| Plan Review Stops For Permit 17041259 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-07-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-12 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-12 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-06 |
Time |
08:01 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-06 |
Time |
07:28 |
Sent To |
E |
|
| Notes |
| 2017-06-06 08:05:20 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. COMMENTS FROM 1ST REVIEW HAVE NOT BEEN ADDRESSED. | | | | | | ADVISORY | | | | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-05-10 |
Time |
11:14 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-05-10 |
Time |
11:14 |
Sent To |
E |
|
| Notes |
| 2017-05-10 11:18:23 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PROVIDE DESIGN WIND LOADS FOR PROPOSED SIGN. | | | 2. PROVIDE SECTION VIEW OF EXISTING EXTERIOR WALL. | | | 3. PROVIDE ATTACHMENT DETAIL FOR PROPOSED SIGN TO | | | EXISTING WALL. | | | | | | FBC 107.3.5.1.1(8) - PROVIDE WIND DESIGN LOADS/DESIGN | | | PRESSURES PURSUANT TO FBC-CHAPTER 16 | | | | | | 1603.1.4 WIND DESIGN DATA. | | | THE FOLLOWING INFORMATION RELATED TO WIND LOADS SHALL | | | BE SHOWN, REGARDLESS OF WHETHER WIND LOADS GOVERN THE | | | DESIGN OF THE LATERAL FORCE-RESISTING SYSTEM OF THE | | | STRUCTURE: | | | 1. ULTIMATE DESIGN WIND SPEED, VULT, (3-SECOND GUST), | | | MILES PER HOUR (KM/HR) AND NOMINAL DESIGN WIND SPEED, | | | VASD, AS DETERMINED IN ACCORDANCE WITH SECTION | | | 1609.3.1. | | | 2. RISK CATEGORY. | | | 3. WIND EXPOSURE. APPLICABLE WIND DIRECTION IF MORE | | | THAN ONE WIND EXPOSURE IS UTILIZED. | | | 4. APPLICABLE INTERNAL PRESSURE COEFFICIENT. | | | 5. DESIGN WIND PRESSURES TO BE USED FOR EXTERIOR | | | COMPONENT AND CLADDING MATERIALS NOT SPECIFICALLY | | | DESIGNED BY THE REGISTERED DESIGN PROFESSIONAL | | | RESPONSIBLE FOR THE DESIGN OF THE STRUCTURE, PSF (KN/ | | | M2). | | | | | | FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. | | | CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN | | | UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE | | | OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE | | | AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT | | | IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND | | | RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS | | | DETERMINED BY THE BUILDING OFFICIAL. | | | | | | FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL | | | INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING | | | DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON | | | RESPONSIBLE FOR THE DESIGN. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-07-12 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-07-12 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-07-12 |
Time |
07:38 |
Sent To |
B |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-06-06 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-06-06 |
Time |
08:59 |
Sent To |
|
|
| Notes |
| 2017-06-06 08:59:39 | SEE COMMENTS FROM 5/10/17 REVIEW JLEAHY |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-10 |
Time |
11:29 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-10 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2017-05-10 11:46:39 | NO ELECTRIC SHOWN FOR SIGN. NEED DETAIL OF SIGN | | | ELECTRIC AND BRANCH CKT | | | | | | JAKE LEAHY | | | 561-805-6713 |
|
|
| Review Stop |
HIST |
HISTORICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
destabro |
Date |
2017-05-25 |
Time |
14:14 |
Rev Time |
0.00 |
| Received By |
destabro |
Date |
2017-05-25 |
Time |
14:14 |
Sent To |
B |
|
| Notes |
| 2017-05-25 14:15:27 | 5/25/2017 - WITH ONLY TWO ANCHOR SITES, INSTALLATION | | | WILL HAVE MINIMAL IMPACT ON THE HISTORIC FABRIC OF THIS | | | BUILDING. SIGN MEETS DESIGN GUIDELINES FOR HISTORIC | | | BUIDLINGS. DLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-07-12 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-12 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-10 |
Time |
14:50 |
Sent To |
|
|
| Notes |
| 2017-07-11 14:50:52 | RESUB ROUTED TO JLEAHY |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-06-06 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-06-06 |
Time |
08:59 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-22 |
Time |
09:52 |
Sent To |
|
|
| Notes |
| 2017-05-23 09:52:40 | RESUB ROUTED TO KMARTIN VIA ZONING INBOX |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-05-23 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-04-27 |
Time |
14:45 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-05-26 |
Time |
|
Rev Time |
0.00 |
| Received By |
kmartin |
Date |
2017-05-26 |
Time |
11:06 |
Sent To |
B |
|
| Notes |
| 2017-05-26 11:08:03 | PROVISO | | | 1. SIGN BAND WILL NOT BE PERMITTED WITH A VERTICAL | | | SIGN. EXISTING SIGN SHALL BE REMOVED BEFORE THIS SIGN | | | IS INSTALLED. | | | | | | FOR MORE INFO, PLEASE CONTACT KEVIN MARTIN, URBAN | | | DESIGN PLANNER AT [email protected]. | | 2017-05-23 14:06:07 | ROUTED TO KEVIN MARTIN |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-05-23 |
Time |
09:51 |
Rev Time |
0.00 |
| Received By |
kmartin |
Date |
2017-05-04 |
Time |
10:03 |
Sent To |
B |
|
| Notes |
| 2017-05-04 10:09:09 | 1. VERTICAL SIGNS SHALL NOT EXCEED 10 FEET IN VERTICAL | | | DIMENSION. | | | 2. WIDTH DIMENSION MUST BE SHOWN ON DRAWINGS, SHALL NOT | | | EXCEED TWO FEET. | | | 3. THE DISTANCE BETWEEN THE SIGN AND THE FA?ADE EDGE | | | SHALL BE SHOWN, SHALL BE AT LEAST TWO FEET. | | | 4. SIGN BAND WILL NOT BE PERMITTED WITH A VERTICAL | | | SIGN. FOR MORE INFO, PLEASE CONTACT KEVIN MARTIN, URBAN | | | DESIGN PLANNER AT [email protected]. |
|
|