Plan Review Details - Permit 17060007
Plan Review Stops For Permit 17060007
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-08-09 Cont ID  
Sent By cthroop Date 2017-08-09 Time 16:10 Rev Time 0.00
Received By cthroop Date 2017-08-09 Time 16:10 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-08-09 Cont ID  
Sent By cthroop Date 2017-08-09 Time 08:37 Rev Time 0.00
Received By cthroop Date 2017-08-09 Time 07:34 Sent To  
Notes
2017-08-09 08:42:00BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ITEM # 3 FROM 1ST REVIEW NOT ADDRESSED.
 2. PROVIDE ICC-ES REPORT FOR PROPOSED ICYNENE
 INSULATION. DESIGNER TO SELECT PRODUCT THAT COMPLIES
 WITH THE REQUIRED R VALUE (R-20).
 3. MANUFACTURERS INSTALLATION INSTRUCTIONS SHALL BE
 ON-SITE AT TIME OF INSPECTION.
  
 R402.1.1 INSULATION AND FENESTRATION CRITERIA.
 THE BUILDING THERMAL ENVELOPE SHALL MEET THE
 REQUIREMENTS OF TABLE R402.1.1 BASED ON THE CLIMATE
 ZONE SPECIFIED IN CHAPTER 3.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-28 Cont ID  
Sent By cthroop Date 2017-06-28 Time 11:31 Rev Time 0.00
Received By cthroop Date 2017-06-27 Time 16:28 Sent To  
Notes
2017-06-28 11:41:35BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED. ROOFING REVIEW APPROVED.
  
 2. PALM BEACH COUNTY IMPACT FEES WILL BE REQUIRED.
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.
  
 3. INSULATION - PROVIDE ICC-ES REPORT AND MANUFACTURERS
 INSTALLATION INSTRUCTIONS FOR THE PROPOSED R20 ICYNENE
 INSULATION. DESIGNER TO SELECT ICYNENE PRODUCT TO BE
 USED.
 R402.1.1 INSULATION AND FENESTRATION CRITERIA.
 THE BUILDING THERMAL ENVELOPE SHALL MEET THE
 REQUIREMENTS OF TABLE R402.1.1 BASED ON THE CLIMATE
 ZONE SPECIFIED IN CHAPTER 3.
  
 3. PROVIDE SITE DRAINAGE PLAN.
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10
 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE
 DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING
 FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 PERCENT AWAY
 FROM THE BUILDING.
  
 DEFINED FIELDS - INTERNAL USE ONLY
  
 USC-404 ? NEW: SFR, DETACHED
  
 CONSTRUCTION TYPE ? 5TH ED TYPE VB
 UNITS: - 1
 FLOORS: - 1
 BEDROOMS: - 3
 ROOMS: - 16
 SQ FT LIVABLE: - 3176
 SQ FT FOOTPRINT: - 4497
 SQ FT ROOF: - 3949
  
 SETBACKS FRONT ? 56? 1? (USE THIS TO ENTER VERTICAL
 DATUM IF KNOWN): NGVD29
 SETBACKS BACK ? 68? 5? (USE THIS TO ENTER FIRST FLOOR
 IF KNOWN): XX.XX
 SETBACKS LEFT ? 25? 8? (USE THIS TO ENTER SECOND FLOOR
 IF KNOWN: XX.XX
 OCC LOAD: - R3
 PROP USE: - SFR
 SPRINKLER SYS? - NO
 SPRK REQ'D? - NO
 BATHRMS: - 3
  
 BLDG CODE: - FL 2014
 OCC CLASS: - 5TH ED R3
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-08-02 Cont ID  
Sent By jpearson Date 2017-08-02 Time 08:41 Rev Time 0.00
Received By jpearson Date 2017-08-02 Time 08:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-06-19 Cont ID  
Sent By jpearson Date 2017-06-19 Time 08:31 Rev Time 0.00
Received By jpearson Date 2017-06-19 Time 08:31 Sent To  
Notes
2017-06-19 09:10:38CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW COMMENTS:
  
 1. RISER DIAGRAM DOES NOT SHOW SUFFICIENT DETAIL. WHICH
 PANEL WILL BE FED FROM THE TRANSFER SWITCH? THE DRAWING
 CURRENTLY SHOWS THE MDP FEEDING BOTH PANELS AND TYING
 INTO THE TRANSFER SWITCH, BUT I SEE NO LOAD ON THE
 TRANSFER SWITCH. PROVIDE CORRECTION/CLARIFICATION. IF
 THE TRANSFER SWITCH FEEDS BOTH PANELS, PROVIDE PROPER
 SIZE OF TRANSFER SWITCH TO HANDLE LOAD. FBC 107.2.1 ,
 107.3.5, NEC 215.5
 2. PROVIDE PANEL SCHEDULE/SIZING FOR PANEL MDP. NEC
 408.4, 408.30 FBC RE3706.1
 3. SHOW LOCATION ON PLAN FOR PANEL MDP AND TRANSFER
 SWITCH. FBC 107.2.1
 4. PROVIDE ACCURATE LOAD CALCULATION FOR ENTIRE
 SERVICE. THE LOAD CALCULATION ON PLAN IS NOT CLEARLY
 EXPLAINED. NEC 220, FBC 107.2.1
 5. PANEL SCHEDULE FOR PANEL A SHOWS CIRCUIT 9 AND 10 AS
 A 60 AMP CIRCUIT ON #12 WIRE. PROVIDE CORRECTION. NEC
 240.4(D) FBC RE3705.1
 6. PANEL SCHEDULE FOR PANEL A SHOWS CIRCUITS
 17,19,21,23,25,27,8,20,22,24, AND 26 AS A 20 AMP
 CIRCUIT ON #14 WIRE. PROVIDE CORRECTION. NEC 240.4(D)
 FBC RE3705.1
 7. A MINIMUM OF 75 PERCENT OF THE LAMPS IN PERMANENTLY
 INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY
 LAMPS OR A MINIMUM OF 75 PERCENT OF THE PERMANENTLY
 INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH
 EFFICACY LAMPS. PROVIDE NOTE TO SHOW COMPLIANCE. FBC EC
 R404.1
 8. PROVIDE SMOKE/CARBON MONOXIDE DETECTORS IN ALL
 LOCATION REQUIRED BY CODE. MANY ARE MISSING IN THE
 AREAS ADJACENT TO BEDROOMS. PROVIDE NOTE THAT ALL
 ALARMS WILL BE INTERCONNECTED. FBC R314, R315
 9. LIGHTING SHOWN IN CLOSETS FOR BEDROOM 2 AND 3 IS NOT
 TO CODE. LIGHTING WITH OPEN OR PARTIALLY ENCLOSED LAMPS
 AND PENDANT LUMINAIRES OR LAMPHOLDERS SHALL NOT BE
 PERMITTED IN CLOSETS. PROVIDE CORRECTION. NEC
 410.16(B), FBC RE4003.12
 10. PROVIDE GFCI OUTLET ON REAR OF HOUSE AS REQUIRED BY
 CODE. NEC 210.52(E)(1) FBC RE3901.7
 11. PROVIDE SWITCH CONTROLLED LIGHT AT EACH ENTRY/EXIT
 OF HOUSE. "AT LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING
 OUTLET SHALL BE INSTALLED IN HALLWAYS, STAIRWAYS,
 ATTACHED GARAGES, AND DETACHED GARAGES WITH ELECTRIC
 POWER. AT LEAST ONE WALL-SWITCH-CONTROLLED LIGHTING
 OUTLET SHALL BE INSTALLED TO PROVIDE ILLUMINATION ON
 THE EXTERIOR SIDE OF EACH OUTDOOR EGRESS DOOR HAVING
 GRADE LEVEL ACCESS, INCLUDING OUTDOOR EGRESS DOORS FOR
 ATTACHED GARAGES AND DETACHED GARAGES WITH ELECTRIC
 POWER. A VEHICLE DOOR IN A GARAGE SHALL NOT BE
 CONSIDERED AS AN OUTDOOR EGRESS DOOR. WHERE ONE OR MORE
 LIGHTING OUTLETS ARE INSTALLED FOR INTERIOR STAIRWAYS,
 THERE SHALL BE A WALL SWITCH AT EACH FLOOR LEVEL AND
 LANDING LEVEL THAT INCLUDES AN ENTRYWAY TO CONTROL THE
 LIGHTING OUTLETS WHERE THE STAIRWAY BETWEEN FLOOR
 LEVELS HAS SIX OR MORE RISERS". NEC 210.70(A)(2)(B) FBC
 RE3903.3
 12. PROVIDE INDICATION OF AFCI PROTECTION PER CODE.
 "ALL 120-VOLT, SINGLE PHASE, 15 AND 20 AMPERE BRANCH
 CIRCUITS SUPPLYING OUTLETS IN DWELLING UNIT FAMILY
 ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES,
 DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
 HALLWAYS, OR SIMILAR AREAS OR ROOMS, SHALL HAVE AFCI
 PROTECTION". NEC 210.12, FBC RE3902.12
 13. PROVIDE INDICATION OF TAMPER RESISTANT RECEPTACLES.
 A NOTE SHALL SUFFICE FOR THIS. NEC 406.12 FBC RE4002.14
 14. SHOW OUTLETS FOR CENTRAL VAC SYSTEM. FBC 107.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2017-08-10 Cont ID  
Sent By gjohnson Date 2017-08-10 Time 11:39 Rev Time 0.00
Received By gjohnson Date 2017-08-10 Time 11:39 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2017-06-15 Cont ID  
Sent By gjohnson Date 2017-06-15 Time 15:58 Rev Time 0.00
Received By gjohnson Date 2017-06-15 Time 15:58 Sent To  
Notes
2017-06-15 16:01:361ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
  
 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL
 CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER
 FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2.
  
 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL
 PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS
 STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB
 AMENDMENTS TO FBC SEC. 107.2.1.
  
 3. TYPE OF GAS, (LP OR NATURAL).
  
 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON
 THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8
 THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37).
  
 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY,
 (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING
 AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ?
 USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE
 SEC. 402.4.1.
  
 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE
 FBC-2014 FUEL GAS CODE SEC. 304.
  
 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014
 FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2
 PSI.
  
 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND
 TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE
 SEC. 502 THRU 505.
  
 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL
 GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA
 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-08-16 Cont ID  
Sent By cthroop Date 2017-08-16 Time 10:47 Rev Time 0.00
Received By cthroop Date 2017-08-15 Time 10:35 Sent To  
Notes
2017-08-16 10:36:08IMPACT FEES ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-08-10 Cont ID  
Sent By gjohnson Date 2017-08-10 Time 11:41 Rev Time 0.00
Received By gjohnson Date 2017-07-18 Time 08:27 Sent To  
Notes
2017-07-21 08:28:01R24 **TRAVELLING WITH 17060018**

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-06-28 Cont ID  
Sent By cthroop Date 2017-06-28 Time 11:29 Rev Time 0.00
Received By cthroop Date 2017-06-01 Time 12:11 Sent To  
Notes
2017-06-01 12:12:41R11 RUNNING WITH 17060015 & 17060018

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-08-16 Cont ID  
Sent By cthroop Date 2017-08-16 Time 10:47 Rev Time 0.00
Received By cthroop Date 2017-08-16 Time 10:47 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-06-28 Cont ID  
Sent By cthroop Date 2017-06-28 Time 11:30 Rev Time 0.00
Received By cthroop Date 2017-06-27 Time 16:27 Sent To  
Notes
2017-06-28 11:31:25BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT
 FEES, REQUIRED BY PALM BEACH COUNTY, SHALL BE PAID.
 UPON FINAL APPROVAL OF PLANS, ONE SET OF PLANS SHALL BE
 SIGNED OUT AND SUBMITTED TO PALM BEACH COUNTY FOR AN
 IMPACT FEE REVIEW. THE PLANS WITH THE IMPACT FEE STAMP
 AND A COPY OF THE PAID RECEIPT MUST BE RETURNED TO THE
 CITY BUILDING DEPARTMENT BEFORE THE BUILDING PERMIT CAN
 BE ISSUED. FOR INFORMATION CALL PALM BEACH COUNTY
 IMPACT FEES AT (561) 233-5025.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-08-08 Cont ID  
Sent By skennedy Date 2017-08-08 Time 13:47 Rev Time 0.00
Received By skennedy Date 2017-08-08 Time 13:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-06-27 Cont ID  
Sent By ccole Date 2017-06-27 Time 16:14 Rev Time 0.00
Received By ccole Date 2017-06-27 Time 16:13 Sent To  
Notes
2017-06-27 16:23:381ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL
 PERMIT #1706007
 6/27/17
  
 1) REFER TO SECTION M1503.4 FBC-14 RESIDENTIAL AND
 SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE NEW RANGE
 HOOD OVER THE ISLAND COOKTOP. PLEASE NOTE THAT MAKEUP
 AIR MAY BE REQUIRED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-08-10 Cont ID  
Sent By gjohnson Date 2017-08-10 Time 11:39 Rev Time 0.00
Received By gjohnson Date 2017-08-10 Time 11:39 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-06-15 Cont ID  
Sent By gjohnson Date 2017-06-15 Time 15:38 Rev Time 0.00
Received By gjohnson Date 2017-06-15 Time 15:38 Sent To  
Notes
2017-06-15 15:54:431ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS:
  
 1. THE WASHING MACHINE AND LAUNDRY TRAY SHALL NOT BE
 USED TO WET VENT THE TUB AND SHOWER. TUB AND SHOWER
 SHALL BE WET VENTED BY THE LAVATORY AS PART OF THE
 BATHROOM GROUP. PER FBC PL 912.1
  
 2. THE WASHING MACHINE BRANCH DRAIN SHALL CONNECT TO
 VERTICAL STACK TO BE VENTED PROPERLY. PER FBC PL
 901.2.1
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-06-28 Cont ID  
Sent By cthroop Date 2017-06-28 Time 11:29 Rev Time 0.00
Received By cthroop Date 2017-06-28 Time 08:10 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2017-08-08 Time   Rev Time 0.00
Received By pgreilic Date 2017-08-08 Time 16:37 Sent To  
Notes
2017-08-08 16:38:38 
  
 PAUL GREILICH, AICP, SENIOR PLANNER
 561-822-1443
 [email protected]
  

Review Stop Z ZONING
Rev No 1 Status F Date   Cont ID  
Sent By   Date 2017-06-21 Time   Rev Time 0.00
Received By pgreilic Date 2017-06-21 Time 14:39 Sent To  
Notes
2017-06-21 14:56:40DRIVEWAY DOES NOT MEET STANDARDS OUTLINED IN SEC.
 94-482
  
 PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]