| Plan Review Stops For Permit 17041175 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-25 |
Time |
09:34 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-25 |
Time |
09:34 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-03 |
|
|
Cont ID |
|
| Sent By |
jwitmer |
Date |
2017-05-03 |
Time |
17:29 |
Rev Time |
0.00 |
| Received By |
jwitmer |
Date |
2017-05-03 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2017-05-03 17:24:54 | BUILDING PLAN REVIEW | | | W. P. B. REVISION: 17041175 | | | W. P. B. PERMIT: 16060610 | | | ADD: 1045 CHARLOTTE AVE. | | | CONT: REPUBLIC CONSTRUCTION CORP. | | | TEL: 561-801-0697 | | | E-MAIL: ?????????????? | | | | | | 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | | ADMINISTRATION | | | | | | 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE. | | | ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | | FLORIDA BUILDING CODE, BUILDING. | | | | | | 1ST REVIEW | | | DATE: WED. MAY 03/2017 | | | ACTION: DENIED | | | | | | 1) SHEET A-02 THE MENS SHOWERS ARE SHOWN TO BE 2 FOOT | | | 10 INCHES DEEP. THE ACCESSIBLE TRANSFER TYPE SHOWER THE | | | COMPARTMENT SHALL BE 36 INCHES BY 36 INCHES. SEE | | | 608.2.1. | | | | | | 2) SHEET A-02 WITH THE NEW LAYOUT IN THE MENS LOCKER | | | ROOM THERE ARE 2 BENCHES SHOWN. PLEASE PROVIDE | | | COMPLIANCE WITH AT LEAST ONE BENCH FOR 2014 ACCESS. | | | CODE 903.3 SIZE, 903.4, BACK SUPPORT, 903.6 HEIGHT, | | | 903.6 STRUCTURAL STRENGTH & 903.7 WET LOCATIONS. | | | | | | 3) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION | | | & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS | | | NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A | | | TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT | | | NUMBER, WITH A DESCRIPTION OF THE REVISION MADE, | | | IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE | | | CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT. | | | THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | | | JAMES A. WITMER BN, PX, CBO | | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | | DEPARTMENT | | | 401 CLEMATIS ST. | | | WEST PALM BEACH. FL 33402 | | | TEL: 561-805-6715 | | | FAX: 561-805-6676 | | | E-MAIL: [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-24 |
Time |
17:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
|
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-05-04 |
Time |
11:25 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-05-04 |
Time |
11:25 |
Sent To |
|
|
| Notes |
| 2017-05-04 11:25:52 | PLEASE ADDRESS MECHANICAL COMMENTS FOR AN ELECTRICAL | | | APPROVAL. FBC 107.3.5 | | | | | | V. PEREZ | | | *6717 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-24 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-24 |
Time |
12:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-05-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-04 |
Time |
13:31 |
Sent To |
|
|
| Notes |
| 2017-05-04 14:31:50 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) SHEET E 1 - THERE DOES NOT APPEARS TO BE A EXIT SIGN | | | IN THE WOMENS RESTROOM. | | | | | | PLEASE REVIEW AND/OR CORRECT. |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-05-19 |
Time |
13:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-05 |
Time |
08:03 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-26 |
Time |
16:47 |
Sent To |
|
|
| Notes |
| 2017-05-11 08:03:26 | CLOSED STOP (CUSTOMER IS AWARE AS THEY CHECKED OUT ONE | | | SET OF PLANS ON 5/5) | | 2017-04-27 14:59:23 | B20 |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-25 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-25 |
Time |
09:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-25 |
Time |
09:01 |
Sent To |
|
|
| Notes |
| 2017-05-25 09:56:05 | MECHANICAL PROVISOS: | | | 5/25/17 | | | | | | 1) ENGINEER'S LETTERS FROM BACH DESIGN ENGINEERS AND | | | TRANE REQUIRED FOR INSTALLATION OF OAU-1 ON THE INSIDE | | | OF THE BUILDING. | | | 2) SUBMIT FLORIDA PRODUCT APPROVALS AND/OR MIAMI-DADE | | | NOAS FOR THE ROOFTOP FANS AND SIDEWALL LOUVERS WITH | | | SHOP DRAWING APPROVAL SIGNATURES BY THE EOR. | | | | | | CCOLE | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-02 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-02 |
Time |
08:54 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-02 |
Time |
07:48 |
Sent To |
|
|
| Notes |
| 2017-05-02 08:57:43 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17041175 | | | 5/2/17 | | | | | | 1) THE EXHAUST SYSTEM REQUIRES INSTALLATION OF AN | | | ENERGY RECOVERY VENTILATOR- SEE SECTION & TABLE | | | C403.2.6 FBC-14 ENERGY CONSERVATION. PLEASE REVISE THE | | | PLAN ACCORDINGLY. | | | | | | 2) PLEASE PROVIDE EXHAUST VENTILATION CALULATIONS FOR | | | THE BAQTHROOMS AND LOCKER ROOMS- TABLE 403.3 FBC-14 | | | MECHANICAL. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-05-24 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-24 |
Time |
16:41 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-24 |
Time |
16:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-02 |
Time |
15:15 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-02 |
Time |
11:42 |
Sent To |
|
|
| Notes |
| 2017-05-02 15:28:10 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHT A-02 SHOWS DEPTH OF ACCESSIBLE SHOWER AT 2'10" | | | IT SHALL BE 3'. PER FBC ACC 608.2.1 | | | | | | 2. SHT A-04 SHOWER CONTROLS SHALL COMPLY WITH FBC ACC | | | 608.5.1 TRANSFER TYPE SHOWER COMPARTMENTS. | | | IN TRANSFER TYPE SHOWER COMPARTMENTS, THE CONTROLS, | | | FAUCETS, AND SHOWER SPRAY UNIT SHALL BE INSTALLED ON | | | THE SIDE WALL OPPOSITE THE SEAT 38 INCHES (965 MM) | | | MINIMUM AND 48 INCHES (1220 MM) MAXIMUM ABOVE THE | | | SHOWER FLOOR AND SHALL BE LOCATED ON THE CONTROL WALL | | | 15 INCHES (380 MM) MAXIMUM FROM THE CENTERLINE OF THE | | | SEAT TOWARD THE SHOWER OPENING. PLEASE REMOVE DETAIL | | | SHOWING 27" MAX FROM CENTER OF CONTROLS TO FRONT OF | | | SHOWER. IT SHALL BE 15" | | | | | | 3. SHT. P-2 THE SANITARY RISER THE BRANCH DRAIN FOR THE | | | LAVATORY SHALL CONNECT BETWEEN THE LAST TO WATER | | | CLOSETS NOT THE END OF THE BRANCH. PER FBC PL 914.2 | | | VENT CONNECTION. | | | THE CIRCUIT VENT CONNECTION SHALL BE LOCATED BETWEEN | | | THE TWO MOST UPSTREAM FIXTURE DRAINS. THE VENT SHALL | | | CONNECT TO THE HORIZONTAL BRANCH AND SHALL BE INSTALLED | | | IN ACCORDANCE WITH SECTION 905. THE CIRCUIT VENT PIPE | | | SHALL NOT RECEIVE THE DISCHARGE OF ANY SOIL OR WASTE. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|