Plan Review Details - Permit 17050343
| Plan Review Stops For Permit 17050343 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-15 |
Time |
18:31 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-15 |
Time |
18:25 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-06-07 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-06-07 |
Time |
15:51 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-06-07 |
Time |
15:51 |
Sent To |
|
|
| Notes |
| 2017-06-07 15:52:02 | ALL POOL EQUIPMENT IS EXISTING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-05-16 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-16 |
Time |
16:07 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-16 |
Time |
16:07 |
Sent To |
|
|
| Notes |
| 2017-05-16 16:08:10 | CONTRACTOR CALLED AND STATED THAT ALL OF THE POOL | | | EQUIPMENT IS EXISTING. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-15 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-15 |
Time |
18:55 |
Sent To |
|
|
| Notes |
| 2017-05-15 18:55:43 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY ELECTRICAL | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) THE PLANS DO NOT SPECIFY IF THE POOL HEATER IS NEW | | | OR EXISTING. SHOW THE POOL HEATER AND WIRE SIZES FOR IT | | | ON THE ELECTRICAL SCHEMATIC DIAGRAM. FBC 107.2.1 | | | | | | 2) SUBMIT TWO COPIES OF THE MANUFACTURER'S | | | SPCIFICATIONS FOR THE POOL HEATER. FBC 107.2.1 & | | | FBCR-E4206.12 | | | | | | 3) SUBMIT ELECTRICAL LOAD CALCULATIONS FOR THE DWELLING | | | TO SHOW THAT THE EXISTING SERVICE IS ADEQUATE FOR THE | | | NEW POOL EQUIPMENT. FBCR-E3602.2 | | | | | | 4) SHOW COMPLIANCE WITH FBC ENERGY CONSERVATION | | | R403.9.3 FOR THERMAL POOL COVER. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-15 |
Time |
18:55 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-08 |
Time |
12:36 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-05-12 |
Time |
02:55 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-05-12 |
Time |
02:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-07 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-06-07 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-06-07 |
Time |
15:33 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-15 |
Time |
18:56 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-05-09 |
Time |
15:54 |
Sent To |
|
|
| Notes |
| 2017-05-10 17:23:56 | 5/10/17- FAILED | | | | | | POOL EQUIPMENT MUST BE 12FT FROM REAR PROPERTY LINE | | | | | | | | | PLEASE CONTACT | | | NATHAN WIRA- ZONING TECHNICIAN | | | DEVELOPMENT SERVICES DEPARTMENT ? PLANNING AND ZONING | | | DIVISION | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS ST. | | | WEST PALM BEACH, FL 33402 | | | OFFICE HOURS: M-F 8AM - 5PM | | | (561)822-1442 | | | [email protected] | | | |
|
|
|