| Plan Review Stops For Permit 17041218 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-08-04 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-04 |
Time |
13:22 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-04 |
Time |
09:45 |
Sent To |
Z |
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-07-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-17 |
Time |
12:47 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-17 |
Time |
12:47 |
Sent To |
|
|
| Notes |
| 2017-07-17 12:49:42 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLANS TO BE SIGNED AND SEALED BY DESIGN | | | PROFESSIONAL. | | | | | | FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF | | | CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL | | | INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL | | | BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT | | | APPLICATION. | | | THE CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A | | | REGISTERED DESIGN PROFESSIONAL WHERE REQUIRED BY | | | CHAPTER 471, FLORIDA STATUTES& 61G15 FLORIDA | | | ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA STATUTES& | | | 61G1 FLORIDA ADMINISTRATIVE CODE. | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-05-17 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-05-17 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2017-05-17 08:56:37 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | | | | 1. PALM BEACH COUNTY IMPACT FEES RERQUIRED. | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
4 |
Status |
P |
Date |
2017-08-16 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-16 |
Time |
08:07 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-16 |
Time |
08:07 |
Sent To |
M |
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
F |
Date |
2017-07-27 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-27 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-27 |
Time |
08:56 |
Sent To |
|
|
| Notes |
| 2017-07-27 09:36:54 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. RISER DIAGRAM PROVIDED SHOWS THREE 4/0 THHN IN 1 1/2 | | | CONDUIT. A 1 1/2 CONDUIT IS CAPABLE OF ONLY TWO OF THIS | | | SIZE WIRE PER THE ANNEX C TABLES. PROVIDE CORRECTION. | | | IDENTIFY IF THIS WIRE IS COPPER OR ALUMINUM. NEC ANNEX | | | C, FBC 107.2.1 | | | 2. RISER DIAGRAM ALSO SHOWS WHAT APPEARS TO BE 3 WIRES | | | FEEDING THE INTERIOR PANEL WITH A SEPARATE GROUND WIRE | | | GOING TO PANEL. THE EGC SHOULD BE IN THE SAME CONDUIT | | | AS THE POWER WIRES. PROVIDE CORRECTION. NEC 250.118, | | | 250.122; FBC RE3908.8 | | | 3. ELECTRICAL PLAN SHOWS DIFFERENT LOCATION OF AHU-1 | | | AND AHU-2 THAN THE MECHANICAL PLAN SHOWS. PROVIDE | | | CORRECTION WHERE NECESSARY. FBC 107.2.1 | | | 4. SPECS FOR TANKLESS WATER HEATER PROVIDED SHOW THAT | | | THE UNIT REQUIRES TWO 50 AMP CIRCUITS WITH #6 CU WIRE. | | | PANEL SCHEDULE SHOWS WHAT APPEARS TO BE ONE CIRCUIT | | | WITH #2 WIRE, THE BREAKER IS NOT IDENTIFIED. PROVIDE | | | CORRECTION FOR THIS CIRCUIT, ALSO SHOW BREAKER SIZES | | | FOR THE EVEN NUMBER CIRCUITS THAT ARE MISSING. NEC | | | 110.3, NEC 215.2, 215.5, 408.4; FBC RE3706.2 | | | 5. NEW SUBMISSION SHOWS PANEL B IN THE STORAGE AREA, | | | BUT NO DETAILS OF CIRCUITS OR PANEL SCHEDULE INCLUDED. | | | PROVIDE PANEL SCHEDULE, SHOW GFCI PROTECTION OF OUTLETS | | | FOR A STORAGE BUILDING. NEC 210.8(A)(2), 215.5, 408.4; | | | FBC RE3706.2, RE3902.2 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-07-10 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-07-10 |
Time |
11:06 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-07-10 |
Time |
11:06 |
Sent To |
|
|
| Notes |
| 2017-07-10 11:27:58 | CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | | | | ELECTRICAL REVIEW COMMENTS (2ND REVIEW): | | | | | | 1. PLANS NOT SEALED AS REQUIRED PER FLORIDA STATUTES. | | | FS471, FAC61G15-23. | | | 2. SHEET A1.0 SHOWS A NEW OVERHEAD SERVICE DROP FROM | | | FPL. PROVIDE CLEARANCE ABOVE ROOF PER CODE. NEC | | | 230.24(A); FBC RE3604.2.1 | | | 3. PANEL NOTE #1 REFERENCES THE PANEL SCHEDULE SHOWN, | | | HOWEVER, THERE IS NO PANEL SCHEDULE PROVIDED. PROVIDE | | | PANEL SCHEDULE, INDICATING WIRE AND BREAKER SIZE FOR | | | EACH CIRCUIT. NEC 215.5; FBC RE3706.2 | | | 4. PANEL NOTE #2 STATES THAT THERE WILL BE A 1/0 | | | ALUMINUM(AL) SERVICE CONDUCTOR. 1/0 AL IS NOT RATED FOR | | | THE SPECIFIED SERVICE CAPACITY. PROVIDE CORRECTION. NEC | | | 310.15; NEC 215.2; FBC RE3602.1 | | | 5. PROVIDE DETAIL OF CIRCUITS TO STORAGE BUILDING. PER | | | CODE: "A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY | | | A BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A | | | SERVICE DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY | | | ONE FEEDER OR BRANCH CIRCUIT". NEC 225.30; FBC 107.2.1 | | | 6. PROVIDE ACCURATE LOAD CALCULATION. THE LOAD | | | CALCULATION PROVIDED HAS ITEMS INCLUDED THAT SHOULD NOT | | | BE, SUCH AS LIGHTING AND FANS WHICH WOULD ALREADY BE | | | INCLUDED IN THE GENERAL LIGHTING LOAD BASED ON SQUARE | | | FOOTAGE. SOME ITEMS ARE MISSING, SUCH AS THE LAUNDRY | | | CIRCUIT AND THE DRYER LOAD. THE VOLTAGE USED FOR | | | CALCULATION SHOULD BE 240. MATH IS INCORRECT. NEC | | | 220.5; NEC 220; FBC RE3602.2 | | | 7. PROVIDE LIGHTING AND OUTLET FOR AHU2 IN ATTIC. FBC | | | RM1305.1.3.1 | | | 8. PLAN SHOWS A 200 AMP DISCONNECT FEEDING A 250 AMP | | | PANEL. PROVIDE CORRECTION, MATCHING DISCONNECT AND | | | PANEL TO REQUIRED LOAD CALCULATED. NEC 220; FBC | | | RE3602.3 | | | 9. PROVIDE SPEC SHEET FOR TANKLESS WATER HEATER. NEC | | | 110.3 | | | 10. SHOW ON PLAN ALL OUTLETS REQUIRED PER NEC 210.52 | | | FOR WALL SPACE. NEC 210.52; FBC RE3901.2.1 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-07-27 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-18 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-05-18 |
Time |
08:44 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-08-21 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-21 |
Time |
09:41 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-08-11 |
Time |
17:42 |
Sent To |
|
|
| Notes |
| 2017-08-14 17:42:25 | CTHROOP'S DESK |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-08-08 |
|
|
Cont ID |
|
| Sent By |
cpuell |
Date |
2017-08-08 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
cpuell |
Date |
2017-07-21 |
Time |
14:07 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-07-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-07-19 |
Time |
14:18 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-06-16 |
Time |
13:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-05-25 |
Time |
09:36 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-04-26 |
Time |
09:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
N |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-15 |
Time |
16:31 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-15 |
Time |
16:31 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-05-17 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-05-17 |
Time |
07:00 |
Sent To |
|
|
| Notes |
| 2017-05-17 08:54:49 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 1ST REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES | | | MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE | | | SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM | | | BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH | | | THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT | | | MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE | | | THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL | | | PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025. | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-08-21 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-08-21 |
Time |
09:37 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-08-18 |
Time |
15:00 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-07-19 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-07-19 |
Time |
14:16 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-07-19 |
Time |
14:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
P |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
hmoser |
Date |
2017-05-23 |
Time |
14:05 |
Rev Time |
0.00 |
| Received By |
hmoser |
Date |
2017-05-23 |
Time |
10:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
P |
Date |
2017-07-26 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-26 |
Time |
06:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-26 |
Time |
06:54 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-07-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-07-12 |
Time |
08:36 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-07-11 |
Time |
17:49 |
Sent To |
|
|
| Notes |
| 2017-07-12 08:37:58 | 2ND REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | HAS NOT COMPLIED 2ND REQUEST 1. THE SUB PERMIT | | | APPLICATION SHALL BE SIGNED BY THE QUALIFIER OF EACH | | | SUB CONTRACTOR. | | | | | | 2. PLANS NOT SEALED AS REQUIRED PER FLORIDA STATUTES. | | | FS471, FAC61G15-23. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-17 |
Time |
17:00 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-17 |
Time |
13:56 |
Sent To |
|
|
| Notes |
| 2017-05-17 17:18:33 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE SUB PERMIT APPLICATION SHALL BE SIGNED BY THE | | | QUALIFIER OF EACH SUB CONTRACTOR. | | | | | | 2. PLEASE PROVIDE EXISTING FLOOR PLAN SHEET D1.0 IS | | | MISSING FROM PLAN SET. PER WPB AMEND TO FBC 107.2.1 | | | | | | 3. IS ALL THE SANITARY BEING REPLACED IF NOT PLEASE | | | INDICATE ON THE RISER WHAT IS NEW AND WHAT IS EXISTING | | | TO REMAIN. PER WPB AMEND TO FBC 107.2.1 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
2 |
Status |
P |
Date |
2017-08-15 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-15 |
Time |
16:30 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-15 |
Time |
16:30 |
Sent To |
E |
|
| Notes |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
P |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-05-17 |
Time |
08:53 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-05-17 |
Time |
08:08 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
P |
Date |
2017-08-08 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-08-08 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-08-08 |
Time |
|
Sent To |
I |
|
| Notes |
| 2017-08-08 09:09:43 | ZONING PASSED WITH THE FOLLOWING PROVISIOS: | | | | | | 1.) SHRUBS REQUIRED AROUND NEW A/C UNITS FOR SCREENING. | | | | | | 2.) NEW CIRCULAR DRIVEWAY AND EXISTING DRIVEWAY | | | MODIFICATION NOT A PART OF THIS REVIEW. SEPARATE PERMIT | | | REQUIRED FOR THE DRIVEWAY. | | | | | | | | | | | | | | | | | 2017-08-04 16:43:59 | ROUTED TO LINDA LOUIE |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
F |
Date |
2017-06-28 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-06-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-06-28 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-06-28 16:01:53 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) NEED UPDATED SURVEY OF THE PROPERTY. [5/24/2017 | | | REPEAT COMMENT] | | | | | | 2.) SHOW SETBACK DISTANCE FROM THE NEW A/C UNITS TO THE | | | PROPERTY LINE(S). [5/24/2017 REPEAT COMMENT] | | | | | | 3.) WHAT IS THE SETBACK DISTANCE FROM THE PROPOSED | | | ADDITION TO THE EAST (REAR) PROPERTY LINE? PLEASE | | | PROVIDE DIMENSIONS IN THE PLANS. | | | | | | 4.) NORTH ELEVATION IS INCONSISTENT WITH THE FLOOR | | | PLAN. PLEASE ADDRESS FOR CONSISTENCY. | | | | | | | | | NOTES: | | | | | | * ZONE: SF7 | | | | | | * CORNER PROPERTY. PER ZLDR S.94-611, OLIVE ST. IS | | | DEFINED AS THE FRONT LOT LINE. | | | | | | * SCOPE OF WORK IS LESS THAN 50% OF THE VALUE OF THE | | | EXISTING BUILDING. | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-05-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-05-24 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-05-24 13:36:48 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) NEED UPDATED SURVEY OF THE PROPERTY. | | | | | | 2.) REAR BUILDING SETBACK DOES NOT MEET THE MINIMUM | | | REQUIREMENT OF THE ZONING CODE. THE MINIMUM REQUIRED | | | REAR SETBACK IS 12.5 FT. ONLY 5 FT. HAS BEEN PROVIDED | | | FOR THE REAR SETBACK. PLEASE ADDRESS. NOTE: THE | | | EXISTING CARPORT DOES NOT MEET CURRENT SETBACK | | | REQUIREMENT AND CANNOT BE ENCLOSED. [ZLDR | | | S.94-74(A)(2)] | | | | | | 3.) SHOW SETBACK DISTANCE FROM THE NEW A/C UNITS TO THE | | | PROPERTY LINE(S). | | | | | | 4.) WEST ELEVATION IS MISSING FOR THE EXITING STORAGE | | | BUILDING. PLEASE ADDRESS. | | | | | | | | | NOTES: | | | | | | * ZONE: SF7 | | | | | | * CORNER PROPERTY. PER ZLDR S.94-611, OLIVE ST. IS | | | DEFINED AS THE FRONT LOT LINE. | | | | | | * SCOPE OF WORK IS LESS THAN 50% OF THE VALUE OF | | | EXISTING BUILDING. | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. |
|
|