Plan Review Details - Permit 17050772
| Plan Review Stops For Permit 17050772 |
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-20 |
Time |
17:02 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-05-19 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-19 |
Time |
14:51 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-07-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-19 |
Time |
11:22 |
Sent To |
|
|
| Notes |
| 2017-06-20 11:23:00 | RESUB ROUTED TO FIRE INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-05-17 |
Time |
16:27 |
Sent To |
|
|
| Notes |
| 2017-05-18 16:27:40 | ROUTED TO FIRE INBOX |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-07-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-06 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-05 |
Time |
17:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-06 |
Time |
15:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-06 |
Time |
15:44 |
Sent To |
|
|
| Notes |
| 2017-06-06 16:40:16 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17050772 | | | 6/6/17 | | | | | | RESULTS: DENIED. | | | | | | 1) THE SUBMITTED MECHANICAL PLANS FROM THE MAIN SET DO | | | NOT SPECIFICALLY PROVIDE INFORMATION FOR THE PROPOSED | | | KITCHEN EXHAUST HOOD AND SYSTEM. SUBMIT PLANS THAT SHOW | | | THE LOCATIONS OF THE OVEN, THE EXHAUST HOOD, THE | | | EXHAUST DUCT RUN FROM OUTLET TO TERMINATION, AND THE | | | EXHAUST FAN, | | | | | | 2) PROVIDE EQUIPMENT SCHEDULES FOR THE HOOD AND FAN. | | | PLEASE NOTE THE FAN SCHEDULE ON M001 IS DESIGNATED " | | | FOR REFERENCE ONLY". | | | | | | 3) INDICATE HOW MAKEUP IS BEING PROVIDED FOR THE | | | EXHAUST SYSTEM AND PROVIDE VENTILATION AND AIR BALANCE | | | CALCULATIONS, | | | | | | 4) PROVIDE CLEARANCE DISTANCE MEASUREMENTS FROM THE | | | EXHAUST OUTLET TO MECHANICAL AND GRAVITY AIR INTAKES, | | | | | | 5) THERE ARE PRODUCT DATA SUBMITTALS FOR AN INLINE | | | EXHAUST FAN AND A SIDEWALL EXHAUST FAN- WHICH IS TO BE | | | USED? THE EQUIPMENT SCHEDULE ON M001 INDICATES THE | | | INLINE FAN. IF THAT IS THE CASE, PLEASE CLARIFY THE | | | PURPOSE OF THE SIDEWALL FAN. | | | | | | 6) A FL. LICENSED MECHANICAL CONTRACTOR MUST SUBMIT A | | | PERMIT APPLICATION TO INSTALL THE EXHAUST HOOD AND | | | DUCTWORK- SECTION 489.113(3) FLORIDA STAUTES. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|