| Plan Review Stops For Permit 17050942 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-30 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-30 |
Time |
17:10 |
Sent To |
Z |
|
| Notes |
| 2017-06-30 17:13:46 | ONLY ONE SET OF SUPPLEMENTAL DOCUMENTS WAS SUBMITTED. | | | APPLICANT IS TO OBTAIN A SET FROM RECORDS AFTER | | | ISSUANCE. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-09 |
Time |
07:32 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-09 |
Time |
07:15 |
Sent To |
|
|
| Notes |
| 2017-06-09 07:32:32 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | FROM PREVIOUS LIST: | | | | | | 1. FROM REVIEW #1: FBC B 1603.1.4, REVISE PLAN TO | | | INCLUDE WIND DESIGN DATA INCLUDING DESIGN PRESSURE | | | REQUIREMENT FOR THE PROPOSED DOCK DOORS. | | | | | | REVIEW #2: RESPONSE LETTER STATES THAT SUPPORTING | | | DOCUMENTS INCLUDE A PAGE WITH WIND DESIGN CRITERIA. IT | | | IS NOT CLEAR WHERE THIS CAN BE LOCATED. NOTE THAT IT IS | | | THE DESIGNER'S RESPONSIBILITY TO SPECIFY WIND DESIGN | | | CRITERIA, DOOR PRODUCT APPROVAL IS TO SHOW COMPLIANCE | | | WITH THE DESIGN PRESSURES. THE SIGNED AND SEALED PLANS | | | DO NOT APPEAR TO BE REVISED TO INCLUDE THIS | | | INFORMATION. | | | | | | REVISE PLAN TO INCLUDE WIND DESIGN DATA INCLUDING | | | DESIGN PRESSURE REQUIREMENT FOR THE PROPOSED DOCK | | | DOORS. | | | | | | 2. FROM REVIEW #1: FBC 107, THIS PERMIT WILL BE ISSUED | | | WITH PROVISO, DOCK DOOR PRODUCT APPROVALS TO BE | | | SUBMITTED AND REVIEWED PRIOR TO INSTALLATION. | | | | | | IF APPLICANT KNOWS WHICH DOOR IS PROPOSED, PLEASE | | | PROVIDE AT THIS TIME. | | | | | | REVIEW #2: DOOR SPECS WERE PROVIDED, BUT THE PRODUCT | | | APPROVAL (FLORIDA STATE PRODUCT APPROVAL, MIAMIDADE | | | NOA, OR SITE SPECIFIC ORIGINAL SIGNED AND SEALED | | | ENGINEERING) WAS NOT PROVIDED. THERE IS A LETTER IN THE | | | SUBMITTAL REGARDING A 2007 FLORIDA STATE PRODUCT | | | APPROVAL; THAT WAS GOVERNING CODE TWO CYCLES AGO. | | | | | | FBC B 1609, PROVIDE DOOR PRODUCT APPROVAL. IF A FLORIDA | | | STATE PRODUCT APPROVAL OR MIAMI DADE NOA IS NOT | | | AVAILABLE, ORIGINAL SIGNED AND SEALED ENGINEERING | | | DOCUMENTS ARE REQUIRED. | | | | | | NEW COMMENTF: | | | | | | 3. FLORIDA STATUTE 481 AND FAC61G16 REQUIRE THAT THE | | | ARCHITECT'S TITLE BLOCK INCLUDE THE ARCHITECT BUSINESS | | | LICENSE NUMBER. FOR ALL SHEETS WHICH CHANGE, REVISE | | | TITLE BLOCK TO BE IN COMPLIANCE. THIS IS NOT NECESSARY | | | FOR SHEETS WHICH DO NOT CHANGE FOR THIS SUBMITTAL; | | | PLEASE ENSURE COMPLIANCE FOR FUTURE SUBMITTALS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-30 |
Time |
07:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-30 |
Time |
07:08 |
Sent To |
|
|
| Notes |
| 2017-05-30 07:20:43 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. FBC B 1603.1.4, REVISE PLAN TO INCLUDE WIND DESIGN | | | DATA INCLUDING DESIGN PRESSURE REQUIREMENT FOR THE | | | PROPOSED DOCK DOORS. | | | | | | 2. FBC 107, THIS PERMIT WILL BE ISSUED WITH PROVISO, | | | DOCK DOOR PRODUCT APPROVALS TO BE SUBMITTED AND | | | REVIEWED PRIOR TO INSTALLATION. | | | | | | IF APPLICANT KNOWS WHICH DOOR IS PROPOSED, PLEASE | | | PROVIDE AT THIS TIME. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-30 |
Time |
09:39 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-30 |
Time |
09:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-09 |
Time |
08:14 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-09 |
Time |
08:14 |
Sent To |
|
|
| Notes |
| 2017-06-09 08:15:50 | APPROVED WITH EXCEPTION: | | | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | | | | 1. ELECTRICAL SHEET IS NOT SIGNED AND SEALED AS | | | REQUIRED BY FS471, FAC61G15-23. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-06-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-01 |
Time |
11:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-01 |
Time |
11:05 |
Sent To |
|
|
| Notes |
| 2017-06-01 11:06:33 | APPROVED W/EXCEPTION, NEED ELECTRICAL PERMIT | | | APPLICATION. FBC 105.1 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-30 |
Time |
12:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-06-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-19 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-06-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-05 |
Time |
09:36 |
Sent To |
|
|
| Notes |
| 2017-06-05 09:50:54 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET A 501 - THE DRAWING INDICATES THAT WHEN THE | | | PROPOSED GARAGE DOOR IS OPEN, IT MAY POSE AS AN | | | OBSTRUCTION TO THE EXISTING FIRE SPRINKLER HEAD | | | LOCATIONS. | | | | | | PLEASE REVIEW AND PROVIDE A REVIEW FROM A FIRE | | | SPRINKLER CONTRACTOR THAT NO OBSTRUCTION WILL OCCUR OR | | | PROVIDE A NOTE INDICATING THAT THE FIRE SPRINKLER HEAD | | | LOCATION WILL BE MODIFIED TO PROVIDE CODE COVERAGE. | | | | | | | | | | | | | | | 2) SHEET E 1 - THOUGH IT MAY BE EXISTING, THERE ARE NO | | | INDICATIONS THAT THE EXIT SIGNS AND EMERGENCY LIGHTS | | | ARE EXISTING AND/OR THAT THEY WILL BE INSTALLED WITH | | | THE PROPOSED PROJECT. | | | | | | PROVIDE DRAWING INDICATIONS OR AN APPLICABLE NOTE THAT | | | THEY ARE EXISTING. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-27 |
Time |
14:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-06-20 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-08 |
Time |
15:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-07 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-06-07 |
Time |
16:05 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-05-23 |
Time |
11:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
N |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-05 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-05 |
Time |
13:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-09 |
Time |
07:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-09 |
Time |
07:37 |
Sent To |
|
|
| Notes |
| 2017-06-09 08:10:23 | ELECTRICAL PLAN HAS NO DIGITAL SIGNATURE. JP 06-09-17 | | 2017-06-09 07:41:01 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. ELECTRICAL SHEET IS NOT SIGNED AND SEALED AS | | | REQUIRED BY FS471, FAC61G15-23. | | | | | | THE ENGINEER'S TITLE BLOCK IS NOT IN COMPLIANCE WITH | | | FS471, FAC61G15-23.002 (CERTIFICATE OF AUTHORIZATION | | | FOR T.E., INC. LACKING). | | | | | | IF ENGINEER DOES NOT HAVE A DIGITAL OR ELECTRONIC | | | SIGNATURE & SEAL, YOU MAY PROVIDE AN ORIGINAL SIGNED | | | AND SEALED PAPER DOCUMENT. | | | | | | 2. THE DBPR WEBSITE (MYFLORIDALICENSE.COM) DOES NOT | | | REFLECT THAT ELECTRICAL ENGINEER HAS COMPLETED THE | | | ADVANCED FLORIDA BUILDING CODE COURSE REQUIRED BY | | | FS471.0195. PLEASE SEND EVIDENCE THAT THE COURSE WAS | | | COMPLETED (DUE BY JUNE 30, 2016) TO FBPE AND REQUEST | | | THAT YOUR RECORD BE UPDATED. | | | | | | 3. SEE BUILDING COMMENT REGARDING ARCHITECT'S TITLE | | | BLOCK. REVISE ALL RESUBMITTED SHEETS, FAC61G1-16.004. | | | | | | ARCHITECT'S SIGNATURE AND SEAL ARE OK; NEW SHEETS | | | SUBMITTED FOR REVIEW CYCLE #3 NEED TO BE VERIFIED. | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-07-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-07-05 |
Time |
|
Sent To |
I |
|
| Notes |
| 2017-07-05 09:36:53 | ROUTED TO LINDA LOUIE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-06-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-06-16 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-02 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-06-02 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2017-06-02 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-06-02 10:12:49 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) NEED UPDATED SURVEY OF THE PROPERTY. | | | | | | 2.) THERE ARE INCONSISTENCIES WITH THE NORTH ARROW AND | | | THE LOCATION MAPS ON SHEET TS101. PLEASE ADDRESS. | | | | | | 3.) WHY IS THE "FUTURE DRY DEPOT ADDITION" SHOW IN THE | | | SITE PLAN WHEN IT IS NOT A PART OF THE SCOPE OF WORK? | | | PLEASE CLARIFY/ADDRESS. | | | | | | 4.) AN AMENDMENT TO THE COSTCO COMMERCIAL PLANNED | | | DEVELOPMENT (CPD) IS REQUIRED PRIOR TO THE APPROVAL OF | | | THE BUILDING PERMIT BY THE ZONING DIVISION. | | | | | | | | | NOTES: | | | | | | * ZONE: CPD | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|