| Plan Review Stops For Permit 17050074 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-07 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-07 |
Time |
12:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-11 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-11 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-06-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-26 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-26 |
Time |
12:25 |
Sent To |
|
|
| Notes |
| 2017-06-26 12:25:24 | PROVISO - ALL PLYWOOD TO BE FRT | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-26 |
Time |
13:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-25 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2017-05-26 13:59:59 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | REVIEW #1 (FIRST PERMIT APPLICATION SUBMITTAL) | | | | | | 1. ARCHITECT BUSINESS LICENSE (26001393) IS REQUIRED TO | | | BE A PART OF THE TITLE BLOCK, FS481, FAC61G15. ADD TO | | | ALL REVISED PAGES (IT APPEARS ALL SHEETS WILL BE | | | REVISED DUE TO ADDRESS CORRECTION). | | | | | | 2. PLAN IS FOR 1751 PALM BEACH LAKES W311, APPLICATION | | | IS 1771 PALM BEACH LAKES W311. VERIFY ADDRESS; REVISE | | | PLAN ACCORDINGLY. OUR RECORDS SHOW THAT THIS SPACE WAS | | | PREVIOUSLY "KENNETH COLE"; IS THIS CORRECT? | | | | | | 3. PROVIDE PRODUCT APPROVAL FOR THE PROPOSED EXTERIOR | | | DOORS AND STOREFRONT, FBC B 1609. | | | | | | 4. FBC B 603.1, DETAIL M A04.1, REVISE PLAN TO CLARIFY | | | WHAT "PLANKING SF-90" IS. IF THIS IS A COMBUSTIBLE, | | | PROVIDE MORE INFORMATION TO SHOW COMPLIANCE WITH FBC B | | | 801, 803. | | | | | | 5. VARIOUS PAGES APPEAR TO SHOW MYLAR AND TINTING | | | INSTALLED OVER IMPACT GLASS PRODUCTS. VERIFY WITH | | | MANUFACTURER THAT THIS DOES NOT AFFECT THE IMPACT AND | | | PRESSURE REQUIREMENTS. NO RESPONSE NECESSARY OTHER THAN | | | TO ACKNOWLEDGE (IN RESPONSE LETTER) AND REVISE IF | | | NECESSARY; ISSUED AT APPLICANT'S RISK. | | | | | | 6. THERE ARE A NUMBER OF REDLINED ITEMS WHICH APPEAR TO | | | BE FROM THE LANDLORD. AT LEAST ONE STATES "REVISE AND | | | RESUBMIT" (A08.3). | | | | | | NO ONE OTHER THAN THE DESIGN PROFESSIONAL CAN ALTER THE | | | DESIGN OF THAT PROFESSIONAL, FS471,481. IT IS NOT CLEAR | | | HOW SOME ITEMS AFFECT CODE COMPLIANCE - FOR INSTANCE, | | | LED PANEL EMILINATED ON SHEET A08.3. | | | | | | REVISE THE PLAN TO INCORPORATE THE CHANGES WHICH AFFECT | | | CODE COMPLIANCE. WHEN RESUBMITTING, PROVIDE "CLEAN" | | | PAGES. ONE PDF WITH A REVIEW STAMP BY THE LANDLORD IS | | | ONE WAY TO DEMONSTRATE REVIEW; ANOTHER OPTION WOULD BE | | | A COVER LETTER REFERRING TO SPECIFIC PLANS AND PAGES. | | | | | | 7. DETAIL A 08.5 AND POSSIBLY OTHER LOCATIONS, THERE IS | | | A STATEMENT REGARDING EXTERIOR GRADE PLYWOOD. FBC B | | | 603.1, CLARIFY AMOUNT OF PLYWOOD PROPOSED WHICH IS NOT | | | FRT (OTHER THAN CABINETRY; NOTE IS ON STOREFRONT | | | DETAILS PAGE), REVISE PLAN TO INCORPORATE APPLICABLE | | | EXCEPTION, OR REMOVE OR MODIFY NOTE. (NOTE THAT DETAIL | | | K-A12.1 SPECS FRT.) | | | | | | 8. SEPARATE PERMITS (APPLICATIONS, PLANS, REVIEWS, | | | FEES) REQUIRED FOR SIGNS. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-28 |
Time |
09:23 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-28 |
Time |
09:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-06-01 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-01 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-01 |
Time |
14:25 |
Sent To |
|
|
| Notes |
| 2017-06-02 09:12:31 | PLANS NOT SIGNED AND SEALED PER FS. 06/02/17 JP | | 2017-06-01 14:34:48 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | 1ST REVIEW COMMENTS: | | | | | | 1. SHEET E03.01, KEY NOTE 6, STATES THAT THE EXIT AND | | | EMERGENCY LIGHTS SHOULD BE ON CIRCUIT A-1. NEC REQUIRES | | | THAT THESE ITEMS BE WIRED TO THE NORMAL LIGHTING | | | CIRCUIT IN THE AREA. PROVIDE CORRECTION. NEC 700.12(F) | | | 2. PROVIDE SHORT CIRCUIT CALCULATION FOR THE AVAILABLE | | | FAULT CURRENT AT THE SERVICE. AN ASSUMED AMOUNT IS NOT | | | ACCEPTABLE. NEC 110.10 | | | 3. PROVIDE MANUFACTURERS SPEC SHEET FOR SWITCHGEAR | | | "IFS" TO VERIFY LISTING. NEC 110.3 | | | 4. ADDRESS NEEDS VERIFICATION. FBC 107.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-06-21 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-06-21 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
wjolin |
Date |
2017-05-18 |
Time |
08:10 |
Rev Time |
0.00 |
| Received By |
wjolin |
Date |
2017-05-18 |
Time |
07:09 |
Sent To |
|
|
| Notes |
| 2017-05-18 08:10:44 | 1771 OR 1751 PALM BEACH LAKES BOULEVARD - #W311 | | | PERMIT #17050074 | | | REVIEW COMMENTS - FIRE DEPARTMENT | | | | | | THE ADDRESS OF THE PERMIT IS INDICATED AS 1771 PALM | | | BEACH LAKES BOULEVARD; HOWEVER, THE PERMIT APPLICATION | | | AND PLANS INDICATE AN ADDRESS OF 1751 PALM BEACH LAKES | | | BOULEVARD. | | | | | | UPDATE THE CODE LIST TO REFERENCE THE 5TH EDITION OF | | | THE FLORIDA FIRE PREVENTION CODE WHICH CONTAINS THE | | | 2012 EDITION OF BOTH NFPA 1 AND NFPA 101 WITH FLORIDA | | | AMENDMENTS. | | | | | | NO ENGINEERED FIRE ALARM DRAWINGS SUBMITTED. PER FBC | | | SECTION 907.1.1 CONSTRUCTION DOCUMENTS - "CONSTRUCTION | | | DOCUMENTS FOR FIRE ALARM SYSTEMS SHALL BE OF SUFFICIENT | | | CLARITY TO INDICATE THE LOCATION, NATURE AND EXTENT OF | | | THE WORK PROPOSED AND SHOW IN DETAIL THAT IT WILL | | | CONFORM TO THE PROVISIONS OF THIS CODE, THE FLORIDA | | | FIRE PREVENTION CODE, AND RELEVANT LAWS, ORDINANCES, | | | RULES AND REGULATIONS, AS DETERMINED BY THE BUILDING | | | OFFICIAL." | | | | | | WESLEY JOLIN | | | ASSISTANT FIRE MARSHAL | | | WEST PALM BEACH FIRE RESCUE | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
7 |
Status |
N |
Date |
2017-08-10 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-08-10 |
Time |
16:13 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-04 |
Time |
08:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
6 |
Status |
N |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-02 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-01 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2017-08-01 14:23:01 | HARD COPIES OF SIGNATURES ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2017-07-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-28 |
Time |
14:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-25 |
Time |
08:51 |
Sent To |
|
|
| Notes |
| 2017-07-28 08:51:43 | SIGNATURES GIVEN TO SHILL - HARD COPIES |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-07-24 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-07-24 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-07-20 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2017-07-20 14:08:13 | SIGNATURES ROUTED TO SKENNEDY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-07-14 |
Time |
14:08 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-07-07 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-16 |
Time |
12:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-06-06 |
Time |
08:17 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-05-16 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-10 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-10 |
Time |
11:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-07-13 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-13 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-13 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-30 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-30 |
Time |
10:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-30 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2017-06-30 10:59:23 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17050074 | | | 6/30/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) CONTRARY TO THE SUBMITTED RESPONSE NARRATIVE FROM | | | THE ARCHITECT MOODY NOLAN INC., THE PLANS ARE STILL | | | INDICATING DEMOLITION OF THE EXISTING RTU AND | | | INSTALLATION OF A NEW JOHNSON CONTROLS SYSTEM. IF THE | | | EXISTING YORK UNIT IS TO REMAIN IN PLACE AS THE | | | NARRATIVE SEEMS TO INDICATE, THEN PLEASE REVISE THE | | | PLANS ACCORDINGLY. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-25 |
Time |
17:13 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-25 |
Time |
17:13 |
Sent To |
|
|
| Notes |
| 2017-05-25 17:34:52 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17050074 | | | 5/25/17 | | | | | | RESULTS: DENIED. | | | | | | 1) THE AC COOLING AND HEATING CALCULATIONS ON SHEET | | | M04.01 INDICATE THE RTU SELECTED IS UNDERSIZED IN BOTH | | | COOLING AND HEATING CAPACITY- SEE AC SCHEDULE ON SHEET | | | M0.01. | | | | | | 2) PROVIDE THE WIND LOAD DESIGN CRITERIA, AND | | | STRUCTURAL DETAILS BY A FL. REGISTERED ENGINEER FOR | | | INSTALLATION OF THE NEW RTU- SECTION 301.15. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
P |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-24 |
Time |
15:17 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-24 |
Time |
15:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
7 |
Status |
P |
Date |
2017-08-07 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-07 |
Time |
12:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-07 |
Time |
12:33 |
Sent To |
|
|
| Notes |
| 2017-08-07 12:33:49 | PROVISO | | | ANY NEW SHEETS SUBMITTED AFTER 8/4/17 NEED SIGNATURE | | | REVIEW | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
6 |
Status |
F |
Date |
2017-08-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-08-02 |
Time |
09:30 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-02 |
Time |
09:30 |
Sent To |
|
|
| Notes |
| 2017-08-02 09:35:37 | ****CORRECTIONS**** | | | REVISED 8/3/17 | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. MECHANICAL AND PLUMBING SHEETS IN PROJECT DOX WERE | | | PREPARED BY ROBERT A. HARRIS, PE. THE PAPER PLANS | | | PROVIDED WERE SIGNED AND SEALED BY ADRIAN T. FRANKS, | | | PE. | | | | | | 2. OK | | | | | | 3. OK | | | | | | **************************** | | | NOTES: | | | ARCHITECTURAL SHEETS OK | | | STRUCTURAL SHEETS OK | | | ELECTRICAL SHEETS OK | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
5 |
Status |
F |
Date |
2017-07-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-28 |
Time |
14:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-28 |
Time |
14:40 |
Sent To |
|
|
| Notes |
| 2017-07-28 14:42:40 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | ARCHITECTURAL SHEETS OK | | | STRUCTURAL SHEETS HAVE A PHOTOCOPY SIGNATURE (NOT | | | ACCEPTABLE, SEE FLORIDA STATUTE 471) | | | MEP SHEETS DO NOT HAVE A SIGNATURE, SEAL, OR COMPLIANT | | | TITLE BLOCK (ENGINEER'S PRINTED NAME AND LICENSE NUMBER | | | REQUIRED) | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
4 |
Status |
F |
Date |
2017-07-20 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2017-07-20 |
Time |
14:10 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2017-07-20 |
Time |
14:10 |
Sent To |
|
|
| Notes |
| 2017-07-20 14:20:28 | 4ST REVIEW FBC 2014 EXISTING BUILDING | | | | | | THE PAPER SUBMITTED PLANS DO NOT CONTAIN ORIGINAL | | | SIGNATURES AND SEALS EXCEPT THE COVER SHEET. A&S SHEETS | | | ARE PHOTO COPIES, MEP SHEETS ARE NOT SIGNED AND HAVE NO | | | SEAL. | | | | | | STEVEN KENNEDY, CBO | | | ASSISTANT BUILDING OFFICIAL | | | (561) 805-6710 | | | [email protected] | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
3 |
Status |
F |
Date |
2017-07-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-07-11 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-07-11 |
Time |
08:18 |
Sent To |
|
|
| Notes |
| 2017-07-11 08:25:58 | PLANS NOT SIGNED AND SEALED PER FS. 06/02/17 JP | | | | | | | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | PLANS ARE NOT SIGNED AND SEALED IN ACCORDANCE WITH | | | FLORIDA STATUTES 471, FS481. | | | | | | SEE ALSO: | | | | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.003, 61G16-005. | | | | | | TO RESOLVE, AFTER ALL REVIEWS HAVE PASSED, EITHER: | | | | | | UPLOAD DIGITALLY SIGNED AND SEALED PLANS WHICH ARE | | | IDENTICAL TO THE PLANS REVIEWED, OR | | | | | | SUBMIT PAPER SIGNED, SEALED, DATED ORIGINALS | | | | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
2 |
Status |
F |
Date |
2017-06-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-06-26 |
Time |
12:25 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-06-26 |
Time |
12:24 |
Sent To |
|
|
| Notes |
| 2017-06-30 11:03:18 | MECHANCIAL PLANS ARE NOT ELECTRONICALLY SIGNED AND | | | SEALED- CCOLE- 6/30/17 | | 2017-06-30 09:57:26 | PLANS NOT SIGNED AND SEALED PER FS. 06/02/17 JP | | | | | | | | | | | | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | PLANS ARE NOT SIGNED AND SEALED IN ACCORDANCE WITH | | | FLORIDA STATUTES 471, FS481. | | | | | | SEE ALSO: | | | | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.003, 61G16-005. | | | |
|
|
| Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
| Rev No |
1 |
Status |
F |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-25 |
Time |
17:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-25 |
Time |
17:11 |
Sent To |
|
|
| Notes |
| 2017-06-02 09:13:41 | PLANS NOT SIGNED AND SEALED PER FS. 06/02/17 JP | | | | | | | | | | | 2017-05-25 17:14:33 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | PLANS ARE NOT SIGNED AND SEALED IN ACCORDANCE WITH | | | FLORIDA STATUTES 471, FS481. | | | | | | SEE ALSO: | | | | | | FLORIDA ADMINISTRATIVE CODE 61G15-23.003, 61G16-005. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-07-14 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-07-14 |
Time |
13:38 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2017-07-14 |
Time |
13:36 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-06-28 |
Time |
17:55 |
Rev Time |
0.25 |
| Received By |
eschneid |
Date |
2017-06-28 |
Time |
17:45 |
Sent To |
|
|
| Notes |
| 2017-06-28 17:55:51 | FAILED | | | | | | PROVIDE RESPONSE IN WRITING. | | | | | | 1) REPEAT COMMENT: THE DEMOLITION PLAN CALLS FOR THE | | | EXISTING ROOFTOP UNIT AND CURB TO BE REMOVED. THE PALM | | | BEACH OUTLETS DESIGN REGULATIONS REQUIRE THAT ROOFTOP | | | EQUIPMENT IS SCREENED FROM VIEW. PROVIDE CROSS SECTIONS | | | OR SIGHT LINE DRAWINGS TO VERIFY THAT THE FULL HEIGHT | | | OF THE NEW ROOFTOP UNIT (ON ITS CURB) IS SCREENED FROM | | | VIEW. THE PERMIT RESPONSE STATED THAT THE EXISTING | | | ROOFTOP EQUIPMENT IS TO REMAIN; HOWEVER THIS IS NOT | | | REFLECTED ON AN UPDATED DEMOLITION PLAN. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-06-05 |
|
|
Cont ID |
|
| Sent By |
eschneid |
Date |
2017-06-05 |
Time |
16:39 |
Rev Time |
0.75 |
| Received By |
eschneid |
Date |
2017-06-05 |
Time |
16:39 |
Sent To |
|
|
| Notes |
| 2017-06-05 16:44:16 | FAILED | | | | | | PROVIDE RESPONSE IN WRITING. | | | | | | 1) THE DEMOLITION PLAN CALLS FOR THE EXISTING ROOFTOP | | | UNIT AND CURB TO BE REMOVED. THE PALM BEACH OUTLETS | | | DESIGN REGULATIONS REQUIRE THAT ROOFTOP EQUIPMENT IS | | | SCREENED FROM VIEW. PROVIDE CROSS SECTIONS OR SIGHT | | | LINE DRAWINGS TO VERIFY THAT THE FULL HEIGHT OF THE NEW | | | ROOFTOP UNIT (ON ITS CURB) IS SCREENED FROM VIEW. | | | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1446. | | | [email protected] | | | | | | |
|
|