| Plan Review Stops For Permit 17050505 |
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-05-22 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-22 |
Time |
13:05 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-22 |
Time |
13:05 |
Sent To |
|
|
| Notes |
| 2017-05-22 13:07:19 | APPROVED WITH EXCEPTIONS | | | G2427.8 (503.8) VENTING SYSTEM TERMINATION LOCATION. | | | THE LOCATION OF VENTING SYSTEM TERMINATIONS SHALL | | | COMPLY WITH THE FOLLOWING (SEE APPENDIX C): | | | 1. A MECHANICAL DRAFT VENTING SYSTEM SHALL TERMINATE AT | | | LEAST 3 FEET (914 MM) ABOVE ANY FORCED-AIR INLET | | | LOCATED WITHIN 10 FEET (3048 MM). | | | 2. A MECHANICAL DRAFT VENTING SYSTEM, EXCLUDING | | | DIRECT-VENT APPLIANCES, SHALL TERMINATE AT LEAST 4 FEET | | | (1219 MM) BELOW, 4 FEET (1219 MM) HORIZONTALLY FROM, OR | | | 1 FOOT (305 MM) ABOVE ANY DOOR, OPERABLE WINDOW, OR | | | GRAVITY AIR INLET INTO ANY BUILDING. THE BOTTOM OF THE | | | VENT TERMINAL SHALL BE LOCATED AT LEAST 12 INCHES (305 | | | MM) ABOVE FINISHED GROUND LEVEL. |
|
|
|