Plan Review Details - Permit 17051249
| Plan Review Stops For Permit 17051249 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-07-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-07-18 |
Time |
19:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-07-18 |
Time |
19:14 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-06-09 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-06-09 |
Time |
06:54 |
Sent To |
|
|
| Notes |
| 2017-06-09 08:27:36 | PLAN | | | REVIEW COMMENTS | | | | | | 2ND REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE LWC-34 SYSTEM FOR THE LIGHTWEIGHT CONCRETE DECK | | | HAS A MAXIMUM DESIGN PRESSURE OF -60.0 PSF. THIS IS NOT | | | ADEQUATE FOR THE PERIMETER AND CORNER AREAS. SUBMIT | | | ENHANCED FASTENING CALCULATIONS THAT HAVE BEEN SIGNED | | | AND SEALED BY A FLORIDA LICENSED DESIGN PROFESSIONAL. | | | SEE LIMITATION NUMBER 5.7 ON PAGE 5 OF PRODUCT APPROVAL | | | FL2533. | | | | | | 2) SUBMIT TWO SETS OF A MOISTURE SURVEY OF THE | | | LIGHTWEIGHT CONCRETE DECK. FBC 1510 & FBC 1917 | | | | | | 3) SUBMIT TWO SETS OF A FASTENER WITHDRAWAL TESTING FOR | | | THE LIGHTWEIGHT CONCRETE DECK. SEE LIMITATION NUMBER | | | 5.9 ON PAGE 5. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-31 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-31 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2017-05-31 07:51:38 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) SPECIFY THE DECK TYPE, THE SYSTEM NUMBER AND THE | | | MAXIMUM DESIGN PRESSURE OF THE ROOFING SYSTEM THAT WILL | | | BE INSTALLED FROM THE ONES LISTED IN THE PRODUCT | | | APPROVAL. FBC 107.2.1 | | | | | | 2) IF THIS IS A MECHANICALLY ATTACHED SYSTEM AND | | | ENHANCED FASTENING IS REQUIRED IN ORDER TO MEET THE | | | INCREASED UPLIFT PRESSURES FOR ROOF ZONES 2 AND 3, THEN | | | SUBMIT TWO SETS OF SIGNED AND SEALED RAS117 | | | CALCULATIONS. FBC-R905.11.3 |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-07-18 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-07-18 |
Time |
19:25 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-07-17 |
Time |
14:30 |
Sent To |
|
|
| Notes |
| 2017-07-18 14:30:21 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-06-09 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-06-07 |
Time |
15:43 |
Sent To |
|
|
| Notes |
| 2017-06-08 15:43:26 | RESUB ROUTED TO RMCDOUGAL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-31 |
Time |
07:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-30 |
Time |
16:51 |
Sent To |
|
|
| Notes |
| 2017-05-30 16:51:41 | RMCDOUGAL |
|
|
|
Account Summary | Usage Policy | Privacy Policy