| Plan Review Stops For Permit 17041265 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-22 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-06-22 |
Time |
16:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-05-06 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-06 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-06 |
Time |
10:02 |
Sent To |
|
|
| Notes |
| 2017-05-06 10:30:21 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17041265 | | | ADD: 1555 PALM BEACH LAKES BLVD. SUITE 200 | | | CONT: FISHER CONTRACTING | | | TEL: 561-691-4716 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: SAT. MAY 06/ 2017 | | | ACTION: DENIED | | | | | | 1) BUILDING PROVISO: | | | SHEET A1 THE BREAK ROOM INDICATES A COUNTER AND SINK. | | | NO DETAILS PROVIDED. | | | SINK IS TO COMPLY WITH THE 2014 FBC-ACCESS. CODE | | | SECTION 606.3. HEIGHT. | | | LAVATORIES AND SINKS SHALL BE INSTALLED WITH THE FRONT | | | OF THE HIGHER OF THE RIM | | | OR COUNTER SURFACE 34 INCHES (865 MM) MAXIMUM ABOVE THE | | | FINISH FLOOR OR | | | GROUND. | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | | | | E-MAIL: [email protected] | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-06-20 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-06-20 |
Time |
14:28 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-06-20 |
Time |
14:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-12 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-11 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2017-05-11 15:50:41 | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6713 | | | [email protected] | | | | | | | | | NEED THE FOLLOWING INFORMATION PRIOR TO FINAL | | | ELECTRICAL INSPECTION. | | | | | | C405.5 INTERIOR LIGHTING POWER REQUIREMENTS | | | (PRESCRIPTIVE). | | | A BUILDING COMPLIES WITH THIS SECTION IF ITS TOTAL | | | CONNECTED LIGHTING POWER CALCULATED UNDER SECTION | | | C405.5.1 | | | IS NO GREATER THAN THE INTERIOR LIGHTING POWER | | | CALCULATED UNDER SECTION C405.5.2. | | | | | | C405.5.1 TOTAL CONNECTED INTERIOR LIGHTING POWER. | | | THE TOTAL CONNECTED INTERIOR LIGHTING POWER (WATTS) | | | SHALL BE THE SUM OF THE WATTS OF ALL INTERIOR LIGHTING | | | EQUIPMENT | | | AS DETERMINED IN ACCORDANCE WITH SECTIONS C405.5.1.1 | | | THROUGH C405.5.1.4. | | | | | | C405.2 LIGHTING CONTROLS (MANDATORY). | | | LIGHTING SYSTEMS SHALL BE PROVIDED WITH CONTROLS AS | | | SPECIFIED IN SECTIONS C405.2.1, C405.2.2, C405.2.3 AND | | | C405.2.4 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-06-26 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2017-06-26 |
Time |
14:13 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2017-06-26 |
Time |
14:13 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-05-02 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2017-05-02 |
Time |
09:59 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2017-05-02 |
Time |
09:59 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-10 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-08 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2017-08-09 11:20:24 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-14 |
Time |
15:52 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-12 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-04-27 |
Time |
10:57 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-05-06 |
Time |
|
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-06 |
Time |
10:02 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-08-10 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-10 |
Time |
08:23 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-10 |
Time |
08:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-06-22 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-22 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-21 |
Time |
17:28 |
Sent To |
|
|
| Notes |
| 2017-06-22 07:18:48 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17041265 | | | 6/22/17 | | | | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE | | | AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL | | | ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL. | | | PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | | PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 2) PROVIDE MECHANICAL DEMOLTION AND ALTERATION PLANS. | | | IT APPEARS THAT THE REMOVAL OF THE ROOM PATRTITIONS TO | | | ENLARGE THE BREAK AND CONFERENCE ROOMS WILL RESULT IN | | | CHANGES TO THE AIR DISTRIBUTION COMPONENTS. PLEASE SHOW | | | THOSE CHANGES ON THE PLAN. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-21 |
Time |
15:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-21 |
Time |
12:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-08 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-08 |
Time |
17:25 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-08 |
Time |
15:56 |
Sent To |
|
|
| Notes |
| 2017-05-08 17:28:50 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE SCOPE OF WORK FOR PLUMBING , IS BREAK ROOM | | | SINK EXISTING , IS IT BEING CHANGED, OR IS ADDING THE | | | TANKLESS HEATER THE ONLY PLUMBING WORK BEING DONE | | | PLEASE CLARIFY. PER WPB AMEND TO FBC PL 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|