| Plan Review Stops For Permit 17041227 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-05 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-05 |
Time |
11:35 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-03 |
Time |
12:43 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-03 |
Time |
11:20 |
Sent To |
|
|
| Notes |
| 2018-01-03 12:36:43 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17041227 | | | ADD: 5015 GEORGIA AVE. | | | CONT: GRUBER HALL CORP. | | | TEL: 561-662-3377 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 4TH REVIEW | | | DATE: 1/3/2018 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) COMPLIED | | | | | | 3-7) COMPLIED. | | | | | | 8A) COMPLIED | | | | | | 8B) COMPLIED | | | | | | 9) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 10) NEW COMMENT. ONLY ONE SET OF PLANS HAS BEEN | | | RETURNED FOR REVIEW. PLEASE RETURN THE SECOND SET OF | | | PLANS WHEN YOU RESUBMIT FOR REVIEW. FBC 107.1 SUBMITTAL | | | DOCUMENTS. | | | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | 561-805-6718 [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-12-14 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-14 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-14 |
Time |
11:45 |
Sent To |
|
|
| Notes |
| 2017-12-14 13:01:12 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17041227 | | | ADD: 5015 GEORGIA AVE. | | | CONT: GRUBER HALL CORP. | | | TEL: 561-662-3377 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 3RD REVIEW | | | DATE: 12/14/2017 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) 3RD REQUEST. MISSING SOILS REPORTS? 2014 FBC-B | | | 1803.5.2 QUESTIONABLE SOIL. SUBMIT (2) SIGNED AND | | | SEALED ORIGINAL SOILS REPORTS. | | | | | | 3-7) COMPLIED. | | | | | | 8A) COMPLIED | | | | | | 8B) COMPLIED | | | | | | 9) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | | | | ART LANGE BUILDING PLANS EXAMINER | | | DEVELOPMENT SERVICES DEPARTMENT | | | 401 CLEMATIS STREET | | | WEST PALM BEACH, FL 33402 | | | 561-805-6718 [email protected] | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-08-16 |
Time |
16:39 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-08-16 |
Time |
15:36 |
Sent To |
|
|
| Notes |
| 2017-08-16 16:39:16 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17041227 | | | ADD: 5015 GEORGIA AVE. | | | CONT: GRUBER HALL CORP. | | | TEL: 561-662-3377 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 2ND REVIEW | | | DATE: WED. 16/ 2017 | | | ACTION: DENIED | | | | | | 1) COMPLIED. | | | | | | 2) 2ND REQUEST. MISSING SOILS REPORTS? 2014 FBC-B | | | 1803.5.2 QUESTIONABLE SOIL. SUBMIT (2) SIGNED AND | | | SEALED ORIGINAL SOILS REPORTS. | | | | | | 3-7) COMPLIED. | | | | | | 8A) 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS, | | | 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT | | | OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005, | | | RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS | | | OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT | | | APPROVALS: | | | (31)(G) PRE-ENGINEERED A/C ROOF TOP STANDS ? ONLY ONE | | | SUBMITTED. (2) REQUIRED. | | | | | | 8B) THE ROOF TOP A/C STAND PRODUCT APPROVAL A FLORIDA | | | APPROVAL FL7215-R4 WAS SUBMITTED, NOT REVIEWED BY THE | | | DESIGNER OF RECORD. NEITHER THE CONTRACTOR NOR THE | | | DESIGNER OF RECORD HAVE FOLLOWED THE PRODUCT APPROVAL | | | IN CALCULATING THE AREA OF THE ROOF TOP COMPRESSORS, | | | CONFIGURATION ON STAND, THE MEAN ROOF HEIGHT OF THE | | | STAND AND COMPRESSORS, WEIGHT, CIRCLED THE DESIGN | | | PARAMETERS IN THE TABLES, ANCHORS AND UPLIFT VERSES | | | MOMENT. | | | | | | 9) IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 10) WHEN RESUBMITTING PLANS PLEASE INDICATE THE | | | REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES | | | AS NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-23 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-23 |
Time |
10:55 |
Sent To |
|
|
| Notes |
| 2017-05-23 14:43:35 | 2014 FBC- BUILDING PLAN REVIEW | | | W. P. B. PERMIT: 17041227 | | | ADD: 5015 GEORGIA AVE. | | | CONT: GRUBER HALL CORP. | | | TEL: 561-662-3377 | | | E-MAIL: [email protected] | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: TUES. MAY 23, 2017 | | | ACTION: DENIED | | | | | | 1) COVERSHEET C1 INDICATES THE 2014 FLORIDA BUILDING | | | CODE DESIGN DATA; | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR | | | BUILDINGS. | | | 107.3.5.1 COMMERCIAL BUILDINGS: | | | 107.3.5.1.1 BUILDING | | | 1A) MINIMUM TYPE OF CONSTRUCTION FBC-B TABLE 503. | | | | | | 1B) THE PLANS INDICATE AN R3 OCCUPANCY. PLEASE CORRECT. | | | PLEASE PROVIDE OCCUPANCY TYPES. THIS APPEARS TO BE A | | | MIXED USE OCCUPANCY BUSINESS AND STORAGE, PLEASE | | | INDICATE IF THE STORAGE IS S1 OR S2. 107.2.1.3 | | | ADDITIONAL INFORMATION REQUIRED. | | | | | | 1C) PLANS DO NOT INDICATE IF THE BUILDING IS FIRE | | | SPRINKLERED OR NOT? 107.3.5.1 COMMERCIAL BUILDINGS(5). | | | | | | 1D) PLANS ARE SILENT AS TO THE DESIGN, IF THE DIFFERENT | | | OCCUPANCIES ARE TO BE SEPARATED (FBC-B 508.2.4) OR | | | NON-SEPARATED (FBC-B 508.3) OCCUPANCIES? | | | | | | 1E) THE COVERSHEET INDICATES THE MEAN ROOF HEIGHT OF 15 | | | FEET WHEREAS SHEET S2.0 PROVIDES A MEAN ROOF HEIGHT OF | | | 22.5 FEET. PLEASE CORRECT THE DISCREPANCY IN PLANS. | | | 107.2.1.3 ADDITIONAL INFORMATION REQUIRED. | | | | | | 1F) SHEET SP1 INDICATES THE SIDE ROAD ADJACENT TO THIS | | | LOT IS EAGLES NEST RD. WHEREAS THE COUNTYWIDE GIS AND | | | P. B. C. PROPERTY APPRAISERS OFFICE BOTH SHOW THE SIDE | | | ROAD TO BE MCINTOSH ST. 107.2.1.3 ADDITIONAL | | | INFORMATION REQUIRED. | | | | | | 2) MISSING SOILS REPORTS? 2014 FBC-B 1803.5.2 | | | QUESTIONABLE SOIL. SUBMIT (2) SIGNED AND SEALED | | | ORIGINAL SOILS REPORTS. | | | | | | 3) SUBMIT ENERGY CALCULATIONS FOR THE ADDITION. SEE | | | 2014 FBC-ENERGY C101.4.3. | | | | | | 4) SHEET A1 INDICATES THE COMPONENTS AND CLADDING | | | PRESSURES, THE PRESSURES ARE LEFT BLANK. SHEET S2.0 | | | ALSO INDICATES THE WIND DESIGN PRESSURES. THE PRESSURES | | | ALSO INDICATE THIS IS A R3 OCCUPANCY. THE WIND DESIGN | | | INDICATES VULT AND VASD AS PART OF THE WIND DESIGN. THE | | | PLANS INDICATE THAT THE PRESSURES ARE MAXIMUM DOOR AND | | | WINDOW PRESSURES : | | | WINDOW +45.7 -61.6 | | | DOOR +44.5 -57.6 | | | | | | IF PRESSURES ARE VULT/ EXPOSURE C/ 10 SQ. FT. WALL ZONE | | | 5 / 22.5 MRH / +69.42/ -92.9 | | | IF PRESSURES ARE VASD/ EXPOSURE C/ 10 SQ. FT. WALL ZONE | | | 5/ 22.5 MRH / +41.64/ -55.71 | | | | | | 5) SHEET A3.0 INDICATES THE USE OF 2 X 12 ROOF FRAMING | | | MEMBERS. PLEASE IDENTIFY THE SPECIES OF WOOD AND GRADE | | | OF WOOD. PROVIDE THE LIVE LOADS CEILING ATTACHED AND | | | ALLOWABLE DEFLECTION. SEE FBC-B TABLE 2308.10.3 RAFTER | | | SPANS. | | | | | | 6) SHEET A3.0 ALSO INDICATES THE USE OF ICYNENE | | | INSULATION IN THE RAFTERS, PLEASE PROVIDE THE | | | MANUFACTURERS INSTALLATION REPORT, (ICC-ES REPORT). | | | | | | 7) SHEET A3.0 INDICATES THE USE OF CEILING JOIST FOR ? | | | OF THE CEILING FRAMING. THE PLANS DO NOT PROVIDE A | | | DETAIL OF HOW THE CEILING JOISTS ARE TO ATTACHED TO THE | | | CMU BLOCK WALL? NOR HOW THE CEILING JOIST IS TO BE | | | ANCHORED TO THE 2 X12 RAFTERS? 107.2.1.3 ADDITIONAL | | | INFORMATION. | | | | | | 8) IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | 9) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2017-12-13 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-12-13 |
Time |
11:18 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-12-13 |
Time |
11:18 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-09 |
Time |
14:43 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-09 |
Time |
14:43 |
Sent To |
|
|
| Notes |
| 2017-08-09 14:43:53 | NO CHANGES TO ELECTRICAL PLAN PREVIOUSLY APPROVED. | | | STAMPED PLANS. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
P |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-26 |
Time |
11:43 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-26 |
Time |
11:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
3 |
Status |
P |
Date |
2018-01-02 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-03 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
squinone |
Date |
2018-01-02 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
F |
Date |
2017-12-21 |
|
|
Cont ID |
|
| Sent By |
squinone |
Date |
2017-12-21 |
Time |
|
Rev Time |
0.00 |
| Received By |
squinone |
Date |
2017-12-21 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-12-21 15:10:48 | 1) NO CIVIL PLANS WERE SUBMITTED. | | | 2) SEC. 94-307. SURFACE WATER MANAGEMENT. ALL | | | DEVELOPMENT SHALL PROVIDE FOR ADEQUATE DRAINAGE AND | | | STORMWATER MANAGEMENT. PLEASE, SHOW HOW SITE WILL | | | HANDLE STORMWATER MANAGEMENT. | | | | | | SOFIA QUINONES-BENEJAM, EI | | | PROJECT ENGINEER | | | CITY OF WEST PALM BEACH | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33402 | | | (MAILING ADDRESS: PO BOX 3366) | | | P: 561.494.1108 | | | C: 561.459.6518 | | | F: 561.494.1116 | | | EMAIL: [email protected] |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
N |
Date |
2017-06-12 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2017-06-12 |
Time |
|
Rev Time |
|
| Received By |
mgonzale |
Date |
2017-06-12 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-06-12 10:42:50 | WILL TAKE A LOOK AT THE NEXT REVISION. |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2017-11-27 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-11-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-11-27 |
Time |
09:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-08-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-08-15 |
Time |
16:31 |
Sent To |
|
|
| Notes |
| 2017-08-15 17:13:07 | 2ND REVIEW | | | | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) COMPLIED | | | | | | | | | 2) SHEET 1.0 - THE EXISTING DOOR LEADING FROM THE | | | OFFICE AREA TO THE NEW WAREHOUSE IS NOT INDICATED WITH | | | A FIRE RATING. PER # 1 ABOVE FIRE SEPARATION RATING MAY | | | BE REQUIRED. | | | | | | PLEASE REVIEW, CORRECT OR CLARIFY. | | | | | | ADDITIONAL COMMENT | | | | | | THE PROPOSED DOES NOT MEET THE DEFINITION OF | | | ACCESSARY/INCIDENTAL USE. IN ADDITION, THE HAZARD OF | | | CONTENTS SHALL BE SEPARATED AT LEAST BY 1 HOUR. | | | | | | 6.1.14.1.3* WHERE INCIDENTAL TO ANOTHER OCCUPANCY, | | | AREAS USED AS FOLLOWS SHALL BE PERMITTED TO BE | | | CONSIDERED PART OF THE PREDOMINANT OCCUPANCY AND SHALL | | | BE SUBJECT TO THE PROVISIONS OF THE CODE THAT APPLY TO | | | THE PREDOMINANT OCCUPANCY: | | | (1) MERCANTILE, BUSINESS, INDUSTRIAL, OR STORAGE USE | | | (2)* NONRESIDENTIAL USE WITH AN OCCUPANT LOAD FEWER | | | THAN THAT ESTABLISHED BY SECTION 6.1 FOR THE OCCUPANCY | | | THRESHOLD | | | (3) PORTIONS OF BUILDINGS USED AS ACCESSORY OFFICES OR | | | FOR CUSTOMARY NON-HAZARDOUS USES NECESSARY FOR | | | TRANSACTING THE PRINCIPAL BUSINESS IN STORAGE AND | | | INDUSTRIAL OCCUPANCIES NEED NOT BE SEPARATED FROM THE | | | PRINCIPAL USE. | | | (4) INDUSTRIAL OCCUPANCIES PRODUCING, USING, OR STORING | | | LOW HAZARD PRODUCTS IN ACCORDANCE WITH SUBDIVISION | | | 6.2.2 NEED NOT BE SEPARATED BY FIRE-RESISTANT | | | CONSTRUCTION FROM THE OCCUPANCIES TO WHICH THEY ARE | | | ACCESSORY. | | | | | | 6.1.14.1.4 THE FOLLOWING ACCESSORY OCCUPANCIES SHALL | | | NOT BE REQUIRED TO BE SEPARATED FROM THE PRIMARY | | | OCCUPANCY AS REQUIRED IN 6.1.14.4: | | | (1) A KITCHEN IN AN ASSEMBLY OCCUPANCY DOES NOT | | | CONSTITUTE A MIXED OCCUPANCY. | | | (2) ACCESSORY USES IN INDUSTRIAL AND STORAGE | | | OCCUPANCIES AS OTHERWISE PROVIDED IN 6.1.14.1.3(1) | | | | | | (3) ROOMS OR SPACES USED FOR CUSTOMARY STORAGE OF | | | NONHAZARDOUS MATERIALS IN ASSEMBLY, BUSINESS, | | | EDUCATIONAL, INDUSTRIAL, MERCANTILE, HOTEL AND | | | DORMITORY, AND APARTMENT OCCUPANCIES WHICH IN AGGREGATE | | | DO NOT EXCEED 10% OF THE | | | MAJOR FLOOR AREA IN WHICH THEY ARE LOCATED. PROTECTION | | | FROM HAZARDS SHALL BE AS OTHERWISE PROVIDED IN THE | | | SPECIFIC OCCUPANCY CHAPTER. | | | | | | 6.2.1.3* FOR THE PURPOSE OF THIS CODE, WHERE DIFFERENT | | | DEGREES OF HAZARD OF CONTENTS EXIST IN DIFFERENT PARTS | | | OF A BUILDING OR STRUCTURE, THE MOST HAZARDOUS SHALL | | | GOVERN THE CLASSIFICATION, UNLESS HAZARDOUS AREAS ARE | | | SEPARATED OR PROTECTED AS SPECIFIED IN SECTION 8.7 AND | | | THE APPLICABLE SECTIONS OF CHAPTERS 11 THROUGH 43. | | | | | | 8.7 SPECIAL HAZARD PROTECTION. | | | 8.7.1 GENERAL. | | | 8.7.1.1* PROTECTION FROM ANY AREA HAVING A DEGREE OF | | | HAZARD GREATER THAN THAT NORMAL TO THE GENERAL | | | OCCUPANCY OF THE BUILDING OR STRUCTURE SHALL BE | | | PROVIDED BY ONE OF THE FOLLOWING MEANS: | | | (1) ENCLOSING THE AREA WITH A FIRE BARRIER WITHOUT | | | WINDOWS THAT HAS A 1-HOUR FIRE RESISTANCE RATING IN | | | ACCORDANCE WITH SECTION 8.3 | | | (2) PROTECTING THE AREA WITH AUTOMATIC EXTINGUISHING | | | SYSTEMS IN ACCORDANCE WITH SECTION 9.7 | | | (3) APPLYING BOTH 8.7.1.1(1) AND (2) WHERE THE HAZARD | | | IS SEVERE OR WHERE OTHERWISE SPECIFIED BY CHAPTERS 11 | | | THROUGH 43 | | | | | | THE SEPARATION IS REQUIRED TO BE 1 HOUR FIRE RATED | | | MINIMUM. | | | | | | PLEASE PROVIDE. | | | | | | 3) COMPLIED | | | | | | | | | 4) COMPLIED | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-03 |
Time |
16:21 |
Sent To |
|
|
| Notes |
| 2017-05-04 12:58:12 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | 1) SP 1 - A INDUSTRIAL ZONING IS INDICATED; HOWEVER, | | | THE OCCUPANCY CLASSIFICATION PER NFPA 101 IS NOT. | | | | | | 6.1 CLASSIFICATION OF OCCUPANCY. | | | 6.1.1 GENERAL. | | | 6.1.1.1 OCCUPANCY CLASSIFICATION. THE OCCUPANCY OF A | | | BUILDING OR STRUCTURE, OR PORTION OF A BUILDING OR | | | STRUCTURE, SHALL BE CLASSIFIED IN ACCORDANCE WITH 6.1.2 | | | THROUGH 6.1.13. OCCUPANCY CLASSIFICATION SHALL BE | | | SUBJECT TO THE RULING OF THE AUTHORITY HAVING | | | JURISDICTION WHERE THERE IS A QUESTION OF PROPER | | | CLASSIFICATION IN ANY INDIVIDUAL CASE. | | | | | | 6.1.14 MULTIPLE OCCUPANCIES. | | | 6.1.14.1 GENERAL. | | | 6.1.14.1.1 MULTIPLE OCCUPANCIES SHALL COMPLY WITH THE | | | REQUIREMENTS OF 6.1.14.1 AND ONE OF THE FOLLOWING: | | | (1) MIXED OCCUPANCIES ? 6.1.14.3 | | | (2) SEPARATED OCCUPANCIES ? 6.1.14.4 | | | | | | WHAT IS THE OCCUPANCY CLASSIFICATION AND IS IT MIXED OR | | | SEPARATED. | | | | | | | | | | | | 2) SHEET 1.0 - THE EXISTING DOOR LEADING FROM THE | | | OFFICE AREA TO THE NEW WAREHOUSE IS NOT INDICATED WITH | | | A FIRE RATING. PER # 1 ABOVE FIRE SEPARATION RATING MAY | | | BE REQUIRED. | | | | | | PLEASE REVIEW, CORRECT OR CLARIFY. | | | | | | | | | | | | 3) SHEET E 1.0 - THERE IS NOT EXIT SIGN AT THE NEW | | | WAREHOUSE MAN DOOR. AN EXIT IS REQUIRED FROM THIS NEW | | | SPACE AND IT IS REQUIRED TO BE ILLUMINATED. | | | | | | PLEASE REVIEW, CORRECT OR CLARITY. | | | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-05 |
Time |
12:34 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-03 |
Time |
16:09 |
Sent To |
|
|
| Notes |
| 2018-01-04 16:09:57 | RESUB ROUTED TO ACLANGE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-03 |
Time |
12:44 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-27 |
Time |
11:34 |
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-12-20 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-14 |
Time |
13:01 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-11-21 |
Time |
11:46 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-08-03 |
Time |
16:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-06-28 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-04-27 |
Time |
14:51 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
5 |
Status |
P |
Date |
2018-01-05 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-05 |
Time |
11:34 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-05 |
Time |
11:32 |
Sent To |
|
|
| Notes |
| 2018-01-05 11:34:46 | PALM BEACH COUNTY IMPACT FEES PAID | | | | | | RECEIPT #2018 0103 69 | | | | | | $1441.66 | | | | | | 1/2/2018 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
4 |
Status |
F |
Date |
2018-01-03 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2018-01-03 |
Time |
11:33 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2018-01-03 |
Time |
11:33 |
Sent To |
|
|
| Notes |
| 2018-01-03 11:33:41 | IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
3 |
Status |
F |
Date |
2017-12-20 |
|
|
Cont ID |
|
| Sent By |
aclange |
Date |
2017-12-20 |
Time |
08:02 |
Rev Time |
0.00 |
| Received By |
aclange |
Date |
2017-12-20 |
Time |
08:02 |
Sent To |
|
|
| Notes |
| 2017-12-20 08:02:27 | IMPACT FEES. BEFORE A PERMIT TO CONSTRUCT, MAY BE | | | ISSUED, IMPACT FEES MUST BE PAID TO PALM BEACH COUNTY. | | | THE ACTUAL PERMIT SET OF PLANS MUST BE STAMPED BY THAT | | | OFFICE, AND A COPY OF THE PAID RECEIPT ATTACHED TO THE | | | PERMIT APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
F |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-08-16 |
Time |
16:25 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-08-16 |
Time |
16:25 |
Sent To |
|
|
| Notes |
| 2017-08-16 16:25:38 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-23 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-23 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2017-05-23 14:42:17 | IMPACT FEES | | | BEFORE A PERMIT TO CONSTRUCT, MAY BE ISSUED, IMPACT | | | FEES MUST BE PAID TO PALM BEACH COUNTY. THE ACTUAL | | | PERMIT SET OF PLANS MUST BE STAMPED BY THAT OFFICE, AND | | | A COPY OF THE PAID RECEIPT ATTACHED TO THE PERMIT | | | APPLICATION. PLEASE CALL (561)233-5025 FOR MORE | | | INFORMATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-12-14 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-12-14 |
Time |
10:28 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-12-14 |
Time |
10:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-08-31 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-31 |
Time |
08:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-30 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2017-08-31 09:43:10 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17041227 | | | 8/31/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE AC CONTRACTOR KAREN OLIVER WHO PREPARED THE AC | | | DESIGN ON SHEET M.1 MUST SUBMIT A SUB-PERMIT AS THE | | | INSTALLING CONTRACTOR ON THE PROJECT- SECTION 105.3.1.2 | | | FBC-14 BUILDING. PLEASE NOTE THAT THE EXEMPTION LISTED | | | UNDER SECTION 105.3.1.2 SPECIFICALLY STATES THAT IN | | | LIEU OF A PLAN DRAWN BY AN ENGINEER, THE "INSTALLING" | | | CONTRACTOR MAY PREPARE THE DESIGN. | | | | | | 2) THE REQUESTED ARCHITECT'S SHOP DRAWING STAMP AND | | | SIGNATURE FOR THE AC PLAN WAS NOT PROVIDED. | | | | | | 3) THE ARCHITECT OR ENGINEER OF RECORD MUST PROVIDE | | | COMPLETE DETAILS AND DESIGN CALCULATIONS FOR | | | INSTALLATION OF THE ROOF STAND AND CONDENSER. THE | | | DETAILS ON M-1 ARE INCOMPLETE: A) PROVIDE DESIGN | | | PRESSURES. B) PROVIDE A SCHEDULE TO CORRELATE THE | | | CIRCLED NUMBERS 1-4. C) INDICATE THE STAND NOA NUMBER. | | | D) INDICATE THE SIZE OF THE STAND LEG ANCHORING LAG | | | BOLTS. | | | | | | 4) PROVIDE DUPLICATE COPIES ON THE AC AND ENERGY | | | CALCULATIONS. ONLY ONE SET WAS SUBMITTED- SECTION | | | 107.2.1 WPB AMENDMENTS TO THE FBC. PLEASE NOTE THAT THE | | | DESIGN PROFESSIONAL OF RECORD MUST PLACE SHOP DRAWING | | | STAMPS AND SIGNATURES ON THE CALCULATIONS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-03 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-03 |
Time |
10:15 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-03 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2017-05-03 10:45:51 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17041227 | | | 5/3/17 | | | | | | 1) SUBMIT ENERGY CALCULATIONS FOR THE ADDITION- SECTION | | | C101.4.3 FBC-14 ENERGY CONSERVATION. | | | | | | 2) SUBMIT AC COOLING AND HEATING CALCULATIONS FOR THE | | | NEW SYSTEM- SECTION C403.2.1. | | | | | | 3) PROVIDE WIND LOAD ENGINEERING FOR INSTALLATION OF | | | THE EXTERIOR CONDENSER- SECTION 301.15. | | | | | | 4) AUTOMATIC FUNCTIONING OF THE O/A DAMPER IS REQUIRED | | | PER SECTION C403.2.2 | | | | | | 5) PROVIDE A MECHANICAL SUB-PERMIT APPLICATION FROM | | | K.O. ENERGY DESIGN IF THEY ARE THE INSTALLING | | | CONTRACTOR. IF K.O. IS NOT THE INSTALLING CONTRACTOR | | | THEN THE PLANS MUST HAVE SHOP DRAWING APPROVAL BY THE | | | ARCHITECT OF RECORD. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
N |
Date |
2017-08-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-08-28 |
Time |
19:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-08-28 |
Time |
19:05 |
Sent To |
|
|
| Notes |
| 2017-08-28 19:05:33 | 2ND REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | NO PLUMBING INDICATED ON PLAN. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-23 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-23 |
Time |
16:41 |
Sent To |
|
|
| Notes |
| 2017-05-23 17:39:21 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: | | | | | | NO PLUMBING INDICATED ON PLAN. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-12-12 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2017-12-12 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-10-23 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-10-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
|
Date |
2017-10-23 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-08-15 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2017-08-15 |
Time |
13:59 |
Sent To |
|
|
| Notes |
| 2017-08-15 14:03:36 | *********************************ZONING REVIEW********* | | | ***************************************** | | | | | | THE ADDED SQUARE FOOTAGE WILL REQUIRE 1 ADDITIONAL | | | PARKING SPACE (1 SPACE PER 500 SQ/FT). PLEASE SHOW | | | PARKING (EXISTING AND NEW). PLEASE LET ME KNOW WHAT | | | QUESTIONS YOU MAY HAVE. | | | | | | THANKS, | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | 561-822-1449 | | | [email protected] |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-05-23 |
Time |
|
Rev Time |
0.00 |
| Received By |
awooten |
Date |
2017-05-17 |
Time |
16:12 |
Sent To |
B |
|
| Notes |
| 2017-05-25 15:09:39 | **********************************ZONING | | | REVIEW*********************************** | | | | | | DEVELOPMENT STANDARDS IN THE INDUSTRIAL (I) DISTRICT | | | SHALL BE AS FOLLOWS: | | | | | | (1) MINIMUM LOT DIMENSIONS: | | | A. LOT AREA: 5,000 SQUARE FEET. | | | B. LOT WIDTH: 50 FEET. | | | | | | (2) MINIMUM SETBACKS: | | | A. MINIMUM SETBACK FROM PROPERTY LINE ADJOINING PUBLIC | | | RIGHT-OF-WAY: ZERO FEET. | | | B. MINIMUM SETBACK FROM PROPERTY LINE NOT ADJOINING | | | PUBLIC RIGHT-OF-WAY: ZERO FEET; HOWEVER, A MINIMUM | | | SETBACK OF AT LEAST 15 FEET (BUFFER) WILL BE PROVIDED | | | WHEN ABUTTING RESIDENTIAL DISTRICTS. | | | | | | (3) MAXIMUM LOT COVERAGE BY BUILDING: 60 PERCENT. | | | | | | (4) MAXIMUM LOT COVERAGE BY IMPERVIOUS SURFACE: 85 | | | PERCENT. | | | | | | (5) MAXIMUM BUILDING HEIGHT: 50 FEET. | | | | | | (6) MINIMUM REQUIRED OPEN SPACE AND LANDSCAPE AREAS: | | | A. MINIMUM REQUIRED OPEN SPACE AREA: 40 PERCENT. | | | B. MINIMUM REQUIRED LANDSCAPE AREA: 15 PERCENT. | | | | | | (7) MAXIMUM FLOOR AREA RATIO: | | | A. 0.75 | | | B. PLANNED DEVELOPMENT: 0.75 | | | | | | PLEASE MAKE SURE THAT YOU INCLUDE ALL OF THE | | | DEVELOPMENT STANDARDS IN PROJECT DATA TABLE FOR THIS | | | LOT TO ENSURE THAT YOU ARE MEETING THE REQUIREMENTS | | | (OPEN SPACE AND LANDSCAPE AREA PERCENTAGES ARE | | | MISSING). PLEASE LET ME KNOW WHAT QUESTIONS YOU MAY | | | HAVE. | | | | | | ALANA WOOTEN | | | ASSOCIATE PLANNER | | | [email protected] | | | 561-822-1449 | | | |
|
|