 |
Plan Review Details - Permit 17050594
| Plan Review Stops For Permit 17050594 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-23 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-23 |
Time |
10:45 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-02 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-02 |
Time |
14:37 |
Sent To |
|
|
| Notes |
| 2017-08-02 16:25:23 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. WORK DESCRIPTION INCLUDES NEW FLOORING. | | | 2. IDENTIFY AREAS OF NEW FLOORING ON PLAN. | | | 3. PROVIDE DEMENSIONS OR TOTAL SQUARE FOOTAGE OF | | | PROPOSED FLOORING. | | | 4. VALUE OF $25,000 APPEARS LOW FOR THE PROPOSED SCOPE | | | OF WORK. | | | | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 - VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-07-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-11 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-10 |
Time |
13:37 |
Sent To |
|
|
| Notes |
| 2017-07-11 11:17:29 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. 2ND REQUEST. CANNOT VERIFY VALUE. | | | | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | CITY OF WPB CHPT. 1 - VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-06 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-06 |
Time |
14:57 |
Sent To |
|
|
| Notes |
| 2017-06-06 15:39:13 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. CANNOT VERIFY VALUE AT THIS TIME. ADDITIONAL | | | INFORMATION REQUIRED. | | | 2. DESIGN PROFESSIONAL MAY BE REQUIRED TO SIGN AND SEAL | | | PLANS. | | | 3. PROVIDE THE FOLLOWING ASTM'S FOR THE FLOORING | | | UNDERLAYMENT - E-84 (FLAME SPREAD), E-90 (AIRBOURNE | | | SOUND) & E-492 (IMPACT SOUND). | | | 4. PROVIDE ENRERGY SUBMITTAL FOR INSULATION REPLACED IN | | | EXTERIOR WALLS. | | | 5. IDENTIFY RATED WALLS ON PLAN. | | | | | | THE PERMIT VALUATION AND PERMIT FEE MUST BE | | | COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED | | | CONTRACTOR WOULD PROVIDE. | | | YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE | | | OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT | | | RENTAL TO VERIFY VALUE. | | | | | | | | | CITY OF WPB CHPT. 1 - VALUE | | | 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF | | | THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF | | | BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS, | | | MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE | | | UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE | | | DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED, | | | QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS | | | (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE | | | BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION | | | OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT | | | VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING, | | | MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK, | | | ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS, | | | OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE. | | | VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED | | | DATA OF NATIONAL CONSTRUCTION | | | COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.), | | | AS PUBLISHED BY INTERNATIONAL CODE CONGRESS. | | | FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE | | | BUILDING OFFICIAL. | | | | | | PURSUANT TO FBC 107.1, AND FS 481.229 (1) (C), AS THIS | | | DESIGN MAY EXCEED $25,000.00 IN VALUE, THE DESIGN MUST | | | BE PREPARED BY A LICENSED PROFESSIONAL PURSUANT TO FS | | | 481. | | | | | | FBC 603.1 FLAME SPREAD ? ASTM E-84 | | | | | | FBC 1207.2 AIR-BORNE SOUND. ASTM E - 90-02 | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | FBC 1207.3 STRUCTURE-BORNE SOUND. ASTM E - 492-04 | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | | | | FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402 | | | SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO | | | DEMONSTRATE CODE COMPLIANCE BY THIS METHOD. | | | | | | _ OR _ | | | | | | FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE. | | | AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405 | | | (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE | | | SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE | | | COMPLIANCE BY SECTION 405. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
5 |
Status |
P |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-15 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-15 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2017-08-15 08:56:42 | NO CHANGES TO ELECTRICAL PREVIOUSLY APPROVED. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2017-08-03 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-08-03 |
Time |
10:47 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-08-03 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2017-07-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-27 |
Time |
07:52 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-27 |
Time |
07:52 |
Sent To |
|
|
| Notes |
| 2017-07-27 07:53:55 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS (3RD REVIEW): | | | | | | 1. THIS PREVIOUS COMMENT NOT ADDRESSED: ELECTRICAL PLAN | | | IS REQUIRED TO BE SIGNED AND SEALED BY A DESIGN | | | PROFESSIONAL OR THE ELECTRICAL CONTRACTOR QUALIFIER. FS | | | 471.003(2)(H); 471.025; FBC 107.2.1 | | | 2. THIS PREVIOUS COMMENT NOT ADDRESSED: PROVIDE PANEL | | | SCHEDULE AS PREVIOUSLY REQUESTED, INDICATING NEW OR | | | ALTERED CIRCUITS. ANY ALTERED CIRCUITS ARE REQUIRED TO | | | HAVE AFCI PROTECTION WHERE NORMALLY REQUIRED PER CODE. | | | NEC 210.12, 215.5 | | | 3. THIS PREVIOUS COMMENT NOT ADDRESSED COMPLETELY, | | | EXISTING OUTLETS IN DEN-BED ROOM NOT SHOWN, OUTLETS | | | NEED TO BE SPACED PER CODE: SHOW REQUIRED OUTLETS WHERE | | | POCKET DOOR IS REMOVED AND NEW WALL INSTALLED. NEC | | | 210.52 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-05 |
Time |
09:05 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-05 |
Time |
09:05 |
Sent To |
|
|
| Notes |
| 2017-07-05 09:24:27 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: | | | | | | 1. ELECTRICAL PLAN IS REQUIRED TO BE SIGNED AND SEALED | | | BY A DESIGN PROFESSIONAL OR THE ELECTRICAL CONTRACTOR | | | QUALIFIER. FS 471.003(2)(H); 471.025; FBC 107.2.1 | | | 2. ELECTRICAL PLAN PROVIDED SHALL BE A MINIMUM 1/8" | | | SCALE AS PREVIOUSLY REQUESTED. "BUILDING PLANS SHALL BE | | | DRAWN TO A MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL | | | PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. THIS POLICY | | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS | | | MANAGEMENT." WPB AMENDMENTS TO FBC 107.2.1.4 | | | 3. PROVIDE PANEL SCHEDULE AS PREVIOUSLY REQUESTED, | | | INDICATING NEW OR ALTERED CIRCUITS. ANY ALTERED | | | CIRCUITS ARE REQUIRED TO HAVE AFCI PROTECTION WHERE | | | NORMALLY REQUIRED PER CODE. NEC 210.12, 215.5 | | | 4. SHOW REQUIRED OUTLETS WHERE POCKET DOOR IS REMOVED | | | AND NEW WALL INSTALLED. NEC 210.52 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-06 |
Time |
10:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-06 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2017-06-06 10:59:02 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS: | | | | | | 1. PROVIDE ELECTRICAL PLAN FOR REVIEW. INFORMATION ON | | | CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS SHALL BE | | | DIMENSIONED AND DRAWN UPON SUITABLE MATERIAL. | | | ELECTRONIC MEDIA DOCUMENTS SHALL BE SUBMITTED WHEN | | | APPROVED BY THE BUILDING OFFICIAL. CONSTRUCTION | | | DOCUMENTS SHALL BE OF SUFFICIENT CLARITY TO INDICATE | | | THE LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED | | | AND SHOW IN DETAIL THAT IT WILL CONFORM TO THE | | | PROVISIONS OF THIS CODE AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL. SUCH DRAWINGS AND SPECIFICATIONS SHALL | | | CONTAIN INFORMATION, IN THE FORM OF NOTES OR OTHERWISE, | | | AS TO THE QUALITY OF MATERIALS, WHERE QUALITY IS | | | ESSENTIAL TO CONFORMITY WITH THE TECHNICAL CODES. SUCH | | | INFORMATION SHALL BE SPECIFIC, AND THE TECHNICAL CODES | | | SHALL NOT BE CITED AS A WHOLE OR IN PART, NOR SHALL THE | | | TERM "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE | | | FOR SPECIFIC INFORMATION. ALL INFORMATION, DRAWINGS, | | | SPECIFICATIONS AND ACCOMPANYING DATA SHALL BEAR THE | | | NAME AND SIGNATURE OF THE PERSON RESPONSIBLE FOR THE | | | DESIGN. FBC 107.2.1 (SEE ALSO SECTION 107.3.5). | | | 2. QUALITY OF BUILDING PLANS. BUILDING PLANS SHALL BE | | | DRAWN TO A MINIMUM 1/8 INCH SCALE UPON SUBSTANTIAL | | | PAPER, CLOTH OR OTHER ACCEPTABLE MEDIUM. THIS POLICY | | | MAY INCLUDE SUCH THINGS AS MINIMUM SIZE, SHAPE, | | | CONTRAST, CLARITY, OR OTHER ITEMS RELATED TO RECORDS | | | MANAGEMENT. FBC 107.2.1.4 | | | 3. PROVIDE ELECTRICAL RISER DIAGRAM. NEC 215.5 | | | 4. PROVIDE PANEL SCHEDULE INDICATING ANY NEW OR ALTERED | | | CIRCUITS, THEIR WIRE AND BREAKER SIZE. FBC 107.2.1, NEC | | | 408.4 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-08-23 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-23 |
Time |
11:00 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-08 |
Time |
14:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-02 |
Time |
16:20 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-17 |
Time |
15:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-11 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-11 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-22 |
Time |
13:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-06 |
Time |
15:08 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-05-12 |
Time |
10:47 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-17 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-17 |
Time |
09:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2017-07-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-25 |
Time |
12:21 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-25 |
Time |
12:16 |
Sent To |
|
|
| Notes |
| 2017-07-25 12:30:04 | 3RD REVIEW FBC-2014 MECHANICAL | | | PERMIT #17050594 | | | 7/25/17 | | | | | | 1) SHOW BEDROOM RETURNS, AND HOW THE AIR IS BEING | | | RETURNED FROM THE MAIN 16X16 GRILL TO THE AIR HANDLER- | | | SECTION 601.5. | | | | | | 2) SHOW THE BRANCH DUCT SUPPLYING THE KITCHEN AND | | | PROVIDE ALL BRANCH DUCT SIZES. | | | | | | 3) THE DUCT BOARD SHALL BE MINIMUM R-4.2 PER TABLE | | | C403.2.7.1 FBC-14 EBNERGY CONSERVATION. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-07-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-03 |
Time |
13:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-03 |
Time |
13:54 |
Sent To |
|
|
| Notes |
| 2017-07-03 14:08:34 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17050594 | | | 7/3/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) PROVIDE A SCOPE OF WORK OUTLINE ON THE PLAN. CLARIFY | | | IF A NEW AC SYSTEM AND DUCTWORK ARE BEING INSTALLED, OR | | | WHAT ALTERATIONS TO THE EXISTING SYSTEM ARE PROPOSED. | | | SHOW POINTS OF CONNECTION FOR NEW AND EXISTING DUCTWORK | | | IF APPLICABLE, AND PROVIDE AN AC EQUIPMENT SCHEDULE. | | | | | | 2) THE PLANS SHALL BEAR THE SIGNATURE OF THE PERSON WHO | | | PREPARED THE DESIGN- SECTION 107.2.1 WPB AMENDMENTS TO | | | THE FBC. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-06 |
Time |
11:16 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-06 |
Time |
11:16 |
Sent To |
|
|
| Notes |
| 2017-06-06 11:27:47 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17050594 | | | 6/6/17 | | | | | | RESULTS: DENIED. | | | | | | 1) PROVIDE MECHANICAL PLANS SHOWING THE RELOCATION OF | | | THE AC (PER THE WORK DESCRIPTION ON THE PERMIT | | | APPLICATION), AND ALL OTHER ALTERATIONS TO THE EXISTING | | | SYSTEMS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-08-22 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-22 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-22 |
Time |
08:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-07-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-26 |
Time |
08:44 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-26 |
Time |
06:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-07-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-07 |
Time |
13:42 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-07 |
Time |
12:29 |
Sent To |
|
|
| Notes |
| 2017-07-07 13:54:51 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLANS SHALL BE SIGNED BY PERSON RESPONSIBLE FOR THE | | | DESIGN. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-06 |
Time |
12:49 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-06 |
Time |
12:45 |
Sent To |
|
|
| Notes |
| 2017-06-06 12:55:46 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE APPLICATION INDICATES PLUMBING WORK BEING DONE, | | | NONE IS SHOWN ON THE PLANS PLEASE PROVIDE INFORMATION | | | AND DETAILS ON THE PLAN OF THE PLUMBING WORK TO BE | | | DONE. PER WPB AMEND TO FBC 107.2.1 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |