION, AND DEMOLITION OPERATIONS, SECTION 4.2:
 TEMPORARY OFFICES, TRAILERS, AND OTHER FACILITIES OF
 COMBUSTIBLE CONSTRUCTION OR HOUSING COMBUSTIBLE
 CONTENTS SHALL BE SEPARATED FROM ADJACENT BUILDINGS,
 TRAILERS OR STRUCTURES IN ACCORDANCE WITH TABLE 4.2.1.
 PER TABLE 4.2.1:
 1) 20 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 30 FEET
 2) 30 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 35 FEET
 3) 40 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 40 FEET
 4) 50 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 45 FEET
 5) 60 FEET EXPOSED LENGTH SHALL BE SEPARATED FROM
 ADJACENT STRUCTURES BY AT LEAST 50 FEET
 6) GREATER THAN 60 FEET EXPOSED LENGTH SHALL BE
 SEPARATED FROM ADJACENT STRUCTURES BY AT LEAST 60 FEET
 **A 75 PERCENT REDUCTION IN SEPARATION DISTANCES SHALL
 BE PERMITTED TO BE APPLIED, PROVIDED AUTOMATIC
 SPRINKLER PROTECTION IS USED IN THE EXPOSING STRUCTURE.
  
 PER NFPA 241 SECTION 4.2.2: DETACHMENT BETWEEN
 TEMPORARY STRUCTURES, ADEQUATE TEMPORARY FIXED FIRE
 PROTECTION SYSTEMS, AND PORTABLE EQUIPMENT SHALL BE
 PROVIDED AS REQUIRED BY THE AUTHORITY HAVING
 JURISDICTION.
  
 PLANS INDICATE AN ADDRESS OF 2181; HOWEVER, THE PERMIT
 APPLICATION INDICATES THE ADDRESS TO BE 2191 NORTH
 AUSTRALIAN AVENUE.
  
 SHEET A-6.9.2: PER NFPA 101 SECTION 7.2.2.6.2 VISUAL
 PROTECTION. OUTSIDE STAIRS SHALL BE ARRANGED TO AVOID
 ANY IMPEDIMENTS TO THEIR USE BY PERSONS HAVING A FEAR
 OF HIGH PLACES. OUTSIDE STAIRS MORE THAN 36 FEET ABOVE
 THE FINISHED GROUND LEVEL SHALL BE PROVIDED WITH AN
 OPAQUE VISUAL OBSTRUCTION NOT LESS THAN 48-INCHES IN
 HEIGHT.
  
 WESLEY JOLIN
 ASSISTANT FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2017-12-21 Cont ID  
Sent By aclange Date 2017-12-21 Time 13:06 Rev Time 0.00
Received By aclange Date 2017-12-20 Time 09:11 Sent To  
Notes
2017-12-21 09:11:49IMPACT FEES ROUTED TO ACLANGE

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-11-28 Cont ID  
Sent By aclange Date 2017-11-28 Time 14:34 Rev Time 0.00
Received By aclange Date 2017-11-16 Time 12:03 Sent To  
Notes
2017-11-16 12:04:12GJOHNSTON'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-11-03 Cont ID  
Sent By aclange Date 2017-11-03 Time 16:18 Rev Time 0.00
Received By aclange Date 2017-10-19 Time 08:08 Sent To  
Notes
2017-10-20 08:12:10C31

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-10-11 Cont ID  
Sent By shill Date 2017-10-11 Time 08:38 Rev Time 0.00
Received By shill Date 2017-08-07 Time 15:40 Sent To  
Notes
2017-08-07 15:40:40C31

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-07-17 Cont ID  
Sent By shill Date 2017-07-17 Time 15:35 Rev Time 0.00
Received By shill Date 2017-06-05 Time 13:49 Sent To  
Notes
2017-06-06 13:49:21C30

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status P Date 2017-12-21 Cont ID  
Sent By aclange Date 2017-12-21 Time 12:46 Rev Time 0.00
Received By aclange Date 2017-12-21 Time 11:48 Sent To  
Notes
2017-12-21 12:49:47PALM BEACH COUNTY IMPACT FEES PAID. $527,017.05
 RECEIPT NO: 2017-1220-331
 12/20/2017

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2017-11-28 Cont ID  
Sent By aclange Date 2017-11-28 Time 14:33 Rev Time 0.00
Received By aclange Date 2017-11-28 Time 14:33 Sent To  
Notes
2017-11-28 14:34:01****PLAN REVIEW COMMENTS****
  
 ART LANGE - BUILDING INSPECTOR
 561-805-6667 [email protected]
 FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA
 RESIDENTIAL CODE 2015 5TH EDITION
  
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2017-11-03 Cont ID  
Sent By aclange Date 2017-11-03 Time 16:08 Rev Time 0.00
Received By aclange Date 2017-11-03 Time 16:08 Sent To  
Notes
2017-11-03 16:09:57****PLAN REVIEW COMMENTS****
  
 ART LANGE - BUILDING INSPECTOR
 561-805-6667 [email protected]
 FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA
 RESIDENTIAL CODE 2015 5TH EDITION
  
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-07-14 Cont ID  
Sent By shill Date 2017-07-14 Time 15:21 Rev Time 0.00
Received By shill Date 2017-07-14 Time 15:21 Sent To  
Notes
2017-07-14 15:22:54****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED.
  
 THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING
 THAT FEES DUE WERE PAID, IF APPLICABLE, IS TO BE
 PROVIDED.
  
 561-233-5025 FOR MORE INFORMATION.
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-10-31 Cont ID  
Sent By ccole Date 2017-10-31 Time 10:08 Rev Time 0.00
Received By ccole Date 2017-10-30 Time 17:34 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-09-06 Cont ID  
Sent By ccole Date 2017-09-06 Time 09:52 Rev Time 0.00
Received By ccole Date 2017-09-06 Time 07:24 Sent To  
Notes
2017-09-06 10:13:282ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17060189
 9/6/17
  
 1) THE ENERGYGAUGE SUMMIT IECC COMPLIANCE FORM DOES NOT
 INCLUDE DATA FOR THE ACCU- AHU #1, 2, & 3 SYSTEM.
  
 2) PLEASE SEE COMMENT #3 FROM THE 1ST REVIEW AND
 SECTION C407.5.2.3 FBC-14 ENERGY CONSERVATION- PROVIDE
 AC CALCULATIONS USING ONE THERMAL BLOCK PER SPACE, OR
 ONE THERMAL BLOCK FOR MULTIPLE SPACES THAT ARE FACING
 THE SAME ORIENTATIONS. PLEASE NOTE THAT CORNER UNITS
 AND UNITS WITH ROOFS OR FLOOR LOADS SHALL ONLY BE
 COMBINED WITH UNITS SHARING THE SAME FEATURES. IN
 ADDITION
  
 PLEASE REFER TO SECTION C403.2.1: DESIGN LOADS SHALL BE
 DETERMINED IN ACCORDANCE WITH THE PROCEDURES DESCRIBED
 IN THE ASHRAE/ACCA STANDARD 183 OR ACCA MANUAL N AND
 SHALL BE ATTACHED TO THE CODE COMPLIANCE FORM SUBMITTED
 TO THE BUILDING DEPARTMENT.
  
 3) M-4: PLEASE ENLARGE THE AC EQUIPMENT SCHEDULE FOR
 THE APARTMENT UNITS AND NUMBER THEM AS EITHER AC-1 OR 2
 AS THEY ARE SHOWN ON THE DRAWINGS.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-07-03 Cont ID  
Sent By ccole Date 2017-07-03 Time 09:33 Rev Time 0.00
Received By ccole Date 2017-06-30 Time 16:47 Sent To  
Notes
2017-07-03 09:55:191ST REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION
 PERMIT #17060189
 7/3/17
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE LOUVERED AC CLOSETS DOORS SHALL BE
 NON-COMBUSTIBLE PER SECTION C403.2.7.2 FBC-14 ENERGY
 CONSERVATION. THE DOOR SCHEDULE ON SHEET A-8.1
 INDICATES WOOD DOORS.
  
 2) THE SUBMITTED ENERGYGAUGE FORM R405-2014 IS A
 RESDIENTIAL COMPLIANCE FORM, HOWEVER THE PROPOSED
 PROJECT IS A COMMERCIAL BUILDING- SEE SECTION C202 &
 R202 DEFINITIONS FBC-14 ENERGY CONSERVATION. PLEASE SEE
 SECTIONS C101.5 & C407.4.1 AND SUBMIT A COMMERCIAL
 COMPLIANCE FORM.
  
 3) THE SUBMITTED ENERGYGAUGE FORM R405-2014 IS
 SPECIFYING A WORST CASE METHOD, HOWEVER THAT METHOD IS
 NOT APPLICABLE TO A COMMERCIAL BUILDING PROJECT. PLEASE
 SEE SECTIONS C407.4.2- C407.5.2.3 FOR THERMAL ZONING
 BLOCKS USING DEFINED HVAC ZONES ON THE PLANS, OR
 UNDEFINED ZONES.
  
 4) SHEET M-3: CONTRARY TO THE NOTE ON THE ROOF PLAN
 THERE ARE NO STRUCTURAL DETAILS FOR MOUNTING THE AC
 STANDS AND CONDENSER TO THE ROOF STRUCTURE. PLEASE
 PROVIDE THE WIND LOAD DESIGN CRITERIA AND STRUCTURAL
 DETAILS PER SECTION 301.15 FBC-14 MECHANICAL.
 ADDITIONALLY, THE ENGINEER OF RECORD SHALL CIRCLE,
 HIGHLIGHT, OR OTHERWISE MARKUP THE AC STAND NOA TO SHOW
 THE APPLICABLE
 INSTALLATION DETAILS. PLEASE INDICATE THE STAND
 CONFIGURATION, STAND ANCHORING TO THE ROOF, AND
 CONDENSER ANCHORING TO THE STAND.
  
 5) PROVIDE MINIMUM VENTILATION CALCULATIONS FOR THE
 APARTMENTS IN COMPLIANCE WITH TABLE 403.3 OR TABLE 6-1
 ASHRAE 62.1. INDICATE THE REQUIRED AND PROVIDE
 VENTILATION RATES.
  
 6) PROVIDE MINIMUM VENTILATION CALCULATIONS AND
 VENTILATION PLANS FOR THETRASH COMPACTOR ROOM, THE
 ELECTRICAL ROOMS, AND THE PUMP ROOM- SEE TABLE 403.3.
 PLEASE NOTE THAT TABLE 6-4 ASHRAE 62.1 REQUIRES AN
 EXHAUST SYSTEM FOR THE TRASH COMPACTOR ROOM DESIGNED AT
 A RATE OF 1 .00 CFM PER SQ. FT.
  
 7) INDICATE HOW THE ELEVATOR HOISTWAY WILL BE VENTED IN
 ACCORDANCE WITH SECTION 3004 FBC-14 BUILDING.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 4 Status P Date 2017-11-28 Cont ID  
Sent By gjohnson Date 2017-11-28 Time 08:52 Rev Time 0.00
Received By gjohnson Date 2017-11-28 Time 08:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status F Date 2017-11-01 Cont ID  
Sent By gjohnson Date 2017-11-01 Time 14:44 Rev Time 0.00
Received By gjohnson Date 2017-11-01 Time 14:44 Sent To  
Notes
2017-11-01 17:10:213RD REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. SHT. A - 6.5.1 - A -6.5.4 FHA REQUIREMENTS.
  
 A) THE GRAB BAR WOULD MOUNTED ON THE OPPOSITE SIDE OF
 THE TOILET FROM THE APPROACH WHICH WOULD BE HE TUB SIDE
 WHICH WOULD REQUIRE THE 18" REQUIRED CLEARANCE TO BE ON
 THE TUB SIDE NOT VANITY SIDE. PER FHA DESIGN MANUAL PG.
 6.5 - 6.7
 B) THE BOTTOM OF THE BACKING ON THE SIDE WALL OF THE
 TUB SHALL BE 6"MAX FROM TOP OF TUB. PER FHA DESIGN
 MANUAL PG. 6.9
 C) SHOW THE CLEAR FLOOR SPACE FOR THE TOILET. PER FHA
 DESIGN MANUAL PG. 7.43
 D) THE VANITY SHALL HAVE A MAXIMUM DEPTH OF 24". PER
 FHA DESIGN MANUAL PG.7.43
  
 2. THE SANITARY ISOMETRIC DRAWING IS TO COMPACT AND TO
 CONGESTED IT MAKES IT EXTREMELY HARD TO READ AND WHEN
 IT IS SCANNED FOR OUR RECORDS IT WILL BE WORSE, THE MIN
 REQUIREMENT FOR PLANS IS 1/8IN. SCALE PER WPB AMEND TO
 FBC 107.2.1.4
 I SUGGEST YOU SPLIT THE BUILDING INTO 2 SECTIONS AND
 EXPAND THE ISOMETRIC THE PIPING IS NOT SHOWN TO OVERLAP
 EACH OTHER.
  
 3. PLEASE SHOW THE PIPING FOR THE WASHING MACHINE ON
 THE ISOMETRIC. PER WPB AMEND TO FBC 107.2.1
  
 4. SHT. P-10 THE NOTE THAT YOU ADDED " PROVIDE WATER
 TEMPERATURE LIMITING DEVISE FOR LAVATORY'S TO PROVIDE
 TEMPERED WATER" THE CODE ONLY REQUIRES TEMPERED WATER
 AT PUBLIC LAVATORY'S THIS NOTE DOES NOT MEET THE CODE
 REQUIREMENT FOR RESIDENTIAL FIXTURES THAT REQUIRE HOT
 WATER MINIMUM OF 110DEG. PLEASE REMOVE NOTE. PER FBC PL
 607.1
  
 5. SHUT OFF VALVES FOR STACKABLE WASHING MACHINES SHALL
 BE ACCESSIBLE. A NOTE ON THE PLAN WILL SUFFICE. PER FBC
 PL 606.3
  
 6. THE DRAIN FOR THE ELEVATOR SHLL DRAIN THROUGH A
 GREASE INTERCEPTOR OR HAVE AN OILMINDER SWITCH PLEASE
 PROVIDE COMPLIANCE. PER FBC PL 1003.4
  
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-09-06 Cont ID  
Sent By gjohnson Date 2017-09-06 Time 11:37 Rev Time 0.00
Received By gjohnson Date 2017-09-05 Time 16:07 Sent To  
Notes
2017-09-06 12:17:222ND REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED 2ND
 REQUEST
  
 1. WHAT IS WORKFORCE HOUSING IS THIS PROJECT FEDERALLY
 FUNDED. PER WPB AMEND TO FBC 107.2.1
  
 17. PROVIDE MANUFACTURE SPECIFICATIONS FOR SUB WATER
 METER. PER WPB AMEND TO FBC 107.2.1
  
 NEW COMMENTS:
  
 1. SHT. A-6.5.1 THROUGH A-6.5.4 DETAIL 1 + 3 THE END OF
 THE GRAB BAR BACKING SHALL LINE UP WITH THE FRONT OF
 THE TUB. PER FHA DESIGN MANUAL PG 6.8-6.9 AS SHOWN ON
 DIAGRAM
  
 2. SHT. A-6.5.1 THROUGH A-6.5.4 DETAIL 2 THE TOP OF
 GRAB BAR BACKING SHALL MEASURE 38" OF FINISHED FLOOR.
 PER FHA DESIGN MANUAL PG 6.8-6.9 AS SHOWN ON DIAGRAM
  
 3. SHT. A-6.5.1 THROUGH A-6.5.4 THE CENTER LINE OF THE
 TOILET SHALL BE 18" OFF THE TUB OR WALL. FHA DESIGN
 MANUAL PG 6.7 - 7.43
  
 4. PLEASE PROVIDE PLUMBING FIXTURE SCHEDULE. PER WPB
 AMEND TO FBC 107.2.1
  
 5. ALL FLOOR DRAINS SHALL HAVE A TRAP PRIMER VALVE THE
 TRAP GUARD IS NOT APPROVED. PER FBC PL 1002.4 WHERE A
 TRAP SEAL IS SUBJECT TO LOSS BY EVAPORATION, A TRAP
 SEAL PRIMER VALVE SHALL BE INSTALLED. TRAP SEAL PRIMER
 VALVES SHALL CONNECT TO THE TRAP AT A POINT ABOVE THE
 LEVEL OF THE TRAP SEAL. A TRAP SEAL PRIMER VALVE SHALL
 CONFORM TO ASSE 1018 OR ASSE 1044.
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-06-30 Cont ID  
Sent By gjohnson Date 2017-06-30 Time 10:55 Rev Time 0.00
Received By gjohnson Date 2017-06-29 Time 15:30 Sent To  
Notes
2017-06-30 11:35:361ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. WHAT IS WORKFORCE HOUSING IS THIS PROJECT FEDERALLY
 FUNDED. PER WPB AMEND TO FBC 107.2.1
  
 2, SHT. A-1.4 LABEL ROOF AREAS ON THE PLAN THAT YOU
 REFERENCE IN YOU ROOF DRAIN CALCULATIONS. PER WPB AMEND
 TO FBC 107.2.1
  
 3. PLEASE CLARIFY ON THE PLAN WHICH DESIGN
 SPECIFICATION A OR B THAT YOU WILL BE USING ON EACH
 UNIT. PER FHA
  
 4. PLEASE INDICATE ON THE PLAN WHICH DOCUMENT THE FHA
 DESIGN MANUAL OR THE FHA GUIDELINES FOUND IN FBC ACC,
 YOU WILL BE USING TO DESIGN THE ELEMENTS TO COMPLY WITH
 THE FHA . PER WPB AMEND TO FBC 107.2.1
  
 5. SHOW THE CLEAR FLOOR SPACE FOR THE FIXTURES IN THE
 BATHROOM AND KITCHEN. PER FHA
  
 6. SHT. A-6.10 DETAIL 1.7 SHOWS A 20" X 4" SCUPPER
 SHTA-1.4 THE SCUPPER IS SHOWN AT 6" X 12' PLEASE
 CLARIFY. PER WPB AMEND TO FBC 107.2.1
  
 7. TRAP PRIMERS REQUIRED ON ALL FLOOR DRAINS. PER FBC
 PL 1002.4
  
 8. PLEASE SHOW ON THE PLANS THE SQUARE FOOTAGE BEING
 DRAINED BY EACH ROOF DRAIN . PER WPB AMEND TO FBC
 107.2.1
  
 9. TERMINATION OF THE PAN DRAINS SHALL COMPLY WITH FBC
 PL 504.7.2 PAN DRAIN TERMINATION.
 THE PAN DRAIN SHALL EXTEND FULL-SIZE AND TERMINATE OVER
 A SUITABLY LOCATED INDIRECT WASTE RECEPTOR OR FLOOR
 DRAIN OR EXTEND TO THE EXTERIOR OF THE BUILDING AND
 TERMINATE NOT LESS THAN 6 INCHES (152 MM) AND NOT MORE
 THAN 24 INCHES (610 MM) ABOVE THE ADJACENT GROUND
 SURFACE.
  
 10. PLEASE SHOW DETAIL OF KITCHEN RISER THE WAY IT IS
 NOW I CAN NOT DETERMINE HOW YOU ARE DESIGNING IT. PER
 WPB AMEND TO FBC 107.2.1
  
 11. LABEL THE RISERS ON SHT P-8. PER WPB AMEND TO FBC
 107.2.1
  
 12. PROVIDE DETAIL FOR FLUSHING RING ON TRASH-SHOOT .
 PER WPB AMEND TO FBC 107.2.1
  
 13. SHOW FLUSHRING ON WATER RISER. PER WPB AMEND TO FBC
 107.2.1
  
 14. PROVIDE MANUFACTURE SPECIFICATIONS FOR SUMP PIT
 PUMP AND BOOSTER PUMPS. PER WPB AMEND TO FBC 107.2.1
  
 15. SHT. A-6.5.4 AND A-6.5.3 DETAIL B(L) B(R) IF YOU
 ARE YOU ARE USING THE B SPECIFICATIONS FOR THESE UNITS
 IT SHALL HAVE A CLEAR FLOOR SPACE FOR A PARALLEL
 APPROACH TO THE TUB. PER FHA
  
 16. THE BACKING FOR THE GRAB BAR ON THE SIDE WALL OF
 THE TUB SHALL START 6" MAX FROM THE TOP OF THE TUB AND
 EXTEND UP TO A MIN OF 38" OFF THE FLOOR. PER FHA
  
 17. PROVIDE MANUFACTURE SPECIFICATIONS FOR SUB WATER
 METER. PER WPB AMEND TO FBC 107.2.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status   Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2017-07-17 Cont ID  
Sent By shill Date 2017-07-17 Time 10:17 Rev Time 0.00
Received By shill Date 2017-07-17 Time 10:17 Sent To  
Notes
2017-07-17 10:25:36NOA 15-1026.04 SUBMITTED
 THE ASSEMBLY PROPOSED WAS NOT INDICATED
 PRIOR TO ROOF COMMENCEMENT, A SEPARATE PERMIT IS
 REQUIRED. ROOF PERMIT APPLICANT IS TO SELECT ASSEMBLY
 PROPOSED. A ROOF REVIEW WILL BE REQUIRED AT THAT TIME.
  
  

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 2 Status P Date 2017-11-03 Cont ID  
Sent By aclange Date 2017-11-03 Time 16:10 Rev Time 0.00
Received By aclange Date 2017-11-03 Time 16:10 Sent To  
Notes
2017-11-03 16:17:28 
 ART LANGE - BUILDING PLANS EXAMINER
 561-805-6667 [email protected]
 FBC FLORIDA BUILDING CODE 2014 5TH EDITION/ FRC FLORIDA
 RESIDENTIAL CODE 2015 5TH EDITION
  
 RECEIVED SPECIAL INSPECTOR AGGREEMENT:
  
 PAUL DANFORTH PE SI PE 44653 THRESHOLD INSPECTOR SI
 1103
  
 NOEL WOODALL BN 2505, PX 1224
  
 CARLTON CROOK BN 3909
  
 PROVIDED A COPY OF THE AGREEMENT TO KEN CONRAD.

Review Stop THRESHOLD THRESHOLD INSPECTOR DOCUMENTS
Rev No 1 Status F Date 2017-07-14 Cont ID  
Sent By shill Date 2017-07-14 Time 15:23 Rev Time 0.00
Received By shill Date 2017-07-14 Time 15:23 Sent To  
Notes
2017-07-14 15:24:33****CORRECTIONS****
 PROVIDE AN EMAIL ADDRESS; SI AGREEMENT AND POLICY WILL
 BE SENT VIA EMAIL
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD
 BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN
 (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN
 ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE
 FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN
 AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500
 PERSONS.
  
 A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING
 AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL
 INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A
 THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION
 PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL
 INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING
 AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR
 THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE
 OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE
 SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT
 THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE
 WITH THE PERMITTED DOCUMENTS.
  
 B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B.
 CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD
 BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S
 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS
 REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS
 ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH
 INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND
 REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE
 PLACE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL
 INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER
 INFORMATION BEFORE THE PERMIT MAY BE ISSUED.
  
 C) THRESHOLD BLDG., REQUIRED STATEMENT W.P.B. AMENDMENT
 110.3.7.4.4, FS553.79(7)(D): ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT?S OR ENGINEER?S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE
 FIRESAFETY STANDARDS AS DETERMINED BY THE LOCAL
 AUTHORITY IN ACCORDANCE WITH THIS CHAPTER AND CHAPTER
 633.
  
 W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING
 WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE
 ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT
 THAT, TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S
 KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE
 APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE
 LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633
 FLORIDA STATUTE.
  
 D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME'
 OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE
 RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS
 SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE
 WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED,
 AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES
 WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST
 MEETING THE ABOVE CRITERIA.
  
 E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY
 FOR THIS TYPE OF CONSTRUCTION.
  
 F) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE
 REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE,
 PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING
 ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE
 APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR
 PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN
 COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR
 THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE
 IN BLACK & WHITE.
  
 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD
 BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS
 CONCERNING SPECIAL INSPECTORS.
  
 G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES,
 PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT
 AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING
 INSTALLATION SHALL BE SUPERVISED, INSPECTED AND
 CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING
 DOCUMENTS BY THE CONTRACTOR.
  

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2017-08-22 Time   Rev Time 0.00
Received By pgreilic Date 2017-08-18 Time 16:43 Sent To  
Notes
2017-08-22 12:01:51PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2017-06-21 Time   Rev Time 0.00
Received By pgreilic Date 2017-06-16 Time 08:33 Sent To  
Notes
2017-06-21 11:15:15PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]