Plan Review Details - Permit 17051004
Plan Review Stops For Permit 17051004
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-21 Cont ID  
Sent By jwitmer Date 2017-06-21 Time 15:10 Rev Time 0.00
Received By jwitmer Date 2017-06-21 Time 14:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-06-02 Cont ID  
Sent By jwitmer Date 2017-06-02 Time 16:54 Rev Time 0.00
Received By jwitmer Date 2017-06-01 Time 11:19 Sent To  
Notes
2017-06-02 16:54:242014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17051004
 ADD: 777 S FLAGLER DR. 14 TH FLOOR CORRIDOR
 CONT: BUTLER CONSTRUCTION CO.
 TEL: 561-832-9700
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: FRI. JUNE 02/ 2017
 ACTION: DENIED
  
 1) PLEASE SEE THE PERMIT APPLICATION INDICATES UNDER
 THE SCOPE OF WORK PARTIAL HALLWAY RENOVATION. SHEET
 002_ALS1.1 THE LIFE SAFETY PLAN CLASSIFIES THIS AS A
 LEVEL 1 ALTERATION. SEE 2014 FBC-EXISTING BUILDING CODE
 SECTION 503.1. LEVEL 1 ALTERATIONS INCLUDE THE REMOVAL
 AND REPLACEMENT OR THE COVERING OF EXISTING MATERIALS,
 ELEMENTS, EQUIPMENT, OR FIXTURES USING NEW MATERIALS,
 ELEMENTS, EQUIPMENT, OR FIXTURES THAT SERVE THE SAME
 PURPOSE.
 THE LIFE SAFETY PLAN SHOWS NEW TENANT SEPARATION WALLS,
 NOTE 9, NOTE 1 ALIGN NEW WALLS, WALL LEGEND SHOWS NEW 1
 HOUR RATED TENANT DISMISSING WALL AS WELL AS CORRIDOR
 WALLS AND NOTE # 2 INDICATES NEW DOORS.
 THIS IS A LEVEL II ALTERATION PLEASE CORRECT PLANS.
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
 2) THE NEWLY FORMED TENANT SPACE ON THE LEFT SIDE OF
 THE PLANS PLEASE PROVIDE THE SQ. FEET OF THIS UNIT.
 PLEASE ALSO PROVIDE THE OVERALL DIAGONAL DISTANCE FOR
 THIS SPACE. DEPENDING ON THE SQ. FOOTAGE OF THE SPACE
 AND OCCUPANT LOAD 2 MEANS OF EGRESS MAYBE REQUIRED.
 THERE DISTANCE APART MAYBE REQUIRED TO BE 1/3RD THE
 OVER ALL DIAGONAL DISTANCE APART.
 2014 FBC-B TABLE 1015.1.
 2014 FBC-B 1015.2.1.
  
 3) THE 002_ ALS1.1 SHEET AND A1.1.1 SHOW A NEW DOOR
 C1402 WITH SIDE LIGHTS, BUT 007_A2.0.1 DOOR C1402 IS
 DOOR TYPE A, NO SIDELIGHTS ARE SHOWN. DISCREPANCY IN
 PLANS. 107.2.1.3. PLEASE PROVIDE ADDITIONAL
 INFORMATION. SHEET 008_A3.0.1. SHOW A DOOR # 1 WITH
 DOUBLE DOORS AND SIDELIGHTS.
  
 4) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-06-07 Cont ID  
Sent By jleahy Date 2017-06-07 Time 09:33 Rev Time 0.00
Received By jleahy Date 2017-06-07 Time 09:33 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-06-26 Cont ID  
Sent By scaldero Date 2017-06-26 Time 09:26 Rev Time 0.00
Received By scaldero Date 2017-06-26 Time 09:26 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2017-06-05 Cont ID  
Sent By scaldero Date 2017-06-05 Time 08:16 Rev Time 0.00
Received By scaldero Date 2017-06-05 Time 08:16 Sent To  
Notes
2017-06-05 08:17:13PERMIT # 17051004
 REVIEW COMMENTS - FIRE DEPARTMENT
  
 1) PLEASE REVIEW AND RESPOND TO BUILDING PLAN REVIEWER
 COMMENTS.
  
 SUE ELLEN CALDERON
 ASSISTANT FIRE MARSHAL
 FIRE INVESTIGATOR & INSPECTOR
 OFFICE OF THE FIRE MARSHAL
 WEST PALM BEACH FIRE RESCUE
 [email protected]
 (561) 804-4751
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-17 Cont ID  
Sent By lmarchan Date 2017-07-17 Time 09:36 Rev Time 0.00
Received By lmarchan Date 2017-06-14 Time 14:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-06-07 Cont ID  
Sent By jleahy Date 2017-06-07 Time 09:34 Rev Time 0.00
Received By jleahy Date 2017-05-23 Time 11:40 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-06-02 Cont ID  
Sent By jwitmer Date 2017-06-02 Time 16:54 Rev Time 0.00
Received By jwitmer Date 2017-06-02 Time 15:48 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2017-06-01 Cont ID  
Sent By ccole Date 2017-06-01 Time 15:08 Rev Time 0.00
Received By ccole Date 2017-06-01 Time 14:48 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2017-07-17 Cont ID  
Sent By lmarchan Date 2017-07-17 Time 09:36 Rev Time 0.00
Received By lmarchan Date 2017-07-17 Time 09:36 Sent To  
Notes
2017-06-21 15:04:48ARCHITECTURAL & M-E-P SHEETS ALL VERIFIED FOR
 ELECTRONIC SIGNATURES. J. W. 06/21/2017


Account Summary | Usage Policy | Privacy Policy