Plan Review Details - Permit 17041218
Plan Review Stops For Permit 17041218
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2017-08-04 Cont ID  
Sent By cthroop Date 2017-08-04 Time 13:22 Rev Time 0.00
Received By cthroop Date 2017-08-04 Time 09:45 Sent To Z
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-07-17 Cont ID  
Sent By cthroop Date 2017-07-17 Time 12:47 Rev Time 0.00
Received By cthroop Date 2017-07-17 Time 12:47 Sent To  
Notes
2017-07-17 12:49:42BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PLANS TO BE SIGNED AND SEALED BY DESIGN
 PROFESSIONAL.
  
 FBC107.1 GENERAL. SUBMITTAL DOCUMENTS CONSISTING OF
 CONSTRUCTION DOCUMENTS, STATEMENT OF SPECIAL
 INSPECTIONS, GEOTECHNICAL REPORT AND OTHER DATA SHALL
 BE SUBMITTED IN TWO OR MORE SETS WITH EACH PERMIT
 APPLICATION.
 THE CONSTRUCTION DOCUMENTS SHALL BE PREPARED BY A
 REGISTERED DESIGN PROFESSIONAL WHERE REQUIRED BY
 CHAPTER 471, FLORIDA STATUTES& 61G15 FLORIDA
 ADMINISTRATIVE CODE OR CHAPTER 481, FLORIDA STATUTES&
 61G1 FLORIDA ADMINISTRATIVE CODE.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-17 Cont ID  
Sent By cthroop Date 2017-05-17 Time 08:54 Rev Time 0.00
Received By cthroop Date 2017-05-17 Time 07:00 Sent To  
Notes
2017-05-17 08:56:37BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
  
 1. PALM BEACH COUNTY IMPACT FEES RERQUIRED.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2017-08-16 Cont ID  
Sent By jpearson Date 2017-08-16 Time 08:07 Rev Time 0.00
Received By jpearson Date 2017-08-16 Time 08:07 Sent To M
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2017-07-27 Cont ID  
Sent By jpearson Date 2017-07-27 Time 08:56 Rev Time 0.00
Received By jpearson Date 2017-07-27 Time 08:56 Sent To  
Notes
2017-07-27 09:36:54CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW.
  
 1. RISER DIAGRAM PROVIDED SHOWS THREE 4/0 THHN IN 1 1/2
 CONDUIT. A 1 1/2 CONDUIT IS CAPABLE OF ONLY TWO OF THIS
 SIZE WIRE PER THE ANNEX C TABLES. PROVIDE CORRECTION.
 IDENTIFY IF THIS WIRE IS COPPER OR ALUMINUM. NEC ANNEX
 C, FBC 107.2.1
 2. RISER DIAGRAM ALSO SHOWS WHAT APPEARS TO BE 3 WIRES
 FEEDING THE INTERIOR PANEL WITH A SEPARATE GROUND WIRE
 GOING TO PANEL. THE EGC SHOULD BE IN THE SAME CONDUIT
 AS THE POWER WIRES. PROVIDE CORRECTION. NEC 250.118,
 250.122; FBC RE3908.8
 3. ELECTRICAL PLAN SHOWS DIFFERENT LOCATION OF AHU-1
 AND AHU-2 THAN THE MECHANICAL PLAN SHOWS. PROVIDE
 CORRECTION WHERE NECESSARY. FBC 107.2.1
 4. SPECS FOR TANKLESS WATER HEATER PROVIDED SHOW THAT
 THE UNIT REQUIRES TWO 50 AMP CIRCUITS WITH #6 CU WIRE.
 PANEL SCHEDULE SHOWS WHAT APPEARS TO BE ONE CIRCUIT
 WITH #2 WIRE, THE BREAKER IS NOT IDENTIFIED. PROVIDE
 CORRECTION FOR THIS CIRCUIT, ALSO SHOW BREAKER SIZES
 FOR THE EVEN NUMBER CIRCUITS THAT ARE MISSING. NEC
 110.3, NEC 215.2, 215.5, 408.4; FBC RE3706.2
 5. NEW SUBMISSION SHOWS PANEL B IN THE STORAGE AREA,
 BUT NO DETAILS OF CIRCUITS OR PANEL SCHEDULE INCLUDED.
 PROVIDE PANEL SCHEDULE, SHOW GFCI PROTECTION OF OUTLETS
 FOR A STORAGE BUILDING. NEC 210.8(A)(2), 215.5, 408.4;
 FBC RE3706.2, RE3902.2
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2017-07-10 Cont ID  
Sent By jpearson Date 2017-07-10 Time 11:06 Rev Time 0.00
Received By jpearson Date 2017-07-10 Time 11:06 Sent To  
Notes
2017-07-10 11:27:58CODES IN EFFECT:
 FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE
  
 ELECTRICAL REVIEW COMMENTS (2ND REVIEW):
  
 1. PLANS NOT SEALED AS REQUIRED PER FLORIDA STATUTES.
 FS471, FAC61G15-23.
 2. SHEET A1.0 SHOWS A NEW OVERHEAD SERVICE DROP FROM
 FPL. PROVIDE CLEARANCE ABOVE ROOF PER CODE. NEC
 230.24(A); FBC RE3604.2.1
 3. PANEL NOTE #1 REFERENCES THE PANEL SCHEDULE SHOWN,
 HOWEVER, THERE IS NO PANEL SCHEDULE PROVIDED. PROVIDE
 PANEL SCHEDULE, INDICATING WIRE AND BREAKER SIZE FOR
 EACH CIRCUIT. NEC 215.5; FBC RE3706.2
 4. PANEL NOTE #2 STATES THAT THERE WILL BE A 1/0
 ALUMINUM(AL) SERVICE CONDUCTOR. 1/0 AL IS NOT RATED FOR
 THE SPECIFIED SERVICE CAPACITY. PROVIDE CORRECTION. NEC
 310.15; NEC 215.2; FBC RE3602.1
 5. PROVIDE DETAIL OF CIRCUITS TO STORAGE BUILDING. PER
 CODE: "A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY
 A BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A
 SERVICE DISCONNECTING MEANS SHALL BE SUPPLIED BY ONLY
 ONE FEEDER OR BRANCH CIRCUIT". NEC 225.30; FBC 107.2.1
 6. PROVIDE ACCURATE LOAD CALCULATION. THE LOAD
 CALCULATION PROVIDED HAS ITEMS INCLUDED THAT SHOULD NOT
 BE, SUCH AS LIGHTING AND FANS WHICH WOULD ALREADY BE
 INCLUDED IN THE GENERAL LIGHTING LOAD BASED ON SQUARE
 FOOTAGE. SOME ITEMS ARE MISSING, SUCH AS THE LAUNDRY
 CIRCUIT AND THE DRYER LOAD. THE VOLTAGE USED FOR
 CALCULATION SHOULD BE 240. MATH IS INCORRECT. NEC
 220.5; NEC 220; FBC RE3602.2
 7. PROVIDE LIGHTING AND OUTLET FOR AHU2 IN ATTIC. FBC
 RM1305.1.3.1
 8. PLAN SHOWS A 200 AMP DISCONNECT FEEDING A 250 AMP
 PANEL. PROVIDE CORRECTION, MATCHING DISCONNECT AND
 PANEL TO REQUIRED LOAD CALCULATED. NEC 220; FBC
 RE3602.3
 9. PROVIDE SPEC SHEET FOR TANKLESS WATER HEATER. NEC
 110.3
 10. SHOW ON PLAN ALL OUTLETS REQUIRED PER NEC 210.52
 FOR WALL SPACE. NEC 210.52; FBC RE3901.2.1
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN
 RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES
 INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE
 PREVIOUSLY REVIEWED SHEETS.
  
 SINCERELY,
  
 JOHN PEARSON
 ELECTRICAL PLANS EXAMINER
 561-805-6746
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-07-27 Cont ID  
Sent By jleahy Date 2017-05-18 Time 08:54 Rev Time 0.00
Received By jpearson Date 2017-05-18 Time 08:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-08-21 Cont ID  
Sent By cthroop Date 2017-08-21 Time 09:41 Rev Time 0.00
Received By hmoser Date 2017-08-11 Time 17:42 Sent To  
Notes
2017-08-14 17:42:25CTHROOP'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-08-08 Cont ID  
Sent By cpuell Date 2017-08-08 Time 10:48 Rev Time 0.00
Received By cpuell Date 2017-07-21 Time 14:07 Sent To  
Notes
2017-07-24 14:08:08R19

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-19 Cont ID  
Sent By hmoser Date 2017-07-19 Time 14:18 Rev Time 0.00
Received By hmoser Date 2017-06-16 Time 13:26 Sent To  
Notes
2017-06-19 13:26:51R35

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-25 Cont ID  
Sent By lmarchan Date 2017-05-25 Time 09:36 Rev Time 0.00
Received By lmarchan Date 2017-04-26 Time 09:54 Sent To  
Notes
2017-04-28 09:54:25R10

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status N Date 2017-08-15 Cont ID  
Sent By cthroop Date 2017-08-15 Time 16:31 Rev Time 0.00
Received By cthroop Date 2017-08-15 Time 16:31 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-05-17 Cont ID  
Sent By cthroop Date 2017-05-17 Time 08:53 Rev Time 0.00
Received By cthroop Date 2017-05-17 Time 07:00 Sent To  
Notes
2017-05-17 08:54:49BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-08-21 Cont ID  
Sent By hmoser Date 2017-08-21 Time 09:37 Rev Time 0.00
Received By hmoser Date 2017-08-18 Time 15:00 Sent To  
Notes
2017-08-21 09:40:46 
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-07-19 Cont ID  
Sent By hmoser Date 2017-07-19 Time 14:16 Rev Time 0.00
Received By hmoser Date 2017-07-19 Time 14:16 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2017-05-23 Cont ID  
Sent By hmoser Date 2017-05-23 Time 14:05 Rev Time 0.00
Received By hmoser Date 2017-05-23 Time 10:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-07-26 Cont ID  
Sent By gjohnson Date 2017-07-26 Time 06:54 Rev Time 0.00
Received By gjohnson Date 2017-07-26 Time 06:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-07-12 Cont ID  
Sent By gjohnson Date 2017-07-12 Time 08:36 Rev Time 0.00
Received By gjohnson Date 2017-07-11 Time 17:49 Sent To  
Notes
2017-07-12 08:37:582ND REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 HAS NOT COMPLIED 2ND REQUEST 1. THE SUB PERMIT
 APPLICATION SHALL BE SIGNED BY THE QUALIFIER OF EACH
 SUB CONTRACTOR.
  
 2. PLANS NOT SEALED AS REQUIRED PER FLORIDA STATUTES.
 FS471, FAC61G15-23.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-05-17 Cont ID  
Sent By gjohnson Date 2017-05-17 Time 17:00 Rev Time 0.00
Received By gjohnson Date 2017-05-17 Time 13:56 Sent To  
Notes
2017-05-17 17:18:331ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. THE SUB PERMIT APPLICATION SHALL BE SIGNED BY THE
 QUALIFIER OF EACH SUB CONTRACTOR.
  
 2. PLEASE PROVIDE EXISTING FLOOR PLAN SHEET D1.0 IS
 MISSING FROM PLAN SET. PER WPB AMEND TO FBC 107.2.1
  
 3. IS ALL THE SANITARY BEING REPLACED IF NOT PLEASE
 INDICATE ON THE RISER WHAT IS NEW AND WHAT IS EXISTING
 TO REMAIN. PER WPB AMEND TO FBC 107.2.1
  
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2017-08-15 Cont ID  
Sent By cthroop Date 2017-08-15 Time 16:30 Rev Time 0.00
Received By cthroop Date 2017-08-15 Time 16:30 Sent To E
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-05-17 Cont ID  
Sent By cthroop Date 2017-05-17 Time 08:53 Rev Time 0.00
Received By cthroop Date 2017-05-17 Time 08:08 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2017-08-08 Cont ID  
Sent By llouie Date 2017-08-08 Time   Rev Time 0.00
Received By llouie Date 2017-08-08 Time   Sent To I
Notes
2017-08-08 09:09:43ZONING PASSED WITH THE FOLLOWING PROVISIOS:
  
 1.) SHRUBS REQUIRED AROUND NEW A/C UNITS FOR SCREENING.
  
 2.) NEW CIRCULAR DRIVEWAY AND EXISTING DRIVEWAY
 MODIFICATION NOT A PART OF THIS REVIEW. SEPARATE PERMIT
 REQUIRED FOR THE DRIVEWAY.
  
  
  
  
  
2017-08-04 16:43:59ROUTED TO LINDA LOUIE

Review Stop Z ZONING
Rev No 2 Status F Date 2017-06-28 Cont ID  
Sent By llouie Date 2017-06-28 Time   Rev Time 0.00
Received By llouie Date 2017-06-28 Time   Sent To  
Notes
2017-06-28 16:01:53** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) NEED UPDATED SURVEY OF THE PROPERTY. [5/24/2017
 REPEAT COMMENT]
  
 2.) SHOW SETBACK DISTANCE FROM THE NEW A/C UNITS TO THE
 PROPERTY LINE(S). [5/24/2017 REPEAT COMMENT]
  
 3.) WHAT IS THE SETBACK DISTANCE FROM THE PROPOSED
 ADDITION TO THE EAST (REAR) PROPERTY LINE? PLEASE
 PROVIDE DIMENSIONS IN THE PLANS.
  
 4.) NORTH ELEVATION IS INCONSISTENT WITH THE FLOOR
 PLAN. PLEASE ADDRESS FOR CONSISTENCY.
  
  
 NOTES:
  
 * ZONE: SF7
  
 * CORNER PROPERTY. PER ZLDR S.94-611, OLIVE ST. IS
 DEFINED AS THE FRONT LOT LINE.
  
 * SCOPE OF WORK IS LESS THAN 50% OF THE VALUE OF THE
 EXISTING BUILDING.
  
 * REVISION MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2017-05-24 Cont ID  
Sent By llouie Date 2017-05-24 Time   Rev Time 0.00
Received By llouie Date 2017-05-24 Time   Sent To  
Notes
2017-05-24 13:36:48** FAILED **
  
 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE
 COMMENTS IN WRITING AND/OR ON THE PLANS WHERE
 APPLICABLE:
  
 1.) NEED UPDATED SURVEY OF THE PROPERTY.
  
 2.) REAR BUILDING SETBACK DOES NOT MEET THE MINIMUM
 REQUIREMENT OF THE ZONING CODE. THE MINIMUM REQUIRED
 REAR SETBACK IS 12.5 FT. ONLY 5 FT. HAS BEEN PROVIDED
 FOR THE REAR SETBACK. PLEASE ADDRESS. NOTE: THE
 EXISTING CARPORT DOES NOT MEET CURRENT SETBACK
 REQUIREMENT AND CANNOT BE ENCLOSED. [ZLDR
 S.94-74(A)(2)]
  
 3.) SHOW SETBACK DISTANCE FROM THE NEW A/C UNITS TO THE
 PROPERTY LINE(S).
  
 4.) WEST ELEVATION IS MISSING FOR THE EXITING STORAGE
 BUILDING. PLEASE ADDRESS.
  
  
 NOTES:
  
 * ZONE: SF7
  
 * CORNER PROPERTY. PER ZLDR S.94-611, OLIVE ST. IS
 DEFINED AS THE FRONT LOT LINE.
  
 * SCOPE OF WORK IS LESS THAN 50% OF THE VALUE OF
 EXISTING BUILDING.
  
 * REVISION MAY RESULT IN ADDITIONAL COMMENTS.
  
 * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE
 QUESTIONS.