| 2017-05-18 10:14:26 | 2014 FBC- BUILDING PLAN REVIEW |
| | W. P. B. PERMIT: 17050096 |
| | W.P.B. PRIME: 16040632 |
| | ADD: 3001 OKEECHOBEE BLVD/ MEZZANINE |
| | CONT: FLORES CONSTRUCTION |
| | TEL: 813-323-7895 |
| | E-MAIL: [email protected] |
| | |
| | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, |
| | ADMINISTRATION |
| | |
| | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. |
| | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND |
| | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE |
| | FLORIDA BUILDING CODE, BUILDING. |
| | |
| | 1ST REVIEW |
| | DATE: THURS. MAY 18, 2017 |
| | ACTION: DENIED |
| | |
| | 1) THE SET OF STEEL MEZZANINE DRAWINGS BY GILBERTO |
| | RAMOS P. E. HAVE NOT BEEN REVIEWED AND APPROVED BY THE |
| | DESIGNER OF RECORD ARCHITECT KEITH SPINA . FL |
| | 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR |
| | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, |
| | SHOP DRAWINGS ETC... |
| | 2) THE PLANS DO NOT STATE COMPLIANCE WITH: |
| | 2A) PLANS DO NOT GIVE THE LIVE LOAD REQUIREMENTS FOR |
| | THE MEZZANINE STORAGE2014 FBC-B TABLE 1607.1(31) IN |
| | LBS. 125 PSF LIGHT OR 250 PSF HEAVY. |
| | 2B) THE PLANS DO NOT PROVIDE COMPLIANCE WITH 2014 FBC-B |
| | TABLE 1607.1 STAIRS (30) 100/ 300 FOOTNOTE F |
| | FOOTNOTE F. THE MINIMUM CONCENTRATED LOAD ON STAIR |
| | TREADS SHALL BE APPLIED ON AN AREA OF 2 INCHES BY 2 |
| | INCHES. THIS LOAD NEED NOT BE ASSUMED TO ACT |
| | CONCURRENTLY WITH THE UNIFORM LOAD. |
| | |
| | 2C) SHOW COMPLIANCE WITH 2014 FBC-B HANDRAILS AND |
| | GUARDS: |
| | 2C)(1)1607.8.1.1 CONCENTRATED LOAD. HANDRAILS AND |
| | GUARDS SHALL ALSO BE DESIGNED TO RESIST A CONCENTRATED |
| | LOAD OF 200 POUNDS IN ACCORDANCE WITH SECTION 4.5.1 OF |
| | ASCE 7. |
| | |
| | 2C)(2) 1607.8.1.2 INTERMEDIATE RAILS. INTERMEDIATE |
| | RAILS (ALL THOSE EXCEPT THE HANDRAIL), BALUSTERS AND |
| | PANEL FILLERS SHALL BE DESIGNED TO RESIST A |
| | CONCENTRATED LOAD OF 50 POUNDS IN ACCORDANCE WITH |
| | SECTION 4.5.1 OF ASCE 7. |
| | |
| | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION |
| | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS |
| | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A |
| | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT |
| | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, |
| | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE |
| | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. |
| | THANK YOU FOR YOUR ANTICIPATED COOPERATION. |
| | |
| | JAMES A. WITMER BN, PX, CBO |
| | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER |
| | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES |
| | DEPARTMENT |
| | 401 CLEMATIS ST. |
| | WEST PALM BEACH. FL 33402 |
| | TEL: 561-805-6715 |
| | FAX: 561-805-6676 |
| | E-MAIL: [email protected] |
| | |
| | |
| | |
| | |
| | |