Plan Review Details - Permit 17050817
Plan Review Stops For Permit 17050817
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-06-05 Cont ID  
Sent By jgomez Date 2017-06-05 Time 18:16 Rev Time 0.00
Received By jgomez Date 2017-06-05 Time 17:32 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-05-24 Cont ID  
Sent By jgomez Date 2017-05-24 Time 17:35 Rev Time 0.00
Received By jgomez Date 2017-05-24 Time 17:29 Sent To  
Notes
2017-05-24 18:10:31RESIDENTIAL (R3) RE-ROOF SECOND BUILDING REVIEW
 CHECKLIST.
 CODE: FBC 5TH EDITION (2014).
  
 1- ORIGINAL COMMENT:
 NEED SIGNED AND SEALED RAS 117 CALCULATIONS (2 COPIES)
 AS REQUIRED BY GENERAL LIMITATION #7 ON LAST PAGE OF
 NOA 13-1022.15 SUBMITTED. NOTE: HOUSE IS LOCATED IN
 EXPOSURE "D". TAKE THIS INTO CONSIDERATION WHEN DOING
 THE CALCULATIONS. CALCULATIONS ARE REQUIRED TO MEET THE
 DESIGN PRESSURES OF SEC. R301.1 FBC RESIDENTIAL.
  
 RESPONSE:
 ENGINEER TO REVISE THE RAS 117 CALCULATIONS SUBMITTED:
 (A) ACCORDING TO SEC. R301.2.1.4 FBC-RESIDENTIAL, THIS
 BUILDING IS LOCATED IN EXPOSURE "D" NOT EXPOSURE "C".
 REVISE THE EXPOSURE AND THE DESIGN PRESSURES
 ACCORDINGLY.
 NOTE: THIS WAS NOTED ON MY ORIGINAL COMMENT TO HELP
 EXPEDITE THE REVIEW PROCESS.
  
 (B) SCOPE OF WORK IS NOT CLEAR. THIS IS NOT A "RECOVER"
 ROOF PROJECT. THIS IS A RE-ROOF PROJECT. SEE PRODUCT
 APPROVAL SUBMITTED AND REVISE AS REQUIRED. SEC. 107.2.1
 CITY AMENDMENTS.
  
 (C) SPECIFIC ROOFING ASSEMBLY TO BE INSTALLED IS NOT
 CLEAR. THE SYSTEM TYPE SPECIFIED BY THE ENGINEER IS: "A
 PAGE 6,7". THIS IS AN INSULATED SYSTEM. IT DOESN'T
 MATCH THE SYSTEM TYPE HIGHLIGHTED BY THE ROOFING
 CONTRACTOR. ROOFING CONTRACTOR HIGHLIGHTED A
 NON-INSULATED SYSTEM TYPE E ON PAGE 14 AND 15 OF 16.
 COORDINATE WITH ROOFING CONTRACTOR EXACT SYSTEM TO BE
 INSTALLED AND REVISE AS REQUIRED. SEC. 107.2.1 CITY
 AMENDMENTS.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-22 Cont ID  
Sent By jgomez Date 2017-05-22 Time 08:41 Rev Time 0.00
Received By jgomez Date 2017-05-22 Time 07:43 Sent To  
Notes
2017-05-22 08:50:12RESIDENTIAL (R3) RE-ROOF BUILDING REVIEW COMMENTS.
 CODE: FBC 5TH EDITION (2014).
  
 1- NEED SIGNED AND SEALED RAS 117 CALCULATIONS (2
 COPIES) AS REQUIRED BY GENERAL LIMITATION #7 ON LAST
 PAGE OF NOA 13-1022.15 SUBMITTED. NOTE: HOUSE IS
 LOCATED IN EXPOSURE "D". TAKE THIS INTO CONSIDERATION
 WHEN DOING THE CALCULATIONS. CALCULATIONS ARE REQUIRED
 TO MEET THE DESIGN PRESSURES OF SEC. R301.1 FBC
 RESIDENTIAL.
  
 IF YOU HAVE ANY QUESTIONS PLEASE CONTACT
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-05-19 Cont ID  
Sent By jgomez Date 2017-05-22 Time 08:50 Rev Time 0.00
Received By destabro Date 2017-05-19 Time 13:59 Sent To B
Notes
2017-05-19 14:02:335/19/2017 - FLAT RE-ROOF, LOCATED TO THE REAR. DLE
2017-05-18 17:06:58ROUTED TO DESIREE ESTABROOK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-06-05 Cont ID  
Sent By jgomez Date 2017-06-05 Time 18:15 Rev Time 0.00
Received By jgomez Date 2017-06-02 Time 12:08 Sent To B
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-05-24 Cont ID  
Sent By jgomez Date 2017-05-24 Time 18:11 Rev Time 0.00
Received By jgomez Date 2017-05-24 Time 13:43 Sent To  
Notes
2017-05-24 13:43:26RESUB ROUTED TO JGOMEZ

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-22 Cont ID  
Sent By jgomez Date 2017-05-22 Time 08:50 Rev Time 0.00
Received By jgomez Date 2017-05-17 Time 17:22 Sent To HIST
Notes
***NONE***