Plan Review Details - Permit 17041264
| Plan Review Stops For Permit 17041264 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-17 |
Time |
16:33 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-17 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-16 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-16 |
Time |
09:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-05-30 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-05-30 |
Time |
14:48 |
Sent To |
|
|
| Notes |
| 2017-05-30 14:55:38 | 1. PROVIDE ELECTRICAL PERMIT APPLICATION WITH SCOPE OF | | | WORK AND VALUE LISTED. FBC 105.1, FBC 109.3 | | | 2. EMERGENCY AND EXIT LIGHTING SHALL BE FED FROM THE | | | BRANCH CIRCUIT OF THE NORMAL LIGHTING IN THE AREA. | | | PROVIDE CORRECTION SHOWING CIRCUITS FOR THESE ITEMS. | | | NEC 700.12(F) | | | 3. CIRCUIT FOR NEW PROJECTOR AND SCREEN IS NOT | | | INDICATED OR INCLUDED IN PANEL SCHEDULE. PROVIDE | | | CORRECTION WITH CONDUCTOR AND BREAKER SIZING. NEC | | | 408.4, NEC 210.19 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-05-02 |
|
|
Cont ID |
|
| Sent By |
scaldero |
Date |
2017-05-02 |
Time |
09:58 |
Rev Time |
0.00 |
| Received By |
scaldero |
Date |
2017-05-02 |
Time |
09:58 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-16 |
Time |
09:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-14 |
Time |
16:36 |
Sent To |
|
|
| Notes |
| 2017-06-16 09:08:32 | PLACED IN "TO BE PROCESSED" BOX | | 2017-06-14 16:36:36 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-05-30 |
Time |
14:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-05-30 |
Time |
14:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
N |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-17 |
Time |
12:12 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-17 |
Time |
11:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-06-15 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-15 |
Time |
09:55 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-15 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-03 |
Time |
09:02 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-03 |
Time |
09:02 |
Sent To |
|
|
| Notes |
| 2017-05-03 09:09:30 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17041264 | | | 5/2/17 | | | | | | 1) REFER TO SECTIONS 809.1 & 809.2 FBC-14 EXISTING | | | BUILDING CODE AND PROVIDE MINIMUM VENTILATION | | | CALCULATIONS FOR ALL ROOMS AND SPACES INVOLVED IN THE | | | ALTERATION- SEE TABLE 403.3 FBC-14 MECHANICAL. PROVIDE | | | A SCHEDULE THAT INDICATES THE REQUIRED AND PROVIDED | | | CFMS OF OUTDOOR AIR. | | | | | | 2) SHOW COMPLIANCE WITH C403.2.7.5 FBC-14 ENERGY | | | CONSERVATION CODE FOR AIR DISTRIBUTION, AND DUCT SYSTEM | | | SIZING. | | | | | | 3) SUBMIT A MECHANICAL SUB-PERMIT APPLICATION FOR | | | ALTMAN BROTHERS, OR PROVIDE A SHOP DRAWING STAMP ON THE | | | PLANS FROM THE ARCHITECT OF RECORD- PLEASE SEE SECTION | | | 105.3.1.2 WPB AMENDMENTS TO THE FBC. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
|