Plan Review Details - Permit 17040762
Plan Review Stops For Permit 17040762
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-09 Cont ID  
Sent By shill Date 2017-05-09 Time 13:03 Rev Time 0.00
Received By shill Date 2017-05-08 Time 17:54 Sent To  
Notes
2017-05-09 10:47:40****CORRECTIONS****
  
 SAMANTHA HILL
 BUILDING PLANS EXAMINER
 [email protected]
 561-805-6724
  
 FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014)
 FBC B = FBC BUILDING
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
  
 1. THERE IS NO EVIDENCE OF A PERMIT FOR THE ENCLOSURE
 OF THE PORCH. PLANS FOR THE PORCH (PERMIT 11817J ISSUED
 3/20/87) SHOW A ROOF AND COLUMNS WITH MINIMAL
 ELECTRICAL WORK.
  
 EITHER PROVIDE THE PERMIT NUMBER UNDER WHICH THIS AREA
 WAS CONVERTED FROM AN OPEN PORCH TO ENCLOSED HABITABLE
 AREA, SUBMIT PLANS FOR THE PORCH CONVERSION, OR OBTAIN
 A PERMIT TO DEMOLISH THE WORK INSTALLED WITHOUT PERMIT.
  
 2. FBC 107, PLANS ARE TO BE ARCHITECTURAL QUALITY, TO
 SCALE, SUFFICIENT TO SHOW WORK PROPOSED. DO NOT LABEL
 ELEMENTS INSTALLED WITHOUT A PERMIT AS "EXISTING" AS
 "EXISTING" IS A TERM TO DESCRIBE ELEMENTS WHICH WERE
 PERMITTED, INSPECTED, OBTAINED FINAL INSPECTION, AND
 PERMIT CLOSED. ELEMENTS INSTALLED WITHOUT PERMIT, OR
 VIA A PERMIT WITH INCORRECT OR MISLEADING INFORMATION
 (SUCH AS THE WINDOW PERMIT WHICH CALLED THE WORK A
 "REPLACEMENT"), ARE SUGGESTED TO BE LABELED AS
 "PREVIOUSLY INSTALLED" OR OTHER SIMILAR LANGUAGE WITH A
 GENERAL NOTE TO CLARIFY THAT THE WORK HAS ALREADY BEEN
 DONE.
  
 A COMPLETE REVIEW CANNOT BE DONE AT THIS TIME DUE TO A
 LACK OF INFORMATION. SOME ITEMS TO INCLUDE ON THE PLAN:
  
 A BASIC FLOOR PLAN OF THE REAR OF THE HOUSE SHOWING
 ROOMS, ALL OPENINGS (BOTH OPENINGS STILL IN PLACE AND
 OPENINGS WHICH HAVE BEEN CLOSED UP) WITH DIMENSIONS AND
 WINDOW/DOOR TYPE
  
 FOR BEDROOMS ADJACENT TO THE PORCH, SHOW ALL OPENINGS
 TO THE OUTSIDE (WINDOWS AND DOORS) INCLUDING DIMENSIONS
  
 PROVIDE DETAILS FOR THE WALLS, FOUNDATION THROUGH THE
 ROOF. SHOW FINISHED FLOOR RELATIVE TO GRADE.
  
 WAS A CEILING INSTALLED? INSULATION? DRYWALL?
 DOORS/WINDOWS BETWEEN HOUSE AND PORCH LEFT IN PLACE, OR
 REMOVED? PLAN TO INCLUDE ALL ELEMENTS INSTALLED OR
 REMOVED.
  
 PLAN TO INCLUDE HOUSE EXISTING SQUARE FOOT UNDER AIR,
 PROPOSED "NEW" (PREVIOUSLY CONVERTED), NEW TOTAL - SEE
 ALSO IMPACT FEE REVIEW.
  
 3. SEE IMPACT FEE REVIEW.
  
 4. PERMIT VALUATION IS TO INCLUDE THE VALUE OF WORK,
 EVEN IF PREVIOUSLY DONE AND BEING PERMITTED AT THIS
 TIME, FBC 109.
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-09 Cont ID  
Sent By shill Date 2017-05-09 Time 10:49 Rev Time 0.00
Received By shill Date 2017-04-18 Time 10:54 Sent To B
Notes
2017-04-19 10:54:36ROUTED TO MECHANICAL INBOX

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-05-09 Cont ID  
Sent By shill Date 2017-05-09 Time 10:47 Rev Time 0.00
Received By shill Date 2017-05-09 Time 10:47 Sent To  
Notes
2017-05-09 10:49:18THE PLAN IS TO INCLUDE HOUSE EXISTING SQUARE FOOT UNDER
 AIR, PROPOSED "NEW" (PREVIOUSLY CONVERTED), NEW TOTAL
 UNDER AIR.
  
 PRIOR TO PERMIT ISSUANCE, AFTER PLAN HAS PASSED REVIEW,
 PLANS ARE TO BE TAKEN TO PALM BEACH COUNTY FOR IMPACT
 FEE ASSESSMENT. CONTACT 561-233-5525 FOR MORE
 INFORMATION.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-05-01 Cont ID  
Sent By ccole Date 2017-05-01 Time 08:33 Rev Time 0.00
Received By ccole Date 2017-05-01 Time 08:33 Sent To B
Notes
2017-05-01 08:43:341ST REVIEW FBC-2014 MECHANICAL
 PERMIT #17040762
 5/1/17
  
 1) THE PALM BEACH COUNTY PROPERTY APPRAISER'S REPORT
 INDICATES THE REAR PORCH TO BE A NON-CONDITIONED SPACE,
 THEREFORE THIS NEWLY CONDITIONED AREA MUST BE IN
 COMPLIANCE WITH THE FLORIDA ENERGY CONSERVATION CODE
 2014. PLEASE SEE SECTION R101.4.5 AND SUBMIT ENERGY
 CALCULATIONS. COMPLIANCE SUBMITTAL INFORMATION CAN BE
 FOUND UNDER SECTION R101.5. PLEASE NOTE THAT
  
 COMPLIANCE IS REQUIRED DESPITE THE FACT THAT THERE
 APPEARS TO HAVE BEEN A REPLACEMENT PERMIT ISSUED FOR
 THE SYSTEM IN 2005- HOWEVER THERE IS NO RECORD OF THE
 ORIGINAL AC PERMIT.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  