| Plan Review Stops For Permit 17041335 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-08-16 |
Time |
16:58 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-08-16 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-07-28 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-07-28 |
Time |
17:15 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-07-28 |
Time |
14:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-06-21 |
Time |
09:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-21 |
Time |
08:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-05-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-16 |
Time |
15:06 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-16 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-07-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-27 |
Time |
13:31 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-27 |
Time |
13:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-20 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-20 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2017-06-20 07:16:30 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS (2ND REVIEW): | | | | | | 1. PREVIOUS COMMENTS NOT ADDRESSED. SEVERAL LOCATIONS | | | DO NOT SHOW LIGHTING CONTROL, AND I DO NOT SEE ANY | | | RECEPTACLE CONTROL. PROVIODE CORRECTIONS. PREVIOUS | | | COMMENTS AS FOLLOWS: | | | C405.2 LIGHTING CONTROLS (MANDATORY). | | | LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS | | | SPECIFIED IN SECTIONS C405.2.1, C405.2.2, C405.2.3 AND | | | C405.2.4. | | | | | | C405.2.1 MANUAL LIGHTING CONTROLS. | | | ALL BUILDINGS SHALL INCLUDE MANUAL LIGHTING CONTROLS | | | THAT MEET THE REQUIREMENTS OF SECTIONS C405.2.1.1 AND | | | C405.2.1.2. | | | | | | C405.2.1.1 INTERIOR LIGHTING CONTROLS. | | | EACH AREA ENCLOSED BY WALLS OR FLOOR-TO-CEILING | | | PARTITIONS SHALL HAVE AT LEAST ONE MANUAL CONTROL FOR | | | THE LIGHTING SERVING THAT AREA. | | | THE REQUIRED CONTROLS SHALL BE LOCATED WITHIN THE AREA | | | SERVED BY THE CONTROLS OR BE A REMOTE SWITCH THAT | | | IDENTIFIES THE LIGHTS SERVED | | | AND INDICATES THEIR STATUS. | | | | | | | | | C405.2.2.2 OCCUPANCY SENSORS. | | | OCCUPANCY SENSORS SHALL BE INSTALLED IN ALL CLASSROOMS, | | | CONFERENCE/MEETING ROOMS, EMPLOYEE LUNCH AND BREAK | | | ROOMS, PRIVATE | | | OFFICES, RESTROOMS, STORAGE ROOMS AND JANITORIAL | | | CLOSETS, AND OTHER SPACES 300 SQUARE FEET (28 M2) OR | | | LESS ENCLOSED BY FLOOR-TO-CEILING | | | HEIGHT PARTITIONS. THESE AUTOMATIC CONTROL DEVICES | | | SHALL BE INSTALLED TO AUTOMATICALLY TURN OFF LIGHTS | | | WITHIN 30 MINUTES OF ALL OCCUPANTS | | | LEAVING THE SPACE, AND SHALL EITHER BE MANUAL ON OR | | | SHALL BE CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING | | | ON TO NOT MORE THAN 50 PERCENT POWER. | | | | | | | | | ASHRAE 90.1, 8.4.2 OUTLET CONTROL | | | 8.4.2 AUTOMATIC RECEPTACLE CONTROL. | | | AT LEAST 50% OF ALL 125-VOLT, 15-AMP AND 20-AMP | | | RECEPTACLES, INCLUDING THOSE IN MODULAR PARTITIONS, | | | INSTALLED IN THESE SPACES: | | | A. PRIVATE OFFICES | | | B. OPEN OFFICES | | | C. COMPUTER CLASSROOMS SHALL BE CONTROLLED BY AN | | | AUTOMATIC CONTROL DEVICE THAT SHALL USE: | | | A) A SCHEDULED BASIS WITH TIME-OF-DAY OPERATED | | | PROGRAMMABLE CONTROL DEVICE ? | | | FOR NO MORE THAN 25,000 FT2 AND NO MORE THAN ONE FLOOR | | | PER DEVICE, OR | | | B) AN OCCUPANT SENSOR THAT TURNS RECEPTACLES OFF WITHIN | | | 30 MINUTES OF ROOM | | | BEING VACATED, OR | | | C) A SIGNAL FROM ANOTHER CONTROL OR ALARM THAT SIGNALS | | | THE ROOM IS UNOCCUPIED. | | | EXCEPTIONS: | | | A) RECEPTACLES FOR EQUIPMENT FOR 24-HOUR OPERATION. | | | B) SPACES WHERE AUTOMATIC SHUTOFF WOULD ENDANGER LIFE | | | SAFETY OR SECURITY. | | | | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-18 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-18 |
Time |
07:24 |
Sent To |
|
|
| Notes |
| 2017-05-18 07:57:48 | | | | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | C405.2 LIGHTING CONTROLS (MANDATORY). | | | LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS | | | SPECIFIED IN SECTIONS C405.2.1, C405.2.2, C405.2.3 AND | | | C405.2.4. | | | | | | C405.2.1 MANUAL LIGHTING CONTROLS. | | | ALL BUILDINGS SHALL INCLUDE MANUAL LIGHTING CONTROLS | | | THAT MEET THE REQUIREMENTS OF SECTIONS C405.2.1.1 AND | | | C405.2.1.2. | | | | | | C405.2.1.1 INTERIOR LIGHTING CONTROLS. | | | EACH AREA ENCLOSED BY WALLS OR FLOOR-TO-CEILING | | | PARTITIONS SHALL HAVE AT LEAST ONE MANUAL CONTROL FOR | | | THE LIGHTING SERVING THAT AREA. | | | THE REQUIRED CONTROLS SHALL BE LOCATED WITHIN THE AREA | | | SERVED BY THE CONTROLS OR BE A REMOTE SWITCH THAT | | | IDENTIFIES THE LIGHTS SERVED | | | AND INDICATES THEIR STATUS. | | | | | | | | | C405.2.2.2 OCCUPANCY SENSORS. | | | OCCUPANCY SENSORS SHALL BE INSTALLED IN ALL CLASSROOMS, | | | CONFERENCE/MEETING ROOMS, EMPLOYEE LUNCH AND BREAK | | | ROOMS, PRIVATE | | | OFFICES, RESTROOMS, STORAGE ROOMS AND JANITORIAL | | | CLOSETS, AND OTHER SPACES 300 SQUARE FEET (28 M2) OR | | | LESS ENCLOSED BY FLOOR-TO-CEILING | | | HEIGHT PARTITIONS. THESE AUTOMATIC CONTROL DEVICES | | | SHALL BE INSTALLED TO AUTOMATICALLY TURN OFF LIGHTS | | | WITHIN 30 MINUTES OF ALL OCCUPANTS | | | LEAVING THE SPACE, AND SHALL EITHER BE MANUAL ON OR | | | SHALL BE CONTROLLED TO AUTOMATICALLY TURN THE LIGHTING | | | ON TO NOT MORE THAN 50 PERCENT POWER. | | | | | | | | | ASHRAE 90.1, 8.4.2 OUTLET CONTROL | | | 8.4.2 AUTOMATIC RECEPTACLE CONTROL. | | | AT LEAST 50% OF ALL 125-VOLT, 15-AMP AND 20-AMP | | | RECEPTACLES, INCLUDING THOSE IN MODULAR PARTITIONS, | | | INSTALLED IN THESE SPACES: | | | A. PRIVATE OFFICES | | | B. OPEN OFFICES | | | C. COMPUTER CLASSROOMS SHALL BE CONTROLLED BY AN | | | AUTOMATIC CONTROL DEVICE THAT SHALL USE: | | | A) A SCHEDULED BASIS WITH TIME-OF-DAY OPERATED | | | PROGRAMMABLE CONTROL DEVICE ? | | | FOR NO MORE THAN 25,000 FT2 AND NO MORE THAN ONE FLOOR | | | PER DEVICE, OR | | | B) AN OCCUPANT SENSOR THAT TURNS RECEPTACLES OFF WITHIN | | | 30 MINUTES OF ROOM | | | BEING VACATED, OR | | | C) A SIGNAL FROM ANOTHER CONTROL OR ALARM THAT SIGNALS | | | THE ROOM IS UNOCCUPIED. | | | EXCEPTIONS: | | | A) RECEPTACLES FOR EQUIPMENT FOR 24-HOUR OPERATION. | | | B) SPACES WHERE AUTOMATIC SHUTOFF WOULD ENDANGER LIFE | | | SAFETY OR SECURITY. | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-07-21 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-07-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-07-21 |
Time |
12:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-06-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-06-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-06-12 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-03 |
Time |
16:20 |
Sent To |
|
|
| Notes |
| 2017-05-04 11:20:53 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) ALL FIRE ALARM WORK SHALL DE DONE UNDER SEPARATE | | | SHOP DRAWINGS BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-08 |
Time |
13:18 |
Sent To |
|
|
| Notes |
| 2017-08-09 13:18:15 | RESUB ROUTED TO GJOHNSON |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-07-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-07-17 |
Time |
09:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-07 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-18 |
Time |
08:00 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-04-28 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-05-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-16 |
Time |
14:23 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-16 |
Time |
13:53 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-07-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-26 |
Time |
07:57 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-25 |
Time |
17:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-20 |
Time |
13:00 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-20 |
Time |
13:00 |
Sent To |
|
|
| Notes |
| 2017-06-20 13:03:56 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17041335 | | | 6/20/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE COMMENTS FROM THE FIRST REVIEW WERE NOT | | | ADDRESSED. I HAVE REPRINTED THEM BELOW- PLEASE COMPLY. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTAL. | | | | | | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | | PERMIT #17041335 | | | 5/9/17 | | | | | | 1) REFER TO SECTIONS 809.1 & 809.2 FBC-14 EXISTING | | | BUILDING CODE AND PROVIDE MINIMUM VENTILATION | | | CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE 403.3 | | | FBC-14 MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES | | | THE REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 2) THE PLANS DO NOT CLEARLY SHOW HOW OUTSIDE AIR IS | | | BEING PROVIDED TO THE FAN COIL UNITS. SOME UNITS HAVE | | | O/A DUCTS IN THEIR VICINITIES BUT THERE ARE MANY OTHERS | | | THAT DO NOT SHOW ANY O/A DUCT CONNECTIONS OR DUCTS IN | | | THEIR VICINITIES I.E. WSHP- 24, 231, 232, 363, & 481. | | | | | | 3) O/A DAMPERS THAT WILL AUTOMATICALLY SHUT WHEN THE | | | SYSTEMS ARE NOT OPERATING ARE REQUIRED PER SECTION | | | C403.2.4.4 FBC-14 ENERGY CONSERVATION. | | | | | | 4) REFER TO SECTION C403.2.7.5 AND INDICATE HOW THE AIR | | | DISTRIBUTION SYSTEM WAS SIZED AND DESIGNED. | | | | | | 5) PROVIDE A FIRE DAMPER INSTALLATION DETAIL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-09 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-09 |
Time |
12:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-09 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2017-05-09 12:24:50 | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | | PERMIT #17041335 | | | 5/9/17 | | | | | | 1) REFER TO SECTIONS 809.1 & 809.2 FBC-14 EXISTING | | | BUILDING CODE AND PROVIDE MINIMUM VENTILATION | | | CALCULATIONS FOR ALL ROOMS AND SPACES PER TABLE 403.3 | | | FBC-14 MECHANICAL. PROVIDE A SCHEDULE THAT INDICATES | | | THE REQUIRED AND PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 2) THE PLANS DO NOT CLEARLY SHOW HOW OUTSIDE AIR IS | | | BEING PROVIDED TO THE FAN COIL UNITS. SOME UNITS HAVE | | | O/A DUCTS IN THEIR VICINITIES BUT THERE ARE MANY OTHERS | | | THAT DO NOT SHOW ANY O/A DUCT CONNECTIONS OR DUCTS IN | | | THEIR VICINITIES I.E. WSHP- 24, 231, 232, 363, & 481. | | | | | | 3) O/A DAMPERS THAT WILL AUTOMATICALLY SHUT WHEN THE | | | SYSTEMS ARE NOT OPERATING ARE REQUIRED PER SECTION | | | C403.2.4.4 FBC-14 ENERGY CONSERVATION. | | | | | | 4) REFER TO SECTION C403.2.7.5 AND INDICATE HOW THE AIR | | | DISTRIBUTION SYSTEM WAS SIZED AND DESIGNED. | | | | | | 5) PROVIDE A FIRE DAMPER INSTALLATION DETAIL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-16 |
Time |
12:32 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-16 |
Time |
12:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2017-07-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-26 |
Time |
13:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-26 |
Time |
10:57 |
Sent To |
|
|
| Notes |
| 2017-07-26 14:30:17 | 13RD REVIEW: FBC 2014 5TH EDITION | | | | | | PREVIOUS COMMENTS: | | | NOT COMPLIED 3RD REQUEST 1) SUBMIT FIRE STOP DETAILS | | | FOR THE PLUMBING PIPE PENETRATIONS THROUGH THE FLOORS | | | PER FBC SEC.711.5 & 714.4.1. | | | | | | NOT COMPLIED 3RD 6) SHT. P201 - PLBG. NOTES #2 - | | | TEMPERED WATER IS REQUIRED AT THE LAVATORY PER 2014 | | | FBC- PLUMBING SEC.416.5, 607.1. | | | | | | NOT COMPLIED 3RD 7) WATER HAMMER ARRESTORS ARE REQD. | | | WHERE QUICK -CLOSING VALVES ARE UTILIZED. 2014 | | | FBC-PLUMBING SEC.604.9. | | | SHOW COMPLIANCE AT DISHWASHER, ICE MAKER AND | | | REFRIGERATOR. | | | | | | NEW COMMENTS: | | | | | | 1. SHOW COMPLIANCE WITH FBC ACC 604.5.2 REAR WALL. | | | THE REAR WALL GRAB BAR SHALL BE 36 INCHES (915 MM) LONG | | | MINIMUM AND EXTEND FROM THE CENTERLINE OF THE WATER | | | CLOSET 12 INCHES (305 MM) MINIMUM ON ONE SIDE AND 24 | | | INCHES (610 MM) MINIMUM ON THE OTHER SIDE. | | | | | | 2. SHOW COMPLIANCE WITH FBC ACC 603.3 MIRRORS. | | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | | FLOOR OR GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES | | | OR COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE | | | OF THE REFLECTING SURFACE 35 INCHES (890 MM) MAXIMUM | | | ABOVE THE FINISH FLOOR OR GROUND. | | | | | | 3. SHOW COMPLIANCE WITH FBC ACC 604.4 SEATS. | | | THE SEAT HEIGHT OF A WATER CLOSET ABOVE THE FINISH | | | FLOOR SHALL BE 17 INCHES (430 MM) MINIMUM AND 19 INCHES | | | (485 MM) MAXIMUM MEASURED TO THE TOP OF THE SEAT. SEATS | | | SHALL NOT BE SPRUNG TO RETURN TO A LIFTED POSITION. | | | | | | 4. THE BRANCH DRAIN FOR BREAKROOM 233 SHALL CONNECT TO | | | BUILDING DRAIN DOWNSTREAM OF THE BATHE ROOM GROUP. PER | | | FBC PL 912.1 | | | | | | 5. THE HORIZONTAL DRY VENT FOR THE WC IS NOT PERMITTED. | | | PER FBC ACC 905.3 AND 905.4 | | | | | | 6. P-201 NOTE ON RESTROOM PIPING REF. SHOCK ARRESTOR | | | SEE DETAIL #6 P-401 , THERE IS NO DETAIL 6 ON P-401 | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 7. SHT. P-401 ENLARGED PLAN KEY NOTES #1 PROVIDE | | | CALCULATIONS AND MANUFACTURE SPECS FOR GREASE | | | INTERCEPTOR. PER WPB AMEND TO FBC 107.2.1 | | | | | | 8. SHT. P-401 ENLARGED PLAN KEY NOTES #1 GREASE | | | INTERCEPTOR NOT SHOWN ON RISER NETHER IS THE FD-1 | | | PLEASE CLARIFY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 9. SHT. P-401 ENLARGED PLAN KEY NOTES # 3 STATES A 4" | | | SANITARY LINE THE RISER SHOWS A 3" PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-16 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-16 |
Time |
13:14 |
Sent To |
|
|
| Notes |
| 2017-06-16 15:20:13 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PREVIOUS COMMENTS: | | | NOT COMPLIED1) SUBMIT FIRE SAFING DETAILS FOR THE | | | PLUMBING PIPE PENETRATIONS THROUGH THE FLOORS PER FBC | | | SEC.711.5 & 714.4.1. | | | | | | NOT COMPLIED 3) THE INSTALLATION OF THE GRAB BARS IN | | | THE ACCESSIBLE TOILET ROOM SHALL COMPLY WITH 2014 | | | FBC-ACCESS. SECS.604.5 & 609.4. | | | | | | NOT COMPLIED 6) SHT. P201 - PLBG. NOTES #2 - TEMPERED | | | WATER IS REQUIRED AT THE LAVATORY PER 2014 FBC- | | | PLUMBING SEC.416.5, 607.1. | | | | | | NOT COMPLIED 7) WATER HAMMER ARRESTORS ARE REQD. WHERE | | | QUICK -CLOSING VALVES ARE UTILIZED. 2014 FBC-PLUMBING | | | SEC.604.9. | | | | | | NOT COMPLIED 8) THE PLANS SHOW COLD WATER TO THE | | | DISHWASHER. CLARIFY. SUBMIT SPECIFICATIONS FOR THE | | | DISHWASHER IF IT IS TO BE SUPPLIED WITH COLD WATER. | | | | | | NOT COMPLIED 9) SUBMIT A SANITARY AND WATER RISER FOR | | | ALL THE CHANGES BEING MADE TO THE PLUMBING SYSTEM. WPB | | | AMEND. TO FBC SEC. 107.3.5.1.3. | | | | | | NOT COMPLIED 10) THE LOCATION OF THE TOILET PAPER | | | DISPENSER IN THE ACCESSIBLE TOILET ROOM SHALL COMPLY | | | WITH 2014 FBC - ACCESS. SEC.604.7. | | | | | | | | | | | | | | | | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
tklarge |
Date |
2017-05-17 |
Time |
13:38 |
Rev Time |
0.00 |
| Received By |
tklarge |
Date |
2017-05-12 |
Time |
04:25 |
Sent To |
|
|
| Notes |
| 2017-05-17 10:43:24 | 1) SUBMIT FIRE SAFING DETAILS FOR THE PLUMBING PIPE | | | PENETRATIONS THROUGH THE FLOORS PER FBC SEC.711.5 & | | | 714.4.1. | | | 2) SHT. A300, DETAIL A16 - SHOW THE LENGTH AND WIDTH | | | DIMENSIONS OF THE CLEAR FLOOR SPACE FOR THE WATER | | | CLOSET PER 2014 FBC - ACCESS SEC.604.3. | | | 3) THE INSTALLATION OF THE GRAB BARS IN THE ACCESSIBLE | | | TOILET ROOM SHALL COMPLY WITH 2014 FBC-ACCESS. | | | SECS.604.5 & 609.4. | | | 4) SHT. A300 - DETAIL A16 - SHOW THE CLEAR INSIDE | | | DIMENSIONS ( LENGTH X WIDTH) OF THE TOILET ROOM. THE | | | MINIMUM WIDTH SHALL BE 85 INCHES. 86 INCHES ALLOWS FOR | | | TOLERANCE.2014 FBC-ACCESS. SEC.604.3, 604.3.2. | | | 5) THE MINIMUM CLEARANCE UNDER A LAVATORY SHALL BE 27 | | | INCHES PER 2014 FBC-ACCESS. SEC. 306.3.1.DETAIL M1 ON | | | A300 IS FOR A SINK. SUBMIT A DETAIL FOR THE LAVATORY. | | | 6) SHT. P201 - PLBG. NOTES #2 - TEMPERED WATER IS | | | REQUIRED AT THE LAVATORY PER 2014 FBC- PLUMBING | | | SEC.416.5, 607.1. | | | 7) WATER HAMMER ARRESTORS ARE REQD. WHERE QUICK | | | -CLOSING VALVES ARE UTILIZED. 2014 FBC-PLUMBING | | | SEC.604.9. | | | 8) THE PLANS SHOW COLD WATER TO THE DISHWASHER. | | | CLARIFY. SUBMIT SPECIFICATIONS FOR THE DISHWASHER IF IT | | | IS TO BE SUPPLIED WITH COLD WATER. | | | 9) SUBMIT A SANITARY AND WATER RISER FOR ALL THE | | | CHANGES BEING MADE TO THE PLUMBING SYSTEM. WPB AMEND. | | | TO FBC SEC. 107.3.5.1.3. | | | 10) THE LOCATION OF THE TOILET PAPER DISPENSER IN THE | | | ACCESSIBLE TOILET ROOM SHALL COMPLY WITH 2014 FBC - | | | ACCESS. SEC.604.7. | | | | | | TIM LARGE | | | CHIEF PLUMBING INSPECTOR | | | PLUMBING PLAN REVIEW | | | 561-805-6692 | | | [email protected] | | | |
|
|