Plan Review Details - Permit 17051032
| Plan Review Stops For Permit 17051032 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-14 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-14 |
Time |
07:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-06 |
Time |
13:17 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-06 |
Time |
13:13 |
Sent To |
E |
|
| Notes |
| 2017-06-06 13:18:04 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. ADDRESS FIRE COMMENTS AND RE-SUBMIT. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-07-13 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-07-13 |
Time |
07:24 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-07-13 |
Time |
07:23 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-06-06 |
Time |
15:36 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-06-06 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2017-06-06 15:38:25 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION | | | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | USING AN OVERHEAD VIEW OF THE ROOMS SHOW WHERE NEW OR | | | MOVED ELECTRIC IS LOCATED. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-07-12 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-07-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-07-12 |
Time |
12:19 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-25 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-24 |
Time |
14:22 |
Sent To |
B |
|
| Notes |
| 2017-05-25 07:40:38 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) THE SUBMITTED PLAN SHEETS DO NOT HAVE A TITLE BLOCK | | | THAT INCLUDES ADDRESS, CONTRACTOR AND/OR DESIGNER. | | | | | | PLEASE PROVIDE | | | | | | | | | | | | 2) THERE ARE NO DIRECTIONAL INDICATORS ON THE | | | HORIZONTAL DRAWING SHEETS; I.E KITCHEN VIEW/DINING ROOM | | | VIEW? | | | | | | PLEASE PROVIDE. | | | | | | | | | | | | 3) IS THE 32" DIMENSION INDICATOR AN OPENING OR IS IT | | | DOOR DIMENSION? | | | | | | PLEASE CLARIFY. | | | | | | | | | | | | 4) ARE THERE ANY FIRE ALARM DEVICES ON THE AFFECTED | | | WALL;EITHER SIDE? | | | | | | PLEASE CLARIFY. | | | | | | | | | | | | 5) THERE ARE NO INDICATIONS OF WHAT/WHERE ARE NEW | | | CABINETS. | | | | | | PLEASE PROVIDE. | | | | | | | | | | | | 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-14 |
Time |
07:26 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-10 |
Time |
11:39 |
Sent To |
|
|
| Notes |
| 2017-07-11 11:39:21 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-06-06 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-23 |
Time |
09:55 |
Sent To |
|
|
| Notes |
| 2017-05-24 09:56:06 | ROUTED TO FIRE INBOX |
|
|
|