|
 |
 |
 |
 |
 |
Plan Review Details - Permit 17060075
| Plan Review Stops For Permit 17060075 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-16 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-14 |
Time |
10:23 |
Sent To |
|
|
| Notes |
| 2017-06-15 10:24:17 | GJOHNSON'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-08 |
Time |
16:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-01 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2017-06-01 17:28:46 | GJOHNSON'S DESK |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-16 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-16 |
Time |
12:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-08 |
Time |
15:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-08 |
Time |
15:55 |
Sent To |
|
|
| Notes |
| 2017-06-08 16:00:06 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE SANITARY RISER DIAGRAM. PER WPB AMEND | | | TO FBC 107.3.5.1.3(13) AND FIELD INSPECTORS NOTES. | | | | | | 2. LAVATORY SHALL COMPLY WITH FBC PL 416.5 TEMPERED | | | WATER FOR PUBLIC HAND-WASHING FACILITIES. | | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | | 1070 OR CSA B125.3. | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |