|
 |
 |
 |
 |
 |
Plan Review Details - Permit 17050392
| Plan Review Stops For Permit 17050392 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-06-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-06-07 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-06-07 |
Time |
07:40 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-16 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-16 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-05-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-05-31 |
Time |
12:53 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-05-31 |
Time |
12:53 |
Sent To |
|
|
| Notes |
| 2017-05-31 13:13:29 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION | | | COMMENTS: | | | 1. LIGHTING IN CLOTHES CLOSET WITH OPEN LAMPS ARE NOT | | | PERMITTED. PROVIDE CORRECTION. NEC 410.16 (B) , FBC R | | | E4003.12 | | | 2. SHOW AFCI PROTECTION OF ANY NEW OR ALTERED CIRCUITS. | | | NEC 210.12 , FBC R E3902.12 | | | 3. SHOW DEDICATED OUTLET CIRCUIT FOR BATHROOM GFCI | | | RECEPTACLES. NEC 210.11(C)(3) , FBC R E3703.4 | | | 4. SHOW ALL REQUIRED OUTLETS IN ALTERED BEDROOM FOR | | | FLOOR SPACING. INDICATE ANY EXISTING OUTLETS. NEC | | | 210.52 , FBC R E3901.2 | | | 5. PROVIDE CORRECTION FOR SYMBOL DESCRIPTION IN LEGEND | | | FOR SMOKE ALARMS. CURRENT DESCRIPTION SHOWS A SMOKE | | | ALARM WITH A FIRE DAMPER. FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-16 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-09 |
Time |
13:35 |
Sent To |
|
|
| Notes |
| 2017-06-16 08:57:12 | PLACED IN "TO BE PROCESSED" BOX. JP | | 2017-06-12 13:35:50 | RESUB ROUTED TO GJOHNSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-06-07 |
Time |
09:18 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-09 |
Time |
12:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-14 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-14 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-14 |
Time |
11:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-24 |
Time |
15:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-24 |
Time |
15:34 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |