Plan Review Details - Permit 17051021
Plan Review Stops For Permit 17051021
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-08 Cont ID  
Sent By rmcdouga Date 2017-06-08 Time 11:20 Rev Time 0.00
Received By rmcdouga Date 2017-06-08 Time 11:20 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-26 Cont ID  
Sent By rmcdouga Date 2017-05-26 Time 08:56 Rev Time 0.00
Received By rmcdouga Date 2017-05-26 Time 08:18 Sent To E
Notes
2017-05-26 09:32:18PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 FBC 107.2.1
  
 1) SUBMIT DOCUMENTS FROM THE PBC HEALTH DEPARTMENT AS
 REQUESTED BY THE PLUMBING COMMENTS. FAC 64E-9
  
 2) PROVIDE A LETTER FROM THE CONDO OWNERS ASSOCIATION
 EXPLAINING WHY THE TWO POOLS ARE TO BE REMOVED AND WHAT
 IS THE INTENDED USE OF THE AREA AFTER THE POOLS ARE
 FILLED.
  
 3) PROVIDE A FULL DETAILED SCOPE OF WORK AND SPECIFY IF
 THE EXISTING POOL CABANA IS TO REMAIN OR WILL BE
 DEMOLISHED ON THE PLANS.
  
 4) THE POOL COPING, CONCRETE GUNITE, REINFORCING STEEL,
 TILES, COPING AND DECKING MATERIALS ARE REQUIRED TO BE
 REMOVED FROM THE SITE AND DISPOSED OF PROPERLY, THEY
 CAN NOT BE USED TO FILL THE POOL.
  
 5) REMOVE A TWO FOOT SQUARE SECTION OF CONCRETE GUNITE
 AT THE BOTTOM OF THE POOL AT THE LOWEST POINT IN THE
 DEEP END AND ANOTHER TWO FOOT SQUARE HOLE IN THE
 SHALLOW END.
  
 6) REMOVE ALL ELECTRICAL CONDUCTORS SERVING THE
 ABANDONED POOL FROM THE ELECTRICAL PANEL AND REMOVE OR
 CAP THE VACATED CONDUITS. (ELECTRICAL PERMIT REQUIRED)
  
 7) REMOVE AND CAP ANY GAS LINES SERVICING THE POOL
 HEATER OR SIMILAR ABANDONED GAS FIRED EQUIPMENT. (GAS
 PERMIT REQUIRED)
  
 8) REMOVE ALL ACCESSORIES, INCLUDING LADDERS, SLIDES
 AND DIVING BOARDS.
  
 9) AFTER INITIAL INSPECTION, FILL THE POOL WITH GRAVEL,
 OR SAND. DEMOLITION MATERIALS OR ROCKS OVER 3/4 INCHES
 IN DIAMETER MAY NOT BE USED FOR BACKFILL.
  
 10) BACKFILL SHOULD BE PERFORMED IN LIFTS NOT TO EXCEED
 EIGHT (8) INCH LAYERS AND COMPACTED TO 90%.
  
 11) INSPECTIONS
 A MINIMUM OF TWO INSPECTIONS ARE REQUIRED AS FOLLOWS:
 1. IN PROGRESS DEMOLITION INSPECTION TO BE PERFORMED
 AFTER THE DEMOLITION AND REMOVAL OF ELECTRICAL AND GAS
 LINES BUT PRIOR TO BACK FILL.
 2. FINAL TO BE PERFORMED AFTER THE POOL IS BACKFILLED
 AND PROPERLY GRADED.
  
 IMPORTANT NOTE
 ALLOWING THE POOL SHELL TO REMAIN MAY RESULT IN
 DIFFERENTIAL SETTLEMENT AND THEREFORE THE POOL AREA MAY
 NOT BE USED FOR THE CONSTRUCTION OF FUTURE STRUCTURES.
 TO INSURE THAT THE SOIL IS SUITABLE FOR FUTURE
 CONSTRUCTION, A REPORT FROM A GEOTECHNICAL ENGINEER
 MUST BE PROVIDED AT THE TIME OF PERMIT SUBMITTAL. THAT
 REPORT SHALL IDENTIFY ANY SPECIFIC REMOVAL AND
 COMPACTION REQUIREMENTS AND SHALL BE NOTED ON THE
 SUBMITTED PLANS.
  
 12) SUBMIT A COPY OF THE SIGNED CONTRACT WITH THE CONDO
 ASSOCIATION TO VERY THE VALUE OF THE WORK. FBC 109.3
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-05-26 Cont ID  
Sent By jleahy Date 2017-05-26 Time 10:52 Rev Time 0.00
Received By jleahy Date 2017-05-26 Time   Sent To Z
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-06-08 Cont ID  
Sent By rmcdouga Date 2017-06-08 Time 11:21 Rev Time 0.00
Received By rmcdouga Date 2017-06-05 Time 11:00 Sent To  
Notes
2017-06-06 11:00:14RESUB ROUTED TO TKLARGE

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-30 Cont ID  
Sent By jroach Date 2017-05-30 Time 13:58 Rev Time 0.00
Received By jroach Date 2017-05-23 Time 16:15 Sent To  
Notes
2017-05-24 16:15:52ROUTED TO POOL INBOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-06-07 Cont ID  
Sent By tklarge Date 2017-06-07 Time 11:58 Rev Time 0.00
Received By tklarge Date 2017-06-07 Time 11:58 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-05-25 Cont ID  
Sent By tklarge Date 2017-05-25 Time 11:01 Rev Time 0.00
Received By tklarge Date 2017-05-25 Time 10:56 Sent To  
Notes
2017-05-25 11:00:571) INDICATE ON BOTH SETS OF PLANS IF THE POOL PIPING
 AND THE POOL EQUIPMENT IS BEING REMOVED OR NOT.
 2) SUBMIT A COPY OF ANY DOCUMENTATION REQUIRED TO BE
 SUBMITTED TO THE PALM BEACH COUNTY HEALTH DEPT. FOR THE
 DEMOLITION OF THESE POOLS. WPB AMEND. TO FBC SEC.
 107.2.1.
  
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2017-05-30 Cont ID  
Sent By jroach Date 2017-05-30 Time 13:56 Rev Time 0.00
Received By jroach Date 2017-05-30 Time 13:56 Sent To  
Notes
2017-05-30 13:57:23LOCATION OF POOL AND DECK REMOVAL SHALL BE SODDED AND
 IRRIGATED.
  
 QUESTIONS/COMMENTS, CONTACT JOHN ROACH, PRINCIPAL
 PLANNER, AT 561.822.1448 OR [email protected].
2017-05-26 15:30:21ROUTED TO JOHN ROACH