Plan Review Details - Permit 17041092
Plan Review Stops For Permit 17041092
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-07-31 Cont ID  
Sent By jwitmer Date 2017-07-31 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2017-07-31 Time 06:15 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-06 Cont ID  
Sent By jwitmer Date 2017-05-06 Time 07:59 Rev Time 0.00
Received By jwitmer Date 2017-05-06 Time 07:27 Sent To  
Notes
2017-05-06 07:50:592014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17041092
 ADD: 525 S. FLAGLER DR. SUITE # 18A
 CONT: GULFSTREAM WOODWORK
 TEL: 561-231-1810
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. MAY 06/2017
 ACTION: DENIED
  
 1) SHEET A-1 INDICATES IN THE INTERIOR-DEMO PLAN OF THE
 BATHROOM NOTE # 5 INDICATES THE REMOVAL OF THE BATHROOM
 FLOOR AND REINSTALLATION OF FLOOR WITH UNDERLAYMENT.
 BLDG TYPE: TYPE I/ TYPE II FLOOR INSULATION (FBC-B
 2014)
 FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO
 HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES
 TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS
 LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 1A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 1B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 1C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 2) WHEN RESUBMITTING PLANS PLEASE INDICATE THE REVISION
 & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES AS
 NECESSARY, COLLATE AND STAPLE INTO SETS OF PLANS. A
 TRANSMITTAL LETTER LISTING THE ORIGINAL REVIEW COMMENT
 NUMBER, WITH A DESCRIPTION OF THE REVISION MADE,
 IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE THE
 CHANGES CAN BE FOUND WILL HELP TO EXPEDITE YOUR PERMIT.
 THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 JAMES A. WITMER BN, PX, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST.
 WEST PALM BEACH. FL 33402
 TEL: 561-805-6715
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-07-28 Cont ID  
Sent By jpearson Date 2017-07-28 Time 11:31 Rev Time 0.00
Received By jpearson Date 2017-07-28 Time 11:31 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-05-11 Cont ID  
Sent By jleahy Date 2017-05-11 Time 15:07 Rev Time 0.00
Received By jleahy Date 2017-05-11 Time 15:07 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-07-27 Cont ID  
Sent By scaldero Date 2017-07-27 Time 12:27 Rev Time 0.00
Received By scaldero Date 2017-07-27 Time 12:27 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-04-27 Cont ID  
Sent By scaldero Date 2017-04-27 Time 11:06 Rev Time 0.00
Received By scaldero Date 2017-04-27 Time 11:06 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-31 Cont ID  
Sent By jwitmer Date 2017-07-31 Time 06:45 Rev Time 0.00
Received By jwitmer Date 2017-07-20 Time 11:26 Sent To  
Notes
2017-07-21 11:26:22B15

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-11 Cont ID  
Sent By jleahy Date 2017-05-11 Time 15:07 Rev Time 0.00
Received By jleahy Date 2017-04-25 Time 14:13 Sent To  
Notes
2017-04-26 14:13:31B02

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2017-05-06 Time   Rev Time 0.00
Received By jwitmer Date 2017-05-06 Time 07:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-07-27 Cont ID  
Sent By gjohnson Date 2017-07-27 Time 09:13 Rev Time 0.00
Received By gjohnson Date 2017-07-26 Time 17:21 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-05-08 Cont ID  
Sent By gjohnson Date 2017-05-08 Time 12:00 Rev Time 0.00
Received By gjohnson Date 2017-05-08 Time 10:01 Sent To  
Notes
***NONE***