| Plan Review Stops For Permit 17041336 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2018-05-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-01 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-05-01 |
Time |
12:15 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-28 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-27 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2018-03-28 08:07:10 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE, 5TH EDITION W/2010 WEST | | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | CHAPTER 1 ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE 2ND SET OF PLANS. | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-05-26 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-05-26 |
Time |
10:59 |
Sent To |
|
|
| Notes |
| 2017-05-26 16:43:28 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. RE-LOCATION OF KITCHEN ISLAND WILL REQUIRE SAW | | | CUTTING OF EXISTING SLAB. PROVIDE REPAIR DETAIL OF | | | SLAB. | | | 2. PROVIDE FRAMING DETAIL FOR INTERIOR WALLS. | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-04-25 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-04-25 |
Time |
16:17 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-04-25 |
Time |
16:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2018-03-12 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2018-03-12 |
Time |
08:39 |
Sent To |
|
|
| Notes |
| 2018-03-12 08:40:03 | NEED ADDITIONAL SET TO STAMP ONLY ONE SET OF PLANS | | | SUBMITTED JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-23 |
Time |
12:03 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-23 |
Time |
12:03 |
Sent To |
|
|
| Notes |
| 2017-05-23 12:13:47 | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | 1ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL | | | | | | NOT SURE WHAT YOUR SYBOLS MEAN PLEASE PLACE A SCHEDULE | | | OF SYMBOLS ON PLANS. | | | | | | NEED TO SHOW ALL WORK RELEATED TO THE KITCHEN REMODEL | | | INCLUDING A PANEL SCHEDULE | | | WHICH SHOWS THE BRANCH CIRCUITS AND SIZES ON THE | | | CIRCUITS. | | | | | | E3901.4.1 WALL COUNTERTOP SPACE. | | | A RECEPTACLE OUTLET SHALL BE INSTALLED AT EACH WALL | | | COUNTERTOP SPACE 12 INCHES | | | (305 MM) OR WIDER. RECEPTACLE OUTLETS SHALL BE | | | INSTALLED SO THAT NO POINT ALONG | | | THE WALL LINE IS MORE THAN 24 INCHES (610 MM), MEASURED | | | HORIZONTALLY FROM A | | | RECEPTACLE OUTLET IN THAT SPACE. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
N |
Date |
2018-04-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-21 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-21 |
Time |
10:34 |
Sent To |
|
|
| Notes |
| 2018-04-21 10:35:16 | GAS PLAN REVIEW | | | A GAS PLAN HAS NOT BEEN INCLUDED IN THIS SUBMITTAL | | | PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN PERFORMED AT | | | THIS TIME. A SEPARATE GAS PERMIT AND PLANS WILL BE | | | REQUIRED FOR A CONTRACTOR TO PERFORM THE RELATED WORK. | | | PROVIDE COMPLETE PLANS, APPLIANCE/ EQUIPMENT | | | SPECIFICATIONS AND GAS RISER THAT REFLECT THE ENTIRE | | | SCOPE OF GAS WORK TO BE DONE. WPB AMEND. TO FBC SEC. | | | 107.2.1. | | | | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER THE | | | FBC-R, SEC. G2404.3. | | | GAS APPLIANCES SHALL BE LISTED AND LABELED PER FBC-FUEL | | | GAS SEC. 301.3. | | | | | | A SEPARATE PERMIT AND PLANS IS REQUIRED FOR THE GAS | | | INSTALLATION OR MODIFICATION OF SYSTEM. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-03-17 |
Time |
11:58 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-03-17 |
Time |
11:58 |
Sent To |
|
|
| Notes |
| 2018-03-17 12:08:32 | GAS PLAN REVIEW, A GAS PLAN HAS NOT BEEN INCLUDED IN | | | THIS SUBMITTAL PACKAGE. A GAS PLAN REVIEW HAS NOT BEEN | | | PERFORMED AT THIS TIME. A SEPARATE GAS PERMIT AND PLANS | | | WILL BE REQUIRED FOR A CONTRACTOR TO PERFORM THE | | | RELATED WORK. PROVIDE COMPLETE PLANS AND GAS RISER THAT | | | REFLECTS THE ENTIRE SCOPE OF GAS WORK TO BE DONE. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | GAS PERMIT APPLICATION REQUIREMENTS | | | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | | IN THE CITY OF WEST PALM BEACH: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 9. SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | LUIS CRESPO | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6720 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-18 |
Time |
17:52 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-18 |
Time |
17:52 |
Sent To |
|
|
| Notes |
| 2017-05-18 17:53:36 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | GAS PERMIT APPLICATION REQUIREMENTS | | | | | | EFFECTIVE IMMEDIATELY THE FOLLOWING INFORMATION SHALL | | | BE SHOWN ON ALL GAS DRAWINGS SUBMITTED FOR PERMITTING | | | IN THE CITY OF WEST PALM BEACH: | | | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT CLEARLY SHOWS ALL | | | CUT SECTIONS OF PIPE AND CORRESPONDING LENGTHS PER | | | FBC-2014 FUEL GAS, SECS. 402.4.1, 402.4.2. | | | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING INSTALLED, ALL | | | PIPE SIZES, AND THE EHD NUMBER OF CORRUGATED STAINLESS | | | STEEL TUBING FOR EACH PIPE SIZE IF BEING USED. WPB | | | AMENDMENTS TO FBC SEC. 107.2.1. | | | | | | 3. TYPE OF GAS, (LP OR NATURAL). | | | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE TOTAL BTU LOAD ON | | | THE SYSTEM. REFER TO THE FBC-2014 FUEL GAS SECS. 401.8 | | | THRU 402.6.1 AND TABLES 402.4(1) THRU 402.4(37). | | | | | | 5. SHOW THE DISTANCE FROM THE POINT OF DELIVERY, | | | (METER), TO THE MOST REMOTE OUTLET IN THE BUILDING | | | AND/OR SYSTEM PER THE FBC-2014 FUEL GAS APPENDIX A ? | | | USE OF CAPACITY SECTION A.3.1(4) & 2014 FUEL GAS CODE | | | SEC. 402.4.1. | | | | | | 6. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) PER FBC-2014 | | | FUEL GAS SEC. 402.2. IF NATURAL GAS SPECIFY .5 PSI OR 2 | | | PSI. | | | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 9. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-05-01 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-05-01 |
Time |
14:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-04-11 |
Time |
15:17 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2018-03-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2018-03-28 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2018-03-02 |
Time |
09:46 |
Sent To |
I |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-05-26 |
Time |
16:40 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-05-01 |
Time |
13:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-25 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-04-25 |
Time |
06:25 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-04-23 |
Time |
16:03 |
Sent To |
|
|
| Notes |
| 2018-04-24 14:52:37 | MECHANICAL PASSED ON 3/27/18 NO MECHANICAL PLAN | | | SUBMITTED THIS TIME HM. | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2018-03-27 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2018-03-27 |
Time |
10:24 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2018-03-26 |
Time |
14:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-05-24 |
Time |
15:05 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-05-24 |
Time |
14:32 |
Sent To |
|
|
| Notes |
| 2017-05-24 15:05:54 | PLAN DENIED | | | PROVIDE MANUFACTURES SPECKS ON | | | KITCHEN HOOD PER SECTION M1503.4 | | | MAKEUP AIR REQUIRED.2014 RESIDENTIAL | | | CODE | | | | | | PLAN REVIEW BY HAROLD MOSER | | | [email protected] | | | OFFICE 561-805-6732 | | | FAX 561-805-6676 |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-04-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-21 |
Time |
10:34 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-21 |
Time |
10:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2018-03-17 |
|
|
Cont ID |
|
| Sent By |
lcrespo |
Date |
2018-03-17 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
lcrespo |
Date |
2018-03-17 |
Time |
11:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-18 |
Time |
17:47 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-18 |
Time |
16:29 |
Sent To |
|
|
| Notes |
| 2017-05-18 17:51:18 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: 5/18/17 DENIED | | | | | | 1. IT IS UNCLEAR WHAT PLUMBING IS BEING DONE PLEASE | | | PROVIDE CLEARER NOTE AND DRAWINGS. PER WPB AMEND TO FBC | | | 107.2.1 | | | I SUGGEST SETTING UP A MEETING TO GO OVER PLANS | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|