| 2017-08-17 18:23:55 | RESIDENTIAL (R3) RE-ROOF THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- THE PROPOSED ROOF WORK FOR THE FLAT ROOF IS TO | | | RECOVER THE DECK. GENERAL LIMITATION #5 OF RECOVER DECK | | | NOA 13-1022.13 SUBMITTED REQUIRES A FASTENER WITHDRAWAL | | | TEST TAS 105. TEST NEEDS TO BE PERFORMED. PROVIDE 2 | | | COPIES OF THE SIGNED AND SEALED TEST. NOTE: IF THE | | | TESTED FASTENER VALUE IS LESS THAN 275 LBF, THEN | | | INSULATION ATTACHMENT SHALL NOT BE ACCEPTABLE. SEE | | | GENERAL LIMITATION #5 ON LAST PAGE OF NOA. | | | | | | 2- ENGINEER TO REVISE THE RAS 117 CALCULATIONS | | | SUBMITTED: | | | THE FASTENER SPACING FOR THE FIELD AREA DOESN'T MATCH | | | THE FASTENER SPACING SHOWN ON THE NOA SUBMITTED. REVISE | | | AS REQUIRED BY SEC. 8.1 RAS 117. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-07 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-07 |
Time |
12:50 |
Sent To |
|
|
| Notes |
| 2017-08-07 13:10:17 | | | | 08/07/17 MET WITH CONTRACTOR. HE SAID THE FLAT ROOF IS | | | A ROOF OVER. I TOLD HIM HE NEEDS A PRODUCT APPROVAL FOR | | | ROOFOVER APPLICATION AND ENGINEERING NEEDS TO BE | | | REVISED TO MATCH NEW PRODUCT APPROVAL. TOLD HIM TO | | | REVIEW THE LIMITATIONS ON THE ROOF OVER PRODUCT | | | APPROVAL. TESTING MAY BE REQUIRED. JG. | | | | | | | | | | | | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- ENGINEER TO REVISE THE RAS 117 CALCULATIONS | | | SUBMITTED: | | | (A) SPECIFIC ROOFING ASSEMBLY TO BE INSTALLED IS NOT | | | CLEAR. THE SYSTEM TYPE SPECIFIED BY THE ENGINEER IS: "A | | | PAGE 6,7". THIS IS AN INSULATED SYSTEM. IT DOESN'T | | | MATCH THE SYSTEM TYPE HIGHLIGHTED BY THE ROOFING | | | CONTRACTOR. ROOFING CONTRACTOR HIGHLIGHTED A | | | NON-INSULATED SYSTEM TYPE E ON PAGE 14 AND 15 OF 16. | | | COORDINATE WITH ROOFING CONTRACTOR EXACT SYSTEM TO BE | | | INSTALLED AND REVISE AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | (B) SCOPE OF WORK IS NOT CLEAR. THIS IS NOT A "RECOVER" | | | ROOF PROJECT. THIS IS A RE-ROOF PROJECT. SEE PRODUCT | | | APPROVAL SUBMITTED AND REVISE AS REQUIRED. SEC. 107.2.1 | | | CITY AMENDMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-24 |
Time |
18:29 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-24 |
Time |
18:14 |
Sent To |
|
|
| Notes |
| 2017-05-24 18:31:49 | RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- ENGINEER TO REVISE THE RAS 117 CALCULATIONS | | | SUBMITTED: | | | (A) SPECIFIC ROOFING ASSEMBLY TO BE INSTALLED IS NOT | | | CLEAR. THE SYSTEM TYPE SPECIFIED BY THE ENGINEER IS: "A | | | PAGE 6,7". THIS IS AN INSULATED SYSTEM. IT DOESN'T | | | MATCH THE SYSTEM TYPE HIGHLIGHTED BY THE ROOFING | | | CONTRACTOR. ROOFING CONTRACTOR HIGHLIGHTED A | | | NON-INSULATED SYSTEM TYPE E ON PAGE 14 AND 15 OF 16. | | | COORDINATE WITH ROOFING CONTRACTOR EXACT SYSTEM TO BE | | | INSTALLED AND REVISE AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | (B) SCOPE OF WORK IS NOT CLEAR. THIS IS NOT A "RECOVER" | | | ROOF PROJECT. THIS IS A RE-ROOF PROJECT. SEE PRODUCT | | | APPROVAL SUBMITTED AND REVISE AS REQUIRED. SEC. 107.2.1 | | | CITY AMENDMENTS. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-08-25 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-25 |
Time |
18:25 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-24 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2017-08-25 14:25:32 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-08-18 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-18 |
Time |
09:44 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-16 |
Time |
13:51 |
Sent To |
|
|
| Notes |
| 2017-08-17 13:51:48 | RESUB ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-07 |
Time |
13:10 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-07 |
Time |
12:49 |
Sent To |
|
|
| Notes |
| 2017-08-07 12:50:05 | MET WITH CONTRACTOR. HE SAID THE FLAT ROOF IS A | | | ROOFOVER. TOLD HIM NEED PRODUCT APPROVAL FOR ROOF OVER | | | APPLICATION. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-24 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-24 |
Time |
13:43 |
Sent To |
|
|
| Notes |
| 2017-05-24 13:43:52 | JGOMEZ |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |