Plan Review Details - Permit 17040807
| Plan Review Stops For Permit 17040807 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2018-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-03-22 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-22 |
Time |
11:12 |
Sent To |
I |
|
| Notes |
| 2018-03-22 11:13:18 | ****PROVISOS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | 1. ACCESSIBLE SIGHT LINE REQUIRED PER FBC | | | ACCCESSIBILITY 802. LOCATION OF ACCESSIBLE SEATING, | | | SIGHT LINES, COMPANION SEATING NOT CLEAR. PRIOR TO | | | INSTALLATION OR C.O., THIS INFORMATION IS REQUIRED TO | | | BE SUBMITTED AND REVIEWED. SUBJECT TO THE FIELD | | | INSPECTOR'S DISCRETION, HE OR SHE MAY WAIVE THE | | | REQUIREMENT. | | | | | | 2. SHEET A0.05 AND OTHER SHEETS, A3 OCCUPANCY DECLARED. | | | THIS APPEARS TO BE A2 OCCUPANCY. REVISE PLAN, SUBMIT AS | | | A REVISION, OR HAVE ARCHITECT SEND RATIONALE FOR A3 | | | OCCUPANCY VIA EMAIL. THIS IS REQUIRED PRIOR TO C.O. | | | | | | 3. THIS IS A THRESHOLD BUILDING PER FS 553. THREE SETS | | | OF PLANS ARE REQUIRED. AS ONLY TWO SETS WERE SUBMITTED, | | | HAVE A SET COPIED AFTER PERMIT ISSUANCE. THIS CAN BE | | | DONE IN BLACK & WHITE, CANNOT BE USED FOR INSPECTION | | | PURPOSES. | | | | | | 4. PRODUCT APPROVALS FOR COMPONENTS AND CLADDING ARE TO | | | BE SUBMITTED, REVIEWED AND APPROVED PRIOR TO | | | INSTALLATION. PRODUCT APPROVALS ARE TO BE REVIEWED BY | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL TO THE BUILDING | | | DIVISION. | | | | | | 5. SEPARATE PERMITS ARE REQUIRED FOR FIRE ALARM, FIRE | | | SPRINKLER, LANDSCAPING, FENCING, SIGNS, AWNINGS, ETC. - | | | ONLY BUILDING, MEP ARE INCLUDED IN THIS PERMIT. SUB | | | PERMITS REQUIRED FOR ROOF, MEP. | | | | | | 6. IN THE EVENT OF ANY CONFLICT BETWEEN CIVIL SHEETS | | | SUBMITTED TO THE BUILDING DIVISION AND THE ENGINEERING | | | DEPARTMENT, IT IS CONTRACTOR'S RESPONSIBILITY TO | | | CORRELATE. | | | | | | 7. THIS IS A THRESHOLD BUILDING. CONTRACTOR IS TO MAKE | | | A COPY OF THE PLANS STAMPED BY THE CITY FOR USE BY THE | | | THRESHOLD INSPECTOR. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-03-15 |
Time |
15:33 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-15 |
Time |
15:33 |
Sent To |
|
|
| Notes |
| 2018-03-15 15:34:07 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. VALUE IS LOWER THAN ICC TABLES PER SF; PROVIDE | | | CONTRACT AND COST BREAKDOWN FOR REVIEW, OR AGREE FOR | | | VALUE TO BE ADJUSTED TO ICC TABLES. THIS MAY BE | | | ADDRESSED BY EMAIL. | | | | | | 2. PLEASE REMOVE THE STEEL BUILDING PAGES FROM THE | | | SUBMITTAL AS THEY WERE ALREADY APPROVED UNDER THE | | | FOUNDATION/STRUCTURE PERMIT. | | | | | | 3. SEE PREVIOUS LIST REGARDING ACCESSIBLE SIGHT LINE. | | | RESPONSE LETTER STATES THAT THIS IS ON THE "A" SHEETS, | | | BUT I WAS UNABLE TO LOCATE THIS INFORMATION. THIS | | | PERMIT WILL BE PASSED WITH PROVISO, COMPLIANCE | | | REQUIRED, TO BE VERIFIED AT INSPECTION, REVISION | | | REQUIRED SUBJECT TO FIELD INSPECTOR'S DISCRETION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2018-02-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-26 |
Time |
17:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-02-12 |
Time |
06:21 |
Sent To |
|
|
| Notes |
| 2018-02-28 06:49:54 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. VALUE IS LOWER THAN ICC TABLES PER SF; PROVIDE | | | CONTRACT AND COST BREAKDOWN FOR REVIEW, OR AGREE FOR | | | VALUE TO BE ADJUSTED TO ICC TABLES. THIS MAY BE | | | ADDRESSED BY EMAIL. | | | | | | 2. PLEASE REMOVE THE STEEL BUILDING PAGES FROM THE | | | SUBMITTAL AS THEY WERE ALREADY APPROVED UNDER THE | | | FOUNDATION/STRUCTURE PERMIT. | | | | | | 3. SEE PREVIOUS LIST REGARDING ACCESSIBLE SIGHT LINE. | | | RESPONSE LETTER STATES THAT THIS IS ON THE "A" SHEETS, | | | BUT I WAS UNABLE TO LOCATE THIS INFORMATION. THIS | | | PERMIT WILL BE PASSED WITH PROVISO, COMPLIANCE | | | REQUIRED, TO BE VERIFIED AT INSPECTION, REVISION | | | REQUIRED SUBJECT TO FIELD INSPECTOR'S DISCRETION. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-22 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-14 |
Time |
12:11 |
Sent To |
|
|
| Notes |
| 2017-09-22 08:59:48 | ***CORRECTIONS*** | | | REVISED 9/26/17 (ITEM #1) | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | GREENE SCHOOL CLASSROOM & GYMNASIUM EXPANSION | | | REVIEW #2 | | | | | | COMMENTS FROM PREVIOUS LIST: | | | | | | 1. A GEOTECHNICAL REPORT IS REQUIRED, FBC B 1803.1. | | | SEOR IS TO REVIEW THE SOILS REPORT; PROVIDE A SHOP | | | DRAWING REVIEW, A REVIEW LETTER, OR INCORPORATE | | | REFERENCE INTO THE PLAN. THE REPORT SUBMITTED IS FOR A | | | PROJECT AT ANOTHER LOCATION; IT IS NOT CLEAR WHY THIS | | | WAS SUBMITTED, FBC B 1803.1, FBC 107. | | | | | | 2ND REVIEW, TWO SOILS REPORTS PROVIDED, THREE REQUIRED. | | | ADVISE AS TO WHERE STRUCTURAL ENGINEER OF RECORD'S | | | REVIEW CAN BE FOUND. IF NOT IN THE PLAN, PROVIDE A | | | LETTER OR SHOP DRAWING REVIEW STAMP ON THE SOILS | | | REPORT, FBC 107. | | | | | | **REVISED ON 9/26/17: IF THE FOUNDATION PERMIT 17060234 | | | HAS BEEN ISSUED PRIOR TO NEXT REVIEW FOR THIS PERMIT, | | | THE SOILS REPORT WILL NOT REQUIRED TO BE SUBMITTED AS | | | IT WILL BE A PART OF THE PERMIT RECORD. REVIEW BY SEOR | | | IS STILL REQUIRED.** | | | | | | 2-5. OK | | | | | | 6. A SITE PLAN PREPARED BY A DESIGN PROFESSIONAL IS | | | REQUIRED TO SHOW COMPLIANCE WITH FBC B TABLES 602, 705. | | | THE SITE PLAN SUBMITTED IS NOT SIGNED AND SEALED AND | | | DOES NOT INCLUDE THIS INFORMATION. | | | | | | 2ND REVIEW, SHEET A1.01 DOES NOT INCLUDE DIMENSIONS TO | | | THE (PROPOSED NEW) PROPERTY LINES OR CENTERLINE OF | | | STREET AS APPLICABLE. SEE FBC B TABLES 602, 705. | | | | | | 7. FBC 109, PROJECT VALUE NOT CLEAR. A COPY OF THE | | | CONTRACT, COST BREAKDOWN, OTHER INFORMATION MAY BE | | | REQUIRED. AS SCOPE IS NOT CLEAR, A VALUATION ADJUSTMENT | | | MAY BE DONE AT TIME OF 2ND REVIEW. | | | | | | 2ND REVIEW, PROVIDE A COPY OF THE CONTRACT FOR THIS | | | JOB. VALUE APPEARS LOW. A COST BREAKDOWN MAY BE | | | REQUIRED. | | | | | | 8. SEE PREVIOUS LIST REGARDING FBC B 503 COMPLIANCE. | | | BUILDING APPEARS TO BE COMPLIANT BUT INFORMATION ON THE | | | PLAN IS NOT CORRECT. SHEET A0.02 AND OTHER LOCATIONS, | | | REVISE THE FOLLOWING (AND CHECK ALL): | | | | | | TYPE IIB AND TYPE IIIB CONSTRUCTION DECLARED (APPEARS | | | TO BE TYPE IIIB, REVIEWED AS SUCH). REVISE; ONLY ONE IS | | | APPLICABLE. | | | A5 OCCUPANCY DECLARED; THIS IS FOR OUTDOOR SPORTS, | | | REVISE, FBC B 303.5, 303.6. | | | | | | 9. OK - UPDATE OCCUPANT LOAD IF ASSEMBLY OCC LOAD IS | | | INCREASED | | | | | | 10-11. OK | | | | | | 12. SEATING AND SIGHT LINES FOR ASSEMBLY SEATING NOT | | | CLEAR, REVISE PLAN TO CLARIFY FBC A 802. REVISE PLAN TO | | | PROVIDE MORE INFORMATION ABOUT HOW THE SPACE WILL BE | | | USED. IT APPEARS THAT COMPANION SEATING MAY ALSO BE | | | REQUIRED. IF BLEACHER STYLE SEATING IS INCLUDED, WILL | | | THE EXCEPTION OF FBC B 1006.2 BE USED? NO ELECTRICAL | | | PLAN SUBMITTED; NOT ENOUGH INFORMATION PROVIDED TO | | | DETERMINE CODE COMPLIANCE. | | | | | | 2ND REVIEW, NOT CLEAR HOW THIS HAS BEEN ADDRESSED. | | | | | | 13. OK | | | | | | 14. 2ND REVIEW, SHEET A1.01 SHOWS A SAFE DISPERSAL AREA | | | FBC B 1027.5 EXCEPTION (TO REQUIREMENT FOR EXIT | | | DISCHARGE TO THE PUBLIC WAY). IF OCCUPANT LOAD IS | | | INCREASED DUE TO OTHER COMMENTS, REVISE THIS PAGE. | | | ALSO, REVISE THE PLAN TO LABEL THE ROW OF RECTANGLES | | | (NOT CLEAR WHAT THIS IS). | | | | | | 15. FBC A 207, REVISE PLAN TO DECLARE METHOD OF | | | ACCESSIBLE MEANS OF EGRESS SELECTED. REVISE PLAN TO | | | SHOW COMPLIANCE; SEE ALSO COMMENT #14. | | | | | | 2ND REVIEW, NOT CLEAR HOW THIS WAS ADDRESSED. IBC2000 | | | OR IBC2003? | | | | | | 16. THIS PERMIT WILL BE ISSUED WITH PROVISO, COMPLIANCE | | | WITH MEANS OF EGRESS ILLUMINATION, INCLUDING EXIT | | | DISCHARGE TO THE PUBLIC WAY, IS TO COMPLY WITH FBC B | | | 1006.1. THIS WILL BE VERIFIED PRIOR TO C.O. REVISE PLAN | | | TO NOTE REQUIREMENT. | | | | | | 17-20. OK | | | | | | 21. ENERGY CALCS WERE PROVIDED BUT APPEAR INCOMPLETE. | | | INPUT REPORT DOES NOT SHOW WALLS, DOORS, WINDOWS, | | | FENESTRATION, ROOF, ETC. FBC EC 103. | | | | | | NEW COMMENTS: | | | | | | 22. SHEET A0.02, A0.03, POSSIBLY OTHER SHEETS, IT IS | | | NOT CLEAR WHAT WORK IS EXISTING, COVERED BY OTHER | | | PERMIT(S), OR PROPOSED UNDER THIS PERMIT. VERIFY THAT | | | THE NORTH INDICATOR IS CORRECT ON ALL SHEETS. THE FLOOR | | | PLAN FOR EXISTING BUILDING HAS NOT BEEN REVIEWED AT | | | THIS TIME. IF THIS IS TO BE INCLUDED IN THE SCOPE OF | | | THIS PERMIT, REVISE PLAN TO INDICATE WHAT WORK IS | | | PROPOSED. IF THIS WAS PROVIDED FOR INFORMATION ONLY, | | | PLEASE LABEL AS SUCH. | | | | | | 23. A0.04, SEE FIRE COMMENTS, FBC B 1004, PROVIDE | | | RATIONALE FOR 15SF PER PERSON FOR THE GYMNASIUM. NO | | | SEATING IS SHOWN. FOR ALL ASSEMBLY AREAS (PROPOSED, AND | | | WHAT MAY BE EXISTING) THE PLAN LACKS CLARIFICATION | | | REGARDING THE USE OF THE SPACES. | | | | | | F0R INSTANCE, GYMANSIUM; WILL THIS BE USED FOR ANY | | | PURPOSE OTHER THAN A BASKETBALL COURT WHICH IS SHOWN | | | GRAPHICALLY?. | | | | | | A0.02, WHAT IS THE USE OF THE 1,315 SF ASSEMBLY SPACE? | | | | | | 24. A0.05 AND OTHER SHEETS, WHAT IS THE USE OF THE "FAB | | | LAB", FBC 107, REVISE PLAN TO INCLUDE DESCRIPTON. | | | A0.04, A0.05, POSSIBLY OTHER LOCATIONS, TEACHER | | | PLANNING ROOM TEXT NOT LEGIBLE, REVISE. | | | | | | 25. VESTIBULES 109A, 208A, REVISE PLAN TO SHOW 18" | | | MANEUVERING CLEARANCE REQUIRED BY FBC A | | | | | | 26. 3-A5.51 INCLUDES A REFERENCE TO "FBC 2015", REVISE | | | AND CHECK ALL. | | | | | | 27. FBC ACCESSIBILITY, PROVIDE DETAILS FOR BATHROOMS | | | AND FIXTURES. | | | | | | 28. FBC A 212.3, SHEET A 5.51, CLARIFY LOCATION OF | | | SINKS DETAILS 2 AND 3. | | | | | | 29. THREE COMPLETE IDENTICAL COLLATED SETS OF PERMIT | | | DOCUMENTS AND PLANS REQUIRED, FBC 107. FAILURE TO | | | PROVIDE THREE SETS FOR EACH REVIEW CYCLE MAY RESULT IN | | | DELAY AT TIME OF ISSUANCE. | | | | | | 30. THE DELEGATED ENGINEERING (BUILDING SHELL) IS | | | REQUIRED TO BE SIGNED, SEALED, DATED ORIGINALS, FS471. | | | THEY ARE TO BE REVIEWED BY STRUCTURAL ENGINEER OF | | | RECORD PRIOR TO SUBMITTAL. THEY MAY BE PROVIDED IN THE | | | NEXT SUBMITTAL OR MAY BE A DEFERRED SUBMITTAL | | | (SUBMITTED, REVIEWED, AND ISSUED PRIOR TO | | | INSTALLATION). | | | | | | 31. FBC B TABLE 1607.1(26), SHEET S002 AND E1 OF 68, | | | 300# CONCENTRATED REQUIRED FOR ROOF, REVISE. | | | | | | 32. FBC 107, PROVIDE THE COVER SHEET FOR EACH FLORIDA | | | STATE PRODUCT APPROVAL. THIS WAS PROVIDED FOR SOME BUT | | | NOT ALL OF THE PRODUCT APPROVALS. ALL PRODUCT APPROVALS | | | AND RELATED INFORMATION (METHOD OF FASTENING PROPOSED) | | | MAY BE A DEFERRED SUBMITTAL. | | | | | | 33. VERIFY THAT PRODUCT APPROVALS HAVE PRINTED | | | PROPERLY; SEE NOA 16-0208.08. | | | | | | 34. ROOF DECK PRODUCT APPROVALS, WALL PANEL PRODUCT | | | APPROVALS, INDICATE WHICH METHOD OF FASTENING IS | | | PROPOSED, FBC B 1609. THIS MAY BE A DEFERRED SUBMITTAL. | | | | | | 34. WHEN RESUBMITTING, PROVIDE THREE IDENTICAL COLLATED | | | SETS OF PLANS AND PERMIT DOCUMENTS. THE SUPPORTING | | | DOCUMENTS MAY BE IN A BINDER BUT IF SUBMITTED IN THIS | | | MANNER SHOULD HAVE THREE BINDERS. REMOVE OLD SHEETS | | | FROM THE BOUND SETS, MARK VOID AND RETAIN IN THE | | | SUBMITTAL (BUT NOT IN THE PLANS FOR PERMIT ISSUANCE). | | | ALL CHANGES SHOULD BE CLOUDED AND MARKED WITH REVISION | | | #. | | | | | | 35. FS553.80(2)(B), WITH RESPECT TO EVALUATION OF | | | DESIGN PROFESSIONALS? DOCUMENTS, IF A LOCAL GOVERNMENT | | | FINDS IT NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH | | | THE FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | | REVIEW. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-02 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-02 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-27 |
Time |
07:32 |
Sent To |
|
|
| Notes |
| 2017-05-02 09:16:18 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | GREENE SCHOOL CLASSROOM & GYMNASIUM EXPANSION | | | | | | 1. A GEOTECHNICAL REPORT IS REQUIRED, FBC B 1803.1. | | | SEOR IS TO REVIEW THE SOILS REPORT; PROVIDE A SHOP | | | DRAWING REVIEW, A REVIEW LETTER, OR INCORPORATE | | | REFERENCE INTO THE PLAN. | | | | | | THE REPORT SUBMITTED IS FOR A PROJECT AT ANOTHER | | | LOCATION; IT IS NOT CLEAR WHY THIS WAS SUBMITTED, FBC B | | | 1803.1, FBC 107. | | | | | | 3. SCOPE NOT CLEAR. THE APPLICATION IS FOR "PROPOSED | | | NEW CLASSROOM & GYMNASIUM ADDITION TO EXIST. SCHOOL". | | | THE EXPEDITED REVIEW REQUEST STATES "FOUNDATION & | | | FOOTING/DEMO PER DISCUSSION W/JIM WITMER." THE COVER | | | PAGE T1 APPEARS TO BE FOR THE COMPLETE BUILDING. OTHER | | | PAGES STATE "REVIEW SET - SHELL & FOUNDATION | | | DOCUMENTS." SOME OF THE FOLLOWING COMMENTS MAY NOT BE | | | APPLICABLE; AN ACCURATE REVIEW CANNOT BE DONE WITHOUT | | | KNOWING SCOPE OF THIS PERMIT. | | | | | | IT IS NOT CLEAR WHETHER THIS APPLICATION IS FOR THE | | | FOUNDATION, STRUCTURE, OR BUILDING. | | | | | | IF YOU WOULD LIKE TO OBTAIN A FOUNDATION PERMIT, THE | | | FOLLOWING IS REQUIRED: | | | | | | PERMIT APPLICATION WHICH STATES SCOPE (FOR FOUNDATION | | | PERMIT, TYPICALLY FOOTINGS OR FOOTINGS AND SLAB) | | | GEOTECHNICAL REPORT | | | SURVEY DRAWING | | | STORM WATER POLLUTION PREVENTION PLAN | | | SITE PLAN | | | 1ST FLOOR ARCHITECTURAL PLAN | | | ARCHITECTURAL CROSS SECTION(S) OF THE BUILDING | | | FOUNDATION PLAN | | | FOUNDATION DETAILS AND CROSS SECTIONS | | | STRUCTURAL ENGINEER'S GENERAL NOTES | | | UNDERGROUND PLUMBING PLAN (IF APPLICABLE) | | | ELECTRICAL PLAN SHOWING ANY UNDERGROUND CONDUIT (IF | | | APPLICABLE) | | | ELECTRICAL GROUNDING TO STEEL DETAIL, IF APPLICABLE (OR | | | EXPLAIN WHY THIS IS NOT APPLICABLE FOR THIS PROJECT). | | | IF REQUIRED, A DETAIL IS REQUIRED AS A REVIEW, PERMIT, | | | AND INSPECTION ARE REQUIRED PRIOR TO CONCRETE POUR | | | PLAN SHOWING UNDERGROUND FIRE LINE | | | THRESHOLD INSPECTION PLAN OR RESIDENT INSPECTION PLAN | | | (AS APPLICABLE) | | | | | | 4. EXPEDITED REVIEW REQUESTS THAT "DEMO" IS PART OF THE | | | SCOPE. IF THIS IS FOR A FREE STANDING BUILDING WHICH | | | NEEDS TO BE DEMOLISHED, THIS REQUIRES A SEPARATE | | | PERMIT. SUBMIT A BUILDING PERMIT APPLICATION AND THE | | | INFORMATION REQUIRED BY THE DEMOLITION APPLICATION, | | | DEMOLITION DEBRIS DISPOSAL FEE, AND DEMOLITION PERMIT | | | APPLICATION CHECKLIST. | | | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | | UILDING-PERMIT-FORMS | | | | | | IF DEMOLITION IS LIMITED TO THE NOTES ON SHEET A1.00, | | | WORK WITHIN THE PROPERTY BOUNDARY WILL BE INCLUDED IN | | | THIS PERMIT. | | | | | | 5. THE PROPOSED IMPROVEMENT APPEARS TO CROSS PROPERTY | | | LINES. IS A REPLAT OR UNITY OF TITLE PROPOSED? FBC | | | CHAPTER 7, PROVIDE INFORMATION REGARDING THE REPLAT OR | | | UNITY. | | | | | | THIS PERMIT WILL BE ISSUED WITH PROVISO, REPLAT OR | | | UNITY OF TITLE (AS APPLICABLE) REQUIRED PRIOR TO C.O. | | | | | | 6. A SITE PLAN PREPARED BY A DESIGN PROFESSIONAL IS | | | REQUIRED TO SHOW COMPLIANCE WITH FBC B TABLES 602, 705. | | | THE SITE PLAN SUBMITTED IS NOT SIGNED AND SEALED AND | | | DOES NOT INCLUDE THIS INFORMATION. | | | | | | 7. FBC 109, PROJECT VALUE NOT CLEAR. A COPY OF THE | | | CONTRACT, COST BREAKDOWN, OTHER INFORMATION MAY BE | | | REQUIRED. AS SCOPE IS NOT CLEAR, A VALUATION ADJUSTMENT | | | MAY BE DONE AT TIME OF 2ND REVIEW. | | | | | | 8. COMPLIANCE WITH FBC B TABLE 503 NOT CLEAR. SHEET | | | A0.02 DECLARES TYPE III B CONSTRUCTION, 54,375 SF | | | REQUIRED. HOW HAS THIS NUMBER BEEN ASCERTAINED? REVISE | | | PLAN TO INCLUDE AREA INCREASE CALCULATIONS FBC B 506. | | | | | | IT IS NOT CLEAR IF THIS IS MIXED USE, SEPARATED OR | | | MIXED USE, NON SEPARATED. PLAN NOTES THAT SEPARATION | | | BETWEEN A AND E IS 0, BUT DOES NOT INCLUDE BUSINESS | | | WHICH REQUIRES FIRE RATED SEPARATION IF THIS IS MIXED | | | USE, SEPARATED. | | | | | | 9. REVISE PLAN TO INCLUDE OCCUPANT LOAD TOTALS, SQUARE | | | FOOT AREA TOTALS (OCCUPANCY ANALYSIS), FBC 107. THIS | | | INFORMATION IS REQUIRED TO PRINT ON THE C.O. | | | | | | 10. SUBMIT FIRE SPRINKLER PLANS, FBC 107.3.5.1.1. | | | | | | 11. FBC A 201, 202.2, 206.3, CLARIFY THE GENERAL | | | CIRCULATION PATH AND THE ACCESSIBLE ROUTE. REVISE PLAN | | | TO SHOW COMPLIANCE WITH THE REQUIREMENT OF FBC A 206.3 | | | "ACCESSIBLE ROUTES SHAL COINCIDE WITH OR BE LOCATED IN | | | THE SAME AREA AS GENERAL CIRCULATION PATHS. WHERE | | | CIRCULATION PATHS ARE INTERIOR, REQUIRED ACCESSIBLE | | | ROUTES SHALL ALSO BE INTERIOR." | | | | | | IT APPEARS THAT THE GENERAL CIRCULATION PATH FOR | | | OCCUPANTS IN THE FIRST FLOOR ADDITION WHO SUBSEQUENTLY | | | WISH TO ACCESS THE SECOND FLOOR VIA STAIRS HAS AN | | | INTERIOR ROUTE VIA STAIRS, BUT IT APPEARS THAT AN | | | OCCUPANT UNABLE TO UTILIZE STAIRS IS COMPELLED TO EXIT | | | THE BUILDING TO ACCESS THE ELEVATOR. | | | | | | REVISE PLAN TO CLARIFY THE GENERAL CIRCULATION PATH, | | | SHOW COMPLIANCE WITH THE REQUIREMENT THAT THE ROUTE | | | COINCIDES AND IS INTERIOR. | | | | | | FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS. | | | | | | 12. SEATING AND SIGHT LINES FOR ASSEMBLY SEATING NOT | | | CLEAR, REVISE PLAN TO CLARIFY FBC A 802. REVISE PLAN TO | | | PROVIDE MORE INFORMATION ABOUT HOW THE SPACE WILL BE | | | USED. IT APPEARS THAT COMPANION SEATING MAY ALSO BE | | | REQUIRED. IF BLEACHER STYLE SEATING IS INCLUDED, WILL | | | THE EXCEPTION OF FBC B 1006.2 BE USED? NO ELECTRICAL | | | PLAN SUBMITTED; NOT ENOUGH INFORMATION PROVIDED TO | | | DETERMINE CODE COMPLIANCE. | | | | | | 13. THE AREA OVER THE GYM IS CALLED A SECOND FLOOR IN | | | SOME PLACES AND A MEZZANINE IN OTHERS. REVISE PLAN TO | | | DEFINE WHETHER THIS IS TO BE TREATED AS A MEZZANINE OR | | | SECOND FLOOR, SEE FBC B 505 (MEZZANINES), 404 | | | (ATRIUMS), REVISE PLAN TO SHOW COMPLIANCE, INCLUDING | | | APPLICABLE EXCEPTIONS UTILIZED. | | | | | | 14. THE LIFE SAFETY PLAN IS NOT CLEAR AS TO EXIT | | | DISCHARGE TO THE PUBLIC WAY, REVISE TO INCLUDE OR | | | PROVIDE ANOTHER SHEET WHICH CLARIFIES, FBC B 1027. THE | | | SITE PLAN PROVIDED IS NOT SIGNED AND SEALED AND | | | THEREFORE CANNOT BE USED TO SHOW CODE COMPLIANCE. | | | | | | 15. FBC A 207, REVISE PLAN TO DECLARE METHOD OF | | | ACCESSIBLE MEANS OF EGRESS SELECTED. REVISE PLAN TO | | | SHOW COMPLIANCE; SEE ALSO COMMENT #14. | | | | | | 16. THIS PERMIT WILL BE ISSUED WITH PROVISO, COMPLIANCE | | | WITH MEANS OF EGRESS ILLUMINATION, INCLUDING EXIT | | | DISCHARGE TO THE PUBLIC WAY, IS TO COMPLY WITH FBC B | | | 1006.1. THIS WILL BE VERIFIED PRIOR TO C.O. REVISE PLAN | | | TO NOTE REQUIREMENT. | | | | | | 17. FBC 481.321, ALL FINAL PLANS, SPECIFICATIONS, OR | | | REPORTS PREPARED OR ISSUED BY THE REGISTERED LANDSCAPE | | | ARCHITECT AND FILED FOR PUBLIC RECORD SHALL BE SIGNED | | | BY THE REGISTERED LANDSCAPE ARCHITECT, DATED, AND | | | STAMPED OR SEALED ELECTRONICALLY WITH HER OR HIS SEAL. | | | THE PAGES WHICH APPEAR TO BE PREPARED BY JON E. SCHMIDT | | | AND ASSOCIATES ARE NOT SIGNED AND SEALED. | | | | | | 18. A0.13, DOOR HARDWARE INFORMATION IS LACKING. FBC B | | | 1008.1.10, NOTE PANIC OR FIRE EXIT HARDWARE REQUIRED. | | | | | | 19. A0.2 OCCUPANCY ANALYSIS SQUARE FEET TOTALS 19,553 | | | (11,901 1ST FLOOR, 7,652 2ND FLOOR); THERE IS A | | | DISCREPANCY OF 9,339, REVISE PLAN TO CLARIFY. | | | | | | 20. A0.2 BUSINESS AREAS ARE SHOWN AS 3 OCCUPANTS BUT | | | ARE OVER 300 SF; PLEASE REVISE TO 4, REVISE ANY OTHER | | | FRACTION OF OCCUPANTS UP RATHER THAN DOWN, FBC 1004. | | | | | | 21. FBC EC 103, SUBMIT ENERGY CALCS. THIS IS REQUIRED | | | FOR A PERMIT FOR BOTH THE BUILDING AND STRUCTURE (SCOPE | | | UNDER THIS PERMIT NOT CLEAR AT THIS TIME). THIS IS NOT | | | REQUIRED FOR A FOUNDATION ONLY. | | | | | | 22. SEE IMPACT FEE REVIEW. | | | | | | 23. SEE THRESHOLD REVIEW. THRESHOLD STATEMENT TO BE ON | | | ALL PLANS PREPARED BY ARCHITECT AND ENGINEER OF RECORD; | | | THREE SETS REQUIRED; SI REQUIRED, SEE THRESHOLD REVIEW | | | FOR SPECIFIC REQUIREMENTS. | | | | | | 24. FBC 107, THREE COMPLETE SETS OF PLANS AND PERMIT | | | DOCUMENTS REQUIRED. | | | | | | 25. THE SIGNATURE OBSCURES THE ARCHITECT'S PRINTED NAME | | | AND LICENSE NUMBER; PLEASE RELOCATE THIS INFORMATION OR | | | THE SIGNATURE AND SEAL, FS481. PLEASE DO THIS ONLY FOR | | | SHEETS WHICH CHANGE. | | | | | | 26. INDEX SHEET STATES THAT MEP IS NOT APPLICABLE FOR | | | THIS SUBMISSION. IF THIS IS AN APPLICATION FOR THE | | | BUILDING, PROVIDE PLANS, FBC 107. A COMPLETE REVIEW | | | CANNOT BE DONE AT THIS TIME DUE TO INSUFFICIENT | | | INFORMATION. | | | | | | 27. MYFLORIDALICENSE.COM DOES NOT SHOW THAT ANDREW | | | MORGAN, PE HAS TAKEN THE ADVANCED FBC COURSE REQUIRED | | | BY FS 471.0195, PLEASE ADDRESS (PROVIDE EVIDENCE THAT | | | THE COURSE WAS TAKEN TO FBPE, REQUEST THAT THE DBPR | | | WEBSITE BE UPDATED). | | | | | | 28. PERMIT APPLICATION 16080972 IS EXPIRED/ABANDONED; | | | ADDRESS. OTHER PERMITS ARE ALSO EXPIRED OR APPEAR TO | | | EXPIRE SOON, PLEASE ADDRESS AT THIS TIME - FOR | | | INSTANCE, 16061325. THIS COMMENT WILL NOT DELAY PERMIT | | | ISSUANCE, BUT PLEASE ADVISE AS TO HOW THIS IS BEING | | | ADDRESSED. | | | | | | 29. S002, REVISE LOAD CHART TO INCLUDE 2ND | | | FLOOR/MEZZANINE ASSEMBLY AREA, FBC B TABLE 1607.1. | | | | | | 30. RE: REBAR LAP DIMENSION, S001 NOTE 8 STATES 48 BAR | | | "TYPICALLY", CLARIFY WHEN THIS IS NOT THE CASE OR | | | REVISE NOTE, FBC 107. | | | | | | 31. S401 NOTE 12 PROVIDES A SPEC FOR SHOWER SLAB; IT IS | | | NOT CLEAR WHERE THE SHOWERS ARE LOCATED, REVISE PLAN TO | | | CLARIFY, FBC 107. | | | | | | 32. CONTRACTOR HAS OBJECTED TO THE CLASSIFICATION OF | | | THRESHOLD BUILDING. THIS DETERMINATION WAS MADE PER | | | FS553.71(11) AND INFORMATION PROVIDED BY THE ARCHITECT | | | ON THE PLAN: | | | | | | TWO STORY 28,892 SQUARE FOOT ADDITION TO AN EXISTING | | | 18,374 SQUARE FOOT EXISTING SCHOOL WITH AN | | | OCCUPANT LOAD (ADDITION) OF 658 ON THE 1ST FLOOR,457 ON | | | THE 2ND FLOOR, NO OCCUPANT LOAD/OCCUPANCY | | | CLASSIFICATION INFORMATION PROVIDED FOR THE EXISTING | | | SCHOOL (THAT INFORMATION DOES NOT APPEAR TO BE REQUIRED | | | FOR THIS REVIEW) | | | | | | IF ARCHITECT DISAGREES THAT THIS IS TO BE CLASSIFIED AS | | | A THRESHOLD BUILDING AND IF ARCHITECT ELECTS TO REDUCE | | | THE OCCUPANT LOAD, THEN INFORMATION REGARDING THE | | | EXISTING BUILDING IS REQUIRED - OCCUPANCY | | | CLASSIFICATION BROKEN DOWN BY SQUARE FOOT, OCCUPANT | | | LOAD INCLUDING FACTOR USED PER FBC B TABLE 1004.1.2. | | | | | | NOTE 9, SHEET A0.02 REGARDING THE MAX OCCUPANCY (400 | | | GYMNASIUM, 150 STUDENT CAP) IS ACKNOWLEDGED; HOWEVER, | | | THIS APPEARS TO BE A ZONING OR LOGISTIC CAPACITY WHICH | | | IS NOT TYPICALLY UTILIZED FOR THE PURPOSE OF LIFE | | | SAFETY. | | | | | | IF ARCHITECT DOES NOT AGREE THAT THIS IS A THRESHOLD | | | BUILDING, REVISE PLAN TO DETAIL THE PROPOSED USE OF | | | SPACE(S) AND JUSTIFICATION FOR UTILIZING AN OCCUPANT | | | LOAD LOWER THAN FBC B TABLE 1004.1.2. | | | | | | PLEASE NOTE THAT THE OCCUPANT LOAD ON THE PLAN | | | SUBMITTED COMPLIES WITH THE TABLE AND IS ACCEPTABLE. | | | THIS COMMENT IS MADE PURSUANT TO A NUMBER OF EMAILS | | | FROM THE CONTRACTOR WHEREIN HE OBJECTED TO THE | | | THRESHOLD BUILDING CLASSIFICATION. | | | | | | 33. APPLICABLE TO ALL COMMENTS - IF DESIGN PROFESSIONAL | | | DISAGREES WITH ANY OF THE COMMENTS, PLEASE CONTACT ME | | | TO RESOLVE OR CLARIFY PRIOR TO RESUBMITTAL. | | | | | | 34. CIVIL SHEETS, PARKING LOT, NOT REVIEWED. A SEPARATE | | | PERMIT IS REQUIRED FOR THE PARKING LOT, FBC 107. | | | | | | 35. THE PLANS ARE NOT COMPLETE IF THIS APPLICATION IS | | | FOR A BUILDING (AS PER THE PERMIT APPLICATION). IF THIS | | | IS FOR THE BUILDING, PROVIDE PLANS (ACCESSIBILITY | | | DETAILS, BATHROOMS, MEP, FIRE SPRINKLER, STAIRS, ETC.), | | | FBC 107, FBC B 468. | | | | | | 36. PROVIDE WALL TYPES. S SHEETS HAVE AN IDENTIFIER FOR | | | INTERIOR MASONRY WALLS. FOOTINGS ARE NOTED AS WALL | | | FOOTINGS BUT IT IS NOT CLEAR WHETHER OR NOT THERE ARE | | | WALLS OVER ALL OF THE WALL FOOTINGS, SUCH AS THE | | | BREEZEWAY. UNABLE TO LOCATE WALL TYPES ON A OR S | | | SHEETS. | | | | | | 37. ALL ITEMS OTHER THAN THE BUILDING STRUCTURE, | | | MECHANICAL, ELECTRICAL, AND PLUMBING REQUIRE SEPARATE | | | PERMITS - APPLICATION, PLANS, REVIEWS, FEES. SEPARATE | | | PERMITS ARE REQUIRED FOR PARKING LOT, SITE LIGHTING, | | | SIGNAGE, ETC. | | | | | | SEPARATE SUB PERMITS REQUIRED FOR MECHANICAL, | | | ELECTRICAL, AND PLUMBING; SUBMIT SUB PERMIT APPLICATION | | | PRIOR TO COMMENCEMENT. | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
3 |
Status |
P |
Date |
2018-02-02 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2018-02-02 |
Time |
08:26 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2018-02-02 |
Time |
08:25 |
Sent To |
|
|
| Notes |
| 2018-02-02 08:26:30 | APPROVED WITH EXCEPTION. MUST PROVIDE LOAD CALCULATION | | | FOR EXISTING SERVICE PRIOR TO INSPECTION. NEC 220 |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
F |
Date |
2017-08-31 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-08-31 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-08-31 |
Time |
10:48 |
Sent To |
|
|
| Notes |
| 2017-08-31 10:48:12 | CODES IN EFFECT: | | | FBC = FLORIDA BUILDING CODE 2014 5TH EDITION | | | FBC CE = FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 | | | 5TH EDITION | | | FBC RE = FLORIDA RESIDENTIAL CODE 2014 5TH EDITION, | | | PART VIII ELECTRICAL | | | NEC = NFPA 70 2011 EDITION, NATIONAL ELECTRICAL CODE | | | FS = FLORIDA STATUTES | | | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PROVIDE RECEPTACLE CONTROL REQUIRED BY ASHREA 90.1: | | | 8.4.2. FBC CE 405.7.1 | | | 2. RISER DIAGRAM SHOWS EXISTING SERVICE BEING RE-FEED | | | AND A "PANEL K" BEING ADDED. PROVIDE MORE DETAILS FOR | | | THIS EXISTING SERVICE. WHY IS IT RE-FEED? WHY IS A | | | PANEL BEING ADDED? WHAT IS THIS PANEL FEEDING? SHOW | | | AREA OF WORK FOR PANEL K AND ALL ASSOCIATED | | | INSTALLATION, PROVIDE PANEL SCHEDULE. WHAT IS THE LOAD | | | CALCULATION FOR THIS SERVICE? WHERE IS THIS SERVICE | | | LOCATED? WHAT IS THE DISTANCE FROM NEW CT LOCATION TO | | | EXISTING SERVICE? PROVIDE VOLTAGE DROP CALCULATION. | | | RISER SHOWS 3 SETS OF 4-400 KCMIL WITH A 2/0 EQUIPMENT | | | GROUNDING CONDUCTOR (EGC). WHY DOES THIS CONDUIT HAVE | | | AN EGC? IS THERE A MAIN DISCONNECT NOT SHOWN? WHAT IS | | | THE ROUTING OF THIS CONDUIT WITH WIRES THAT HAVE NO | | | OVERCURRENT PROTECTION? MANY DETAILS ARE NEEDED. FBC | | | 107.2.1 | | | 3. PROVIDE MORE DETAIL FOR THE GROUNDING ELECTRODE | | | SYSTEM. WHERE IS THE EXISTING GE SYSTEM AND HOW WILL | | | THIS SYSTEM BE CONNECTED TO IT? SHOW ALL AVAILABLE | | | GROUNDING ELECTRODES AND THE METHOD OF CONNECTION. NEC | | | 250.50; FBC 107.2.1 | | | 4. PROVIDE A BLOCK NOTE WHERE APPLICABLE INDICATING THE | | | REQUIRED SEPARATE PERMITS AND DATA SPECIFICATION SHEET | | | SUBMITTALS FOR LOW VOLTAGE SYSTEMS, FIRE ALARM, CCTV, | | | PHONE AND DATA, WIRELESS SYSTEMS, WALK-IN COOLERS, | | | HOODS, SOLAR, ETC. FBC 105.1 | | | 5. RISER SHOWS THE TESLA POWERWALL CONNECTED TO PANEL | | | IT, BUT PANEL MDP SHOWS SOLAR TIE IN. PROVIDE | | | CLARIFICATION. NEC 215.5, FBC 107.2.1 | | | 6. PROVIDE AVAILABLE SHORT CIRCUIT CALCULATION FOR EACH | | | PANEL INCLUDING INFORMATION FROM THE POWER COMPANY | | | STATING WHAT THE AVAILABLE SHORT CIRCUIT CURRENT IS FOR | | | THE SERVICE TO CONFIRM THE STATED AIC RATING OF THE | | | SERVICE EQUIPMENT AND DOWNSTREAM PANELS IS ADEQUATE. | | | NEC 110.9, 110.10 | | | 7. PROVIDE NOTES TO INDICATE THE REQUIRED MARKING OF | | | SERVICE EQUIPMENT FOR ARC FLASH HAZARD WARNING AND | | | AVAILABLE FAULT CURRENT PER CODE. NEC 110.16, 110.24 | | | 8. PROVIDE INTERSYSTEM BONDING TERMINATION POINT. NEC | | | 250.94 | | | 9. PROVIDE NOTE THAT EXIT AND EMERGENCY LIGHTS WILL BE | | | CONNECTED TO THE LIGHTING CIRCUIT IN THE AREA AHEAD OF | | | ANY CONTROL. NEC 700.12(F) | | | 10. PROVIDE MANUFACTURERS SPEC SHEETS FOR LIGHT | | | FIXTURES TO CONFIRM LISTING. NEC 110.3 | | | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | | PREVIOUSLY REVIEWED SHEETS. | | | | | | SINCERELY, | | | | | | JOHN PEARSON | | | ELECTRICAL PLANS EXAMINER | | | 561-805-6746 | | | [email protected] | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-04-28 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-04-28 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-04-28 |
Time |
15:42 |
Sent To |
|
|
| Notes |
| 2017-04-28 15:43:10 | JAKE LEAHY | | | ELECTRICAL PLANS EXAMINER II | | | BN1165, BU1753, PX163 | | | 561-805-6713 | | | | | | | | | NO ELECTRICAL SHOWN ON PLANS. |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
2 |
Status |
P |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
mgonzale |
Date |
2017-09-26 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2017-09-26 |
Time |
|
Sent To |
ENG |
|
| Notes |
|
|
| Review Stop |
ENG |
ENGINEERING CSD |
| Rev No |
1 |
Status |
F |
Date |
2017-04-27 |
|
|
Cont ID |
|
| Sent By |
Mgonzale |
Date |
2017-04-27 |
Time |
|
Rev Time |
1.00 |
| Received By |
mgonzale |
Date |
2017-04-27 |
Time |
|
Sent To |
I |
|
| Notes |
| 2017-04-27 10:26:27 | **** IMPORTANT **** | | | | | | #1 DISCUSS WITH CITY OF WPB ENGINEERING DEPARTMENT | | | CUTTING AND CAPPING OF EXISTING WATERMAIN. | | | FORMAL SUBMITTAL SHALL BE MADE TO CITY OF WPB | | | ENGINEERING DEPARTMENT. | | | | | | #2 DISCUSS TIMELINE FOR WORK AND ENGINEERING ROW | | | PERMIT. | | | | | | #3 PROVIDE ENGINEER'S COST ESTIMATE FOR UTILITY WORK. | | | | | | MANUEL JULIAN GONZALEZ | | | ENGINEERING PROJECT COORDINATOR | | | PUBLIC WORKS DEPARTMENT | | | 401 CLEMATIS STREET, 4TH FLOOR | | | WEST PALM BEACH, FL 33401 | | | (MAILING ADDRESS: P.O. BOX 3366, ZIP 33402) | | | MAIN PHONE: (561) 822-1200 | | | DIRECT: (561) 494-1085 | | | FAX: (561) 494-1116 | | | EMAIL: [email protected] | | | HTTP://WWW.WPB.ORG/DEPARTMENTS/ENGINEERING-PUBLIC-WORKS | | | /FORMS,-PERMITS-APPLICATIONS | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
3 |
Status |
P |
Date |
2018-01-30 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2018-01-30 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2018-01-30 |
Time |
10:47 |
Sent To |
|
|
| Notes |
| 2018-01-30 11:16:23 | THIS PLAN WAS REVIEWED AND APPROVED BY PETER LEDUC, | | | FIRE MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. FAILURE TO FOLLOW THESE | | | PROVISO COMMENTS WILL RESULT IN A FAILED FIRE | | | INSPECTION. | | | | | | | | | 1) LIGHT-FRAME TRUSS-TYPE FLOOR AND ROOF SIGN IS | | | REQUIRED BY FLORIDA STATUTE. | | | | | | THE TYPE OF DESIGN YOU HAVE INDICATED IS INCLUDED AS | | | LIGHTWEIGHT FLOOR AND ROOF. | | | | | | 633.222?BUILDINGS WITH LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION; NOTICE REQUIREMENTS; ENFORCEMENT.? | | | (1)?THE OWNER OF ANY COMMERCIAL OR INDUSTRIAL | | | STRUCTURE, OR ANY MULTIUNIT RESIDENTIAL STRUCTURE OF | | | THREE UNITS OR MORE, THAT USES LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION SHALL MARK THE STRUCTURE WITH A SIGN OR | | | SYMBOL APPROVED BY THE STATE FIRE MARSHAL IN A MANNER | | | SUFFICIENT TO WARN PERSONS CONDUCTING FIRE CONTROL AND | | | OTHER EMERGENCY OPERATIONS OF THE EXISTENCE OF | | | LIGHT-FRAME TRUSS-TYPE CONSTRUCTION IN THE STRUCTURE. | | | | | | (2)?THE STATE FIRE MARSHAL SHALL ADOPT RULES NECESSARY | | | TO IMPLEMENT THE PROVISIONS OF THIS SECTION, INCLUDING, | | | BUT NOT LIMITED TO: | | | (A)?THE DIMENSIONS AND COLOR OF SUCH SIGN OR SYMBOL. | | | | | | (B)?THE TIME WITHIN WHICH COMMERCIAL, INDUSTRIAL, AND | | | MULTIUNIT RESIDENTIAL STRUCTURES THAT USE LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION SHALL BE MARKED AS REQUIRED BY | | | THIS SECTION. | | | | | | (C)?THE LOCATION ON EACH COMMERCIAL, INDUSTRIAL, AND | | | MULTIUNIT RESIDENTIAL STRUCTURE THAT USES LIGHT-FRAME | | | TRUSS-TYPE CONSTRUCTION WHERE SUCH SIGN OR SYMBOL MUST | | | BE POSTED. | | | | | | (3)?THE STATE FIRE MARSHAL, AND LOCAL FIRE OFFICIALS IN | | | ACCORDANCE WITH S. 633.118, SHALL ENFORCE THIS SECTION. | | | AN OWNER WHO FAILS TO COMPLY WITH THE REQUIREMENTS OF | | | THIS SECTION IS SUBJECT TO PENALTIES AS PROVIDED IN S. | | | 633.228. | | | | | | | | | 69A-60.0081 NOTICE REQUIRED FOR STRUCTURES WITH | | | LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | | (1) PURPOSE: THE PURPOSE OF THIS RULE IS TO REQUIRE THE | | | PLACEMENT OF AN IDENTIFYING SYMBOL ON STRUCTURES | | | CONSTRUCTED WITH A LIGHT-FRAME TRUSS COMPONENT IN A | | | MANNER SUFFICIENT TO WARN PERSONS CONDUCTING FIRE | | | CONTROL AND OTHER EMERGENCY OPERATIONS OF THE EXISTENCE | | | OF LIGHT-FRAME TRUSS-TYPE CONSTRUCTION IN THE | | | STRUCTURE. | | | (2) DEFINITIONS. | | | (A) ?LIGHT-FRAME TRUSS-TYPE CONSTRUCTION? MEANS A TYPE | | | OF CONSTRUCTION WHOSE PRIMARY STRUCTURAL ELEMENTS ARE | | | FORMED BY A SYSTEM OF REPETITIVE WOOD OR LIGHT GAUGE | | | STEEL FRAMING MEMBERS. | | | (B) ?APPROVED SYMBOL? MEANS A MALTESE CROSS MEASURING 8 | | | INCHES HORIZONTALLY AND 8 INCHES VERTICALLY, OF A | | | BRIGHT RED REFLECTIVE COLOR, DESIGNED IN ACCORDANCE | | | WITH FIGURE 1. | | | (3) ANY COMMERCIAL, INDUSTRIAL, OR MULTIUNIT | | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE, WHICH | | | USES HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH AN | | | APPROVED SYMBOL. TOWNHOUSES ARE NOT MULTIUNIT | | | RESIDENTIAL STRUCTURES AND THEREFORE NOT SUBJECT TO | | | THIS RULE. EACH APPROVED SYMBOL SHALL INCLUDE WITHIN | | | THE CENTER CIRCLE ONE OF THE FOLLOWING DESIGNATIONS: | | | (A) STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER ?R?. | | | (B) STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER ?F?. | | | (C) STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS ?RF.? | | | (4) THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 | | | INCHES TO THE LEFT OF THE MAIN ENTRY DOOR AND: | | | (A) BE PERMANENTLY ATTACHED TO THE FACE OF THE | | | STRUCTURE ON A CONTRASTING BACKGROUND; OR | | | (B) BE MOUNTED ON A CONTRASTING BASE MATERIAL WHICH IS | | | THEN PERMANENTLY ATTACHED TO THE FACE OF THE STRUCTURE. | | | (5) THE DISTANCE ABOVE THE GRADE, WALKING SURFACE OR | | | THE FINISHED FLOOR TO THE BOTTOM OF THE SYMBOL SHALL BE | | | NOT LESS THAN 4 FEET (48 IN.). | | | (6) THE DISTANCE ABOVE THE GRADE, WALKING SURFACE OR | | | THE FINISHED FLOOR TO THE TOP OF THE SYMBOL SHALL BE | | | NOT MORE THAN 6 FEET (72 IN.). | | | (7) IN SINGLE TENANT STRUCTURES WITH MULTIPLE MAIN | | | ENTRY DOORS, SUCH AS BIG BOX RETAIL STORES, DEPARTMENT | | | STORES AND GROCERY STORES, THE AUTHORITY HAVING | | | JURISDICTION IS AUTHORIZED TO REQUIRE THAT OTHER MAIN | | | ENTRY DOORS OF THE STRUCTURE BE MARKED WITH AN APPROVED | | | SYMBOL TO CARRY OUT THE PURPOSE IN SUBSECTION (1) | | | ABOVE. | | | (8) IN MULTIPLE TENANT STRUCTURES AND COVERED MALL | | | STRUCTURES WITH MULTIPLE MAIN ENTRY DOORS, THE | | | AUTHORITY HAVING JURISDICTION IS AUTHORIZED TO REQUIRE | | | THAT OTHER MAIN ENTRY DOORS OF THE STRUCTURE BE MARKED | | | WITH AN APPROVED SYMBOL TO CARRY OUT THE PURPOSE IN | | | SUBSECTION (1) ABOVE. | | | (9) IN MULTIPLE TENANT STRUCTURES AND COVERED MALLS | | | WITH MULTIPLE MAIN ENTRY DOORS, THE AUTHORITY HAVING | | | JURISDICTION IS AUTHORIZED TO REQUIRE THAT OTHER MAIN | | | ENTRY DOORS BE MARKED WITH AN APPROVED SYMBOL TO CARRY | | | OUT THE PURPOSE IN SUBSECTION (1) ABOVE. IN SUCH | | | STRUCTURES, APPROVED SYMBOLS SHALL BE MARKED ON ONE | | | SIDE OF THE STRUCTURE ONLY AND SPACED NOT CLOSER THAN | | | 100 FEET OR AT EACH END OF THE STRUCTURE WHEN SUCH | | | STRUCTURE IS LESS THAN 100 FEET IN LENGTH. | | | (10) THE OWNER OF EACH NEW STRUCTURE REQUIRED TO COMPLY | | | WITH THIS SECTION SHALL MARK THE STRUCTURE WITH THE | | | APPROVED SYMBOL PRIOR TO RECEIVING A CERTIFICATE OF | | | OCCUPANCY. | | | (11) THE OWNER OF EACH EXISTING STRUCTURE REQUIRED TO | | | COMPLY WITH THIS SECTION SHALL MARK THE STRUCTURE WITH | | | THE APPROVED SYMBOL WITHIN 90 DAYS OF THE EFFECTIVE | | | DATE OF THIS RULE. | | | (12) WHERE THE OWNER OF THE STRUCTURE AND THE AUTHORITY | | | HAVING JURISDICTION DISAGREE AS TO THE USE OF | | | LIGHT-FRAME TRUSS-TYPE CONSTRUCTION WITHIN THE | | | STRUCTURE, THE OWNER SHALL BE GRANTED NOT MORE THAN 45 | | | DAYS TO PROVIDE WRITTEN VERIFICATION FROM A LICENSED | | | ENGINEER OR LICENSED ARCHITECT; OTHERWISE, THE OWNER | | | SHALL COMPLY WITH THE RULE. | | | | | | PLEASE PROVIDE THE REQUIRED SIGNAGE. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
F |
Date |
2017-08-28 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-08-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-08-25 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2017-08-25 14:06:39 | 2ND REVIEW COMMENTS: | | | | | | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) IT IS UNCLEAR WHAT THE SCOPE OF WORK IS FOR THE | | | SUBMITTED PERMIT, FOUNDATION, SHELL OR ENTIRE BUILDING? | | | | | | COMPLIED; FULL LIFE SAFETY REVIEW, ENTIRE | | | BUILDING/SITE. | | | | | | | | | 2) SHEET A 0.01 - THERE ARE INCORRECT REFERNCES TO THE | | | CURRENT EDITIONS OF THE FIRE CODE INDICATED. | | | | | | NOT COMPLIED: THE CURRENT EDITION OF THE FLORIDA FIRE | | | PREVENTION CODE IS 2014, AS NOTED IN MY COMMENTS | | | PREVIOUSLY; 2015 WAS INSERTED AND IS INCORRECT. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL COMPLY WITH | | | NFPA 110, 2013 EDITION. | | | | | | PLEASE CORRECT. | | | | | | | | | | | | 3) SHEET A 0.02 - THE GYM ASSEMBLY OCCUPANCY | | | CALCULATION IS INDICATED 15/PERSON/SQ FT. OR 400. THERE | | | IS NO SEATING PLAN INDICATED AND 15 CAN NOT BE USED, | | | 7/PERSON/SQ FT SHALL BE USED. THIS RENDERS ALL YOUR | | | EGRESS CALCULATION INACCURATE. | | | | | | NOT COMPLIED. THIS AREA IS MORE THAN AN EXERCISE ROOM | | | | | | PER NFPA 101, CHAPTER 12, ASSEMBLY OCCUPANCIES AND | | | CHAPTER 7 MEANS OF EGRESS. | | | | | | TABLE 7.3.1.2 OCCUPANCT LOAD FACTOR, CONCENTRATED USE, | | | WITHOUT FIXED SEATING 7 NET IS TO BE USED. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 4) SHEET A 0.02 - NOTE # 7 INDICATES AN INCORRECT | | | REFERENCE TO NFPA 13. | | | | | | NOT COMPLIED: THE CURRENT EDITION OF NFPA 13, AS NOTED | | | IN MY COMMENTS IS 2010; 2016 WAS INSERTED AND IS | | | INCORRECT. | | | | | | PLEASE CORRECT IT TO 2010 AS NOTED ABOVE. | | | | | | | | | | | | 5) SHEET A 0.02 - NOTE # 9 INDICATES THAT THE GYM | | | OCCUPANCY LOAD BE REDUCED AS A REFLECTION OF THE SCHOOL | | | OCCUPANCY. THE CODE IS WRITTEN FOR THE POTENTIAL USE OF | | | THE SPACE, NOT JUST THE OCCUPANCY OF THE SCHOOL. THERE | | | MAY BE SPECIAL EVENTS OR OTHER ACTIVITES THAT MAY | | | SUBJECT THE SPACE TO THE HIGHEST POTENTIAL OCCUPANCY | | | LOAD. | | | | | | NOT COMPLIED. | | | | | | NFPA 101, CHAPTER & MEANS OF EGRESS. | | | | | | 7.3.1.2* OCCUPANT LOAD FACTOR. THE OCCUPANT LOAD IN ANY | | | BUILDING OR PORTION THEREOF SHALL BE NOT LESS THAN THE | | | NUMBER OF PERSONS DETERMINED BY DIVIDING THE FLOOR AREA | | | ASSIGNED TO THAT USE BY THE OCCUPANT LOAD FACTOR FOR | | | THAT USE AS SPECIFIED IN TABLE 7.3.1.2, FIGURE | | | 7.3.1.2(A), AND FIGURE 7.3.1.2(B). WHERE BOTH GROSS AND | | | NET AREA FIGURES ARE GIVEN FOR THE SAME OCCUPANCY, | | | CALCULATIONS SHALL BE MADE BY APPLYING THE GROSS AREA | | | FIGURE TO THE GROSS AREA OF THE PORTION OF THE BUILDING | | | DEVOTED TO THE USE FOR WHICH THE GROSS AREA FIGURE IS | | | SPECIFIED AND BY APPLYING THE NET AREA FIGURE TO THE | | | NET AREA OF THE PORTION OF THE BUILDING DEVOTED TO THE | | | USE FOR WHICH THE NET AREA FIGURE IS SPECIFIED. | | | | | | | | | PLEASE REVIEW, CORRECT OR REMOVE THE COMMENT. | | | | | | | | | | | | 6) SHEET A 2.01 - THERE ARE LIGHWIEGHT TRUSS DESIGNED | | | FOR THIS PROJECT. | | | | | | NOT COMPLIED; A LIGHTWEIGHT TRUSS SIGN IS REQUIRED. | | | PLEASE PROVIDE AN APPLICABLE NOTE OF COMPLIANCE. | | | | | | PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR | | | STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | | ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT | | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES | | | HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A | | | MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND | | | 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR. | | | THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO | | | THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | PLEASE PROVIDE FOR THE APPLICABLE SIGNAGE. | | | | | | | | | | | | | | | 7) SHEET A 1.00 - NOTE # 1 INDICATES "DEMOLISH EXISTING | | | ALUMINUM STAIR AND STRUCTURE". | | | | | | NOT COMPLIED. NO REVISION SHEET FOUND, NO REVISION | | | DRAWINGS FOUND ON ANY SHEET. | | | | | | THE EXISTING STAIR AND STRUCTURE IS A REQUIRED EXIT OF | | | THE EXISTING SCHOOL. | | | | | | PLEASE PROVIDE A LIFE SAFETY PLAN FOR THE EXISTING | | | SCHOOL AND INDICATE IN DETAILS HOW THE EXITING OF THE | | | EXISTING SCHOOL WILL BE MAINTAINED DURING ALL | | | CONSTRUCTION ACTIVITY UNTIL COMPLETION. | | | | | | | | | | | | | | | 8) SHEET 0.02 - IT IS NOT CLEAR THAT ALL EXITS LEAD TO | | | A PUBLIC WAY. | | | | | | NOT COMPLIED. NO REVISION SHEET FOUND, NO REVISION | | | DRAWINGS FOUND ON ANY SHEET. | | | | | | | | | PLEASE PROVIDE AN ENTIRE SITE PLAN INDICATING PASSAGE | | | TO A PUBLIC WAY OR AREA OF SAFETY. | | | | | | | | | | | | 9) ALL SHEETS - IT APPEARS THAT MANY OF THE INTERIOR | | | FLOOR PLANS WERE NOT INCLUDED, SO AN ACCURATE REVIEW OF | | | THE ENTIRE PROPOSED SCHOOL BUILDING COULD NOT BE | | | COMPLETED. | | | | | | COMPLIED | | | | | | | | | | | | 10) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 11) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
F |
Date |
2017-05-03 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-03 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-02 |
Time |
15:26 |
Sent To |
|
|
| Notes |
| 2017-05-03 12:31:34 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | | | | | | | 1) IT IS UNCLEAR WHAT THE SCOPE OF WORK IS FOR THE | | | SUBMITTED PERMIT, FOUNDATION, SHELL OR ENTIRE BUILDING? | | | | | | PLEASE CLARIFY. | | | | | | SOME OF THE COMMENTS MAY NOT APPLY TO A FOUNDATION AND | | | SHELL PERMIT. | | | | | | | | | 2) SHEET A 0.01 - THERE ARE INCORRECT REFERNCES TO THE | | | CURRENT EDITIONS OF THE FIRE CODE INDICATED. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | FIRE EXTINGUISHERS SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 10, 2010 EDITION. | | | ELECTRIC WORK SHALL COMPLY WITH NFPA 70, 2011 EDITION. | | | EMERGENCY AND STANDBY POWER SYSTEMS SHALL COMPLY WITH | | | NFPA 110, 2013 EDITION. | | | | | | PLEASE CORRECT. | | | | | | | | | | | | 3) SHEET A 0.02 - THE GYM ASSEMBLE OCCUPANCY | | | CALCULATION IS INDICATED 15/PERSON/SQ FT. OR 400. THERE | | | IS NO SEATING PLAN INDICATED AND 15 CAN NOT BE USED, | | | 7/PERSON/SQ FT SHALL BE USED. THIS RENDERS ALL YOUR | | | EGRESS CLAUCULATION INACCURATE. | | | | | | PER NFPA 101, CHAPTER 12, ASSEMBLY OCCUPANCIES AND | | | CHAPTER 7 MEANS OF EGRESS. | | | | | | TABLE 7.3.1.2 OCCUPANCT LOAD FACTOR, CONCENTRATED USE, | | | WITHOUT FIXED SEATING 7 NET IS TO BE USED. | | | | | | PLEASE REVIEW AND CORRECT. | | | | | | | | | | | | 4) SHEET A 0.02 - NOTE # 7 INDICATES AN INCORRECT | | | REFERENCE TO NFPA 13. | | | | | | PLEASE CORRECT IT TO 2010 AS NOTED ABOVE. | | | | | | | | | | | | 5) SHEET A 0.02 - NOTE # 9 INDICATES THAT THE GYM | | | OCCUPANCY LOAD BE REDUCED AS A REFLECTION OF THE SCHOOL | | | OCCUPANCY. THE CODE IS WRITTEN FOR THE POTENTIAL USE OF | | | THE SPACE, NOT JUST THE OCCUPANCY OF THE SCHOOL. THERE | | | MAY BE SPECIAL EVENTS OR OTHER ACTIVITES THAT MAY | | | SUBJECT THE SPACE TO THE HIGHEST POTENTIAL OCCUPANCY | | | LOAD. | | | | | | NFPA 101, CHPATER & MEANS OF EGRESS. | | | | | | 7.3.1.2* OCCUPANT LOAD FACTOR. THE OCCUPANT LOAD IN ANY | | | BUILDING OR PORTION THEREOF SHALL BE NOT LESS THAN THE | | | NUMBER OF PERSONS DETERMINED BY DIVIDING THE FLOOR AREA | | | ASSIGNED TO THAT USE BY THE OCCUPANT LOAD FACTOR FOR | | | THAT USE AS SPECIFIED IN TABLE 7.3.1.2, FIGURE | | | 7.3.1.2(A), AND FIGURE 7.3.1.2(B). WHERE BOTH GROSS AND | | | NET AREA FIGURES ARE GIVEN FOR THE SAME OCCUPANCY, | | | CALCULATIONS SHALL BE MADE BY APPLYING THE GROSS AREA | | | FIGURE TO THE GROSS AREA OF THE PORTION OF THE BUILDING | | | DEVOTED TO THE USE FOR WHICH THE GROSS AREA FIGURE IS | | | SPECIFIED AND BY APPLYING THE NET AREA FIGURE TO THE | | | NET AREA OF THE PORTION OF THE BUILDING DEVOTED TO THE | | | USE FOR WHICH THE NET AREA FIGURE IS SPECIFIED. | | | | | | | | | PLEASE REVIEW, CORRECT OR REMOVE THE COMMENT. | | | | | | | | | | | | 6) SHEET A 2.01 - THERE ARE LIGHWIEGHT TRUSS DESIGNED | | | FOR THIS PROJECT. | | | | | | PER FLORIDA 69A-60.0081; NOTICE SIGNAGE IS REQUIRED FOR | | | STRUCTURES WITH LIGHT-FRAME TRUSS-TYPE CONSTRUCTION. | | | ANY COMMERCIAL, INDUSTRIAL, OR ANY MULTIUNIT | | | RESIDENTIAL STRUCTURE OF THREE UNITS OR MORE WHICH USES | | | HORIZONTAL OR VERTICAL LIGHT-FRAME TRUSS-TYPE | | | CONSTRUCTION IN ANY PORTION SHALL BE MARKED WITH A | | | MALTESE CROSS SIGN MEASURING 8 INCHES HORIZONTALLY AND | | | 8 INCHES VERTICALLY, OF A BRIGHT RED REFLECTIVE COLOR. | | | THE APPROVED SYMBOL SHALL BE PLACED WITHIN 24 INCHES TO | | | THE LEFT OF THE MAIN ENTRY DOOR. | | | 1. STRUCTURES WITH LIGHT-FRAME TRUSS ROOFS SHALL BE | | | MARKED WITH THE LETTER "R". | | | 2. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR SYSTEMS | | | SHALL BE MARKED WITH THE LETTER "F". | | | 3. STRUCTURES WITH LIGHT-FRAME TRUSS FLOOR AND ROOF | | | SYSTEMS SHALL BE MARKED WITH THE LETTERS "R/F". | | | | | | PLEASE PROVIDE FOR THE APPLICABLE SIGNAGE. | | | | | | | | | | | | 7) SHEET A 1.00 - NOTE # 1 INDICATES "DEMOLISH EXISTING | | | ALUMINUM STAIR AND STRUCTURE". | | | | | | THE EXISTING STAIR AND STRUCTURE IS A REQUIRED EXIT OF | | | THE EXISTING SCHOOL. | | | | | | PLEASE PROVIDE A LIFE SAFETY PLAN FOR THE EXISTING | | | SCHOOL AND INDICATE IN DETAILS HOW THE EXITING OF THE | | | EXISTING SCHOOL WILL BE MAINTAINED DURING ALL | | | CONSTRUCTION ACTIVITY UNTIL COMPLETION. | | | | | | | | | | | | | | | 8) SHEET 0.02 - IT IS NOT CLEAR THAT ALL EXITS LEAD TO | | | A PUBLIC WAY. | | | | | | PLEASE PROVIDE AN ENTIRE SITE PLAN INDICATING PASSAGE | | | TO A PUBLIC WAY OR AREA OF SAFETY. | | | | | | | | | | | | 9) ALL SHEETS - IT APPEARS THAT MANY OF THE INTERIOR | | | FLOOR PLANS WERE NOT INCLUDED, SO AN ACCURATE REVIEW OF | | | THE ENTIRE PROPOSED SCHOOL BUILDING COULD NOT BE | | | COMPLETED. | | | | | | PLEASE REVIEW AND SEE # 1 ABOVE AND PROVIDE CLEAR SCOPE | | | OF WORK. | | | | | | | | | | | | 10) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | | ABOVE. | | | | | | | | | | | | 11) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | | RE-SUBMITTAL OF THE ABOVE. | | | | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
5 |
Status |
N |
Date |
2018-03-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-03-22 |
Time |
11:17 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-03-15 |
Time |
14:20 |
Sent To |
|
|
| Notes |
| 2018-03-16 14:20:54 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2018-03-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-03-15 |
Time |
15:42 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-02-28 |
Time |
16:39 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-28 |
Time |
06:50 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-01-26 |
Time |
15:49 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-09-26 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-26 |
Time |
16:47 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-08-21 |
Time |
15:43 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-11 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-03 |
Time |
08:05 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-18 |
Time |
13:24 |
Sent To |
|
|
| Notes |
| 2017-05-11 08:06:22 | TOOK OFF BOARD (CUSTOMER AWARE; CHECKED OUT ONE SET OF | | | PLANS ON 5/3) | | 2017-04-19 13:31:10 | C19 |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2018-02-12 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2018-02-12 |
Time |
08:13 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2018-02-12 |
Time |
08:13 |
Sent To |
|
|
| Notes |
| 2018-02-12 08:13:52 | SEE IMPACT FEE UNDER REVISION 17100798: | | | MU 2017-30025, $3,148.12 | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-04-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-04-27 |
Time |
07:16 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-27 |
Time |
07:16 |
Sent To |
|
|
| Notes |
| 2017-04-27 07:17:13 | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY REQUIRED | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT FEES HAVE BEEN PAID IS TO BE PROVIDED | | | | | | 561-233-5025 FOR MORE INFORMATION | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
5 |
Status |
P |
Date |
2018-03-19 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-03-19 |
Time |
08:42 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-16 |
Time |
17:09 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
F |
Date |
2018-03-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-03-12 |
Time |
10:03 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-03-09 |
Time |
16:35 |
Sent To |
|
|
| Notes |
| 2018-03-12 11:06:29 | 4TH REVIEW FBC-2014 MECHANICAL | | | PERMIT #17040807 | | | 3/12/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) SHEET M2.1.1: AS PREVIOUSLY NOTED IN THE 3RD REVIEW, | | | THE SHOP (FAB LAB) SHALL HAVE AN INDEPENDENT EXHAUST | | | SYSTEM AND SHALL NOT BE CONNECTED TO THE TOILET ROOM | | | EXHAUST DUCT. | | | | | | 2) M2.1.1: RECIRCULATION OF AIR FROM THE FAB LAB IS | | | LIMITED TO 10% PER FOOTNOTE G TABLE 403.3. THE PLAN | | | DOES NOT CLEARLY SHOW IF AIR IS BEING RETURNED VIA THE | | | 30X16" DUCT- PLEASE CLARIFY. | | | | | | 3) M2.2.1: FIRE DAMPERS ARE MISSING WHERE THE 28X16 AND | | | 22X12 DUCTS ARE PENETRATING THE FIRE-RATED SHAFT. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2018-02-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2018-02-06 |
Time |
12:48 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2018-02-06 |
Time |
10:52 |
Sent To |
|
|
| Notes |
| 2018-02-06 13:17:19 | 3RD REVIEW FBC-2014 MECHANICAL, ENERGY CONSERVATION | | | CODES | | | PERMIT #17040807 | | | 2/6/18 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) THE SUBMITTED ENERGYGAUGE COMPLIANCE FORM, AND THE | | | AC LOAD CALCULATIONS INDICATE AC SYSTEMS EXCEEDING 15 | | | TONS WHICH REQUIRES THE ENGINEER OF RECORD TO PROVIDE | | | HIS SIGNATURE AND SEAL ON THE DOCUMENTS- SECTION | | | C103.1.1.1.2 FLORIDA ENERGY CONSERVATION CODE. | | | | | | 2) THE AIRSOCK DUCKWORK SHALL BE CONSTRUCTED WITH CLASS | | | 0 OR CLASS 1 MATERIAL AND SHALL COMPLY WITH UL 181- | | | SECTION 603.5. PLEASE PROVIDE A PRODUCT DATA SHEET WITH | | | SHOP DRAWING APPROVAL STAMP BY THE EOR. | | | | | | 3) ACCORDING TO THE RESPONSE NARRATIVE BY KAMM | | | ENGINEERING THE FAB LAB IS ACTUALLY A METAL/WOOD SHOP. | | | PLEASE SEE SECTIONS 510.2.1, 510.4, AND 511 AND PROVIDE | | | AN INDEPENDENT EXHAUST SYSTEM FOR THE ROOM (NOT | | | CONJLOINED WITH THE RESTROOM), AND A DUCT COLLECTION | | | SYSTEM FOR THE SHOP EQUIPMENT. | | | | | | 4) ACCORDING TO THE RESPONSE NARRATIVE BY KAMM | | | ENGINEERING, THE WIND LOAD ENGINEERING IS BE PROVIDED | | | BY OTHERS AS A DEFERRED SUBMITTAL: | | | | | | 1) DEFERRED SUBMITTAL: 107.3.4.2 DEFERRED SUBMITTALS. | | | FOR THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS | | | ARE DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE | | | NOT SUBMITTED AT THE TIME OF THE APPLICATION AND THAT | | | ARE TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A | | | SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL | | | HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE | | | REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE | | | SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION | | | DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL. | | | DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE | | | SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN | | | RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD | | | THEM TO THE BUILDING OFFICIAL WITH A NOTATION | | | INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE | | | BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO | | | THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL | | | ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED | | | SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING | | | OFFICIAL. | | | 2) DEFERRED SUBMITTAL. FBC 107.3.4.1 PRODUCT APPROVALS. | | | THOSE PRODUCTS WHICH ARE REGULATED BY THE DCA RULE | | | 9N-03 SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | | JURISDICTIONAL APPROVAL. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. ADDITIONALLY, PLEASE INSERT | | | CORRECTED PLAN SHEETS INTO THE SETS, REMOVE THE | | | PREVIOUSLY REVIEWED SHEETS AND MARK VOID ON THEM, AND | | | KEEP THEM WITH THE SUBMITTALS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-09-06 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-09-06 |
Time |
14:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-09-06 |
Time |
14:33 |
Sent To |
|
|
| Notes |
| 2017-09-06 15:14:03 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17040807 | | | 9/6/17 | | | | | | PLAN REVIEW RESULTS: DENIED. | | | | | | 1) 2ND REQUEST FOR AC COOLING AND HEATING CALCULATIONS, | | | AND ENERGY CALCULATIONS- PLEASE COMPLY. | | | | | | 2) SHEETS M2.1.1 & M2.2.1: THE AC LAYOUT PLANS APPEAR | | | INCOMPLETE. A) INDICATE WHAT TYPE AND SIZE OF LOW | | | PRESSURE DUCTWORK IS TO BE INSTALLED AT THE OUTLETS OF | | | THE VAV BOXES. B) LABEL THE DIFFUSER LOCATIONS IN THE | | | LOW PRESSURE DUCTWORK AND INDICATE THE CFMS AT EACH. | | | | | | 3) M2.1.1, M2.2.1, & M2.2.2: PROVIDE DUCT SMOKE | | | DETECTORS IN THE RETURN AIR SYSTEMS OF THE NEW RTU'S- | | | SECTION 606.2.1. | | | | | | 4) M2.1.1 & M2.2.1: THE CORRIDORS CANNOT BE USED TO | | | CONVEY RETURN AIR VIA THE TRANSFERS FROM THE CLASSROOMS | | | AND OTHER ROOMS TO THE RTU'S- SECTION 601.2. | | | | | | 5) M2.1.1 & M6.1: AN EXHAUST VENTILATION SYSTEM IS | | | REQUIRED FOR THE LAB IN COMPLIANCE WITH TABLE 403.3 | | | FBC-14 MECHANICAL, AND TABLE 6-4 ASHRAE 62.1-2010. THE | | | EXHAUST RATE IS CALCULATED AT A RATE OF 1.0 CFMS PER | | | SQ. FT. REVISE THE PLANS AND CALCULATIONS TO SHOW THE | | | REQUIRED SYSTEM, AND REVISE THE O/A TABLE TO INCLUDE | | | THE FRESH AIR RATE FOR THE ROOM. PLEASE NOTE THAT | | | | | | RECIRCULATION OF AIR FROM THE SPACE IS PROHIBITED PER | | | FOOTNOTE G. | | | | | | 6) THE RTU EQUIPMENT SCHEDULE INDICATES THAT BOTH RTU-2 | | | & RTU-4 ARE EQUIPPED WITH ERV'S, HOWEVER NO EXHAUST | | | SYSTEM IS CONNECTING TO RTU-4. PLEASE CLARIFY. | | | | | | 7) M6.1: THE VENTILATION RATE FOR THE CLASSROOMS IS | | | CALCULATED AT 0.12 CFMS PER SQ. FT. PLEASE CORRECT THE | | | O/A SCHEDULE. | | | | | | 8) PROVIDE COMPLETE STRUCTURAL ENGINEERING AND WIND | | | DESIGN CRITERIA FOR INSTALLATION OF THE RTU'S- SECTION | | | 301.15. | | | | | | 9) PROVIDE A CONDENSATE DISPOSAL PLAN FOR THE RTU'S- | | | SECTION 307. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-04-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-26 |
Time |
08:18 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-04-26 |
Time |
07:11 |
Sent To |
|
|
| Notes |
| 2017-04-26 08:22:01 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17040807 | | | 4/26/17 | | | | | | 1) PROVIDE COMPLETE SETS OF MECHANICAL PLANS, | | | SPECIFICATIONS, AND AC AND ENERGY CALCULATIONS. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
4 |
Status |
P |
Date |
2018-03-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-03-13 |
Time |
08:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-03-13 |
Time |
08:17 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
3 |
Status |
F |
Date |
2018-02-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2018-02-12 |
Time |
07:02 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2018-02-12 |
Time |
07:02 |
Sent To |
|
|
| Notes |
| 2018-02-12 07:13:03 | 3RD REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENTS NOT COMPLIED | | | | | | 3RD REQUEST 2. PLEASE PROVIDE A FIXTURE COUNT | | | BREAKDOWN. PER WPB AMEND TO FBC 107.3.5.1.3 | | | | | | 2ND REQUEST 1.THE CIRCUIT VENT CONNECTION SHALL BE | | | LOCATED BETWEEN THE TWO MOST UPSTREAM WATER CLOSET | | | DRAINS. THE VENT SHALL CONNECT TO THE HORIZONTAL BRANCH | | | AND SHALL BE INSTALLED IN ACCORDANCE WITH SECTION 905. | | | THE CIRCUIT VENT PIPE SHALL NOT RECEIVE THE DISCHARGE | | | OF ANY SOIL OR WASTE. PER FBC PL 914.2 | | | | | | 2ND REQUEST 4. CIVIL SHT. #7 OF 8 SHOWS A GAS MAIN | | | RUNNING UNDER PROPOSED BUILDING GAS LINES SHALL NOT RUN | | | UNDER BUILDING WILL NEED TO BE RELOCATED.PER FBC FG | | | 404.14 | | | | | | 2ND REQUEST 5. THE CIVIL SHT #7 OF 8 THE CONFIGURATION | | | OF GREASE INTERCEPTOR DOES NOT MATCH EXISTING | | | INSTALLATION UNDER PERMIT 16041215. PLEASE CLARIFY. PER | | | WPB AMEND TO FBC 107.2.1 | | | | | | 2ND REQUEST 6. PROVIDE DETAILS FOR ACCESSIBILITY IN | | | BATHROOMS, DRINKING FOUNTAIN AND CLASSROOM SINKS. PER | | | FBC ACC CHAPTER 6 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER | | | CITY OF WEST PALM BEACH | | | 561-805-6711 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
F |
Date |
2017-09-13 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-09-13 |
Time |
13:45 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-09-13 |
Time |
11:07 |
Sent To |
|
|
| Notes |
| 2017-09-13 13:51:17 | 1ST REVIEW: FBC 2014 5TH EDITION | | | | | | PLUMBING COMMENTS: PREVIOUS COMMENT NOT COMPLIED | | | | | | 2. PLEASE PROVIDE A FIXTURE COUNT BREAKDOWN. PER WPB | | | AMEND TO FBC 107.3.5.1.3 | | | | | | NEW COMMENT: | | | | | | 1.THE CIRCUIT VENT CONNECTION SHALL BE LOCATED BETWEEN | | | THE TWO MOST UPSTREAM WATER CLOSET DRAINS. THE VENT | | | SHALL CONNECT TO THE HORIZONTAL BRANCH AND SHALL BE | | | INSTALLED IN ACCORDANCE WITH SECTION 905. THE CIRCUIT | | | VENT PIPE SHALL NOT RECEIVE THE DISCHARGE OF ANY SOIL | | | OR WASTE. PER FBC PL 914.2 | | | | | | 2. PLEASE PROVIDE SQFT DRAINED BY ROOF DRAINS. PER WPB | | | AMEND TO FBC 107.2.1 | | | | | | 3. PLEASE EXPAND SANITARY RISER IT IS DIFFICULT TO READ | | | AND WHEN IT IS SCANNED IN FOR OUR RECORDS IT WILL BE | | | EVEN HARDER TO READ. WPB AMEND TO FBC 107.2.1.4 | | | | | | 4. CIVIL SHT. #7 OF 8 SHOWS A GAS MAIN RUNNING UNDER | | | PROPOSED BUILDING GAS LINES SHALL NOT RUN UNDER | | | BUILDING WILL NEED TO BE RELOCATED.PER FBC FG 404.14 | | | | | | 5. THE CIVIL SHT #7 OF 8 THE CONFIGURATION OF GREASE | | | INTERCEPTOR DOES NOT MATCH EXISTING INSTALLATION UNDER | | | PERMIT 16041215. PLEASE CLARIFY. PER WPB AMEND TO FBC | | | 107.2.1 | | | | | | 6. PROVIDE DETAILS FOR ACCESSIBILITY IN BATHROOMS, | | | DRINKING FOUNTAIN AND CLASSROOM SINKS. PER FBC ACC | | | CHAPTER 6 | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | | THE PREVIOUSLY REVIEWED SHEETS. | | | | | | | | | | | | | | | | | | | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-05-02 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-02 |
Time |
09:08 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-01 |
Time |
15:31 |
Sent To |
|
|
| Notes |
| 2017-05-02 09:09:51 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PLEASE PROVIDE FULL SET OF PLUMBING DRAWINGS. PER | | | WPB AMEND TO FBC 107.3.5.1.3 | | | | | | 2. PLEASE PROVIDE A FIXTURE COUNT BREAKDOWN. PER WPB | | | AMEND TO FBC 107.3.5.1.3 | | | | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
R |
ROOF PLAN REVIEW |
| Rev No |
1 |
Status |
N |
Date |
2017-09-22 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-22 |
Time |
08:46 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-22 |
Time |
08:46 |
Sent To |
|
|
| Notes |
| 2017-09-22 09:05:33 | PRIOR TO INSTALLATION, ROOF PRODUCT APPROVALS, REVIEWED | | | BY DESIGNER OF RECORD, TO BE SUBMITTED WITH ENGINEERING | | | FOR ENHANCED FASTENING, IF APPLICABLE. | | | | | | |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
2 |
Status |
P |
Date |
2017-09-20 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-09-20 |
Time |
09:56 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-09-19 |
Time |
15:11 |
Sent To |
|
|
| Notes |
| 2017-09-19 15:12:44 | SPECIAL INSPECTOR AGREEMENT, PORTIONS APPROVED: | | | TIERRA SOUTH FLORIDA | | | FRANCOIS THOMAS, PE 56381, SI 7021399 | | | PEDRO ROSA, BN3764 | | | ANDREW MORGAN, PE 57171 (SEOR) | | | | | | ***PROVISO*** | | | A RESUME WAS SUBMITTED FOR ENRIQUE BURBANO BUT HE HAS | | | NOT SIGNED THE AGREEMENT AS OF 9/19/17. PROVIDE SI | | | AGREEMENT PAGE 3 OF 4, SIGNED BY FRANCOIS THOMAS, PE,SI | | | AND ENRIQUE BURBANO, BN4650 | | | | | | ORIGINALS SENT TO RECORDS ON 9/20/17 UNDER PERMIT | | | NUMBERS 17040807, 17060234 |
|
|
| Review Stop |
THRESHOLD |
THRESHOLD INSPECTOR DOCUMENTS |
| Rev No |
1 |
Status |
F |
Date |
2017-04-27 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-04-27 |
Time |
07:31 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-27 |
Time |
07:31 |
Sent To |
|
|
| Notes |
| 2017-04-27 07:31:45 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | THRESHOLD BUILDING / FL S. S. 553.71(7) "THRESHOLD | | | BUILDING" MEANING ANY BUILDING WHICH IS GREATER THAN | | | (3) STORIES OR 50 FT. IN HEIGHT, OR WHICH HAS AN | | | ASSEMBLY OCCUPANCY CLASSIFICATION AS DEFINED IN THE | | | FLORIDA BUILDING CODE WHICH EXCEEDS 5,000 SQ. FT. IN | | | AREA AND AN OCCUPANT CONTENT OF GREATER THAN 500 | | | PERSONS. | | | | | | SEE PAGES A0.02, A0.03 - 8,932 ASSEMBLY (A3 & A5), | | | OCCUPANT LOAD 538. | | | | | | A) 109.3.6.1 THRESHOLD INSPECTION PLAN. THE ENFORCING | | | AGENCY SHALL REQUIRE A (WRITTEN/ TYPED) SPECIAL | | | INSPECTOR TO PERFORM STRUCTURAL INSPECTIONS ON A | | | THRESHOLD BUILDING PURSUANT TO A STRUCTURAL INSPECTION | | | PLAN PREPARED BY THE ENGINEER OF RECORD. THE STRUCTURAL | | | INSPECTION PLAN MUST BE SUBMITTED TO THE ENFORCING | | | AGENCY PRIOR TO THE ISSUANCE OF A BUILDING PERMIT FOR | | | THE CONSTRUCTION OF A THRESHOLD BUILDING. THE PURPOSE | | | OF THE STRUCTURAL INSPECTION PLAN IS TO PROVIDE | | | SPECIFIC INSPECTION PROCEDURES AND SCHEDULES SO THAT | | | THE BUILDING CAN BE ADEQUATELY INSPECTED FOR COMPLIANCE | | | WITH THE PERMITTED DOCUMENTS. | | | | | | B) THRESHOLD INSPECTOR: WPB AMENDMENT 109.3.6.2 W.P.B. | | | CONSTRUCTION SERVICES DEPARTMENT REQUEST FOR THRESHOLD | | | BUILDINGS A SPECIAL INSPECTOR AS REQUIRED BY FL S S | | | 553.79(5) FLORIDA STATUTES TO THE MINIMUM INSPECTIONS | | | REQUIRED BY THIS CODE. THE THRESHOLD INSPECTION FORMS | | | ARE REQUIRED TO BE FILED OUT BY ALL PARTIES WITH | | | INTEREST, NOTARIZED AND RETURNED TO THIS OFFICE, AND | | | REVIEWED AND APPROVED BEFORE PERMIT ISSUANCE WILL TAKE | | | PLACE. CONTACT KEN CONRAD MANAGER OF THE SPECIAL | | | INSPECTOR PROGRAM AT (561)805-6666 FOR FURTHER | | | INFORMATION BEFORE THE PERMIT MAY BE ISSUED. | | | | | | C) THRESHOLD BLDG., REQUIRED STATEMENT W.P.B. AMENDMENT | | | 110.3.7.4.4, FS553.79(7)(D): ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT?S OR ENGINEER?S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE | | | FIRESAFETY STANDARDS AS DETERMINED BY THE LOCAL | | | AUTHORITY IN ACCORDANCE WITH THIS CHAPTER AND CHAPTER | | | 633. | | | | | | W.P.B. AMENDMENT 110.3.7.4.4 ALL PLANS FOR THE BUILDING | | | WHICH ARE REQUIRED TO BE SIGNED AND SEALED BY THE | | | ARCHITECT OR ENGINEER OF RECORD CONTAIN A STATEMENT | | | THAT, TO THE BEST OF THE ARCHITECT'S OR ENGINEER'S | | | KNOWLEDGE, THE PLANS AND SPECIFICATIONS COMPLY WITH THE | | | APPLICABLE FIRE-SAFETY STANDARDS AS DETERMINED BY THE | | | LOCAL AUTHORITY IN ACCORDANCE WITH THIS SECTION AND 633 | | | FLORIDA STATUTE. | | | | | | D) FOR THE SPECIAL INSPECTOR PLEASE PROVIDE A RESUME' | | | OF INSPECTION EXPERIENCE ON PREVIOUS PROJECT. THE | | | RESUME' MUST BE ACCOMPANIED BY ALL CERTIFICATES AS | | | SPECIFIED HEREIN. THE BUILDING OFFICIAL OR HIS DESIGNEE | | | WILL REVIEW THE RESUME'. AFTER THE RESUME' IS REVIEWED, | | | AN INTERVIEW WILL BE SCHEDULED. UNDER NO CIRCUMSTANCES | | | WILL AN INSPECTOR BE INTERVIEWED FOR WORK WITHOUT FIRST | | | MEETING THE ABOVE CRITERIA. | | | | | | E) THE CONTRACTOR WILL PRODUCE A JOB SUMMARY OR HISTORY | | | FOR THIS TYPE OF CONSTRUCTION. | | | | | | F) NOTE FOR PAPER PLANS 3 SETS OF DOCUMENTS ARE | | | REQUIRED. FOR DIGITAL PLANS, AFTER PERMIT ISSUANCE, | | | PLEASE E-MAIL THE PERMIT LIBRARIAN OF THE PERMIT BEING | | | ISSUED, THE PERMIT LIBRARIAN WILL THEN E-MAIL YOU THE | | | APPROVED AND BATCH STAMPED PLANS SO YOU MAY PRINT YOUR | | | PLANS, TWO SETS OF PLANS WILL NEED TO BE PRINTED IN | | | COLOR, (1) FOR THE THRESHOLD INSPECTOR, THE OTHER FOR | | | THE MEP INSPECTORS OTHER PLANS YOU WISH TO PRINT MAYBE | | | IN BLACK & WHITE. | | | | | | 2010 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING | | | CODE, CHAPTER 1, ADMINISTRATION, 110.3.7 THRESHOLD | | | BUILDINGS, GUIDELINES AND POLICIES FOR PROJECTS | | | CONCERNING SPECIAL INSPECTORS. | | | | | | G) 110.3.7.4.3 ALL SHORING AND RESHORING PROCEDURES, | | | PLANS AND DETAILS SHALL BE SUBMITTED TO THE ENFORCEMENT | | | AGENCY FOR RECORDKEEPING. EACH SHORING AND RESHORING | | | INSTALLATION SHALL BE SUPERVISED, INSPECTED AND | | | CERTIFIED TO BE IN COMPLIANCE WITH THE SHORING | | | DOCUMENTS BY THE CONTRACTOR. | | | | | | H) PLEASE CALL THE CITY OF WEST PALM BEACH?S AUTOMATED | | | TELEPHONE INSPECTIONS LINE (561) 805-6700) FOR ALL | | | BUILDING INSPECTIONS FOR AUDITING OF JOBSITE | | | INSPECTIONS WITHOUT THIS THE PERMIT EXPIRES IN 6 | | | MONTHS, ABANDONMENT OF JOB, NO INSPECTION ACTIVITY. | | | | | | I) 109.3.6 THRESHOLD BUILDINGS, OPERATING GUIDELINES | | | FOR THRESHOLD INSPECTORS #26. ASSURE THAT THE DESIGNER | | | HAS REQUIRED ON THE PLANS OR SPECIFICATIONS ONE | | | MATERIAL, APPROVED FOR FIRE STOPPING PENETRATIONS, FOR | | | WALLS AND CEILINGS. | | | | | | SI AGREEMENT AND POLICY SENT VIA EMAIL TO | | | [email protected] ON 4/27/17. | | | | | | A RESIDENT INSPECTOR AGREEMENT WAS SUBMITTED. THIS DOES | | | NOT MEET THE STATUTORY REQUIREMENTS OF FS 553.79. | | | | | | ANDREW MORGAN, PE SIGNED THE RESIDENT INSPECTOR | | | AGEEMENT; THE SPECIAL INSPECTOR AGREEMENT IS REQUIRED | | | AND THE ENGINEER'S SIGNATURE AND SEAL IS REQUIRED, | | | FAC61G15-35.004. | | | | | | RICHARD AHRENS SIGNED AS GENERAL CONTRACTOR BUT THE | | | NOTARARIAL CERTIFICATE HAS ANDREW MORGAN'S NAME AS | | | SIGNING. | | | | | | NONE OF THE NOTARIAL CERTIFICATES INDICATE WHETHER ID | | | WAS PRODUCED OR IF THE PERSON IS PERSONALLY KNOWN TO | | | THE NOTARY. | | | | | | UNKNOWN PERSON SIGNED AS OWNER. THE NOTARARIAL | | | CERTIFICATE DOES NOT INCLUDE A NAME. | | | | | | THE AFFIDAVIT CERTIFICATE OF CODE COMPLIANCE IS SIGNED | | | BY THE CONTRACTOR AND ENGINEER, BUT THE CONSTRUCTION | | | HAS NOT YET TAKEN PLACE. THIS DOCUMENT CERTIFIES THAT | | | THE CONTRACTOR INSTALLED AND ENGINEER INSPECTED IN | | | ACCORDANCE WITH APPROVED PLANS, SPECIFICATIONS AND | | | CODES. | | | | | | WILL ANDREW MORGAN, PE BE THE ONLY INDIVIDUAL | | | PERFORMING INSPECTIONS? A BACKUP INSPECTOR IS | | | RECOMMENDED IN THE EVENT THAT MR. MORGAN IS | | | UNAVAILABLE. ONLY INDIVIDUALS WHO HAVE SIGNED THE | | | AGREEMENT AND HAVE BEEN APPROVED IN ADVANCE CAN PERFORM | | | INSPECTIONS ON BEHALF OF THE SI. | | | | | | FS 553.79(5)(A) AND (C) I WAS UNABLE TO FIND THE | | | SPECIAL INSPECTOR CERTIFICATION FOR ANDREW MORGAN, PE. | | | PROVIDE. | | | | | | | | | | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
4 |
Status |
P |
Date |
2018-02-28 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2018-02-28 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2018-02-28 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
3 |
Status |
F |
Date |
2018-02-27 |
|
|
Cont ID |
|
| Sent By |
LL |
Date |
2018-02-27 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2018-02-27 |
Time |
|
Sent To |
|
|
| Notes |
| 2018-02-27 16:57:27 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) SITE PLAN WITH DIMENSIONS MISSING FROM PERMIT | | | PACKAGE. PLEASE INCLUDE. | | | | | | 2.) NEW ELEVATION DRAWINGS INCOMPLETE. PLEASE ADDRESS. | | | | | | NOTES: | | | | | | * REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | | | | * ZONE: GC | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-09-19 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-09-19 |
Time |
|
Rev Time |
0.00 |
| Received By |
llouie |
Date |
2017-09-19 |
Time |
|
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
llouie |
Date |
2017-04-25 |
Time |
|
Rev Time |
|
| Received By |
llouie |
Date |
2017-04-25 |
Time |
|
Sent To |
|
|
| Notes |
| 2017-04-25 11:37:58 | ** FAILED ** | | | | | | PLEASE ADDRESS THE FOLLOWING COMMENTS. RESPOND TO THE | | | COMMENTS IN WRITING AND/OR ON THE PLANS WHERE | | | APPLICABLE: | | | | | | 1.) ZONING APPROVAL IS SUBJECT TO THE APPROVAL OF ISPR | | | 16-01B. ISPR 16-01B IS CURRENTLY PENDING WITH THE | | | PLANNING DIVISION (STAFF WAITING ON A RESUBMITTAL BY | | | THE APPLICANT). | | | | | | | | | NOTES: | | | | | | * PLEASE NOTE THAT THE BUILDING PERMIT PLANS WILL NEED | | | TO MATCHED THE PLANS PROVIDED IN APPLICATION ISPR | | | 16-01B ONCE APPROVED BY THE PLANNING DIVISION. | | | | | | * ANY REVISION MAY RESULT IN ADDITIONAL COMMENTS. | | | | | | * CONTACT LINDA LOUIE @ (561) 822-1458 IF THERE ARE | | | QUESTIONS. | | | |
|
|
|