| Plan Review Stops For Permit 17050053 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-11 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-11 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2017-08-11 12:10:39 | BUILDING REVIEW APPROVED WITH PROVISO: | | | | | | 1- SURVEYOR TO PROVIDE FINAL ELEVATION CERTIFICATE | | | AFTER THE A/C EQUIPMENT PAD IS ELEVATED. NOTE: SURVEYOR | | | TO PROVIDE FINAL ELEVATION CERTIFICATE WITH ORIGINAL | | | SEAL AND SIGNATURE. COPIES ARE NOT ALLOWED BY CHAPTER | | | 472 F.S. WHEN SUBMITTING DOCUMENTS FOR PUBLIC RECORD. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-08-07 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-07 |
Time |
11:07 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-07 |
Time |
09:38 |
Sent To |
|
|
| Notes |
| 2017-08-07 09:53:58 | RESIDENTIAL (R3) ALTERATION, THIRD BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | 1- ELEVATION CERTIFICATE: | | | A) THE REVISED ELEVATION CERTIFICATE STILL SHOWS 7.32' | | | AS THE FINISH FLOOR ELEVATION FOR THE A/C EQUIPMENT. | | | CITY CODE SEC. 94-546(B)(1) REQUIRES FINISH ELEVATION | | | TO BE 1 FOOT ABOVE THE BASE FLOOD ELEVATION. THE BASE | | | FLOOR ELEVATION FOR FLOOD ZONE A5 IS 7'-0". NEED 8'-0" | | | MIN. EQUIPMENT NEEDS TO BE ELEVATED AND THE ELEVATION | | | CERTIFICATE NEEDS TO BE REVISED AS WELL. | | | | | | B) THE REVISED ELEVATION CERTIFICATE NEEDS TO HAVE THE | | | SURVEYOR ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY | | | CHAPTER 472 F.S. WHEN SUBMITTING PLANS FOR PUBLIC | | | RECORDS. | | | | | | | | | 2- REVISED SHEETS A-2 AND A-3 ARE MISSING THE | | | ENGINEER'S SIGNATURE AND DATE AS REQUIRED BY CHAPTER | | | 471 F.S WHEN SUBMITTING PLANS FOR PUBLIC RECORDS. | | | | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-06-30 |
Time |
11:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-06-29 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2017-06-29 17:31:07 | RESIDENTIAL (R3) ALTERATION, SECOND BUILDING REVIEW | | | CHECKLIST. | | | CODE: FBC 5TH EDITION (2014). | | | | | | | | | 1- THIS PROPERTY IS LOCATED IN FLOOD ZONE A5. ACCORDING | | | TO PALM BEACH COUNTY PROPERTY APPRAISER, THE VALUE OF | | | THE STRUCTURE ALONE IS $78,387. IT APPEARS THAT THE | | | VALUE OF THE PROPOSED WORK WILL TRIGGER THE SUBSTANTIAL | | | IMPROVEMENT REQUIREMENTS OF THE CITY OF WEST PALM BEACH | | | FLOODPLAIN MANAGEMENT POLICY. THE ELEVATION CERTIFICATE | | | PROVIDED SHOWS 7.96' AS THE FINISH FLOOR ELEVATION FOR | | | THE HOUSE AND 7.32 FOR THE A/C EQUIPMENT. CITY CODE | | | SEC. 94-546(B)(1) REQUIRES FINISH ELEVATION TO BE 1 | | | FOOT ABOVE THE BASE FLOOD ELEVATION. THE BASE FLOOR | | | ELEVATION FOR FLOOD ZONE A5 IS 7'-0". NEED 8'-0" MIN. | | | | | | | | | NOTE: | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | | FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-26 |
Time |
16:53 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-05-26 |
Time |
13:57 |
Sent To |
Z |
|
| Notes |
| 2017-05-26 16:59:57 | RESIDENTIAL (R3) ALTERATION, BUILDING REVIEW COMMENTS. | | | CODE: FBC 5TH EDITION (2014). | | | | | | 1- VALUATION DECLARED IN THE PERMIT APPLICATION IS | | | EXTREMELY LOW. VALUATION TO INCLUDE ALL THE SCOPE SCOPE | | | OF WORK INCLUDING LABOR, MATERIALS, CONTRACTOR'S | | | OVERHEAD AND PROFIT AND ALL DESIGN PROFESSIONAL FEES AS | | | REQUIRED BY SEC. 109.3 CITY AMENDMENTS. VALUATION WAS | | | UPDATED TO +/- $40,000. THE PERMIT FEE BALANCE IS | | | $2578.68. | | | | | | 2- THIS PROPERTY IS LOCATED IN FLOOD ZONE A5. BASED ON | | | THE VALUE OF THE BUILDING ALONE, ACCORDING TO THE PALM | | | BEACH COUNTY PROPERTY APPRAISER, IT LOOKS LIKE THE | | | PROPOSED SCOPE OF WORK AND WORK PERFORMED IN THE PAST | | | WILL TRIGGER THE SUBSTANTIAL IMPROVEMENT REQUIREMENTS | | | OF THE CITY OF WEST PALM BEACH FLOODPLAIN MANAGEMENT | | | POLICY. PLEASE PROVIDE COPY OF THE SURVEY (2 COPIES) | | | SHOWING THE EXISTING FINISH FLOOR ELEVATION OF THE | | | HOUSE TO VERIFY IF THE HOUSE COMPLIES WITH THE MINIMUM | | | FINISH FLOOR ELEVATION REQUIRED. SEC. 94- 541 CITY | | | CODE. | | | NOTE: ELEVATION CERTIFICATE IS REQUIRED FOR PROPERTIES | | | LOCATED IN THE FLOOD ZONE. | | | | | | 3- SHEET A-3: | | | A) PLANS NEED TO SPECIFY THE DESIGN CRITERIA INCLUDING | | | THE CURRENT CODE, WIND LOADS (ULTIMATE AND NOMINAL), | | | BUILDING EXPOSURE, ETC. AS REQUIRED BY CHAPTER 553 | | | FLORIDA STATUTES AND SEC. R301.1 FBC-RESIDENTIAL, 5TH | | | EDITION (2014). | | | | | | B) THE EXISTING DEN SHOWN ON THE EXISTING FLOOR PLAN IS | | | CONVERTED INTO A BEDROOM. REVISE THE NAME OF ROOM ON | | | THE "AS BUILT FLOOR PLAN" AND "ELECTRICAL FLOOR PLAN". | | | SPECIFY BEDROOM. SEC. 102.2 AND 107.2.1 CITY | | | AMENDMENTS. | | | | | | C) SCALE SPECIFIED ON THE FLOOR PANS ON SHEET A-3 IS | | | INCORRECT. REVISE AS REQUIRED. SEC. 107.2.1 CITY | | | AMENDMENTS. | | | | | | | | | NOTE: | | | ***PLEASE PROVIDE RESPONSE LETTER ADDRESSING EACH | | | COMMENT TO EXPEDITE THE REVIEW PROCESS. | | | ***PLEASE INSERT ANY REVISED DRAWING AND REMOVE OLD | | | DRAWING. DON'T STAPLE OLD DRAWINGS. SUBMIT OLD DRAWINGS | | | FOR REFERENCE. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-07-05 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-05 |
Time |
10:16 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-05 |
Time |
10:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-23 |
Time |
13:30 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-23 |
Time |
12:54 |
Sent To |
|
|
| Notes |
| 2017-05-23 13:29:57 | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | 1ST REVIEW FBC 2014 EXISTING BUILDING | | | | | | PAGE E.1 | | | | | | E3901.2.1 SPACING. | | | RECEPTACLES SHALL BE INSTALLED SO THAT NO POINT | | | MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL | | | SPACE | | | IS MORE THAN 6 FEET (1829 MM), FROM A RECEPTACLE | | | OUTLET. | | | | | | NEC 210.52(A)(1)&(2) OUTLET SPACING, IT APPEARS SOME | | | POINTS ALONG THE WALL EXCEED 6? FROM AN OUTLET. | | | | | | NEED RISER DIAGRAM AND LOAD CALCULATION INACCORDANCE | | | WITH THE CODES 215.5, 220. | | | | | | E3602.2 SERVICE LOAD. | | | THE MINIMUM LOAD FOR UNGROUNDED SERVICE CONDUCTORS AND | | | SERVICE DEVICES THAT SERVE 100 PERCENT | | | OF THE DWELLING UNIT LOAD SHALL BE COMPUTED IN | | | ACCORDANCE WITH TABLE E3602.2. UNGROUNDED SERVICE | | | CONDUCTORS AND SERVICE DEVICES THAT SERVE LESS THAN 100 | | | PERCENT OF THE DWELLING UNIT LOAD SHALL BE | | | COMPUTED AS REQUIRED FOR FEEDERS IN ACCORDANCE WITH | | | CHAPTER 37. | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-11 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-08-11 |
Time |
12:10 |
Sent To |
|
|
| Notes |
| 2017-08-11 12:12:54 | SIGNED AND SEALED PLANS SUBMITTED. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-08-11 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2017-07-28 |
Time |
16:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-07 |
Time |
12:58 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-15 |
Time |
14:27 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2017-05-26 |
Time |
18:35 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-05-01 |
Time |
11:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-05-24 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-05-24 |
Time |
15:15 |
Sent To |
|
|
| Notes |
| 2017-05-24 15:17:03 | NO AIR CONDITIONING WORK BEING DONE AT | | | THIS TIME HM. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-07-07 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-07 |
Time |
12:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-07 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2017-07-07 12:58:01 | PLUMBING AND IRRIGATION APPROVED 7/7/17 /GPJ |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-18 |
Time |
14:12 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-18 |
Time |
14:12 |
Sent To |
|
|
| Notes |
| 2017-05-18 15:01:03 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | IRRIGATION COMMENTS: 5/18/17 | | | | | | 1. BACKFLOW REQUIRED ON IRRIGATION SYSTEM SEPARATE | | | PERMIT REQUIRED FOR BACKFLOW. PER WPB CROSS CONNECTION | | | MANUAL PG.19 PAR. I | | | | | | 2. A RAIN SENSOR IS REQUIRED ON IRRIGATION CONTROLS. | | | PER FS 373.62 | | | | | | 3. SPAY HEADS SHALL BE A MIN OF 12IN" FROM STRUCTURE. | | | FBC PL 318.1 | | | | | | 4. SHOW LOCATION OF CONTROLS AND RAIN SENSOR. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-18 |
Time |
13:56 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-18 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2017-05-18 14:09:37 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: 5/18/17 | | | | | | 1. P-1 SHOW LOCATION OF NEW TANKLESS WATER HEATER. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 2. PROVIDE PLUMBING RISER FOR ALL NEW PIPING. PER WPB | | | AMEND TO FBC 107.3.5.3(11) | | | | | | 3. A PLUMBING SUB PERMIT IS REQUIRED TO BE SUBMITTED BY | | | A LICENSED PLUMBING CONTRACTOR OR THE HOME OWNER. PER | | | WPB AMEND TO FBC 105.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-08-11 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-08-11 |
Time |
11:51 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-08-11 |
Time |
09:20 |
Sent To |
B |
|
| Notes |
| 2017-08-07 11:08:42 | REVISED DRAWINGS SUBMITTED. JG. |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-06-28 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-06-28 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
njwira |
Date |
2017-05-30 |
Time |
15:24 |
Rev Time |
0.00 |
| Received By |
njwira |
Date |
2017-05-30 |
Time |
14:55 |
Sent To |
I |
|
| Notes |
|
|