Plan Review Details - Permit 17041265
Plan Review Stops For Permit 17041265
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date   Cont ID  
Sent By   Date 2017-06-22 Time   Rev Time 0.00
Received By jwitmer Date 2017-06-22 Time 16:26 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2017-05-06 Cont ID  
Sent By jwitmer Date 2017-05-06 Time 10:30 Rev Time 0.00
Received By jwitmer Date 2017-05-06 Time 10:02 Sent To  
Notes
2017-05-06 10:30:212014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17041265
 ADD: 1555 PALM BEACH LAKES BLVD. SUITE 200
 CONT: FISHER CONTRACTING
 TEL: 561-691-4716
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. MAY 06/ 2017
 ACTION: DENIED
  
 1) BUILDING PROVISO:
 SHEET A1 THE BREAK ROOM INDICATES A COUNTER AND SINK.
 NO DETAILS PROVIDED.
 SINK IS TO COMPLY WITH THE 2014 FBC-ACCESS. CODE
 SECTION 606.3. HEIGHT.
 LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT
 OF THE HIGHER OF THE RIM
 OR COUNTER SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE
 FINISH FLOOR OR
 GROUND.
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
  
 E-MAIL: [email protected]
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-06-20 Cont ID  
Sent By jleahy Date 2017-06-20 Time 14:28 Rev Time 0.00
Received By jleahy Date 2017-06-20 Time 14:28 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-05-12 Cont ID  
Sent By jleahy Date 2017-05-12 Time 08:59 Rev Time 0.00
Received By jleahy Date 2017-05-11 Time 15:50 Sent To  
Notes
2017-05-11 15:50:41JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 NEED THE FOLLOWING INFORMATION PRIOR TO FINAL
 ELECTRICAL INSPECTION.
  
 C405.5 INTERIOR LIGHTING POWER REQUIREMENTS
 (PRESCRIPTIVE).
 A BUILDING COMPLIES WITH THIS SECTION IF ITS TOTAL
 CONNECTED LIGHTING POWER CALCULATED UNDER SECTION
 C405.5.1
 IS NO GREATER THAN THE INTERIOR LIGHTING POWER
 CALCULATED UNDER SECTION C405.5.2.
  
 C405.5.1 TOTAL CONNECTED INTERIOR LIGHTING POWER.
 THE TOTAL CONNECTED INTERIOR LIGHTING POWER (WATTS)
 SHALL BE THE SUM OF THE WATTS OF ALL INTERIOR LIGHTING
 EQUIPMENT
 AS DETERMINED IN ACCORDANCE WITH SECTIONS C405.5.1.1
 THROUGH C405.5.1.4.
  
 C405.2 LIGHTING CONTROLS (MANDATORY).
 LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS
 SPECIFIED IN SECTIONS C405.2.1, C405.2.2, C405.2.3 AND
 C405.2.4

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-06-26 Cont ID  
Sent By scaldero Date 2017-06-26 Time 14:13 Rev Time 0.00
Received By scaldero Date 2017-06-26 Time 14:13 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-05-02 Cont ID  
Sent By scaldero Date 2017-05-02 Time 09:59 Rev Time 0.00
Received By scaldero Date 2017-05-02 Time 09:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2017-08-10 Time   Rev Time 0.00
Received By lmarchan Date 2017-08-08 Time 11:20 Sent To  
Notes
2017-08-09 11:20:24RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2017-06-28 Time   Rev Time 0.00
Received By lmarchan Date 2017-06-14 Time 15:52 Sent To  
Notes
2017-06-14 15:52:08B04

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-12 Cont ID  
Sent By jleahy Date 2017-05-12 Time 08:59 Rev Time 0.00
Received By jleahy Date 2017-04-27 Time 10:57 Sent To  
Notes
2017-04-28 10:57:16B01

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2017-05-06 Time   Rev Time 0.00
Received By jwitmer Date 2017-05-06 Time 10:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-08-10 Cont ID  
Sent By ccole Date 2017-08-10 Time 08:23 Rev Time 0.00
Received By ccole Date 2017-08-10 Time 08:04 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-06-22 Cont ID  
Sent By ccole Date 2017-06-22 Time 07:11 Rev Time 0.00
Received By ccole Date 2017-06-21 Time 17:28 Sent To  
Notes
2017-06-22 07:18:481ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17041265
 6/22/17
  
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE
 AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL
 ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL.
 PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED CFMS OF OUTDOOR AIR.
  
 2) PROVIDE MECHANICAL DEMOLTION AND ALTERATION PLANS.
 IT APPEARS THAT THE REMOVAL OF THE ROOM PATRTITIONS TO
 ENLARGE THE BREAK AND CONFERENCE ROOMS WILL RESULT IN
 CHANGES TO THE AIR DISTRIBUTION COMPONENTS. PLEASE SHOW
 THOSE CHANGES ON THE PLAN.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-06-21 Cont ID  
Sent By gjohnson Date 2017-06-21 Time 15:16 Rev Time 0.00
Received By gjohnson Date 2017-06-21 Time 12:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-05-08 Cont ID  
Sent By gjohnson Date 2017-05-08 Time 17:25 Rev Time 0.00
Received By gjohnson Date 2017-05-08 Time 15:56 Sent To  
Notes
2017-05-08 17:28:501ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. PROVIDE SCOPE OF WORK FOR PLUMBING , IS BREAK ROOM
 SINK EXISTING , IS IT BEING CHANGED, OR IS ADDING THE
 TANKLESS HEATER THE ONLY PLUMBING WORK BEING DONE
 PLEASE CLARIFY. PER WPB AMEND TO FBC PL 107.2.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  