Plan Review Details - Permit 17051270
| Plan Review Stops For Permit 17051270 |
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-06-09 |
Time |
03:56 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-06-09 |
Time |
03:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-06-05 |
Time |
05:15 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-05-31 |
Time |
09:55 |
Sent To |
P |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-06-09 |
Time |
03:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-06-09 |
Time |
03:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-05 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-06-05 |
Time |
05:15 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-06-05 |
Time |
04:41 |
Sent To |
|
|
| Notes |
| 2017-06-05 05:15:28 | 1) SUBMIT A FLOOR PLAN SHOWING THE EXISTING LOCATION OF | | | THE WATER CLOSET AND THE NEW LOCATION. SHOW THE FIXTURE | | | CLEARANCES PER FBC-PLUMBING SEC. 405.3.1. ADDITIONAL | | | PERMITS MAY BE REQUIRED.WPB AMEND. TO FBC SEC. 107.2.1. | | | 2) INDICATE ON THE PLANS THE TYPE OF PIPE MATERIAL | | | BEING INSTALLED. PVC MAY NOT BE PERMITTED DEPENDING ON | | | THE TYPE OF CONSTRUCTION (TYPE I, II,).2014 | | | FBC-BUILDING SEC.603, 603.1.2. NOTE THE TYPE OF | | | CONSTRUCTION ON THE PLANS. | | | 3) THE PLANS INDICATE THAT THE TOILET WILL BE INSTALLED | | | ABOVE THE FINISHED FLOOR. WILL THE TOILET BE LOCATED ON | | | A RAISED PLATFORM? THE PLANS ARE UNCLEAR AS TO THIS. | | | PROVIDE COMPLETE DETAILS ON THE WATER CLOSET | | | INSTALLATION.WPB AMEND. TO FBC SEC. 107.2.1. | | | 4) WILL THERE BE ANY PENETRATION OF FIRE RATED FLOORS | | | OR WALLS? IF SO, SUBMIT FIRESAFING DETAILS FOR ANY | | | RATED FLOOR OR WALL PENETRATIONS. WPB AMEND. TO FBC | | | SEC. 107.3.5.1. | | | 5) WHERE WILL THE NEW WATER CONNECTION FOR THE TOILET | | | CONNECT TO THE EXISTING SYSTEM AND HOW MANY FEET OF | | | PIPING WILL BE INSTALLED? A WATER RISER DIAGRAM MAY BE | | | REQUIRED.WPB AMEND. TO FBC SEC/ 107.3.5.1.3. | | | 6) INDICATE THE SIZE OF THE WATER CLOSET FIXTURE DRAIN. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | | | | | | | | | | |
|
|
|