Plan Review Details - Permit 17040981
Plan Review Stops For Permit 17040981
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-06-01 Cont ID  
Sent By jwitmer Date 2017-06-01 Time 11:06 Rev Time 0.00
Received By jwitmer Date 2017-06-01 Time 10:13 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-09 Cont ID  
Sent By jwitmer Date 2017-05-09 Time 11:46 Rev Time 0.00
Received By jwitmer Date 2017-05-05 Time 17:02 Sent To  
Notes
2017-05-09 11:46:502014 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 17040981
 ADD: 901 S. FLAGLER DR. DORMS: 307, 310, 311, 312, 407,
 410, 411, 412, 507, & 508
 CONT: BMS CATS INC.
 TEL: 954-319-3524
 E-MAIL: [email protected]
  
 2014 FLORIDA BUILDING CODE W 2014 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2014 EXISTING BUILDING CODE LEVEL II 701.3 COMPLIANCE.
 ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND
 SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: SAT. MAY 06/2017
 ACTION: DENIED
  
 1A) ALL OF THE 10 DORM UNITS SHOW EITHER A NOTE # 2 OR
 5 FOR A NEW EXTERIOR DOOR AND SIDE LIGHT (NOTE # 2) OR
 A NEW EXTERIOR DOOR W/ TRANSOM (NOTE # 5). PRODUCT
 APPROVAL: FL -14676.1. PLEASE SUBMIT THE PRODUCT
 APPROVAL IN COMPLIANCE WITH;
 2014 FBC-B 1609.1.2 PROTECTION OF OPENINGS,
 1609.6.4.4.1 COMPONENTS & CLADDING. FLORIDA DEPARTMENT
 OF COMMUNITY AFFAIRS, ADMINISTRATIVE CODE 61G20-3.005,
 RULE 9N-3 NOV. 01/ 2010 (31) SUB-CATEGORY OF PRODUCTS
 OR CONSTRUCTION SYSTEMS THAT WILL REQUIRE PRODUCT
 APPROVALS:
 (31)(A) EXTERIOR DOORS, SIDELIGHTS & TRANSOMS
  
 1B) THE EXTERIOR DOOR NOTES 2 & 5 BOTH HAVE THE WORDING
 DAYBAR PRODUCT APPROVAL FL-14676.1 OR EQUAL.
 THE PLANS CANNOT SAY EQUAL. INFORMATIONAL/ EQUIVALENCY
 2014 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1.3: W.P.B.
 ADMINISTRATIVE CODE/2014 DRAWINGS & SPECIFICATIONS
 SHALL CONTAIN INFORMATION, IN THE FORM OF NOTES OR
 OTHERWISE, AS TO THE QUALITY OF MATERIALS, WHERE
 QUALITY IS ESSENTIAL TO CONFORMITY WITH THE TECHNICAL
 CODES. SUCH INFORMATION SHALL BE SPECIFIC TO THE
 TECHNICAL CODES "SHALL NOT BE CITED AS A WHOLE OR IN
 PART, NOR THE TERM "LEGAL" OR ITS EQUIVALENT BE USED AS
 A SUBSTITUTE FOR SPECIFIC INFORMATION".
  
 1C) IDENTIFY GLAZING. FOR ALL PRODUCTS WITH GLAZING,
 PLEASE IDENTIFY THE OPENING WIDTH & HEIGHT, TYPE OF
 GLAZING, MULLION INFORMATION IF REQUIRED, ATTACHMENTS
 AND ASSOCIATE PRESSURES FOR EACH OPENING SIZE. 2014
 FBC-B 1405.13.1 INSTALLATION. WINDOWS AND DOORS SHALL
 BE INSTALLED IN ACCORDANCE WITH APPROVED MANUFACTURER?S
 INSTRUCTIONS. FASTENER SIZE AND SPACING SHALL BE
 PROVIDED IN SUCH INSTRUCTIONS AND SHALL BE CALCULATED
 BASED ON MAXIMUM LOADS AND SPACING USED IN THE TESTS.
  
 2) THERE ARE UNITS WHERE THE BATHROOM FLOORING TILE IS
 BEING REMOVED, 9 OF THE 10 DORMS, 310, 311, 312, 407,
 410, 411, 412, 507 & 508. PLEASE SHOW COMPLIANCE WITH:
 FOR TILE, STONE, MARBLE AND WOOD FLOORING ALL NEED TO
 HAVE HAD THE SOUND UNDERLAYMENT TESTED FLOOR ASSEMBLIES
 TO THE FOLLOWING STANDARDS AND MEET THE QUALIFICATIONS
 LISTED UNDER EACH OF THE STANDARDS FOR A 6 INCH
 CONCRETE FLOOR ASSEMBLY/ NO DROPPED CEILING:
 PLEASE PROVIDE TEST REPORTS SHOWING COMPLIANCE WITH:
 2A) FBC-B 2014 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E 492.
  
 2B) FBC-B 2014 1207.2 AIR-BORNE SOUND.
 WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES
 SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM
 PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION
 CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED)
 FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM
 E 90.
  
 2C) FLAME SPREAD- FBC-B 2014 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 3) FOR ALL OF THE UNITS DEMOLITION NOTE # 1 INDICATES
 THE REMOVAL OF THE DRYWALL AND INSULATION ON ALL OF THE
 EXTERIOR WALLS. THERE ARE ALSO NOTES FOR NEW TRANE FAN
 COIL UNITS. IN THIS SUBMISSION THERE HAS BEEN NO
 DOCUMENTATION TO THE 2014 ENERGY CODE.
 C401.2 APPLICATION. COMMERCIAL BUILDINGS SHALL COMPLY
 WITH ONE OF THE FOLLOWING:
 3.1. THE REQUIREMENTS OF ANSI/ASHRAE/IESNA 90.1.
 3.2. THE REQUIREMENTS OF SECTIONS C402, C403, C404 AND
 C405. IN ADDITION, COMMERCIAL BUILDINGS SHALL COMPLY
 WITH EITHER SECTION C406.2, C406.3 OR C406.4.
 3.3. THE REQUIREMENTS OF SECTION C407, C402.4, C403.2,
 C404, C405.2, C405.3, C405.4, C405.6 AND C405.7. THE
 BUILDING ENERGY COST SHALL BE EQUAL TO OR LESS THAN 85
 PERCENT OF THE STANDARD REFERENCE DESIGN BUILDING.
  
 4) SHEET A-5 SHOWS THIS DORMITORY AS THE ACCESSIBLE
 UNIT. THE DESIGNER OF RECORD SHOWS ON THE PLANS THE USE
 OF AN ELECTRONIC DOOR OPENER TO GAIN ACCESS INTO THE
 ACCESSIBLE DORM. THE QUESTION IS HOW TO MAKE THE
 BATHROOM A FULLY ACCESSIBLE BATHROOM AND OR STALL? THE
 PLANS SHOW A CODE COMPLIANT SHOW A COMPLIANT TRANSFER
 SHOWER, LAVATORY AND MIRROR BUT NOT WATER CLOSET. 604.8
 ACCESS. CODE FBC 2014.
  
 5) PLEASE PROVIDE WHERE CODE COMPLIANCE CAN BE FOUND
 FOR THE 2014 FBC-ACCESS. CODE ) FBC-ACCESS. CODE 224.4
 GUEST ROOMS WITH COMMUNICATION FEATURES. IN TRANSIENT
 LODGING FACILITIES, GUEST ROOMS WITH COMMUNICATION
 FEATURES COMPLYING WITH 806.3 SHALL BE PROVIDED IN
 ACCORDANCE WITH TABLE 224.4.
  
 6) ) WHEN RESUBMITTING PLANS PLEASE INDICATE THE
 REVISION & REMOVE ANY VOIDED SHEETS & REPLACE ANY PAGES
 AS NECESSARY. A TRANSMITTAL LETTER LISTING THE ORIGINAL
 REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF THE
 REVISION MADE, IDENTIFYING THE SHEET OR SPECIFICATION
 PAGE WHERE THE CHANGES CAN BE FOUND WILL HELP TO
 EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 JAMES A. WITMER CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION
 DEVELOPMENT SERVICES DEPARTMENT
 TEL: 561-805-6715
 E-MAIL: [email protected]
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-06-06 Cont ID  
Sent By jpearson Date 2017-06-06 Time 08:32 Rev Time 0.00
Received By jpearson Date 2017-06-06 Time 08:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-05-11 Cont ID  
Sent By jleahy Date 2017-05-11 Time 12:15 Rev Time 0.00
Received By jleahy Date 2017-05-11 Time 11:55 Sent To  
Notes
2017-05-11 12:16:00JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 LEVEL 1 ALTERATION
  
 R314.3 LOCATION.
 SMOKE ALARMS SHALL BE INSTALLED IN THE FOLLOWING
 LOCATIONS:
  
 1. IN EACH SLEEPING ROOM.
  
 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
 VICINITY OF THE BEDROOMS.
  
 R314.3.1 ALTERATIONS, REPAIRS AND ADDITIONS.
 WHEN ALTERATIONS, REPAIRS OR ADDITIONS REQUIRING A
 PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
 ADDED OR CREATED IN EXISTING DWELLINGS, THE INDIVIDUAL
 DWELLING UNIT SHALL BE EQUIPPED WITH SMOKE ALARMS
 LOCATED AS REQUIRED FOR NEW DWELLINGS.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2017-05-31 Cont ID  
Sent By pleduc Date 2017-05-31 Time   Rev Time 0.00
Received By pleduc Date 2017-05-30 Time 14:52 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2017-04-28 Cont ID  
Sent By pleduc Date 2017-04-28 Time   Rev Time 0.00
Received By pleduc Date 2017-04-28 Time 09:16 Sent To  
Notes
2017-04-28 15:33:57THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC,
 FIRE MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 PLEASE CONSIDER THE FOLLOWING AS PROVISO:
  
 THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED
 AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE
 PROVISO COMMENTS WILL RESULT IN A FAILED FIRE
 INSPECTION.
  
  
 1) THE CARD READER INSTALLATIONS SHALL NOT RESTRICT
 EGRESS UNDER ANY CONDITIONS. CARD READERS ON EXIT DOORS
 SHALL COMPLY WITH NFPA 101, CHAPTER 7, MEANS OF EGRESS.
  
  
 2) CARD READERS SHALL BE INSTALLED UNDER SEPARATE SHOP
 DRAWINGS.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2017-06-08 Time   Rev Time 0.00
Received By lmarchan Date 2017-06-06 Time 14:04 Sent To  
Notes
2017-06-07 14:05:07RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-06-06 Cont ID  
Sent By jpearson Date 2017-06-06 Time 08:36 Rev Time 0.00
Received By jpearson Date 2017-05-26 Time 09:26 Sent To  
Notes
2017-05-30 09:26:35C19

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-11 Cont ID  
Sent By jleahy Date 2017-05-11 Time 12:25 Rev Time 0.00
Received By jleahy Date 2017-04-21 Time 15:37 Sent To  
Notes
2017-04-24 15:37:50C12

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2017-05-09 Cont ID  
Sent By jwitmer Date 2017-05-09 Time 11:47 Rev Time 0.00
Received By jwitmer Date 2017-05-05 Time 17:02 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2017-06-08 Cont ID  
Sent By ccole Date 2017-06-08 Time 15:47 Rev Time 0.00
Received By ccole Date 2017-06-08 Time 15:12 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-06-01 Cont ID  
Sent By ccole Date 2017-06-01 Time 07:27 Rev Time 0.00
Received By ccole Date 2017-06-01 Time 07:02 Sent To  
Notes
2017-06-01 07:28:181ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17040981
 6/1/17
  
 RESULTS: DENIED.
  
 1) THE REQUESTED AC CHANGEOUT FORMS AND AHRI
 CERTIFICATES FOR THE FAN COIL UNITS WERE NOT SUBMITTED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-04-27 Cont ID  
Sent By ccole Date 2017-04-27 Time 09:33 Rev Time 0.00
Received By ccole Date 2017-04-27 Time 07:53 Sent To  
Notes
2017-04-27 09:51:111ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17040981
 4/27/16
  
 1) SHEETS MP-1, SUITE 310: KEYED NOTE #2 WHICH
 DESIGNATES AN EXHAUST FAN IS SHOWN AT THE FAN COIL
 LOCATIONS IN THE BEDROOMS. PLEASE CORRECT, AND REVISE
 KEYED NOTE #3 WHICH IS REFERENCING A FAN COIL UNIT
 UNDER KEYED NOTE #2.
  
 2) MP-4 & MP-5: REVISE KEYED NOTE #3 WHICH IS
 REFERENCING A FAN COIL UNIT UNDER KEYED NOTE #2 NEEDS
 TO BE REVISED.
  
 3) PROVIDE AC CHANGE OUT FORMS AND AHRI CERTIFICATES
 FOR ALL FAN COIL UNITS BEING REPLACED.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-06-05 Cont ID  
Sent By tklarge Date 2017-06-05 Time 14:49 Rev Time 0.00
Received By tklarge Date 2017-06-05 Time 14:27 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-05-05 Cont ID  
Sent By gjohnson Date 2017-05-05 Time 13:23 Rev Time 0.00
Received By gjohnson Date 2017-05-04 Time 11:45 Sent To  
Notes
***NONE***