Plan Review Details - Permit 17051038
| Plan Review Stops For Permit 17051038 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-07-10 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-07-10 |
Time |
15:20 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-07-10 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-26 |
Time |
10:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-26 |
Time |
10:00 |
Sent To |
|
|
| Notes |
| 2017-05-26 10:08:58 | 1ST REVIEW FBC-2014 BUILDING | | | PERMIT #17051038 | | | 5/26/17 | | | | | | RESULTS: DENIED. | | | | | | 1) PLEASE CORRECT THE DESCRIPTION OF WORK ON THE PERMIT | | | APPLICATION SO THAT IT READS TILE INSTEAD OF SHINGLES. | | | | | | 2) SUBMIT A COMPLETE FL. PRODUCT APPROVAL FOR THE TILE | | | THAT INCLUDES THE COVER SHEET SHOWING THE 2014 | | | APPROVAL. | | | | | | 3) IN ACCORDANCE WITH SECTION 708.8 FBC-14 EXISTING | | | BUILDING CODE, ROOF TO WALL CONNECTIONS SHALL BE | | | IMPROVED AS REQUIRED BY SECTION 708.8.1. PLEASE PROVIDE | | | AN ENGINEERED DESIGN THAT INCLUDES UPLIFT CAPACITIES | | | AND ANCHORING AND STRAPPING DETAILS. AS AN ALTERNATIVE | | | TO AN ENGINEERED DESIGN, THE PRESCRIPTIVE RETROFIT | | | SOLUTIONS PROVIDED IN SECTIONS 708.8.1.1 THROUGH | | | 708.8.1.7 | | | | | | SHALL BE ACCEPTED AS MEETING THE MANDATED ROOF-TO-WALL | | | RETROFIT REQUIREMENTS. | | | | | | EXCEPTIONS: | | | | | | 1. WHERE IT CAN BE DEMONSTRATED (BY CODE ADOPTION DATE | | | DOCUMENTATION AND PERMIT ISSUANCE DATE) THAT | | | ROOF-TO-WALL CONNECTIONS AND/OR ROOF-TO FOUNDATION | | | CONTINUOUS LOAD PATH REQUIREMENTS WERE REQUIRED AT THE | | | TIME OF ORIGINAL CONSTRUCTION. | | | | | | 2. ROOF-TO-WALL CONNECTIONS SHALL NOT BE REQUIRED | | | UNLESS EVALUATION AND INSTALLATION OF CONNECTIONS AT | | | GABLE ENDS OR ALL CORNERS CAN BE COMPLETED FOR 15 | | | PERCENT OF THE COST OF ROOF REPLACEMENT. | | | | | | CHRISTOPHER L. COLE | | | STANDARD PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2017-05-25 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2017-05-25 |
Time |
14:41 |
Sent To |
B |
|
| Notes |
| 2017-05-25 14:42:44 | 5/25/2017 - PERMIT STATES SHINGLE; HOWEVER, THE PRODUCT | | | APPROVALS ARE FOR BARREL CLAY TILE AND ADHESIVE. BARREL | | | CLAY TILE MEETS DESIGN GUIDELINES FOR HISTORIC | | | DISTRICT. FLAT RE-ROOF IN-KIND. DLE | | 2017-05-23 14:27:08 | ROUTED TO DESIREE ESTABROOK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-05-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-05-23 |
Time |
13:48 |
Sent To |
|
|
| Notes |
| 2017-05-23 13:48:33 | ROUTED TO HISTORIC VIA ZONING INBOX |
|
|
|