Plan Review Details - Permit 17050241
Plan Review Stops For Permit 17050241
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-07 Cont ID  
Sent By cthroop Date 2017-06-07 Time 15:56 Rev Time 0.00
Received By cthroop Date 2017-06-07 Time 15:56 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-17 Cont ID  
Sent By cthroop Date 2017-05-17 Time 10:00 Rev Time 0.00
Received By cthroop Date 2017-05-17 Time 09:58 Sent To P
Notes
2017-05-17 10:10:31BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PLUMBING PERMIT REQUIRED. PROVIDE WATER AND SANITARY
 PLAN.
 2. ELECTRICAL PERMIT REQUIRED. PROVIDE ELECTRICAL PLAN.
 3. VALUE APPEARS LOW FOR SOW.
 4. CONFLICTING STATEMENT ON PLANS LOCATED INSIDE
 PROPOSED ENCLOSURE - NEW PROPOSED. PLEASE CLARIFY.
 5. PLAN SHOWS DETAIL A - NO DETAIL A PROVIDED. PROVIDE
 ATTACHMENT DETAIL FOR 2X4 WOOD FRAMED WALL TO EXISTING
 CMU WALL.
  
 THE STATED VALUE APPEARS LOW FOR THE PROPOSED SCOPE OF
 WORK.
 THE PERMIT VALUATION AND PERMIT FEE MUST BE
 COMMENSURATE WITH THE VALUATION AND FEE THAT A LICENSED
 CONTRACTOR WOULD PROVIDE.
 YOU MAY PROVIDE A COPY OF THE CONTRACT SIGNED BY THE
 OWNER OR A LIST OF LABOR, MATERIALS AND EQUIPMENT
 RENTAL TO VERIFY VALUE.
  
 CITY OF WPB CHPT. 1 - VALUE
 109.3 BUILDING PERMIT VALUATIONS. IF, IN THE OPINION OF
 THE BUILDING OFFICIAL, THE CLAIMED VALUATION OF
 BUILDING, ALTERATION, STRUCTURE, ELECTRICAL, GAS,
 MECHANICAL OR PLUMBING SYSTEMS APPEARS TO BE
 UNDERESTIMATED ON THE APPLICATION, THE PERMIT SHALL BE
 DENIED, UNLESS THE APPLICANT CAN SHOW DETAILED,
 QUANTITY ESTIMATES, AND/OR BONA FIDE SIGNED CONTRACTS
 (EXCLUDING LAND VALUE) TO MEET THE APPROVAL OF THE
 BUILDING OFFICIAL. FOR PERMITTING PURPOSES, VALUATION
 OF BUILDINGS AND SYSTEMS SHALL BE TOTAL REPLACEMENT
 VALUE TO INCLUDE STRUCTURAL, ELECTRIC, PLUMBING,
 MECHANICAL, INTERIOR FINISH, RELATIVE SITE WORK,
 ARCHITECTURAL AND DESIGN FEES, MARKETING COSTS,
 OVERHEAD AND PROFIT; EXCLUDING ONLY LAND VALUE.
 VALUATION REFERENCES MAY INCLUDE THE LATEST PUBLISHED
 DATA OF NATIONAL CONSTRUCTION
 COST ANALYSIS SERVICES (MARSHALL-SWIFT, MEANS, ETC.),
 AS PUBLISHED BY INTERNATIONAL CODE CONGRESS.
 FINAL BUILDING PERMIT VALUATION SHALL BE SET BY THE
 BUILDING OFFICIAL.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  

Review Stop E ELECTRICAL
Rev No 2 Status N Date 2017-06-06 Cont ID  
Sent By jleahy Date 2017-06-06 Time 17:29 Rev Time 0.00
Received By jleahy Date 2017-06-06 Time 17:29 Sent To P
Notes
2017-06-06 17:30:04NO ELECTRICAL WORK SHOWN ON DRAWINGS JLEAHY

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-05-19 Cont ID  
Sent By jleahy Date 2017-05-19 Time 16:47 Rev Time 0.00
Received By jleahy Date 2017-05-19 Time 16:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-06-06 Cont ID  
Sent By cthroop Date 2017-06-07 Time 15:56 Rev Time 0.00
Received By wjolin Date 2017-06-06 Time 11:33 Sent To E
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-05-05 Cont ID  
Sent By wjolin Date 2017-05-05 Time 12:25 Rev Time 0.00
Received By wjolin Date 2017-05-05 Time 12:05 Sent To B
Notes
2017-05-05 12:25:55FIRE SPRINKLER PROTECTION NEEDED INSIDE THE NEW
 ENCLOSURE.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-06-07 Cont ID  
Sent By cthroop Date 2017-06-07 Time 15:56 Rev Time 0.00
Received By cthroop Date 2017-06-02 Time 11:56 Sent To FIRE
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-19 Cont ID  
Sent By jleahy Date 2017-05-19 Time 16:47 Rev Time 0.00
Received By jleahy Date 2017-05-04 Time 16:43 Sent To  
Notes
2017-05-04 16:43:29ROUTED TO FIRE INBOX

Review Stop P PLUMBING
Rev No 2 Status N Date 2017-06-07 Cont ID  
Sent By tklarge Date 2017-06-07 Time 03:53 Rev Time 0.00
Received By tklarge Date 2017-06-07 Time 03:41 Sent To  
Notes
2017-06-07 03:55:08THE PLANS NOTE THAT A NEW ENCLOSURE IS BEING
 CONSTRUCTED AROUND THE EXISTING WASHER/DRYER AND THAT
 THERE WILL BE NO CHANGES OR ALTERATIONS TTO THE
 EXISTING PLUMBING SYSTEM.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-05-18 Cont ID  
Sent By gjohnson Date 2017-05-18 Time 17:21 Rev Time 0.00
Received By gjohnson Date 2017-05-18 Time 17:21 Sent To E
Notes
2017-05-18 17:24:551ST REVIEW: FBC 2014 5TH EDITION
  
 PLUMBING COMMENTS: 5/18/17 DENIED
  
 1. PROVIDE SANITARY AND WATER RISER DIAGRAM. PER WPB
 AMEND TO FBC 107.3.5.1.3(13)
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS.
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER
 CITY OF WEST PALM BEACH
  561-805-6711
 [email protected]
  