Plan Review Details - Permit 17041276
| Plan Review Stops For Permit 17041276 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
P |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-05-15 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-05-15 |
Time |
16:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-04-16 |
|
|
Cont ID |
|
| Sent By |
jgomez |
Date |
2018-04-13 |
Time |
18:59 |
Rev Time |
0.00 |
| Received By |
jgomez |
Date |
2018-04-11 |
Time |
13:06 |
Sent To |
|
|
| Notes |
| 2018-04-11 12:30:15 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17041276 | | | ADD: 1626 OKEECHOBEE RD. | | | CONT: ERETZOR CONSTRUCTION LLC | | | TEL: 954-937-7041 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 3RD REVIEW | | | DATE: WED. APRIL 11/2018 | | | ACTION: DENIED | | | | | | 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B). | | | | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | 1) COVERSHEET A-1: | | | 1A) COMPLIED. LEVEL III ALTERATION LABEL WAS REMOVED. | | | | | | 1B) THIRD REQUEST: | | | (1)SEMI-COMPLIED. THE OCCUPANCY AND USE OF THE PROPOSED | | | STRUCTURE IS NOT CLEAR AND A THOROUGH REVIEW CAN NOT BE | | | ACCOMPLISHED. (SEC. 301.1 FBC-BUILDING). THE BUILDING | | | CLASSIFICATION INFORMATION DATED 10-6-17 CALLS FOR R-2 | | | BOARDING HOUSE, NONTRANSIENT, UP TO 90 DAYS AND WITH A | | | MAXIMUM OF 16 RESIDENTS. R-2 OCCUPANCIES ARE PRIMARILY | | | PERMANENT IN NATURE AND THE BOARDING HOUSES ARE FOR | | | MORE THAN 16 OCCUPANTS. BASED ON THE PREVIOUS PLAN | | | REVIEWER'S COMMENTS, IT IS MY UNDERSTANDING THAT THIS | | | BUILDING MAY BE USED EITHER AS AN ALCOHOL AND OR DRUG | | | CENTER OR GROUP HOME AND BASED ON THE NUMBER OF PEOPLE | | | IT FALLS INTO R-4 GROUP. REVISE AS REQUIRED AND CLEARLY | | | IDENTIFY WHICH R-4 CATEGORY IS THE BUILDING GOING TO BE | | | USED FOR. | | | | | | (2)DRAWING INDEX DATED 10-9-17 DOESN'T LIST ALL THE | | | DRAWINGS SUBMITTED. REVISE AS REQUIRED TO MATCH. (SEC. | | | 107.2.1 CITY AMENDMENTS). | | | | | | PREVIOUS COMMENT: | | | 2ND REQUEST. THE DESIGNER OF RECORD HAS NOT PROVIDED A | | | CODE ANALYSIS, PROVIDING THE OCCUPANCY TYPE, USAGE, | | | (ALCOHOL AND OR DRUG CENTER, GROUP HOME), THE TYPE OF | | | MINIMUM CONSTRUCTION REQUIRED, OR IF FIRE SPRINKLERED. | | | NOTE FIRE SPRINKLER PLANS FOR R13 SYSTEM SUBMITTED. | | | | | | | | | 2. STILL NO CLARIFIED. SEE RESPONSE TO ITEM #1B) ABOVE. | | | REGARDING THE ISSUE ON SHEET A-17 & A-18 STATING THAT | | | THIS IS A PRIVATE FACILITY NOT OPEN TO THE GENERAL | | | PUBLIC OR RENTED OUT TO THE GENERAL PUBLIC. THE | | | ARCHITECT'S RESPONSE IS THAT THIS IS A "BOARDING | | | HOUSE". THIS NEEDS TO BE COORDINATED WITH ITEM #1B) | | | ABOVE. THE USE AND OCCUPANCY STILL NO CLEAR AND NEED TO | | | READ THE DEFINITION OF "BOARDING HOUSE" ON CHAPTER 2 OF | | | FBC. THE PROPOSED USE AND OCCUPANCY AND THE PRIVATE | | | FACILITY ISSUE NEED TO BE CLEARLY DEFINED FOR PROPER | | | PLAN REVIEW. | | | ALSO, NOTE ON SHEET A-17 AND A-18 DON'T MATCH. ONE | | | STATES FAIR HOUSING ACT AND THE OTHER STATES ADAAG. | | | NEED TO COORDINATE AND MAKE SURE CORRECT SECTION IS | | | CITED. | | | | | | PREVIOUS COMMENT: | | | OCCUPANCY TYPE 301.1 SHORT TERM FACILITY OR LONG TERM | | | FACILITY. PLEASE NOTE ON THE COVERSHEET THERE IS A NOTE | | | STATING THIS IS A SHORT TERM FACILITY. WHEN DEFINING | | | SHORT TERM THE BUILDING CODE USES 30 DAYS OR LESS FOR | | | SHORT TERM (TRANSIENT), LONGER STAYS ARE | | | (NON-TRANSIENT). IT APPEARS THIS USAGE IS MORE OF A R4 | | | FACILITY AN ALCOHOL AND OR DRUG REHAB CENTER WITH | | | CONGREGATE CARE FACILITIES, (A BUILDING OR PART THERE | | | OF THAT CONTAINS SLEEPING UNITS WHERE THE RESIDENTS | | | SHARE BATHROOMS AND OR KITCHEN FACILITIES. THE OTHER | | | ISSUE IS WITH THE UNITS CONTAINING 2 BEDROOMS AND 2 | | | OCCUPANTS PER BEDROOM AND SHARED BATHROOMS AND OR | | | KITCHEN FACILITIES THE UNIT ALSO RESEMBLES DORMITORIES! | | | PLEASE DECLARE OCCUPANCY AND USAGE. 2014 FBC-B 302.1 | | | CLASSIFICATION. | | | | | | THE OTHER ISSUE IS THE NOTE FOUND ON SHEET A-17 & A-18 | | | THAT THIS BUILDING IS A PRIVATE FACILITY NOT OPEN TO | | | THE GENERAL PUBLIC OR RENTED OUT TO THE GENERAL PUBLIC. | | | HOW DOES ONE END UP AS A TENANT AT THIS ESTABLISHMENT. | | | THE DESIGNER OF RECORD WITH NOT DEFINING THE OCCUPANCY | | | TYPE AND USAGE WE CAN NOT DEFINE WHICH THE DESIGNER | | | MUST DESIGN TOO, FAIR HOUSING OR THE 2014 | | | FBC-ACCESSIBILITY CODE, NOT ADAAG. | | | NOTE THE FLORIDA ACCESSIBILITY CODE IS BLESSED BY THE | | | DEPARTMENT OF JUSTICE, AND A MORE RESTRICTIVE CODE. | | | IT IS TRUE YOU MAY NOT REQUIRE AN ELEVATOR BUT DOES NOT | | | RELIEVE THE DESIGNER FROM THE DUTY OF VERTICAL | | | ACCESSIBILITY, ON THE OTHER HAND IF THIS FACILITY IS | | | DETERMINED TO FALL UNDER THE GUIDELINES OF FAIR HOUSING | | | THEN THE 2014 FBC FAIR HOUSING ACCESSIBILITY GUIDELINES | | | WOULD APPLY. PLEASE DECLARE OCCUPANCY AND USAGE. 2014 | | | FBC-B 302.1 CLASSIFICATION. | | | | | | | | | 3) COMPLIED | | | | | | 4)SEMI-COMPLIED. MISSING DETAILS AND SPECIFICATIONS FOR | | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS. | | | | | | PREVIOUS COMMENT: | | | FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL INCLUDE | | | THE FOLLOWING COMPONENTS: | | | FIRE-RESISTANT SEPARATIONS | | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | | FIRE BLOCKING AND DRAFTSTOPPING AND CALCULATED FIRE | | | RESISTANCE | | | | | | 5.COMPLIED. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: | | | SCHEMATIC FIRE SPRINKLERS | | | STANDPIPES | | | PRE-ENGINEERED SYSTEMS | | | | | | 6) COMPLIED. LIFE SAFETY SYSTEMS SHALL BE DETERMINED | | | AND SHALL INCLUDE THE FOLLOWING REQUIREMENTS: | | | OCCUPANT LOAD AND EGRESS CAPACITIES | | | | | | 7. SEMI-COMPLIED. SECOND FLOOR LIFE SAFETY PLAN IS | | | INCOMPLETE. MISSING SMOKE DETECTORS, FIRE RATED WALLS, | | | ETC. PROVIDE COMPLETE LIFE SAFETY PLAN WITH ALL THE | | | REQUIRED INFORMATION. | | | | | | PREVIOUS COMMENT: | | | OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | NO LIFE SAFETY SHEET!!!!!!! PROVIDE THE AMOUNT OF BEDS | | | PER SLEEPING ROOM | | | OCCUPANCY LOADS | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | DOORS | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | SPECIFIC OCCUPANCY REQUIREMENTS | | | | | | | | | 10- SEMI COMPLIED. CLEARLY SHOW THE ACCESSIBLE ROUTE. | | | PROVIDE DETAILS ANS SPECIFICATIONS FOR KITCHEN, | | | LAUNDRY, CASUAL ROOM AND GREAT ROOM TOILET FACILITIES. | | | CLARIFY/REVISE THE COUNTER HEIGHT SHOWN ON THE | | | ACCESSIBLE KITCHEN DETAIL ON SHEET A-17 AND HEIGHT | | | SHOWN ON THE FIRST FLOOR PLAN. REVISE STAIR SECTION | | | 1/A11 SHOWN ON SHEET A15.2. NEED TO COMPLY WITH FBC | | | ACCESSIBILITY SEC. 505.10.2 FOR EXTENSION AT TOP OF | | | STAIRS AND SEC. 505.10.3 FOR EXTENSION AT BOTTOM OF | | | STAIRS. SEE DETAILS SUBMITTED AND SEC. 505.10.2 AND | | | 505.10.3 AND PROVIDE CORRECT DIMENSIONS OF THE | | | EXTENSION AT TOP AND BOTTOM. ALSO, ALL PLANS NEED TO | | | SHOW THE LOCATION OF THE STAIRS EXTENSIONS. | | | | | | PREVIOUS COMMENT: | | | FL. ACCESSIBILITY CODE OR FAIR HOUSING, VERTICAL | | | ACCESSIBILITY? | | | ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE FOLLOWING: | | | SITE REQUIREMENTS | | | ACCESSIBLE ROUTE | | | VERTICAL ACCESSIBILITY | | | TOILET AND BATHING FACILITIES | | | DRINKING FOUNTAINS | | | EQUIPMENT | | | SPECIAL OCCUPANCY REQUIREMENTS | | | FAIR HOUSING REQUIREMENTS | | | | | | 11. PROVIDE FINISH SCHEDULE. | | | | | | PREVIOUS COMMENT: | | | NO FINISH SCHEDULE!!!!INTERIOR REQUIREMENTS SHALL | | | INCLUDE THE FOLLOWING: | | | INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT) | | | LIGHT AND VENTILATION | | | SANITATION | | | | | | 12. NO REQUIRED. | | | | | | 1C) THERE IS A HANDWRITTEN NOTE ON SHEET A-1 STATING | | | THAT THIS BUILDING IS CONSIDERED ONE BUILDING. IT LOOKS | | | LIKE THE HANDWRITTEN IS NOT DONE BY THE ARCHITECT OF | | | RECORD. THE INITIALS ARE NOT THE SAME AS THE ARCHITECT | | | OF RECORD. ARCHITECT OF RECORD TO PROVIDE INFORMATION | | | ON THE FINAL DRAWING SUBMITTED FOR PUBLIC RECORDS. | | | (CHAPTER 481 F.S.). HANDWRITTEN INFORMATION BY OTHER | | | PERSON OTHER THAN THE ARCHITECT OF RECORD NOT ALLOWED. | | | BESIDES, HANDWRITTEN INFORMATION MAY CREATE CONFLICTS | | | DOWN THE ROAD BECAUSE ANY REVISIONS WILL NOT SHOW THE | | | HANDWRITTEN INFORMATION. | | | | | | PREVIOUS COMMENT: | | | 2ND REQUEST. THE PLANS DO NOT INDICATE IF THE CONCEPT | | | FOR THIS PROJECT TO BE CONSIDERED 1 BUILDING (TOTAL | | | SQUARE FOOT, FOOT PRINT OR IF THEY ARE TRYING TO COMPLY | | | UNDER THE BUILDINGS ON THE SAME LOT, SECTION 503.1.2. | | | | | | 1D) COMPLIED. FIRE SPRINKLER PLANS. | | | | | | 1E) COMPLIED. | | | | | | 2) COMPLIED. | | | | | | 3) COMPLIED. | | | | | | 4) THIRD REQUEST. ART IN PUBLIC PLACES. THE CITY OF | | | WEST PALM BEACH ART IN PUBLIC PLACES ORDINANCE | | | REQUIREMENT THAT APPLIES TO ANY REMODEL OR NEW | | | CONSTRUCTION PROJECT FOR WHICH THE PERMIT APPLICATION | | | WAS SUBMITTED AFTER 6/29/14, AND THE TOTAL PROJECT | | | CONSTRUCTION COSTS ARE EQUAL TO OR GREATER THAN | | | $750,000 WILL NEED TO COMPLY WITH THIS ORDINANCE. PER | | | CITY OF WEST PALM BEACH ORDINANCE NO. 4504-14, AND CITY | | | OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE V, ART | | | IN PUBLIC PLACES, SECTION 78-123(A) AND SECTION | | | 78-126(A), THE ART ASSESSMENT IS 1% OF THE TOTAL | | | PROJECT CONSTRUCTION COST. | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | FOR CONTACT INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | | 822-1515 E-MAIL: [email protected] | | | | | | 5) COMPLIED. | | | | | | 6) NEED TO COORDINATE WITH ITEM #1B ABOVE. | | | | | | PREVIOUS REQUEST: | | | 2ND REQUEST. PLEASE SHOW HOW COMPLIANCE WITH FBC-B | | | SECTION 420 IS ACHIEVED. PLEASE REVIEW 2014 FBC-B 310.6 | | | GROUP R-4 OCCUPANCIES SHALL MEET THE REQUIREMENTS FOR | | | R-3 CONSTRUCTION EXCEPT, AS OTHERWISE PROVIDED IN THIS | | | CODE. | | | 420.1 OCCUPANCIES IN GROUPS I-1, R-1, R-2 AND R-3 SHALL | | | COMPLY WITH THE PROVISIONS OF SECTIONS 420.1 THROUGH | | | 420.5 AND OTHER APPLICABLE PROVISIONS OF THIS CODE. | | | | | | 6A) COMPLIED. | | | | | | 6B) COMPLIED. | | | | | | 6C) COMPLIED. [F] 420.4 AUTOMATIC SPRINKLER SYSTEM. | | | GROUP R OCCUPANCIES SHALL BE EQUIPPED THROUGHOUT WITH | | | AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | | SECTION 903.2.8. GROUP I-1 OCCUPANCIES SHALL BE | | | EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM | | | IN ACCORDANCE WITH SECTION 903.2.6. QUICKRESPONSE OR | | | RESIDENTIAL AUTOMATIC SPRINKLERS SHALL BE INSTALLED IN | | | ACCORDANCE WITH SECTION 903.3.2. | | | | | | 6D) NEED TO COORDINATE WITH ITEM #1B ABOVE. | | | | | | PREVIOUS REQUEST: | | | [F] 420.5 SMOKE DETECTION AND FIRE ALARM SYSTEMS. FIRE | | | ALARM SYSTEMS AND SMOKE ALARMS SHALL BE PROVIDED IN | | | GROUP I-1, R-1 AND R-2 OCCUPANCIES IN ACCORDANCE WITH | | | SECTIONS 907.2.6, 907.2.8 AND 907.2.9, RESPECTIVELY. | | | SINGLE-OR MULTIPLE-STATION SMOKE ALARMS SHALL BE IN | | | ACCORDANCE WITH SECTION 907.2.11. | | | | | | 7A)COMPLIED. | | | | | | 7B) SEMI-COMPLIED. ARCHITECT OF RECORD TO PROVIDE | | | INFORMATION ON THE FINAL DRAWING SUBMITTED FOR PUBLIC | | | RECORDS. (CHAPTER 481 F.S.). HANDWRITTEN INFORMATION BY | | | OTHER PERSON OTHER THAN THE ARCHITECT OF RECORD NOT | | | ALLOWED. BESIDES, HANDWRITTEN INFORMATION MAY CREAT | | | CONFLICTS DOWN THE ROAD BECAUSE ANY REVISIONS WILL NOT | | | SHOW THE HANDWRITTEN INFORMATION. | | | | | | PREVIOUS COMMENT: | | | THE WIND PRESSURES PROVIDED ON SHEETS A8 & A9 DO NOT | | | INDICATE THEY ARE IN VULT. THE PRESSURES IN ALL OF THE | | | PRODUCT APPROVALS ARE VASD, PLEASE PROVIDE THE | | | PRESSURES IN VASD. ULTIMATE DESIGN WIND SPEED, VULT, | | | (3-SECOND GUST), MILES PER HOUR (KM/HR) AND NOMINAL | | | DESIGN WIND SPEED, VASD, AS DETERMINED IN ACCORDANCE | | | WITH SECTION 1609.3.1. | | | 1ST REVIEW. SHEET A8 & A9 SHOW PRESSURES FOR COMPONENTS | | | AND CLADDING, BUT THERE IS NO WIND DESIGN CRITERIA TO | | | KNOW IF THESE PRESSURES ARE ACCURATE. 2014 FBC-B | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 7.1. COMPLIED. | | | | | | 7.2. COMPLIED. | | | | | | 7.3. COMPLIED. | | | | | | 7.4. COMPLIED. | | | | | | 7.5. COMPLIED | | | | | | 8) SEMI-COMPLIED. THE HANDWRITTEN DESIGN PRESSURES | | | SHOWN ON THE EXTERIOR ELEVATIONS LOOK TO BE DONE FOR A | | | MEAN ROOF HEIGHT OF 20 FEET . THE MEAN ROOF HEIGHT FOR | | | THIS BUILDING IS ABOUT 25 FEET. REVISE AS REQUIRED OR | | | PROVIDE COMPLETE CALCULATIONS. ALSO, ARCHITECT OF | | | RECORD TO PROVIDE INFORMATION ON THE FINAL DRAWING | | | SUBMITTED FOR PUBLIC RECORDS. (CHAPTER 481 F.S.). | | | HANDWRITTEN INFORMATION BY OTHER PERSON OTHER THAN THE | | | ARCHITECT OF RECORD NOT ALLOWED. BESIDES, HANDWRITTEN | | | INFORMATION MAY CREATE CONFLICTS DOWN THE ROAD BECAUSE | | | ANY REVISIONS WILL NOT SHOW THE HANDWRITTEN | | | INFORMATION. ALL PRODUCT APPROVALS WILL BE REVIEWED | | | ONCE THE DESIGN PRESSURES ARE REVISED AND ARE ON THE | | | FINAL DRAWINGS. NOTE: TO HELP EXPEDITE THE REVIEW AND | | | PERMIT ISSUANCE ALL PRODUCT APPROVALS MAY BE | | | SUBMITTED/REVIEWED AFTER THE PERMIT ISSUED UNDER | | | DEFERRED SUBMITTALS. | | | | | | PREVIOUS COMMENT: | | | 2ND REQUEST, UNTIL THE WIND DESIGN PRESSURES ARE IN | | | DESIGN PRESSURES (VASD) THE PRODUCT APPROVALS SUBMITTED | | | CAN NOT BE CHECKED FOR CODE COMPLIANCE. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | VENTILATORS (NOTE: CHECK FLAT ROOF ASSEMBLY) | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL | | | 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | | | | 9) SEMI-COMPLIED. WILL BE REVIEWED ONCE DESIGN | | | PRESSURES ARE REVISED ON FINAL DRAWINGS. NOTE: TO HELP | | | EXPEDITE THE REVIEW AND PERMIT ISSUANCE ALL PRODUCT | | | APPROVALS MAY BE SUBMITTED/REVIEWED AFTER THE PERMIT | | | ISSUED UNDER DEFERRED SUBMITTALS. | | | | | | PREVIOUS COMMENT: | | | IDENTIFY GLAZING/ MULLIONS. FOR ALL PRODUCTS WITH | | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | | TYPE OF GLAZING, MULLION INFORMATION IF REQUIRED, | | | ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING | | | SIZE. 2014 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND | | | DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED | | | MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING | | | SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE | | | CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN | | | THE TESTS. | | | | | | 10) SEMI COMPLIED. SEE ITEM #10 ABOVE. | | | | | | 11) SEMI-COMPLIED. PLANS DON'T SHOW FINISH FLOORS. | | | UNABLE TO VERIFY FLOOR UNDERLAYMENT INFORMATION | | | SUBMITTED. INFORMATION SUBMITTED WILL BE REVIEWED WHEN | | | THE PROPOSED FINISH IS SPECIFIED. NEED TO CHECK FINISH | | | MATERIAL AND FLOOR ASSEMBLY MATCHES THE ONE THAT WAS | | | TESTED. NOTE: TO HELP EXPEDITE THE REVIEW AND PERMIT | | | ISSUANCE THIS INFORMATION MAY BE SUBMITTED/REVIEWED | | | AFTER THE PERMIT ISSUED UNDER DEFERRED SUBMITTALS. | | | | | | PREVIOUS COMMENT: | | | 2ND REQUEST. THE PLANS DO NOT INDICATE WHAT THE 2ND | | | FLOOR FINISHES WILL BE? PLEASE SHOW COMPLIANCE WITH: | | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | | LISTED UNDER EACH OF THE STANDARDS FOR A HAMBRO FLOOR | | | SYSTEM/ NO DROPPED CEILING: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | 11A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 11B) SEMI-COMPLIED. THERE ARE NO SPECIFICATIONS ON | | | PLANS FOR INSULATION ON WALLS. | | | | | | PREVIOUS COMMENT: | | | FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 11C) SEMI-COMPLIED. THERE ARE NO SPECIFICATIONS ON | | | PLANS FOR INSULATION ON WALLS. | | | | | | PREVIOUS COMMENT: | | | TYPE III-TYPE V CONSTRUCTION: FBC-B-2014 720.2 | | | CONCEALED INSTALLATION. INSULATING MATERIALS, WHERE | | | CONCEALED AS INSTALLED IN BUILDINGS OF ANY TYPE OF | | | CONSTRUCTION, SHALL HAVE A FLAME SPREAD INDEX OF NOT | | | MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE | | | THAN 450. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 12) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 13) THIS REVIEW CYCLE A THOROUGH REVIEW COULD NOT BE | | | COMPLETED AND ADDITIONAL AND OR NEW COMMENTS MAY OCCUR | | | ON SUBSEQUENT REVIEWS. WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & | | | REPLACE ANY PAGES AS NECESSARY, COLLATE AND STAPLE INTO | | | SETS OF PLANS. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | NEW COMMENTS: | | | 1- PLANS ARE MISSING THE ATTIC ACCES ON SECOND FLOOR AS | | | REQUIRED BY SEC. 1209.2 FBC | | | | | | 2- FLOOR DESIGN CRITERIA ON SHEET A-11 NEEDS TO BE | | | COORDINATED WITH 2ND FLOOR FRAMING SPECIFICATIONS SHOWN | | | ON PLAN AND THE CLEAR SPAN ON SHEET A-12. . JOIST DEPTH | | | DOESN'T MATCH AND THE MAXIMUM CLEAR SPAN TABLES SHOWN | | | ON SHEET A-12 DON'T INCLUDE THE LIVE AND DEAD LOADS | | | REQUIRED FOR THE 2ND FLOOR CONVERSATION PORCH. REVISE | | | AS REQUIRED. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | | | 3- TRUSS PACKAGE: | | | A) FLAT ROOF AREA ABOVE THE CASUAL ROOM AND LAUNDRY. | | | ARCHITECT OF RECORD SPECIFIED ROOF PITCH TOWARDS THE | | | PITCHED ROOF. IT LOOKS LIKE THE TRUSS DRAWINGS ARE | | | DESIGNED WITH THE SLOPE TOWARDS THE WALL OF THE | | | CONVERSATION PORCH. DIVERTING THE WATER TOWARDS THE | | | CONVERSATION PORCH WALL WILL AFFECT THE DESIGN OF THE | | | ROOF STRUCTURE. REVISE AS REQUIRED TO MATCH. SEC. | | | 107.2.1 CITY AMENDMENTS. | | | | | | B) TRUSS ENGINEER TO PROVIDE ORIGINAL SEAL AND | | | SIGNATURE ON THE TRUSS PACKAGE COVER PAGE AND PROVIDE | | | THE NAME OF THE DESIGNER OF RECORD AS REQUIRED BY SEC. | | | 61G15-31.003. | | | | | | ****PLEASE SUBMIT OLD DRAWINGS FOR REFERENCE.. | | | | | | IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT | | | JULIO GOMEZ | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | BUILDING DIVISION | | | (561)805-6712 | | | [email protected] |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-09-26 |
Time |
14:35 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-09-26 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2017-09-26 14:35:02 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17041276 | | | ADD: 1626 OKEECHOBEE RD. | | | CONT: ERETZOR CONSTRUCTION LLC | | | TEL: 954-937-7041 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2ND REVIEW | | | DATE: TUES. SEPT. 26/ 2017 | | | ACTION: DENIED | | | | | | 4X FEE / NOTICE!!!!! FLORIDA STATUTE 553.80(2)(B). | | | | | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | | | | 1) COVERSHEET A-1: | | | | | | 1A) SEMI-COMPLIED. THE COVERSHEET A-1 HAS COMPLIED WITH | | | THE WORDING IN THE TITLE BLOCK. WITHIN THE BODY OF THE | | | PLANS, THE DESIGN PROFESSIONAL STILL INDICATES THIS TO | | | BE A LEVEL III ALTERATION. | | | 1ST ROUND OF COMMENTS. THE PERMIT APPLICATION UNDER THE | | | DESCRIPTION OF WORK INDICATES NEW BUILDINGS, TWO | | | STORIES WHEREAS THE TITLE BLOCK INDICATES THIS IS AN | | | INTERIOR REMODEL. DISCREPANCY IN THE DESCRIPTION OF | | | WORK. 107.2.1.3 ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 1B) 2ND REQUEST. THE DESIGNER OF RECORD HAS NOT | | | PROVIDED A CODE ANALYSIS, PROVIDING THE OCCUPANCY TYPE, | | | USAGE, (ALCOHOL AND OR DRUG CENTER, GROUP HOME), THE | | | TYPE OF MINIMUM CONSTRUCTION REQUIRED, OR IF FIRE | | | SPRINKLERED. NOTE FIRE SPRINKLER PLANS FOR R13 SYSTEM | | | SUBMITTED. | | | 1ST ROUND OF COMMENTS. THE COVERSHEET APPEARS TO BE THE | | | CODE ANALYSIS FOR THE BUILDING INFORMATION. THERE IS NO | | | INDEX SHEET LISTING WHERE THIS INFORMATION CAN BE | | | FOUND. WITHOUT THE OCCUPANCY TYPE BEING DECLARED AND | | | THE MINIMUM BUILDING TYPE DECLARED IT IS ONLY | | | ASSUMPTIONS, A THOROUGH REVIEW CANNOT BE ACCOMPLISHED. | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 2. OCCUPANCY TYPE 301.1 SHORT TERM FACILITY OR LONG | | | TERM FACILITY. PLEASE NOTE ON THE COVERSHEET THERE IS A | | | NOTE STATING THIS IS A SHORT TERM FACILITY. WHEN | | | DEFINING SHORT TERM THE BUILDING CODE USES 30 DAYS OR | | | LESS FOR SHORT TERM (TRANSIENT), LONGER STAYS ARE | | | (NON-TRANSIENT). IT APPEARS THIS USAGE IS MORE OF A R4 | | | FACILITY AN ALCOHOL AND OR DRUG REHAB CENTER WITH | | | CONGREGATE CARE FACILITIES, (A BUILDING OR PART THERE | | | OF THAT CONTAINS SLEEPING UNITS WHERE THE RESIDENTS | | | SHARE BATHROOMS AND OR KITCHEN FACILITIES. THE OTHER | | | ISSUE IS WITH THE UNITS CONTAINING 2 BEDROOMS AND 2 | | | OCCUPANTS PER BEDROOM AND SHARED BATHROOMS AND OR | | | KITCHEN FACILITIES THE UNIT ALSO RESEMBLES DORMITORIES! | | | PLEASE DECLARE OCCUPANCY AND USAGE. 2014 FBC-B 302.1 | | | CLASSIFICATION. | | | | | | THE OTHER ISSUE IS THE NOTE FOUND ON SHEET A-17 & A-18 | | | THAT THIS BUILDING IS A PRIVATE FACILITY NOT OPEN TO | | | THE GENERAL PUBLIC OR RENTED OUT TO THE GENERAL PUBLIC. | | | HOW DOES ONE END UP AS A TENANT AT THIS ESTABLISHMENT. | | | THE DESIGNER OF RECORD WITH NOT DEFINING THE OCCUPANCY | | | TYPE AND USAGE WE CAN NOT DEFINE WHICH THE DESIGNER | | | MUST DESIGN TOO, FAIR HOUSING OR THE 2014 | | | FBC-ACCESSIBILITY CODE, NOT ADAAG. | | | NOTE THE FLORIDA ACCESSIBILITY CODE IS BLESSED BY THE | | | DEPARTMENT OF JUSTICE, AND A MORE RESTRICTIVE CODE. | | | IT IS TRUE YOU MAY NOT REQUIRE AN ELEVATOR BUT DOES NOT | | | RELIEVE THE DESIGNER FROM THE DUTY OF VERTICAL | | | ACCESSIBILITY, ON THE OTHER HAND IF THIS FACILITY IS | | | DETERMINED TO FALL UNDER THE GUIDELINES OF FAIR HOUSING | | | THEN THE 2014 FBC FAIR HOUSING ACCESSIBILITY GUIDELINES | | | WOULD APPLY. PLEASE DECLARE OCCUPANCY AND USAGE. 2014 | | | FBC-B 302.1 CLASSIFICATION. | | | | | | | | | 3) 2ND REQUEST. MINIMUM TYPE OF CONSTRUCTION (TABLE | | | 503) | | | | | | 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL | | | INCLUDE THE FOLLOWING COMPONENTS: | | | FIRE-RESISTANT SEPARATIONS | | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | | FIRE BLOCKING AND DRAFTSTOPPING AND CALCULATED FIRE | | | RESISTANCE | | | 5.COMPLIED. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: | | | SCHEMATIC FIRE SPRINKLERS | | | STANDPIPES | | | PRE-ENGINEERED SYSTEMS | | | | | | 6-7) COMPLIED. LIFE SAFETY SYSTEMS SHALL BE DETERMINED | | | AND SHALL INCLUDE THE FOLLOWING REQUIREMENTS: | | | OCCUPANT LOAD AND EGRESS CAPACITIES | | | | | | 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | NO LIFE SAFETY SHEET!!!!!!! PROVIDE THE AMOUNT OF BEDS | | | PER SLEEPING ROOM | | | OCCUPANCY LOADS | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | DOORS | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | SPECIFIC OCCUPANCY REQUIREMENTS | | | | | | 10) FL. ACCESSIBILITY CODE OR FAIR HOUSING, VERTICAL | | | ACCESSIBILITY? | | | ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE FOLLOWING: | | | SITE REQUIREMENTS | | | ACCESSIBLE ROUTE | | | VERTICAL ACCESSIBILITY | | | TOILET AND BATHING FACILITIES | | | DRINKING FOUNTAINS | | | EQUIPMENT | | | SPECIAL OCCUPANCY REQUIREMENTS | | | FAIR HOUSING REQUIREMENTS | | | | | | 11. NO FINISH SCHEDULE!!!!INTERIOR REQUIREMENTS SHALL | | | INCLUDE THE FOLLOWING: | | | INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT) | | | LIGHT AND VENTILATION | | | SANITATION | | | | | | 12.2ND REQUEST TO BE DETERMINED , SPECIAL SYSTEMS: | | | ELEVATORS | | | LIFTS | | | | | | 1C) 2ND REQUEST. THE PLANS DO NOT INDICATE IF THE | | | CONCEPT FOR THIS PROJECT TO BE CONSIDERED 1 BUILDING | | | (TOTAL SQUARE FOOT, FOOT PRINT OR IF THEY ARE TRYING TO | | | COMPLY UNDER THE BUILDINGS ON THE SAME LOT, SECTION | | | 503.1.2. | | | | | | 1D) COMPLIED. FIRE SPRINKLER PLANS. | | | | | | 1E) SHEET A2.1 DESIGN LIVE LOADS PLANS INDICATE: STAIRS | | | & CORRIDORS 60 PSF CORRECT. | | | 2014 FBC-B TABLE 1607.1(30) STAIRS 100 PSF, | | | 2014 FBC-B TABLE 1607.1(25) PUBLIC ROOMS & CORRIDORS | | | 100 PSF | | | | | | SHEET A2.1 DESIGN LIVE LOADS PLANS INDICATE: BALCONIES | | | 30 PSF | | | 2014 FBC-B TABLE 1607.1(5) BALCONIES & DECKS ? SAME AS | | | OCCUPANCY SERVED. | | | 2014 FBC-B TABLE 1607.1(25) PRIVATE ROOMS AND CORRIDORS | | | SERVING THEM 40 PSF. | | | | | | 2) 2ND REQUEST. 2014 FBC-B 1803.5.2 QUESTIONABLE SOIL. | | | WHERE THE CLASSIFICATION, STRENGTH OR COMPRESSIBILITY | | | OF THE SOIL IS IN DOUBT OR WHERE A LOAD-BEARING VALUE | | | SUPERIOR TO THAT SPECIFIED IN THIS CODE IS CLAIMED, THE | | | BUILDING OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 3)2ND REQUEST, SEE MECHANICAL COMMENTS. PLEASE SUBMIT | | | ENERGY CALCULATIONS. 2014 FBC-ENERGY CODE. C401.2 | | | APPLICATION. | | | COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE | | | FOLLOWING: | | | 1. THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1. | | | 2. THE REQUIREMENTS OF SECTIONS C402, C403, C404 AND | | | C405. IN ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY | | | WITH EITHER SECTION C406.2, C406.3 OR C406.4. | | | 3. THE REQUIREMENTS OF SECTION C407, C402.4, C403.2, | | | C404, C405.2, C405.3, C405.4, C405.6 AND C405.7. THE | | | BUILDING ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 | | | PERCENT OF THE STANDARD REFERENCE DESIGN BUILDING. | | | | | | 4) 2ND REQUEST. ART IN PUBLIC PLACES. THE CITY OF WEST | | | PALM BEACH ART IN PUBLIC PLACES ORDINANCE REQUIREMENT | | | THAT APPLIES TO ANY REMODEL OR NEW CONSTRUCTION PROJECT | | | FOR WHICH THE PERMIT APPLICATION WAS SUBMITTED AFTER | | | 6/29/14, AND THE TOTAL PROJECT CONSTRUCTION COSTS ARE | | | EQUAL TO OR GREATER THAN $750,000 WILL NEED TO COMPLY | | | WITH THIS ORDINANCE. PER CITY OF WEST PALM BEACH | | | ORDINANCE NO. 4504-14, AND CITY OF WEST PALM BEACH CODE | | | OF ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION | | | 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS | | | 1% OF THE TOTAL PROJECT CONSTRUCTION COST. | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | FOR CONTACT INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | | 822-1515 E-MAIL: [email protected] | | | | | | 5) COMPLIED. | | | | | | 6) 2ND REQUEST. PLEASE SHOW HOW COMPLIANCE WITH FBC-B | | | SECTION 420 IS ACHIEVED. PLEASE REVIEW 2014 FBC-B 310.6 | | | GROUP R-4 OCCUPANCIES SHALL MEET THE REQUIREMENTS FOR | | | R-3 CONSTRUCTION EXCEPT, AS OTHERWISE PROVIDED IN THIS | | | CODE. | | | 420.1 OCCUPANCIES IN GROUPS I-1, R-1, R-2 AND R-3 SHALL | | | COMPLY WITH THE PROVISIONS OF SECTIONS 420.1 THROUGH | | | 420.5 AND OTHER APPLICABLE PROVISIONS OF THIS CODE. | | | | | | 6A) 420.2 SEPARATION WALLS. WALLS SEPARATING DWELLING | | | UNITS IN THE SAME BUILDING, WALLS SEPARATING SLEEPING | | | UNITS IN THE SAME BUILDING AND WALLS SEPARATING | | | DWELLING OR SLEEPING UNITS FROM OTHER OCCUPANCIES | | | CONTIGUOUS TO THEM IN THE SAME BUILDING SHALL BE | | | CONSTRUCTED AS FIRE PARTITIONS IN ACCORDANCE WITH | | | SECTION 708. | | | | | | 6B) 420.3 HORIZONTAL SEPARATION. FLOOR ASSEMBLIES | | | SEPARATING DWELLING UNITS IN THE SAME BUILDINGS, FLOOR | | | ASSEMBLIES SEPARATING SLEEPING UNITS IN THE SAME | | | BUILDING AND FLOOR ASSEMBLIES SEPARATING DWELLING OR | | | SLEEPING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO | | | THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED AS | | | HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711. | | | | | | 6C) COMPLIED. [F] 420.4 AUTOMATIC SPRINKLER SYSTEM. | | | GROUP R OCCUPANCIES SHALL BE EQUIPPED THROUGHOUT WITH | | | AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH | | | SECTION 903.2.8. GROUP I-1 OCCUPANCIES SHALL BE | | | EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM | | | IN ACCORDANCE WITH SECTION 903.2.6. QUICKRESPONSE OR | | | RESIDENTIAL AUTOMATIC SPRINKLERS SHALL BE INSTALLED IN | | | ACCORDANCE WITH SECTION 903.3.2. | | | | | | 6D) [F] 420.5 SMOKE DETECTION AND FIRE ALARM SYSTEMS. | | | FIRE ALARM SYSTEMS AND SMOKE ALARMS SHALL BE PROVIDED | | | IN GROUP I-1, R-1 AND R-2 OCCUPANCIES IN ACCORDANCE | | | WITH SECTIONS 907.2.6, 907.2.8 AND 907.2.9, | | | RESPECTIVELY. SINGLE-OR MULTIPLE-STATION SMOKE ALARMS | | | SHALL BE IN ACCORDANCE WITH SECTION 907.2.11. | | | | | | 7A)2ND REQUEST. THE COVERSHEET NOW INDICATES WIND | | | DESIGN. THE COVERSHEET UNDER THE WIND DESIGN INDICATES | | | A BASIC WIND SPEED OF 160 MPH, THEN 2 LINES DOWN A WIND | | | SPEED IN 3 SECOND GUST OF 140 MPH. THEN ON SHEET A2.1 | | | WIND SPEED OF 170 MPH. PLEASE SEE THE 2014 FBC-B FIGURE | | | 1609A FOR BUILDINGS WITH A RISK CATEGORY II. THE FIGURE | | | SHOWS THE CITY OF WEST PALM BEACH IN A WIND ZONE OF 170 | | | VULT/ 3 SECOND GUST. THE WIND SPEED CONVERSION TABLE | | | 1609.3.1 INDICATES FOR 170 VULT THE CONVERSION TO VASD | | | WILL BE 132 VASD/ 3 SECOND GUST. PLEASE CORRECT. | | | | | | 7B) THE WIND PRESSURES PROVIDED ON SHEETS A8 & A9 DO | | | NOT INDICATE THEY ARE IN VULT. THE PRESSURES IN ALL OF | | | THE PRODUCT APPROVALS ARE VASD, PLEASE PROVIDE THE | | | PRESSURES IN VASD. ULTIMATE DESIGN WIND SPEED, VULT, | | | (3-SECOND GUST), MILES PER HOUR (KM/HR) AND NOMINAL | | | DESIGN WIND SPEED, VASD, AS DETERMINED IN ACCORDANCE | | | WITH SECTION 1609.3.1. | | | 1ST REVIEW. SHEET A8 & A9 SHOW PRESSURES FOR COMPONENTS | | | AND CLADDING, BUT THERE IS NO WIND DESIGN CRITERIA TO | | | KNOW IF THESE PRESSURES ARE ACCURATE. 2014 FBC-B | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 7.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 7.2. RISK CATEGORY. | | | | | | 7.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. | | | | | | 7.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 7.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 8) 2ND REQUEST, UNTIL THE WIND DESIGN PRESSURES ARE IN | | | DESIGN PRESSURES (VASD) THE PRODUCT APPROVALS SUBMITTED | | | CAN NOT BE CHECKED FOR CODE COMPLIANCE. | | | 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | VENTILATORS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL | | | 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | | | | 9) IDENTIFY GLAZING/ MULLIONS. FOR ALL PRODUCTS WITH | | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | | TYPE OF GLAZING, MULLION INFORMATION IF REQUIRED, | | | ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING | | | SIZE. 2014 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND | | | DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED | | | MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING | | | SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE | | | CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN | | | THE TESTS. | | | | | | 10) 2ND ROUND OF COMMENTS. SHEET A15.1 SHOW POST FOR | | | HANDRAIL ANCHORING. THE PLANS SUBMITTED DOES NOT SHOW | | | THE HANDRAIL HEIGHT (1012.2) GRASPABILITY (1012.3), | | | CONTINUITY (1012.4) EXTENSIONS IF REQUIRED (1012.6), | | | GUARDS 1013.3, OPENING LIMITATIONS (1013.4), | | | 1607.8.1.1 CONCENTRATED LOAD. HANDRAILS AND GUARDS | | | SHALL ALSO BE DESIGNED TO RESIST A CONCENTRATED LOAD OF | | | 200 POUNDS IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7. | | | 1607.8.1.2 INTERMEDIATE RAILS. INTERMEDIATE RAILS (ALL | | | THOSE EXCEPT THE HANDRAIL), BALUSTERS AND PANEL FILLERS | | | SHALL BE DESIGNED TO RESIST A CONCENTRATED LOAD OF 50 | | | POUNDS IN ACCORDANCE WITH SECTION 4.5.1 OF ASCE 7. | | | 1ST ROUND OF COMMENTS. PLANS ARE DEFICIENT IN STAIR | | | DESIGN AS TO TYPE OF MATERIAL, LOADING PER SQ. FT. | | | THERE IS NO HANDRAIL OR GUARDRAIL DESIGN WITHIN THE | | | PERMIT PACKAGE SET OF PLANS. | | | | | | 11) 2ND REQUEST. THE PLANS DO NOT INDICATE WHAT THE 2ND | | | FLOOR FINISHES WILL BE? PLEASE SHOW COMPLIANCE WITH: | | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | | LISTED UNDER EACH OF THE STANDARDS FOR A HAMBRO FLOOR | | | SYSTEM/ NO DROPPED CEILING: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | 11A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 11B) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 11C) TYPE III-TYPE V CONSTRUCTION: FBC-B-2014 720.2 | | | CONCEALED INSTALLATION. INSULATING MATERIALS, WHERE | | | CONCEALED AS INSTALLED IN BUILDINGS OF ANY TYPE OF | | | CONSTRUCTION, SHALL HAVE A FLAME SPREAD INDEX OF NOT | | | MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE | | | THAN 450. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 12) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 13) THIS REVIEW CYCLE A THOROUGH REVIEW COULD NOT BE | | | COMPLETED AND ADDITIONAL AND OR NEW COMMENTS MAY OCCUR | | | ON SUBSEQUENT REVIEWS. WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & | | | REPLACE ANY PAGES AS NECESSARY, COLLATE AND STAPLE INTO | | | SETS OF PLANS. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-15 |
Time |
09:52 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-15 |
Time |
08:20 |
Sent To |
|
|
| Notes |
| 2017-05-15 09:44:24 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17041276 | | | ADD: 1626 OKEECHOBEE RD. | | | CONT: ERETZOR CONSTRUCTION LLC | | | TEL: 954-937-7041 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 1ST REVIEW | | | DATE: MON. MAY 15/ 2017 | | | ACTION: DENIED | | | | | | 1) COVERSHEET A-1: | | | | | | 1A) THE PERMIT APPLICATION UNDER THE DESCRIPTION OF | | | WORK INDICATES NEW BUILDINGS, TWO STORIES WHEREAS THE | | | TITLE BLOCK INDICATES THIS IS AN INTERIOR REMODEL. | | | DISCREPANCY IN THE DESCRIPTION OF WORK. 107.2.1.3 | | | ADDITIONAL INFORMATION IS REQUIRED. | | | | | | 1B) THE COVERSHEET APPEARS TO BE THE CODE ANALYSIS FOR | | | THE BUILDING INFORMATION. THERE IS NO INDEX SHEET | | | LISTING WHERE THIS INFORMATION CAN BE FOUND. WITHOUT | | | THE OCCUPANCY TYPE BEING DECLARED AND THE MINIMUM | | | BUILDING TYPE DECLARED IT IS ONLY ASSUMPTIONS, A | | | THOROUGH REVIEW CANNOT BE ACCOMPLISHED. | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 2. OCCUPANCY TYPE 301.1 SHORT TERM FACILITY OR LONG | | | TERM FACILITY | | | 3) MINIMUM TYPE OF CONSTRUCTION (TABLE 503) | | | 4. FIRE-RESISTANT CONSTRUCTION REQUIREMENTS SHALL | | | INCLUDE THE FOLLOWING COMPONENTS: | | | FIRE-RESISTANT SEPARATIONS | | | FIRE-RESISTANT PROTECTION FOR TYPE OF CONSTRUCTION | | | PROTECTION OF OPENINGS AND PENETRATIONS OF RATED WALLS | | | FIRE BLOCKING AND DRAFTSTOPPING AND CALCULATED FIRE | | | RESISTANCE | | | 5. FIRE SUPPRESSION SYSTEMS SHALL INCLUDE: | | | SCHEMATIC FIRE SPRINKLERS | | | STANDPIPES | | | PRE-ENGINEERED SYSTEMS | | | 6. LIFE SAFETY SYSTEMS SHALL BE DETERMINED AND SHALL | | | INCLUDE THE FOLLOWING REQUIREMENTS: | | | OCCUPANT LOAD AND EGRESS CAPACITIES | | | 7. OCCUPANCY LOAD/EGRESS REQUIREMENTS SHALL INCLUDE: | | | NO LIFE SAFETY SHEET!!!!!!! PROVIDE THE AMOUNT OF BEDS | | | PER SLEEPING ROOM | | | OCCUPANCY LOADS | | | GROSS | | | NET | | | MEANS OF EGRESS | | | EXIT ACCESS | | | EXIT | | | EXIT DISCHARGE | | | DOORS | | | EMERGENCY LIGHTING AND EXIT SIGNS | | | SPECIFIC OCCUPANCY REQUIREMENTS | | | 10) FL. ACCESSIBILITY CODE OR FAIR HOUSING, VERTICAL | | | ACCESSIBILITY? | | | ACCESSIBILITY REQUIREMENTS SHALL INCLUDE THE FOLLOWING: | | | SITE REQUIREMENTS | | | ACCESSIBLE ROUTE | | | VERTICAL ACCESSIBILITY | | | TOILET AND BATHING FACILITIES | | | DRINKING FOUNTAINS | | | EQUIPMENT | | | SPECIAL OCCUPANCY REQUIREMENTS | | | FAIR HOUSING REQUIREMENTS | | | | | | 11. NO FINISH SCHEDULE!!!!INTERIOR REQUIREMENTS SHALL | | | INCLUDE THE FOLLOWING: | | | INTERIOR FINISHES (FLAME SPREAD/SMOKE DEVELOPMENT) | | | LIGHT AND VENTILATION | | | SANITATION | | | 12. SPECIAL SYSTEMS: | | | ELEVATORS | | | ESCALATORS | | | LIFTS | | | | | | | | | | | | 1C) THE PLANS DO NOT INDICATE IF THE CONCEPT FOR THIS | | | PROJECT TO BE CONSIDERED 1 BUILDING (TOTAL SQUARE FOOT, | | | FOOT PRINT OR IF THEY ARE TRYING TO COMPLY UNDER THE | | | BUILDINGS ON THE SAME LOT, SECTION 503.1.2. | | | | | | 1D) FIRE SPRINKLER PLANS WILL BE REQUIRED FOR EITHER AN | | | I OCCUPANCY (903.2.6) OR AN R OCCUPANCY (903.2.8.) | | | W. P. B. ADMINISTRATIVE CODE105.3.1.2(2) FIRE SPRINKLER | | | DOCUMENTS FOR ANY NEW BUILDING OR ADDITION WHICH | | | INCLUDES A FIRE SPRINKLER SYSTEM WHICH CONTAINS 50 OR | | | MORE SPRINKLER HEADS. A CONTRACTOR I, CONTRACTOR II OR | | | CONTRACTOR IV, CERTIFIED UNDER SECTION 633.521, FLORIDA | | | STATUTES, MAY DESIGN A FIRE | | | SPRINKLER SYSTEM OF 49 OR FEWER HEADS AND MAY DESIGN | | | THE ALTERATION OF AN EXISTING FIRE SPRINKLER SYSTEM IF | | | THE ALTERATION CONSISTS OF THE RELOCATION, ADDITION OR | | | DELETION OF NOT MORE THAN 49 HEADS, NOT WITHSTANDING | | | THE SIZE OF THE EXISTING FIRE SPRINKLER SYSTEM. | | | | | | 2) 2014 FBC-B 1803.5.2 QUESTIONABLE SOIL. WHERE THE | | | CLASSIFICATION, STRENGTH OR COMPRESSIBILITY OF THE SOIL | | | IS IN DOUBT OR WHERE A LOAD-BEARING VALUE SUPERIOR TO | | | THAT SPECIFIED IN THIS CODE IS CLAIMED, THE BUILDING | | | OFFICIAL SHALL BE PERMITTED TO REQUIRE THAT A | | | GEOTECHNICAL INVESTIGATION BE CONDUCTED. | | | | | | 3) PLEASE SUBMIT ENERGY CALCULATIONS. 2014 FBC-ENERGY | | | CODE. C401.2 APPLICATION. | | | COMMERCIAL BUILDINGS SHALL COMPLY WITH ONE OF THE | | | FOLLOWING: | | | 1. THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1. | | | 2. THE REQUIREMENTS OF SECTIONS C402, C403, C404 AND | | | C405. IN ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY | | | WITH EITHER SECTION C406.2, C406.3 OR C406.4. | | | 3. THE REQUIREMENTS OF SECTION C407, C402.4, C403.2, | | | C404, C405.2, C405.3, C405.4, C405.6 AND C405.7. THE | | | BUILDING ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85 | | | PERCENT OF THE STANDARD REFERENCE DESIGN BUILDING. | | | | | | 4) ART IN PUBLIC PLACES. THE CITY OF WEST PALM BEACH | | | ART IN PUBLIC PLACES ORDINANCE REQUIREMENT THAT APPLIES | | | TO ANY REMODEL OR NEW CONSTRUCTION PROJECT FOR WHICH | | | THE PERMIT APPLICATION WAS SUBMITTED AFTER 6/29/14, AND | | | THE TOTAL PROJECT CONSTRUCTION COSTS ARE EQUAL TO OR | | | GREATER THAN $750,000 WILL NEED TO COMPLY WITH THIS | | | ORDINANCE. PER CITY OF WEST PALM BEACH ORDINANCE NO. | | | 4504-14, AND CITY OF WEST PALM BEACH CODE OF | | | ORDINANCES, ARTICLE V, ART IN PUBLIC PLACES, SECTION | | | 78-123(A) AND SECTION 78-126(A), THE ART ASSESSMENT IS | | | 1% OF THE TOTAL PROJECT CONSTRUCTION COST. | | | PER CITY OF WEST PALM BEACH CODE OF ORDINANCES, ARTICLE | | | V, ART IN PUBLIC PLACES, SECTION 78-122, RENOVATION AND | | | NEW CONSTRUCTION PROJECTS ARE ASSESSED CUMULATIVELY, SO | | | THE ART ASSESSMENT WILL BE APPLICABLE TO ALL FUTURE | | | PROJECTS. | | | FOR CONTACT INFORMATION PLEASE CONTACT: | | | MS. SYBILLE WELTER ART IN PUBLIC PLACES COORDINATOR | | | 822-1515 E-MAIL: [email protected] | | | | | | 5) SHEET A4: UNITS 1A, 1B, 2D & 2E ALL SHOW WHAT | | | APPEARS TO BE EITHER A DIVIDER OR PONY WALL (HALF | | | WALL). | | | THE PLANS DO NOT HAVE A DETAIL OF THIS AREA, AND THERE | | | IS NO FURNITURE PLAN SHOWING IF THERE IS 2 BEDS OR 4 | | | BEDS IN EACH OF THE IDENTIFIED BEDROOMS. AGAIN THE | | | OCCUPANT LOAD CANNOT BE IDENTIFIED NOR CAN THE PLUMBING | | | FIXTURE COUNT. FBC-B TABLE 1004.1.2. | | | | | | 6) PLEASE SHOW HOW COMPLIANCE WITH FBC-B SECTION 420 IS | | | ACHIEVED. | | | 420.1 OCCUPANCIES IN GROUPS I-1, R-1, R-2 AND R-3 SHALL | | | COMPLY WITH THE PROVISIONS OF SECTIONS 420.1 THROUGH | | | 420.5 AND OTHER APPLICABLE PROVISIONS OF THIS CODE. | | | | | | 420.2 SEPARATION WALLS. WALLS SEPARATING DWELLING UNITS | | | IN THE SAME BUILDING, WALLS SEPARATING SLEEPING UNITS | | | IN THE SAME BUILDING AND WALLS SEPARATING DWELLING OR | | | SLEEPING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO | | | THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED AS FIRE | | | PARTITIONS IN ACCORDANCE WITH SECTION 708. | | | | | | 420.3 HORIZONTAL SEPARATION. FLOOR ASSEMBLIES | | | SEPARATING DWELLING UNITS IN THE SAME BUILDINGS, FLOOR | | | ASSEMBLIES SEPARATING SLEEPING UNITS IN THE SAME | | | BUILDING AND FLOOR ASSEMBLIES SEPARATING DWELLING OR | | | SLEEPING UNITS FROM OTHER OCCUPANCIES CONTIGUOUS TO | | | THEM IN THE SAME BUILDING SHALL BE CONSTRUCTED AS | | | HORIZONTAL ASSEMBLIES IN ACCORDANCE WITH SECTION 711. | | | | | | [F] 420.4 AUTOMATIC SPRINKLER SYSTEM. GROUP R | | | OCCUPANCIES SHALL BE EQUIPPED THROUGHOUT WITH AN | | | AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH SECTION | | | 903.2.8. GROUP I-1 OCCUPANCIES SHALL BE EQUIPPED | | | THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN | | | ACCORDANCE WITH SECTION 903.2.6. QUICKRESPONSE OR | | | RESIDENTIAL AUTOMATIC SPRINKLERS SHALL BE INSTALLED IN | | | ACCORDANCE WITH SECTION 903.3.2. | | | | | | [F] 420.5 SMOKE DETECTION AND FIRE ALARM SYSTEMS. FIRE | | | ALARM SYSTEMS AND SMOKE ALARMS SHALL BE PROVIDED IN | | | GROUP I-1, R-1 AND R-2 OCCUPANCIES IN ACCORDANCE WITH | | | SECTIONS 907.2.6, 907.2.8 AND 907.2.9, RESPECTIVELY. | | | SINGLE-OR MULTIPLE-STATION SMOKE ALARMS SHALL BE IN | | | ACCORDANCE WITH SECTION 907.2.11. | | | | | | 7) SHEET A8 & A9 SHOW PRESSURES FOR COMPONENTS AND | | | CLADDING, BUT THERE IS NO WIND DESIGN CRITERIA TO KNOW | | | IF THESE PRESSURES ARE ACCURATE. 2014 FBC-B 1603.1.4 | | | WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | | | | 7.1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | | | | 7.2. RISK CATEGORY. | | | | | | 7.3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. TABLE 1609.7.2. | | | HEIGHT AND EXPOSURE. | | | | | | 7.4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | | | | 7.5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | TABLE 1609.7(2) ADJUSTMENT FACTORS FOR HEIGHT & | | | EXPOSURE. PROVIDE THE MEAN ROOF HEIGHT FOR THE | | | BUILDING. | | | 1609.3.1 WIND SPEED CONVERSION VULT TO VASD. | | | | | | 8) 2010/ 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(A) EXTERIOR DOORS ,MULLIONS & ROOF HATCHES. | | | (B) WINDOWS & MULLIONS | | | (C) PANEL WALLS: STOREFRONTS, CURTAIN WALLS, WALL | | | LOUVERS, EFIS SYSTEMS, | | | (D) ROOFING PRODUCTS AND ASSEMBLIES, ROOF TOP | | | VENTILATORS | | | (E) SHUTTERS | | | (F) SKYLIGHTS | | | (G) EXTERIOR COOLER, FREEZERS & PRE-ENGINEERED A/C | | | STANDS | | | | | | FBC 107.3.4.1 PRODUCT APPROVALS. THOSE PRODUCTS WHICH | | | ARE REGULATED BY THE DCA RULE 9N-03 SHALL BE REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD PRIOR | | | TO SUBMITTAL FOR JURISDICTIONAL APPROVAL. FL | | | 61G1-23.015 (2) THE ARCHITECT IS RESPONSIBLE FOR | | | SUPERVISING AND REVIEWING ALL PROJECT DATA, REPORTS, | | | SHOP DRAWINGS ETC.. | | | | | | 107.3.4.2 DEFERRED SUBMITTALS. FOR THE PURPOSES OF THIS | | | SECTION, DEFERRED SUBMITTALS ARE DEFINED AS THOSE | | | PORTIONS OF THE DESIGN THAT ARE NOT SUBMITTED AT THE | | | TIME OF THE APPLICATION AND THAT ARE TO BE SUBMITTED TO | | | THE BUILDING OFFICIAL WITHIN A SPECIFIED PERIOD. | | | DEFERRAL OF ANY SUBMITTAL ITEMS SHALL HAVE THE PRIOR | | | APPROVAL OF THE BUILDING OFFICIAL. THE REGISTERED | | | DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE SHALL LIST | | | THE DEFERRED SUBMITTALS ON THE CONSTRUCTION DOCUMENTS | | | FOR REVIEW BY THE BUILDING OFFICIAL. | | | | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | | | | | | | 9) IDENTIFY GLAZING/ MULLIONS. FOR ALL PRODUCTS WITH | | | GLAZING, PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, | | | TYPE OF GLAZING, MULLION INFORMATION IF REQUIRED, | | | ATTACHMENTS AND ASSOCIATE PRESSURES FOR EACH OPENING | | | SIZE. 2014 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND | | | DOORS SHALL BE INSTALLED IN ACCORDANCE WITH APPROVED | | | MANUFACTURERS INSTRUCTIONS. FASTENER SIZE AND SPACING | | | SHALL BE PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE | | | CALCULATED BASED ON MAXIMUM LOADS AND SPACING USED IN | | | THE TESTS. | | | | | | 10) PLANS ARE DEFICIENT IN STAIR DESIGN AS TO TYPE OF | | | MATERIAL, LOADING PER SQ. FT. THERE IS NO HANDRAIL OR | | | GUARDRAIL DESIGN WITHIN THE PERMIT PACKAGE SET OF | | | PLANS. | | | | | | 11) THE PLANS DO NOT INDICATE WHAT THE 2ND FLOOR | | | FINISHES WILL BE? PLEASE SHOW COMPLIANCE WITH: | | | FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO | | | HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES | | | TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS | | | LISTED UNDER EACH OF THE STANDARDS FOR A HAMBRO FLOOR | | | SYSTEM/ NO DROPPED CEILING: | | | PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH: | | | 11A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND. | | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492. | | | | | | 11B) FBC-B 2014 1207.2 AIR-BORNE SOUND. | | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | | E 90. | | | | | | 11C) TYPE III-TYPE V CONSTRUCTION: FBC-B-2014 720.2 | | | CONCEALED INSTALLATION. INSULATING MATERIALS, WHERE | | | CONCEALED AS INSTALLED IN BUILDINGS OF ANY TYPE OF | | | CONSTRUCTION, SHALL HAVE A FLAME SPREAD INDEX OF NOT | | | MORE THAN 25 AND A SMOKE-DEVELOPED INDEX OF NOT MORE | | | THAN 450. | | | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | | | 12) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 13) THIS REVIEW CYCLE A THOROUGH REVIEW COULD NOT BE | | | COMPLETED AND ADDITIONAL AND OR NEW COMMENTS MAY OCCUR | | | ON SUBSEQUENT REVIEWS. WHEN RESUBMITTING PLANS PLEASE | | | INDICATE THE REVISION & REMOVE ANY VOIDED SHEETS & | | | REPLACE ANY PAGES AS NECESSARY, COLLATE AND STAPLE INTO | | | SETS OF PLANS. A TRANSMITTAL LETTER LISTING THE | | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | | ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | DEVELOPMENT SERVICES HOME PAGE | | | HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP | | | | | | PLEASE NOTE: FLORIDA HAS A VERY BROAD PUBLIC RECORDS | | | LAW. WRITTEN COMMUNICATIONS TO OR FROM LOCAL OFFICIALS | | | REGARDING CITY BUSINESS ARE PUBLIC RECORD, AVAILABLE TO | | | THE PUBLIC UPON REQUEST. YOUR E-MAIL COMMUNICATIONS ARE | | | THEREFORE SUBJECT TO PUBLIC DISCLOSURE. | | | MEMBER OF BOAF: BUILDING OFFICIALS ASSOCIATION OF | | | FLORIDA SAVING LIVES AND PROPERTY SINCE 1953 | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2018-05-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-05-09 |
Time |
16:43 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-05-09 |
Time |
16:43 |
Sent To |
|
|
| Notes |
| 2018-05-09 16:43:35 | PROVISO ITEMS ON PLAN: | | | | | | 1. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 (NOT PROVIDED, WE WILL ACCEPT THIS AS | | | A DEFERRED SUBMITTAL WITH A NOTE ON PLAN INDICATING | | | THAT THE CALCULATION WILL BE PROVIDED BEFORE FINAL.) | | | 2. ALL EXTERIOR RECEPTACLES REQUIRE GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8 (RECEPTACLES FOR WATER | | | HEATERS AND A/C'S NEED GFCI ALSO) | | | 3. PROVIDE GFCI PROTECTED OUTLET ON THE KITCHEN | | | PENINSULA. NEC 210.8, 210.52(C)(3) (NOT PROVIDED) |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2018-04-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-04-16 |
Time |
14:25 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-04-16 |
Time |
10:49 |
Sent To |
|
|
| Notes |
| 2018-04-16 14:25:18 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE LOCATION OF ELECTRICAL SERVICE ON PLAN. WPB | | | FBC 107.2.1 | | | 2. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 3. BE ADVISED THAT FIRE ALARM, LOW VOLTAGE SYSTEMS, | | | DAS, LIGHTNING PROTECTION, GENERATORS, COMMERCIAL HOOD | | | SYSTEMS, SIGNS, SITE LIGHTING, AND SWIMMING POOLS | | | (WHERE APPLICABLE) ARE NOT INCLUDED IN THE SCOPE OF | | | THIS PLAN REVIEW. PROVIDE A BLOCK NOTE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR ANY OF THESE SYSTEMS PRESENT. FBC 105.1, | | | 107.2.1 | | | 4. PROVIDE CHART OF INTERIOR LIGHTING POWER ALLOWANCES | | | EXPRESSED IN WATTAGE PER THE FBC ENERGY CODE IN | | | RELATION TO THE WATTAGE OF THE CONNECTED INTERIOR | | | LIGHTING PROPOSED TO COMPLY WITH CODE FOR | | | NON-RESIDENTIAL AREAS. FOR RESIDENTAIL AREAS, PROVIDE | | | NOTE FOR COMPLIANCE: PROVIDE COMPLIANCE: "A MINIMUM OF | | | 75 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED | | | LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS OR A | | | MINIMUM OF 75 PERCENT OF THE PERMANENTLY INSTALLED | | | LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH EFFICACY | | | LAMPS". FBC EC 405.5.2 | | | 5. PROVIDE THE ADDITIONAL LIGHTING CONTROLS STIPULATED | | | IN THE FBC ENERGY CODE. MANY AREAS DO NOT SHOW THE | | | AUTOMATIC CONTROL REQUIRED. FBC EC 405.2.2, 405.2.2.2 | | | 6. PROVIDE ACCURATE LOAD CALCULATION INCLUDING ALL | | | LOADS. THE CALCULATION PROVIDED APPLIES DEMAND FACTORS | | | ONCE AT THE PANELS, AND THEN AGAIN FOR THE NUMBER OF | | | UNITS FOR THE SERVICE. DEMAND FACTORS CAN ONLY BE | | | APPLIED ONCE. SEE CODE SECTION FOR EXPLANATION. NEC | | | 220.84 | | | 7. RISER DIAGRAM SHOWS AN EQUIPMENT GROUNDING CONDUCTOR | | | IN THE CONDUIT TO FPL FROM THE METER BASE. THIS CONDUIT | | | SHOULD NOT HAVE AN EGC. PROVIDE CORRECTION. NEC 250.6 | | | 8. RISER SHOWS ONE GROUND ROD. SERVICE GROUNDING | | | ELECTRODE NEEDS TO BE AUGMENTED BY AN ADDITIONAL | | | ELECTRODE AT LEAST 6 FEET AWAY OR PROVIDE EVIDENCE OF | | | RESISTANCE TO GROUND OF 25 OHMS OR LESS. PROVIDE | | | CORRECTION. NEC 250.56 | | | 9. ALL RECEPTACLES IN KITCHEN FOR COUNTER TOP USE | | | REQUIRE GFCI PROTECTION. PROVIDE CORRECTION. NEC 210.8 | | | 10. ALL EXTERIOR RECEPTACLES REQUIRE GFCI PROTECTION. | | | PROVIDE CORRECTION. NEC 210.8 | | | 11. PROVIDE GFCI PROTECTED OUTLET ON THE KITCHEN | | | PENINSULA. NEC 210.8, 210.52(C)(3) | | | 12. PROVIDE CORRECT ADDRESS WITH CORRECT STREET NAME ON | | | PLAN. FBC 107.2.1 | | | | | | END OF COMMENTS. | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2018-04-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-09-20 |
Time |
07:12 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-09-20 |
Time |
07:12 |
Sent To |
|
|
| Notes |
| 2018-04-16 12:56:26 | CHANGED STATUS TO FAIL PER REVIEW DATED 4-16-18 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2018-04-16 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-15 |
Time |
14:19 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-05-15 |
Time |
13:09 |
Sent To |
|
|
| Notes |
| 2018-04-16 12:55:55 | CHANGED STATUS TO FAIL PER REVIEW DATED 4-16-18 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2018-04-20 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2018-04-20 |
Time |
|
Sent To |
I |
|
| Notes |
| 2018-04-05 13:15:40 | SEE E18010008 |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2017-10-12 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2017-10-12 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2017-10-12 |
Time |
|
Sent To |
I |
|
| Notes |
| 2017-10-12 16:25:47 | ADDRESS PLANNING COMMENTS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2017-05-18 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2017-05-18 |
Time |
|
Sent To |
I |
|
| Notes |
| 2017-05-18 15:46:39 | SEPERATE DEVELOPMENT PERMIT WILL BE REQUIRED THRU | | | ENGINEERING DEPARTMENT. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | | | | IMPORTANT MESSAGE: AS OF DECEMBER 20, 2015 THE CITY OF | | | WEST PALM BEACH | | | CROSS-CONNECTION CONTROL MANUAL HAS BEEN REVISED, | | | MAKING KNOWN THAT "ALL BACKFLOW DEVICES MUST BE LEAD | | | FREE." | | | FOR MORE INFORMATION REFER TO THE LINK BELOW: | | | HTTP://WPB.ORG/DEPARTMENTS/PUBLIC-UTILITIES/FORMS-PUBLI | | | CATIONS/BACKFLOW-CROSS-CONNECTION-CONTROL-MANUAL | | | | | | HTTPS://WETRANSFER.COM/ | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-04-17 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-04-17 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-04-16 |
Time |
15:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-09-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-09-05 |
Time |
15:50 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-04 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2017-05-04 14:59:59 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SHEET A 1 - THERE ARE REFERENCES TO ANY CURRENT | | | EDITIONS OF THE NFPA 1 & 101. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | PLEASE CORRECT. | | | | | | | | | 2) A LIFE SAFETY REVIEW SHEET WAS NOT PROVIDED | | | INDICATING COMPLIANCE WITH ANY LIFE SAFETY OCCUPANCY | | | CHAPTER OF NFPA 101. IT APPEARS THAT THE OCCUPANCY MAY | | | BE CHAPTER IS NFPA 101, CHAPTER 30, NEW APARTMENT | | | BUILDINGS. CHAPTER 32 RESIDENTIAL BOARD AND CARE, OR | | | CHAPTER 26 LODGING AND ROOMING HOUSES. | | | | | | IT APPEARS THAT THERE ARE TWO SEPARATE SLEEPING AREAS | | | PER BEDROOM. | | | | | | PLEASE REVIEW AND PROVIDE DETAILS AS TO THE USE AND | | | FUNCTION OF THESE APARTMENTS AND THE APPLICABLE NFPA | | | 101 OCCUPANCY CHAPTER AND ALL LIFE SAFETY FEATURES | | | REQUIREMENTS OF THAT CHAPTER. | | | | | | | | | | | | 3) SHEET A 3 - THE IS AN AREA INDICATED AS CASUAL | | | ROOM/GUEST ROOM THAT APPEARS TO BE AN ASSEMBLY | | | SPACE/OCCUPANCY. | | | | | | THERE IS NO INDICATION OF COMPLAINCE WITH THE ASSEMBLY | | | OCCPANCY CODE. | | | | | | PLEASE REVIEW AND COORECT ENSURE COMPLIANCE WITH ALL | | | APPLICABLE NFPA 101 REQUIREMENTS. | | | | | | | | | | | | 4) SHEET A 3 - A DOOR/GATE, # 11, IS INDICATED IN THE | | | PATH OF EXIT TRAVEL. BUT NO DETAIL PROVIDED AS TO THE | | | EXIT HARDWARE IN COMPLINACE WITH NFPA 101, CHAPTER 7, | | | MEANS OF EGRESS. | | | | | | 30.2.2.2 DOORS. | | | 30.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE | | | PERMITTED. | | | 30.2.2.2.2 DOOR-LOCKING ARRANGEMENTS SHALL COMPLY WITH | | | 30.2.2.2.2.1, 30.2.2.2.2.2, 30.2.2.2.2.3, OR | | | 30.2.2.2.2.4. | | | 30.2.2.2.2.1* NO DOOR IN ANY MEANS OF EGRESS SHALL BE | | | LOCKED AGAINST EGRESS WHEN THE BUILDING IS OCCUPIED. | | | | | | 7.2.1.4 SWING AND FORCE TO OPEN. | | | 7.2.1.4.1* SWINGING-TYPE DOOR ASSEMBLY REQUIREMENT. ANY | | | DOOR ASSEMBLY IN A MEANS OF EGRESS SHALL BE OF THE | | | SIDE-HINGED OR PIVOTED-SWINGING TYPE, AND SHALL BE | | | INSTALLED TO BE CAPABLE OF SWINGING FROM ANYPOSITION TO | | | THE FULL REQUIRED WIDTH OF THE OPENING IN WHICH IT IS | | | INSTALLED, UNLESS OTHERWISE SPECIFIED AS FOLLOWS: | | | (1) DOOR ASSEMBLIES IN DWELLING UNITS, AS PROVIDED IN | | | CHAPTER 24, SHALL BE PERMITTED. | | | (2) DOOR ASSEMBLIES IN RESIDENTIAL BOARD AND CARE | | | OCCUPANCIES, AS PROVIDED IN CHAPTERS 32 AND 33, SHALL | | | BE PERMITTED. | | | (3) WHERE PERMITTED IN CHAPTERS 11 THROUGH 43, | | | HORIZONTAL-SLIDING OR VERTICAL-ROLLING SECURITY GRILLES | | | OR DOOR ASSEMBLIES THAT ARE PART OF THE REQUIRED MEANS | | | OF EGRESS SHALL BE PERMITTED, PROVIDED THAT ALL OF THE | | | FOLLOWING CRITERIA ARE MET: | | | (A) SUCH GRILLES OR DOOR ASSEMBLIES SHALL REMAIN | | | SECURED IN THE FULLY OPEN POSITION DURING THE PERIOD OF | | | OCCUPANCY BY THE GENERAL PUBLIC. | | | (B) ON OR ADJACENT TO THE GRILLE OR DOOR OPENING, THERE | | | SHALL BE A READILY VISIBLE, DURABLE SIGN IN LETTERS NOT | | | LESS THAN 1 IN. (25 MM) HIGH ON A CONTRASTING | | | BACKGROUND THAT READS AS FOLLOWS: THIS DOOR TO REMAIN | | | OPEN WHEN THE BUILDING IS OCCUPIED. | | | (C) DOOR LEAVES OR GRILLES SHALL NOT BE BROUGHT TO THE | | | CLOSED POSITION WHEN THE SPACE IS OCCUPIED. | | | (D) DOOR LEAVES OR GRILLES SHALL BE OPERABLE FROM | | | WITHIN THE SPACE WITHOUT THE USE OF ANY SPECIAL | | | KNOWLEDGE OR EFFORT. | | | (E) WHERE TWO OR MORE MEANS OF EGRESS ARE REQUIRED, NOT | | | MORE THAN HALF OF THE MEANS OF EGRESS SHALL BE EQUIPPED | | | WITH HORIZONTAL-SLIDING OR VERTICAL-ROLLING GRILLES OR | | | DOOR ASSEMBLIES. | | | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES. | | | 7.2.1.5.1 DOOR LEAVES SHALL BE ARRANGED TO BE OPENED | | | READILY FROM THE EGRESS SIDE WHENEVER THE BUILDING IS | | | OCCUPIED. | | | 7.2.1.5.2* THE REQUIREMENT OF 7.2.1.5.1 SHALL NOT APPLY | | | TO DOOR LEAVES OF LISTED FIRE DOOR ASSEMBLIES AFTER | | | EXPOSURE TO ELEVATED TEMPERATURE IN ACCORDANCE WITH THE | | | LISTING, BASED ON LABORATORY FIRE TEST PROCEDURES. | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | | OF A KEY, A TOOL, OR SPECIAL KNOWLEDGE OR EFFORT FOR | | | OPERATION FROM THE EGRESS SIDE. | | | | | | | | | PLEASE PROVIDE DETAILS MEETING THE REQUIREMENTS. | | | | | | | | | | | | | | | 5) SHEET A 3 & 5 - STAIRS, HARDRAILS AND RAILINGS ARE | | | INDICATED; HOWEVER NO DETAILS ARE PROVIDED. | | | | | | PER NFPA 101, CHAPTER 7, MEANS OF EGRESS | | | | | | 7.2.2 STAIRS. | | | 7.2.2.1 GENERAL. | | | 7.2.2.1.1 STAIRS USED AS A COMPONENT IN THE MEANS OF | | | EGRESS SHALL CONFORM TO THE GENERAL REQUIREMENTS OF | | | SECTION 7.1 AND TO THE SPECIAL REQUIREMENTS OF 7.2.2, | | | UNLESS OTHERWISE SPECIFIED IN 7.2.2.1.2. | | | | | | 7.2.2.3 STAIR DETAILS. | | | 7.2.2.3.1 CONSTRUCTION. | | | 7.2.2.3.1.1 ALL STAIRS SERVING AS REQUIRED MEANS OF | | | EGRESS SHALL BE OF PERMANENT FIXED CONSTRUCTION, UNLESS | | | THEY ARE STAIRS SERVING SEATING THAT IS DESIGNED TO BE | | | REPOSITIONED IN ACCORDANCE WITH CHAPTERS 12 AND 13. | | | | | | 7.2.2.4 GUARDS AND HANDRAILS. | | | 7.2.2.4.1 HANDRAILS. | | | 7.2.2.4.1.1 STAIRS AND RAMPS SHALL HAVE HANDRAILS ON | | | BOTH SIDES, UNLESS OTHERWISE PERMITTED IN 7.2.2.4.1.5 | | | OR 7.2.2.4.1.6. | | | | | | PLEASE PROVIDE DETAILS MEETING THE REQUIREMENTS | | | | | | | | | | | | 6) SEET A 6 & 7 - THERE ARE NO EXIT SIGNS IN ANY EXIT | | | CORRIDOR OR ASSEMBLY AREAS. | | | | | | NFPA 101 | | | | | | ILLUMINATION OF MEANS OF EGRESS. MEANS OF EGRESS SHALL | | | BE ILLUMINATED IN ACCORDANCE WITH SECTION 7.8. | | | | | | MARKING OF MEANS OF EGRESS. MEANS OF EGRESS SHALL HAVE | | | SIGNS IN ACCORDANCE WITH SECTION 7.10 IN ALL BUILDINGS | | | REQUIRING MORE THAN ONE EXIT. | | | | | | | | | | | | | | | 7) ANY SHEETS - THE SUBMITTAL DOES NOT INDICATED EXITS | | | LEADING TO A PUBLIC WAY. | | | | | | DISCHARGE FROM EXITS. EXIT DISCHARGE SHALL COMPLY WITH | | | SECTION 7.7. | | | | | | 7.7 DISCHARGE FROM EXITS. | | | 7.7.1* EXIT TERMINATION. EXITS SHALL TERMINATE | | | DIRECTLY, AT A PUBLIC WAY OR AT AN EXTERIOR EXIT | | | DISCHARGE, UNLESS OTHERWISE PROVIDED IN 7.7.1.2 THROUGH | | | 7.7.1.4. | | | | | | PLEASE PROVIDE A DETAIL INDICATING COMPLIANCE WITH THE | | | REQUIREMENTS. | | | | | | | | | | | | | | | 8) NO SHEET SUBMITTALS - THERE ARE NO FIRE SPRINKLER | | | DOCUMENTS WITH THIS SUBMITTAL. | | | | | | 30.3.5 EXTINGUISHMENT REQUIREMENTS. | | | 30.3.5.1 ALL BUILDINGS SHALL BE PROTECTED THROUGHOUT BY | | | AN APPROVED, SUPERVISED AUTOMATIC SPRINKLER SYSTEM | | | INSTALLED IN ACCORDANCE WITH 30.3.5.2. | | | | | | PER FLORIDA ADMINISTRATIVE CODE SECTION 61G15-32.004, | | | FIRE PROTECTION ENGINEERING DOCUMENTS SHALL INCLUDE THE | | | POINT OF SERVICE FOR THE WATER SUPPLY, A LIST OF | | | APPLICABLE NFPA STANDARDS APPLICABLE TO THE PROJECT, | | | CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA, SUPPRESSION SYSTEM TYPE, DESIGN DENSITIES, WATER | | | SUPPLY DATA (FIRE PUMP DATA, HYDRANT FLOW TEST DATA) | | | AND ANY PERFORMANCE BASED INFORMATION SUCH AS | | | PRE-ENGINEERED SYSTEMS. | | | | | | 61G15-32.003 COMMON REQUIREMENTS TO ALL FIRE PROTECTION | | | ENGINEERING | | | DOCUMENTS. | | | (1) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | | SHALL PROVIDE THE ENGINEERING REQUIREMENTS TO BE USED | | | IN THE PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | | DOCUMENTS AND TO INDICATE THE NATURE AND SCOPE OF THE | | | WORK, AND TO DESCRIBE, DETAIL, DIMENSION, LABEL AND | | | DEFINE THE FIRE PROTECTION COMPONENTS, SYSTEM(S), | | | MATERIALS, ASSEMBLIES, EQUIPMENT AND ITS STRUCTURAL AND | | | UTILITY SUPPORT SYSTEM(S), INSOFAR AS THEY INVOLVE THE | | | SAFEGUARDING OF LIFE, HEALTH OR PROPERTY. | | | (2) THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS | | | SHALL SPECIFY THE APPLICABLE REQUIREMENTS FOR THE | | | ACCEPTANCE TESTING OF THE FIRE PROTECTION SYSTEM AND | | | COMPONENTS, WHICH SHALL BE BASED UPON APPLICABLE CODES | | | AND STANDARDS, WHERE AVAILABLE. | | | (3) THE OCCUPANCY OF THE AREA OR DESCRIPTION OF A | | | SPECIFIC HAZARD BEING PROTECTED BY THE FIRE PROTECTION | | | SYSTEM(S) SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. | | | (4) THE APPLICABLE CODE AND STANDARD TO BE USED IN THE | | | PREPARATION OF THE FIRE PROTECTION SYSTEM LAYOUT | | | DOCUMENTS SHALL BE SHOWN ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. WHEN CODES AND STANDARDS ARE NOT | | | AVAILABLE OR APPLICABLE, AND SAID LAYOUT DOCUMENTS ARE | | | TO BE BASED ON ENGINEERING JUDGMENT, ANY REASONS AND | | | ASSUMPTIONS MADE TO DEVELOP THE FIRE PROTECTION CONCEPT | | | SHALL BE IDENTIFIED ON THE FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENTS. | | | (5) STRUCTURAL SUPPORT AND STRUCTURAL OPENINGS REQUIRED | | | BY THE FIRE PROTECTION SYSTEM SHALL BE SHOWN ON THE | | | FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS AND SHALL | | | BE REFERENCED ON STRUCTURAL ENGINEERING DOCUMENTS. | | | (6) WHEN LAYOUT DOCUMENTS CONTAIN MATERIAL DEVIATION | | | FROM THE ENGINEER OF RECORD'S FIRE PROTECTION SYSTEM | | | ENGINEERING DOCUMENT, SUCH LAYOUT DOCUMENTS ARE NOT | | | COMPLIANT UNLESS THEY ARE ACCOMPANIED BY REVISED | | | ENGINEERING DOCUMENTS MADE AND SEALED BY THE ENGINEER | | | OF RECORD FOR THE FIRE PROTECTION SYSTEM. | | | (7) REQUIREMENTS FOR ACTIVATION CONTROL SYSTEMS, | | | SEQUENCE, OPERATING PARAMETERS, INTERLOCKS, SAFETY | | | RELATED DEVICES, INDICATORS AND ALARMS, SHALL BE SHOWN | | | ON THE FIRE PROTECTION SYSTEM ENGINEERING DOCUMENTS, | | | UNLESS SHOWN ON OTHER RELATED DOCUMENTS. | | | (8) ANY INFORMATION DEEMED APPROPRIATE BY THE ENGINEER | | | OF RECORD TO ASSIST THE AUTHORITY HAVING JURISDICTION | | | IN UNDERSTANDING THE OWNER?S INTENDED USE AND PROPOSED | | | PROTECTION OF THE BUILDING OR FACILITY AND TO PROVIDE | | | SUFFICIENT DIRECTION TO THE INSTALLATION CONTRACTOR OR | | | OTHER INTERESTED PARTIES REGARDING THE LAYOUT OF THE | | | SYSTEM(S), SHALL BE INCLUDED IN THE FIRE PROTECTION | | | SYSTEM ENGINEERING DOCUMENTS. | | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.003, AMENDED | | | 4-2-2000, 6-26-01 | | | | | | 61G15-32.004 DESIGN OF WATER BASED FIRE PROTECTION | | | SYSTEMS. | | | (1) WATER BASED FIRE PROTECTION SYSTEMS INCLUDE, BUT | | | ARE NOT LIMITED TO, AUTOMATIC SPRINKLER SYSTEMS OF WET, | | | DRY, FINE WATER SPRAY (MIST), MANUAL, AND DELUGE VALVE | | | CONTROLLED TYPES, PUMPING SYSTEMS, STANDPIPES, FIRE | | | WATER MAINS AND DEDICATED FIRE PROTECTION WATER | | | SOURCES. | | | (2) TO ENSURE MINIMUM DESIGN QUALITY IN FIRE PROTECTION | | | SYSTEM ENGINEERING DOCUMENTS, SAID DOCUMENTS SHALL | | | INCLUDE AS A MINIMUM THE FOLLOWING INFORMATION WHEN | | | APPLICABLE: | | | (A) THE POINT OF SERVICE FOR THE FIRE PROTECTION WATER | | | SUPPLY AS DEFINED BY 633.021(18) F.S. | | | (B) APPLICABLE NFPA STANDARD TO BE APPLIED, OR IN THE | | | CASE WHERE NO SUCH STANDARD EXISTS, THE ENGINEERING | | | STUDY, JUDGMENTS, AND/OR PERFORMANCE BASED ANALYSIS AND | | | CONCLUSIONS. | | | (C) CLASSIFICATION OF HAZARD OCCUPANCY FOR EACH ROOM OR | | | AREA. | | | (D) DESIGN APPROACH, WHICH INCLUDES SYSTEM TYPE, | | | DENSITIES, DEVICE TEMPERATURE RATING, AND SPACING FOR | | | EACH SEPARATE 42 HAZARD OCCUPANCY. | | | (E) CHARACTERISTICS OF WATER SUPPLY TO BE USED, SUCH AS | | | MAIN SIZE AND LOCATION, WHETHER IT IS DEAD-END OR | | | CIRCULATING; AND IF DEAD-END, THE DISTANCE TO THE | | | NEAREST CIRCULATING MAIN, AS WELL AS ITS MINIMUM | | | DURATION AND RELIABILITY FOR THE MOST HYDRAULICALLY | | | DEMANDING DESIGN AREA. | | | (F) WHEN PRIVATE OR PUBLIC WATER SUPPLIES ARE USED, THE | | | FLOW TEST DATA, INCLUDING DATE AND TIME OF TEST, WHO | | | CONDUCTED TEST OR SUPPLIED INFORMATION, TEST ELEVATION, | | | STATIC GAUGE PRESSURE AT NO FLOW, FLOW RATE WITH | | | RESIDUAL GAUGE PRESSURE, HYDRANT BUTT COEFFICIENT, AND | | | LOCATION OF TEST IN RELATION TO THE HYDRAULIC POINT OF | | | SERVICE. | | | (G) VALVING AND ALARM REQUIREMENTS TO MINIMIZE | | | POTENTIAL FOR IMPAIRMENTS AND UNRECOGNIZED FLOW OF | | | WATER. | | | (H) MICROBIAL INDUCED CORROSION (MIC). THE ENGINEER OF | | | RECORD SHALL MAKE REASONABLE EFFORTS TO IDENTIFY WATER | | | SUPPLIES THAT COULD LEAD TO MICROBIAL INDUCED CORROSION | | | (MIC). SUCH EFFORTS MAY CONSIST OF DISCUSSIONS WITH THE | | | LOCAL WATER PURVEYOR AND/OR FIRE OFFICIAL, FAMILIARITY | | | WITH CONDITIONS IN THE LOCAL AREA, OR LABORATORY | | | TESTING OF WATER SUPPLIES. WHEN CONDITIONS ARE FOUND | | | THAT MAY RESULT IN MIC CONTAMINATION OF THE FIRE | | | PROTECTION PIPING, THE ENGINEER SHALL DESIGN CORRECTIVE | | | MEASURES. | | | (I) BACKFLOW PREVENTION AND METERING SPECIFICATIONS AND | | | DETAILS TO MEET LOCAL WATER PURVEYOR REQUIREMENTS | | | INCLUDING MAXIMUM ALLOWABLE PRESSURE DROP. | | | (J) QUALITY AND PERFORMANCE SPECIFICATIONS OF ALL YARD | | | AND INTERIOR FIRE PROTECTION COMPONENTS. | | | (3) CONTRACTOR SUBMITTALS WHICH DEVIATE FROM THE ABOVE | | | MINIMUM DESIGN PARAMETERS SHALL BE CONSIDERED MATERIAL | | | DEVIATIONS AND REQUIRE SUPPLEMENTAL ENGINEERING | | | APPROVAL AND DOCUMENTATION. | | | (4) IN THE EVENT THE ENGINEER OF RECORD PROVIDES MORE | | | INFORMATION AND DIRECTION THAN IS ESTABLISHED ABOVE, HE | | | OR SHE SHALL BE HELD RESPONSIBLE FOR THE TECHNICAL | | | ACCURACY OF THE WORK IN ACCORDANCE WITH APPLICABLE | | | CODES, STANDARDS, AND SOUND ENGINEERING PRINCIPLES. | | | SPECIFIC AUTHORITY 471.008, 471.033(2), FS | | | LAW IMPLEMENTED 471.005(7), 471.033(2), FS | | | HISTORY?NEW 5-19-93, FORMERLY 21H-32.004, AMENDED | | | 4-2-2000, 6-26-01, 7-12-05 | | | | | | | | | PLEASE REVIEW AND PROVIDES APPLICABLE SIGNED AND SEALED | | | EOR PLAN SHEETS OR WRITTEN NARRATIVE DOCUMENT | | | CONTAINING THE SAME INFO. SHOP DRAWINGS CAN THEN BE | | | PRODUCED, PREPARED AND SUBITTED SEPARATELY BY A FIRE | | | SPRINKLER CONTRACTOR. | | | | | | | | | | | | 9) SHEET A 8 & 9 - LIGHTWEIGHT TRUSS FLOORS AND TRUSSES | | | ARE INDICATED. | | | | | | PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR | | | STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | | ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT | | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES | | | HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A | | | MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND | | | 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR. | | | THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO | | | THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | | | | | | | 10) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | 11) THERE IS INSUFFICIENT INFORMATION SUBMITTED TO DO A | | | COMPLETE REVIEW OF THE LIFE SAFETY FEATURES AND | | | PROTECTION OF THIS PROJECT. | | | | | | ADDITIONAL COMMENTS MAY BE PROVIDED ON THE RE-SUBMITTAL | | | OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | 2017-05-04 14:49:00 | | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
3 |
Status |
P |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-20 |
Time |
10:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-20 |
Time |
10:45 |
Sent To |
|
|
| Notes |
| 2018-04-20 10:46:07 | | | | PLUMBING/GAS PROVISO: | | | 1. INDICATE ON THE PLAN WHICH DESIGN SPEC A OR B IS | | | BEING USED FOR THE BATHROOMS IN THE GROUND FLOOR UNITS. | | | PER FHA DESIGN MANUAL REQUIREMENT #7 | | | 2. PROVIDE DETAILS SHOWING THE MOUNTING HEIGHTS OF THE | | | BACKING FOR THE GRAB BARS IN THE BATHROOMS. PER FHA | | | DESIGN MANUAL REQUIREMENT #6 | | | 3. PROVIDE ON JOBSITE FOR INSPECTIONS THE MANUFACTURE | | | SPECIFICATIONS AND INSTALLATION GUIDES FOR THE TANKLESS | | | WATER HEATERS AND PRESSURE REGULATORS. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
2 |
Status |
F |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-26 |
Time |
18:01 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-26 |
Time |
18:01 |
Sent To |
|
|
| Notes |
| 2017-09-26 18:26:34 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | | | | 1. THE FIRST BRANCH OF GALV PIPE FEED 4 TANKLESS | | | HEATERS SHALL BE 1' . PER FBC FG TABLE 402.4(5) | | | | | | 2. THE TANKLES WATER HEATER SHALL BE MOUNTED 4' AWAY | | | FROM ALL OPENINGS PLEASE PROVIDE MANUFACTURE | | | INSTILLATION GUIDE TO VERIFY. PER WPB AMEN TO FBC | | | 107.2.1 | | | | | | 3. SUBMIT MANUFACTURER'S SPECIFICATION SHEETS FOR ALL | | | GAS REGULATORS TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | 4. PLEASE PROVIDE SEDIMENT TRAPS AT EACH APPLIANCE. PER | | | FBC FG 408.4 | | | | | | 5. SHOW SYSTEM PRESSURE ON RISER DIAGRAM FOR CLARITY IT | | | SHOWS A REGULATOR AFTER THE METER AND THEN ON AT EACH | | | APPLIANCE . WPB AMEND TO FBC 107.2.1 | | | | | | | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
G |
GAS REVIEW |
| Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-18 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-18 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2017-05-18 10:10:20 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | GAS COMMENTS: | | | | | | 1. THE FIRST SECTION OF PE PIPE SHALL BE 1 1/4" PER FBC | | | FUEL GAS TABLE 402.4(22) USING LONGEST LENGTH METHOD @ | | | 265'-8" WHICH WOULD BE ROUNDED TO 300' ON THE TABLE. | | | | | | 2. SUBMIT CALCULATIONS FOR COMBUSTION AIR PER THE | | | FBC-2014 FUEL GAS CODE SEC. 304. | | | | | | 3. SUBMIT A DETAIL SHOWING THE TYPE, LOCATION, SIZE AND | | | TERMINATION OF THE GAS VENTS PER FBC-2014 FUEL GAS CODE | | | SEC. 502 THRU 505. | | | | | | 4. SUBMIT MANUFACTURER?S SPECIFICATION SHEETS FOR ALL | | | GAS EQUIPMENT TO VERIFY COMPLIANCE WITH STANDARDS NFPA | | | 54, NFPA 58, AND FBC-2014 FUEL GAS SEC. 402.2 | | | | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-05-15 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-05-09 |
Time |
14:22 |
Sent To |
|
|
| Notes |
| 2018-05-09 14:23:36 | SENT TO JPEARSON DESK. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-04-27 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2018-04-27 |
Time |
15:21 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2018-04-26 |
Time |
15:16 |
Sent To |
|
|
| Notes |
| 2018-04-27 15:21:36 | IMPACT FEES GIVEN TO SKENNEDY, WILL REVIEW WHEN THEY | | | RESUBMIT. LEM | | 2018-04-27 15:16:42 | IMPACT FEES ROUTED TO JGOMEZ |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-04-21 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-04-20 |
Time |
09:49 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-04-05 |
Time |
12:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-10-12 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-10-12 |
Time |
16:15 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-08-31 |
Time |
10:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-19 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-05-19 |
Time |
10:01 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-04-27 |
Time |
15:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-05-15 |
|
|
Cont ID |
|
| Sent By |
skennedy |
Date |
2018-05-15 |
Time |
16:03 |
Rev Time |
0.00 |
| Received By |
skennedy |
Date |
2018-05-15 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-15 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-15 |
Time |
09:48 |
Sent To |
|
|
| Notes |
| 2017-05-15 09:52:07 | PLEASE NOTE THE DEMO-PERMIT 17010693 WAS ISSUED FOR THE | | | DEMOLITION OF 2 STRUCTURES, ON 3/21/2017 A FINAL WAS | | | CALLED IN AND PASSED. PLEASE CLOSE OUT THIS PERMIT BY | | | REQUESTING A CERTIFICATE OF COMPLETION. TAKE THE DEMO- | | | CERTIFICATE OF COMPLETION TO PALM BEACH COUNTY IMPACT | | | FEE OFFICE TO RECEIVE A CREDIT DUE BEFORE THE PAYMENT | | | OF IMPACT FEES. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | 2017-05-15 08:04:20 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED | | | 561-233-5025 FOR MORE INFORMATION | | | PLAN TO BE REVISED TO CLARIFY SCOPE PRIOR TO IMPACT FEE | | | ASSESSMENT (SEE BUILDING REVIEW) | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2018-04-17 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-04-17 |
Time |
09:27 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-04-17 |
Time |
09:27 |
Sent To |
|
|
| Notes |
| 2018-04-17 09:28:06 | MECHANICAL PROVISOS: | | | | | | 1) THE AC LAYOUT PLANS WILL REQUIRE REVISIONS TO MATCH | | | THE AIRFLOWS SHOWN IN THE AC CALCULATIONS. | | | 2) NO COMBUSTIBLE MATERIALS PERMITTED IN AC CLOSETS | | | USED AS OPEN RETURNS. CLOSED RETURNS- ALL DUCTS, AIR | | | HANDLERS, FILTER BOXES, BUILDING CAVITIES, AND ENCLOSED | | | SUPPORT PLATFORMS SHALL BE SEALED WITH APPROVED CLOSURE | | | SYSTEMS- SECTION C403.2.7.3 FBC-14 ENERGY CONSERVATION. | | | 3) MANUFACTURER'S SPECIFICATIONS FOR THE AC SYSTEMS, | | | DRYERS, WATER HEATERS, RANGES, AND RANGE HOODS SHALL BE | | | ONSITE AT TIME OF INSPECTION | | | | | | CCOLE- 4/17/18 | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-19 |
Time |
15:58 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-19 |
Time |
14:23 |
Sent To |
|
|
| Notes |
| 2017-09-19 16:27:34 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17041276 | | | 9/19/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) AC AND ENERGY CALCULATIONS HAVE BEEN SUBMITTED AS | | | REQUESTED, HOWEVER OF THE FOUR END UNITS ON THE 1ST AND | | | 2ND FLOOR, CALCULATIONS FOR ONLY TWO OF THE UNITS HAVE | | | BEEN SUBMITTED. | | | | | | 2) THE SUMMER AND WINTER OUTSIDE DRYBULB TEMPERATURES | | | INDICATED ON THE AC CALCULATIONS AT 94 AND 35 DEGREES F | | | ARE NOT IN COMPLIANCE WITH THE ACCA/ASHRAE STANDARD | | | WHICH SPECIFIES 91 AND 45 DEGREES. | | | | | | 3) THE FRONT DOOR DIRECTIONAL ORIENTATIONS SHOWN ON THE | | | PLANS DO NOT MATCH THE AC CALCULATIONS WHICH ARE | | | INDICATING SW FOR ALL OF THE UNITS. | | | | | | 4) SHEET A-14: 2ND REQUEST FOR COMBUSTION AIR | | | CALCULATIONS AND VENTING PLANS FOR THE GAS DRYERS. | | | | | | 5) A-14: 2ND REQUEST FOR COMPLETE AC EQUIPMENT | | | SCHEDULES THAT INDICATE TOTAL SUPPLY CFMS, EFFICIENCY | | | RATINGS, AND ELECTRICAL HEATING DATA. PLEASE NOTE THAT | | | THE SCHEDULE IS INDICATING OFFICE/LAUNDRY HOWEVER THERE | | | IS NO OFFICE ON THE PLANS- PLEASE CORRECT. | | | | | | 6) EXHAUST VENTILATION IS REQUIRED FOR THE KITCHENS AND | | | THE COOKING APPLIANCES., HOWEVER NO INFORMATION HAS | | | BEEN PROVIDED ON THE PLANS. REFER TO SECTION 505 AND | | | SHOW COMPLIANCE ON THE PLANS. | | | | | | 7) THE AC CLOSET DOORS SHALL BE NON-COMBUSTIBLE IN | | | COMPLIANCE WITH SECTION C403.2.7.2 FBC-14 ENERGY | | | CONSERVATION AND SECTION 602 FBC-14 MECHANICAL. | | | | | | 8) 2ND REQUEST WIND LOAD ENGINEERING FOR INSTALLATION | | | OF THE EXTERIOR CONDENSERS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-02 |
Time |
14:44 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-02 |
Time |
14:44 |
Sent To |
|
|
| Notes |
| 2017-05-02 15:06:11 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17041276 | | | 5/2/17 | | | | | | 1) THE MECHANICAL PLANS ARE INCOMPLETE. PLEASE PROVIDE | | | THE FOLLOWING: | | | | | | A) AC COOLING HEATING CALCULATIONS- SECTION C403.2.1 | | | FBC-14 ENERGY CONSERVATION. | | | B) ENERGY CALCULATIONS- SECTIONS C101.3, C101.5, AND | | | C401.2 FBC-14 ENERGY CONSERVATION. | | | C) MINIMUM VENTIALTION CALCULATIONS FOR ALL OCCUPIED | | | ROOMS AND SPACES. PROVIDE A TABLE THAT INCLUDES THE | | | REQUIRED AND PROVIDED CFMS OF OUTSIDE AIR- TABLE 403.3 | | | FBC-14 MECHANICAL. | | | D) EXHAUST VENTILATION CALCULATIONS FOR THE RESTROOMS- | | | TABLE 403.3 | | | E) COMBUSTION AIR CALCULATIONS AND VENTING PLANS FOR | | | THE GAS DRYERS - SECTION 304 AND 501.1 FBC-14 ENERGY | | | CONSERVATION. | | | F) COMPLETE DUCT LAYOUT AND AIR DISTRIBUTION PLANS | | | SHOWING DUCT SIZES, DIFFUSER AND RETURN GRILL SIZES, | | | TRANSFER GRILLS OR DUCTS WHERE REQUIRED, AND CFM'S AT | | | EACH DEVICE. | | | G) COMPLETE AC EQUIPMENT SCHEDULES THAT INDICATE THE | | | MAKES AND MODELS OF THE COMPONENTS, COOLING AND HEATING | | | CAPACITIES, SUPPLY CFMS, EFFICIENCY RATINGS, AND | | | ELECTRICAL DATA. | | | H) WIND LOAD ENGINEERING FOR INSTALLATION OF THE | | | EXTERIOR CONDENSERS. | | | | | | 2) SHEET A-14: THE PLAN APPEARS TO SHOW AN AIR HANDLER | | | IN THE ATTIC ABOVE THE GREAT ROOM WHICH IS PROHIBITED | | | PER SECTION C403.2.7.6 FBC-14 ENERGY COMPLIANCE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2018-04-20 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-04-20 |
Time |
10:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-04-20 |
Time |
10:25 |
Sent To |
|
|
| Notes |
| 2018-04-20 10:29:00 | | | | PLUMBING/GAS PROVISO: | | | 1. INDICATE ON THE PLAN WHICH DESIGN SPEC A OR B IS | | | BEING USED FOR THE BATHROOMS IN THE GROUND FLOOR UNITS. | | | PER FHA DESIGN MANUAL REQUIREMENT #7 | | | 2. PROVIDE DETAILS SHOWING THE MOUNTING HEIGHTS OF THE | | | BACKING FOR THE GRAB BARS IN THE BATHROOMS. PER FHA | | | DESIGN MANUAL REQUIREMENT #6 | | | 3. PROVIDE ON JOBSITE FOR INSPECTIONS THE MANUFACTURE | | | SPECIFICATIONS AND INSTALLATION GUIDES FOR THE TANKLESS | | | WATER HEATERS AND PRESSURE REGULATORS. PER WPB AMEND TO | | | FBC 107.2.1 | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-26 |
Time |
17:20 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-26 |
Time |
17:20 |
Sent To |
|
|
| Notes |
| 2017-09-26 18:00:43 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: 2ND REQUEST NOT COMPLIED A NARRATIVE | | | LISTING THE ORIGINAL REVIEW COMMENT NUMBER WITH A | | | DESCRIPTION OF THE CHANGES MADE AND IDENTIFYING THE | | | SHEET OR SPECIFICATION PAGE WHERE THE CHANGE CAN BE | | | FOUND WILL HELP EXPEDITE THE REVIEW. | | | | | | | | | 2. THE PLAN DOES NOT INDICATE WHAT TYPE OF OCCUPANCY | | | THIS PROJECT IS IF IT IS GOING TO BE MULTI FAMILY | | | RESIDENTIAL AN R3 OR R4 THE GROUND FLOOR UNIT WILL HAVE | | | TO COMPLY WITH THE FHA DESIGN MANUAL. PLEASE PROVIDE | | | TYPE OF OCCUPANCY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE BATHROOMS IN THE GREAT ROOM IS A COMMON AREA AND | | | SHALL COMPLY WITH THE FBC ACC 603,604, 606, 609 | | | | | | 4. THE TRANSFER SHOWER IN BATHROOM #1 IN UNIT 1A AND 1B | | | SHAL BE 36" X 36". PER FBC ACC 608.2.1 | | | | | | 5. THE GRAB BARS FOR THE ROLL IN SHOWER IN BATHROOM #1 | | | IN UNIT 1C SHALL COMPLY WITH. PER FBC ACC 608.3.2 | | | | | | 6. SHOW IN ALL ACCESSIBLE BATHROOMS THE CLEAR FLOOR | | | SPACE FOR THE TOILET , LAVATORY AND SHOWER. PER FBC ACC | | | 608.2.1 ,608.2.2.1 ,606.2,604.3.1 | | | | | | 7. SHOW HEIGHT DIMENSIONS FOR SHOWER SEATS AND | | | CONTROLS. PER FBC ACC 608.5.1 , 610.3 , 608.5.2 , | | | 610.3.2, 610.3.1 | | | | | | 8. PLEASE LABEL THE SOILSTACKS ON PLAN VIEW TO COINCIDE | | | WITH TAGS ON RISER DIAGRAM. PER WPB AMEND TO FBC | | | 107.2.1, | | | | | | 9. PLEASE PROVIDE WATER RISER DIAGRAM. WPB AMEND TO FBC | | | 107.3.5.1.3(13) | | | | | | 10. PLEASE PROVIDE COMPLETE SANITARY RISER DIAGRAM. WPB | | | AMEND TO FBC 107.3.5.1.3(13) | | | | | | 11. BRANCH DRAIN FOR WASHING MACHINE SHALL BE 3". PER | | | FBC PL 406.2 | | | | | | NEW COMMENTS: | | | | | | 1. GRAB BARS SHALL BE ABOVE THE FINISH FLOOR MEASURED | | | TO THE TOP OF THE GRIPPING SURFACE. PER FBC ACC 609.4 | | | | | | 2. SHOWER SPRAY UNIT SHALL BE INSTALLED ON THE SIDE | | | WALL OPPOSITE THE SEAT 38 INCHES MINIMUM AND 48 INCHES | | | MAXIMUM ABOVE THE SHOWER FLOOR AND SHALL BE LOCATED ON | | | THE CONTROL WALL 15 INCHES (380 MM) MAXIMUM FROM THE | | | CENTERLINE OF THE SEAT TOWARD THE SHOWER OPENING. PER | | | FBC ACC 608.5.1 | | | | | | 3. THE SOIL STACKS FROM SECOND FLOOR SHALL CONNECT TO | | | BUILDING DRAIN DOWN STREAM OF FIRST FLOOR BATHROOM | | | GROUP. PER FBC PL 912.1 | | | | | | 4. A CLEANOUT SHALL BE PROVIDED AT THE BASE OF EACH | | | WASTE OR SOIL STACK. PER FBC PL 708.3.4 | | | | | | 6. A LENT TRAP IS REQUIRED FOR THE WASHING MACHINES. | | | PER FBC PL 1003.6 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-18 |
Time |
09:53 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-17 |
Time |
17:30 |
Sent To |
|
|
| Notes |
| 2017-05-18 10:05:08 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. ON THE APPLICATION DESCRIPTION OF WORK IT STATES A | | | NEW BUILDING BUT ON THE PLANS IN THE TITLE BLOCK IT | | | STATES IT IS AN INTERIOR REMODEL PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 2. THE PLAN DOES NOT INDICATE WHAT TYPE OF OCCUPANCY | | | THIS PROJECT IS IF IT IS GOING TO BE MULTI FAMILY | | | RESIDENTIAL AN R3 OR R4 THE GROUND FLOOR UNIT WILL HAVE | | | TO COMPLY WITH THE FHA DESIGN MANUAL. PLEASE PROVIDE | | | TYPE OF OCCUPANCY. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. THE BATHROOMS IN THE GREAT ROOM IS A COMMON AREA AND | | | SHALL COMPLY WITH THE FBC ACC 603,604, 606, 609 | | | | | | 4. THE TRANSFER SHOWER IN BATHROOM #1 IN UNIT 1A AND 1B | | | SHAL BE 36" X 36". PER FBC ACC 608.2.1 | | | | | | 5. THE GRAB BARS FOR THE ROLL IN SHOWER IN BATHROOM #1 | | | IN UNIT 1C SHALL COMPLY WITH. PER FBC ACC 608.3.2 | | | | | | 6. SHOW IN ALL ACCESSIBLE BATHROOMS THE CLEAR FLOOR | | | SPACE FOR THE TOILET , LAVATORY AND SHOWER. PER FBC ACC | | | 608.2.1 ,608.2.2.1 ,606.2,604.3.1 | | | | | | 7. SHOW HEIGHT DIMENSIONS FOR SHOWER SEATS AND | | | CONTROLS. PER FBC ACC 608.5.1 , 610.3 , 608.5.2 , | | | 610.3.2, 610.3.1 | | | | | | 8. PLEASE LABEL THE SOILSTACKS ON PLAN VIEW TO COINCIDE | | | WITH TAGS ON RISER DIAGRAM. PER WPB AMEND TO FBC | | | 107.2.1, | | | | | | 9. PLEASE PROVIDE WATER RISER DIAGRAM. WPB AMEND TO FBC | | | 107.3.5.1.3(13) | | | | | | 10. PLEASE PROVIDE COMPLETE SANITARY RISER DIAGRAM. WPB | | | AMEND TO FBC 107.3.5.1.3(13) | | | | | | 11. BRANCH DRAIN FOR WASHING MACHINE SHALL BE 3". PER | | | FBC PL 406.2 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-06-20 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-06-20 |
Time |
16:23 |
Sent To |
|
|
| Notes |
| 2018-06-20 16:23:22 | PROVIDE APPROVED SITE PLAN WITH PLAN SET | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2018-05-29 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2018-05-29 |
Time |
16:26 |
Sent To |
|
|
| Notes |
| 2018-04-19 16:26:24 | APPROVED AS MULTIFAMILY APARTMENT | | | BUILDINGS | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-10-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-09-27 |
Time |
15:53 |
Sent To |
|
|
| Notes |
| 2017-10-06 14:07:33 | 1.) APPLICATION REQUIRES LEVEL 1 SITE PLAN REVIEW (PER | | | SEC. 94-35(D) | | | | | | PAUL GREILICH, SENIOR PLANNER | | | 561-822-1443 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-05-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
pgreilic |
Date |
2017-05-15 |
Time |
15:36 |
Sent To |
|
|
| Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |