Plan Review Details - Permit 17040520
Plan Review Stops For Permit 17040520
Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2017-08-09 Cont ID  
Sent By cthroop Date 2017-08-09 Time 15:19 Rev Time 0.00
Received By cthroop Date 2017-08-09 Time 15:19 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2017-07-28 Cont ID  
Sent By cthroop Date 2017-07-28 Time 14:02 Rev Time 0.00
Received By cthroop Date 2017-07-28 Time 14:02 Sent To  
Notes
2017-07-28 15:02:26BUILDING APPROVAL CONTINGENT ON WINDOWS COMPLYING WITH
 ENERGY SUBMITTAL.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2017-07-27 Cont ID  
Sent By cthroop Date 2017-07-27 Time 09:11 Rev Time 0.00
Received By cthroop Date 2017-07-27 Time 09:10 Sent To  
Notes
2017-07-27 09:17:29BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 3RD REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. COMMENTS FROM 1ST & 2ND REVIEW HAVE NOT BEEN
 ADDRESSED.
 2. WINDOW PRODUCT APPROVAL NOA NO. 14-0722.07 IS FOR A
 NON-IMPACT RATED WINDOW. USE OF THIS PRODUCT SHALL MEET
 THE APPLICABLE REQUIREMENTS FOR WIND BORNE DEBRIS
 PROTECTION. OPENING PROTECTIVE DEVICE REQUIRED.
 2. 4X FEE WILL BE ASSESSED AT NEXT REVIEW FOR
 NON-COMPLIANCE OF REVIEW COMMENTS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW SUBMITTALS.
  
 F.S. 553.80 (2) (B)
 (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS?
 DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN
 ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING
 CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS
 REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO
 CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY
 NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO,
 EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY,
 ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL,
 MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER
 REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING
 COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL
 GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH
 REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION,
 A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE
 PERMIT FEE ATTRIBUTED TO PLANS REVIEW.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2017-06-13 Cont ID  
Sent By cthroop Date 2017-06-13 Time 07:36 Rev Time 0.00
Received By cthroop Date 2017-06-12 Time 10:01 Sent To  
Notes
2017-06-13 07:39:20BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 2ND REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PLANS SPECIFY IMPACT WINDOWS TO BE INSTALLED.
 2. NOA 14-0722.07 IS FOR NON-IMPACT RATED WINDOW.
 PLEASE CLARIFY.
 3. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE WINDOW AND WINDOW MULLION
 SUBMITTALS.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-10 Cont ID  
Sent By rmcdouga Date 2017-05-10 Time 15:11 Rev Time 0.00
Received By rmcdouga Date 2017-05-10 Time 14:59 Sent To  
Notes
2017-05-10 15:11:21PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC FIFTH EDITION (2014)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) FBC 107.3.4 - PROVIDE TWO (2) SETS OF PRODUCT
 APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC
 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE
 BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER
 OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH
 FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS
 AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT
 WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND EXTERIOR
 DOOR TYPES.
  
 2) THE VALUATION FOR THE WORK OF $3900.00 IS LOW FOR
 THE WORK THAT IS SPECIFIED. PROVIDE AN ACCURATE
 VALUATION. FBC 109.3 BUILDING PERMIT VALUATION. FOR
 PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS
 SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL,
 ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH,
 RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES,
 MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY
 LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST
 PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS
 SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY
 INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT
 VALUATION SHALL BE SET BY THE BUILDING OFFICIAL.
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-06-09 Cont ID  
Sent By jpearson Date 2017-06-09 Time 10:30 Rev Time 0.00
Received By jpearson Date 2017-06-09 Time 10:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-04-26 Cont ID  
Sent By vperez Date 2017-04-26 Time 09:20 Rev Time 0.00
Received By vperez Date 2017-04-26 Time 09:20 Sent To  
Notes
2017-04-26 09:20:34INITIAL ELECTRICAL PLAN REVIEW
  
 APPLICABLE CODES IN EFFECT:
 FLORIDA RES BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH
 EDITION
 NFPA 70- 2011
 COMMENTS:
  
 1. GENERAL NOTE TO INDICATED REQUIRED SEPARATE PERMITS
 FOR LOW VOLTAGE SYSTEMS. FBC 107.3.5
 2. SHOW AN INTERSYSTEM BONDING TERMINAL AT THE SERVICE
 PER FBC RES E3609.3
 3. SHOW EXTERIOR RECEPTACLE AT FRONT ENTRANCE TO MAIN
 HOUSE PROTECTED BY GFCI DEVICE. FBC RES E3902.3
 4. SHOW A RECEPTACLE W/P GFCI PROTECTED AT THE HVAC AC
 LOCATION FOR SERVICE PER FBC RES E3901.12 HVAC OUTLET/
 MAIN HOUSE
 5. PROVIDE A NOTE PER FBC ENERGY CONSERVATION CODE TO
 INDICATE; 75% OF LAMPS TO HIGH EFFICACY LAMPS.
 6. PROVIDE A ONE-LINE RISER DIAGRAM FOR THE ELECTRICAL
 SERVICE. FBC 107.3.5
 7. MAIN CB TO BE LOCATED OUTSIDE THE DWELLING. IF
 INSIDE BACK TO BACK SERVICE CONDUCTOR LENGTH WILL BE
 LIMITED PER THE AHJ. PROVIDE A NOTE.
 8. SHOW BONDING AND GROUNDING REQUIREMENTS.
 9. FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY
 QUESTIONS OR CONCERNS.
 VALENTINO PEREZ
 ELECTRICAL PLANS EXAMINER II
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-08-09 Cont ID  
Sent By cthroop Date 2017-08-09 Time 15:19 Rev Time 0.00
Received By cthroop Date 2017-08-07 Time 13:13 Sent To  
Notes
2017-08-08 13:13:55RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-07-27 Cont ID  
Sent By cthroop Date 2017-07-27 Time 09:11 Rev Time 0.00
Received By cthroop Date 2017-07-24 Time 15:39 Sent To  
Notes
2017-07-25 15:40:12RESUB ROUTED TO CCOLE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2017-06-16 Time   Rev Time 0.00
Received By lmarchan Date 2017-06-06 Time 10:23 Sent To  
Notes
2017-06-07 10:23:25R22

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-10 Cont ID  
Sent By rmcdouga Date 2017-05-10 Time 15:38 Rev Time 0.00
Received By rmcdouga Date 2017-04-11 Time 13:41 Sent To  
Notes
2017-04-12 13:41:28R21

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2017-08-08 Cont ID  
Sent By ccole Date 2017-08-08 Time 17:37 Rev Time 0.00
Received By ccole Date 2017-08-08 Time 17:37 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2017-07-26 Cont ID  
Sent By ccole Date 2017-07-26 Time 07:38 Rev Time 0.00
Received By ccole Date 2017-07-25 Time 17:23 Sent To  
Notes
2017-07-26 07:41:422ND REVIEW FBC-2014 MECHANICAL
 PERMIT #17040520
 7/26/17
  
 THE COMMENTS FROM THE 1ST REVIEW STILL EXISTS. I HAVE
 REPRINTED THEM BELOW. PLEASE NOTE THE SUBMITTED
 CONTRACT FROM AM-PM AC INC. INDICATES A VALUE OF
 $4950.00 FOR THE AC WORK, HOWEVER THE RESUBMITTAL
 APPLICATION IS ONLY INDICATING AN INCREASE OF $495.00.
 I AM ASSUMING THIS IS A TYPO- PLEASE CORRECT.
  
 1ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL
 PERMIT #17040520
 6/16/17
  
 1) THE PREVIOUS REVIEW OF THE PROPOSED PROJECT
 INDICATES THAT NO PLANS OR JOB VALUE WAS PROVIDED FOR
 THE MECHANICAL WORK. NOW THAT PLANS AND A MECHANICAL
 SUB-PERMIT APPLICAION HAVE BEEN SUBMITTED, THE TOTAL
 VALUE OF THE PROJECT MUST INCREASE ACCORDINGLY. PLEASE
 PROVIDE A SIGNED CONTRACT FOR THE PROPOSED AC WORK, AND
 ADJUST THE VALUE ON THE PERMIT APPLICATION- SECTION
  
 109.3 WPB AMENDMENTS TO THE FBC.
  
 2) THE PROPOSED PROJECT SHALL BE IN COMPLIANCE WITH
 SECTION R101.4.3 FBC-14 ENERGY CONSERVATION. REFER TO
 SECTION R101.5.1 AND SUBMIT EITHER FORM R402 OR R405 TO
 VERIFY COMPLIANCE.
  
 3) SUBMIT THE MIAMI-DADE NOA FOR THE CONDENSER TIE-DOWN
 CLIPS, AND PLACE THE NOA NUMBER AT THE CU MOUNTING
 DETAIL ON SHEET M-1.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2017-06-16 Cont ID  
Sent By ccole Date 2017-06-16 Time 12:31 Rev Time 0.00
Received By ccole Date 2017-06-16 Time 12:30 Sent To  
Notes
2017-06-16 12:34:031ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL
 PERMIT #17040520
 6/16/17
  
 1) THE PREVIOUS REVIEW OF THE PROPOSED PROJECT
 INDICATES THAT NO PLANS OR JOB VALUE WAS PROVIDED FOR
 THE MECHANICAL WORK. NOW THAT PLANS AND A MECHANICAL
 SUB-PERMIT APPLICAION HAVE BEEN SUBMITTED, THE TOTAL
 VALUE OF THE PROJECT MUST INCREASE ACCORDINGLY. PLEASE
 PROVIDE A SIGNED CONTRACT FOR THE PROPOSED AC WORK, AND
 ADJUST THE VALUE ON THE PERMIT APPLICATION- SECTION
  
 109.3 WPB AMENDMENTS TO THE FBC.
  
 2) THE PROPOSED PROJECT SHALL BE IN COMPLIANCE WITH
 SECTION R101.4.3 FBC-14 ENERGY CONSERVATION. REFER TO
 SECTION R101.5.1 AND SUBMIT EITHER FORM R402 OR R405 TO
 VERIFY COMPLIANCE.
  
 3) SUBMIT THE MIAMI-DADE NOA FOR THE CONDENSER TIE-DOWN
 CLIPS, AND PLACE THE NOA NUMBER AT THE CU MOUNTING
 DETAIL ON SHEET M-1.
  
 CHRISTOPHER L. COLE
 MECHANICAL PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2017-05-10 Cont ID  
Sent By rmcdouga Date 2017-05-10 Time 15:38 Rev Time 0.00
Received By rmcdouga Date 2017-05-10 Time 15:38 Sent To  
Notes
2017-05-10 15:38:37NO MECHANICAL WORK IS SHOWN ON THE PLANS. NOTE UNDER
 SCOPE OF WORKS STATES THAT THE A/C EQUIPMENT AND DUCT
 WORK ARE TO BE REPLACED BY THE A/C CONTRACTOR. SUBMIT
 EQUIPMENT SIZING CALCULATIONS, AHRI CERTIFICATIONS FOR
 THE EQUIPMENT AND PLANS FOR THE DUCTWORK WITH AN
 EQUIPMENT SCHEDULE UNDER A SEPARATE PERMIT. A SEPARATE
 PERMIT, APPLICATION AND PLANS ARE REQUIRED. DO NOT
 INCLUDE THE COST OF THIS WORK IN THE MASTER PERMIT. THE
 VALUE OF THE A/C WORK WILL BE USED FOR THE SEPARATE
 MECHANICAL PERMIT.

Review Stop P PLUMBING
Rev No 2 Status P Date 2017-06-15 Cont ID  
Sent By gjohnson Date 2017-06-15 Time 08:16 Rev Time 0.00
Received By gjohnson Date 2017-06-15 Time 08:16 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-04-28 Cont ID  
Sent By gjohnson Date 2017-04-28 Time 07:55 Rev Time 0.00
Received By gjohnson Date 2017-04-28 Time 07:29 Sent To  
Notes
2017-04-28 08:02:341ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. THE DOWN STAIRS BATHROOM GROUP SHALL BE VENTED
 SEPARATELY FROM THE SOIL STACK THE KITCHEN SHALL ALSO
 BE VENTED SEPARATELY. PER FBCRES P3101.2.1 , P3108.1
  
 2. A CLEAN OUT IS REQUIRED AT THE BASE OF THE SOIL
 STACK. PER FBCRES P3005.2.6
  
  
 FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT
 THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL
 COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  