| Plan Review Stops For Permit 17040520 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
5 |
Status |
P |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-09 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-09 |
Time |
15:19 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
4 |
Status |
F |
Date |
2017-07-28 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-28 |
Time |
14:02 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-28 |
Time |
14:02 |
Sent To |
|
|
| Notes |
| 2017-07-28 15:02:26 | BUILDING APPROVAL CONTINGENT ON WINDOWS COMPLYING WITH | | | ENERGY SUBMITTAL. |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
F |
Date |
2017-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-27 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-27 |
Time |
09:10 |
Sent To |
|
|
| Notes |
| 2017-07-27 09:17:29 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 3RD REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. COMMENTS FROM 1ST & 2ND REVIEW HAVE NOT BEEN | | | ADDRESSED. | | | 2. WINDOW PRODUCT APPROVAL NOA NO. 14-0722.07 IS FOR A | | | NON-IMPACT RATED WINDOW. USE OF THIS PRODUCT SHALL MEET | | | THE APPLICABLE REQUIREMENTS FOR WIND BORNE DEBRIS | | | PROTECTION. OPENING PROTECTIVE DEVICE REQUIRED. | | | 2. 4X FEE WILL BE ASSESSED AT NEXT REVIEW FOR | | | NON-COMPLIANCE OF REVIEW COMMENTS. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW SUBMITTALS. | | | | | | F.S. 553.80 (2) (B) | | | (B)?WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS? | | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-13 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-06-13 |
Time |
07:36 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-06-12 |
Time |
10:01 |
Sent To |
|
|
| Notes |
| 2017-06-13 07:39:20 | BUILDING PLAN REVIEW | | | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH | | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 | | | ADMINISTRATION | | | | | | CHRISTOPHER S. THROOP, C.B.O. | | | PLANS EXAMINER, PX3169 | | | CONSTRUCTION SERVICES DIVISION | | | TEL: 561-805-6726 | | | FAX: 561-805-6676 | | | | | | 2ND REVIEW | | | RESULTS: DENIED | | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | | | | | 1. PLANS SPECIFY IMPACT WINDOWS TO BE INSTALLED. | | | 2. NOA 14-0722.07 IS FOR NON-IMPACT RATED WINDOW. | | | PLEASE CLARIFY. | | | 3. PROVIDE PRODUCT APPROVALS FOR WINDOW MULLIONS. | | | | | | FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE | | | PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED | | | AND APPROVED IN WRITING BY THE DESIGNER OF RECORD. | | | SPECIFICALLY, PROVIDE WINDOW AND WINDOW MULLION | | | SUBMITTALS. | | | | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-10 |
Time |
15:11 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-10 |
Time |
14:59 |
Sent To |
|
|
| Notes |
| 2017-05-10 15:11:21 | PLAN | | | REVIEW COMMENTS | | | | | | 1ST REVIEW: FBC FIFTH EDITION (2014) | | | ROBERT MCDOUGAL, CBO | | | COMMERCIAL COMBINATION PLANS EXAMINER | | | (561) 805-6714 | | | [email protected] | | | | | | DENIED BY BUILDING | | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | | | 1) FBC 107.3.4 - PROVIDE TWO (2) SETS OF PRODUCT | | | APPROVALS FOR THOSE PRODUCTS WHICH ARE REGULATED BY FAC | | | 61G20-3.001 PER FLORIDA STATUTE 553.842 (5) THAT HAVE | | | BEEN REVIEWED AND APPROVED IN WRITING BY THE DESIGNER | | | OF RECORD. PROVIDE TWO COMPLETE PRODUCT APPROVALS WITH | | | FL OR NOA NUMBERS INCLUDING INSTALLATION INSTRUCTIONS | | | AND MAXIMUM DESIGN PRESSURES FOR EACH OF THE DIFFERENT | | | WINDOW/GLASS TYPES, STRUCTURAL MULLIONS AND EXTERIOR | | | DOOR TYPES. | | | | | | 2) THE VALUATION FOR THE WORK OF $3900.00 IS LOW FOR | | | THE WORK THAT IS SPECIFIED. PROVIDE AN ACCURATE | | | VALUATION. FBC 109.3 BUILDING PERMIT VALUATION. FOR | | | PERMITTING PURPOSES, VALUATION OF BUILDINGS AND SYSTEMS | | | SHALL BE TOTAL REPLACEMENT VALUE TO INCLUDE STRUCTURAL, | | | ELECTRIC, PLUMBING, MECHANICAL, INTERIOR FINISH, | | | RELATIVE SITE WORK, ARCHITECTURAL AND DESIGN FEES, | | | MARKETING COSTS, OVERHEAD AND PROFIT; EXCLUDING ONLY | | | LAND VALUE. VALUATION REFERENCES MAY INCLUDE THE LATEST | | | PUBLISHED DATA OF NATIONAL CONSTRUCTION COST ANALYSIS | | | SERVICES (MARSHALL-SWIFT, MEANS, ETC.), AS PUBLISHED BY | | | INTERNATIONAL CODE CONGRESS. FINAL BUILDING PERMIT | | | VALUATION SHALL BE SET BY THE BUILDING OFFICIAL. | | | | | | | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-06-09 |
|
|
Cont ID |
|
| Sent By |
jpearson |
Date |
2017-06-09 |
Time |
10:30 |
Rev Time |
0.00 |
| Received By |
jpearson |
Date |
2017-06-09 |
Time |
10:30 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-04-26 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-04-26 |
Time |
09:20 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-04-26 |
Time |
09:20 |
Sent To |
|
|
| Notes |
| 2017-04-26 09:20:34 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA RES BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. GENERAL NOTE TO INDICATED REQUIRED SEPARATE PERMITS | | | FOR LOW VOLTAGE SYSTEMS. FBC 107.3.5 | | | 2. SHOW AN INTERSYSTEM BONDING TERMINAL AT THE SERVICE | | | PER FBC RES E3609.3 | | | 3. SHOW EXTERIOR RECEPTACLE AT FRONT ENTRANCE TO MAIN | | | HOUSE PROTECTED BY GFCI DEVICE. FBC RES E3902.3 | | | 4. SHOW A RECEPTACLE W/P GFCI PROTECTED AT THE HVAC AC | | | LOCATION FOR SERVICE PER FBC RES E3901.12 HVAC OUTLET/ | | | MAIN HOUSE | | | 5. PROVIDE A NOTE PER FBC ENERGY CONSERVATION CODE TO | | | INDICATE; 75% OF LAMPS TO HIGH EFFICACY LAMPS. | | | 6. PROVIDE A ONE-LINE RISER DIAGRAM FOR THE ELECTRICAL | | | SERVICE. FBC 107.3.5 | | | 7. MAIN CB TO BE LOCATED OUTSIDE THE DWELLING. IF | | | INSIDE BACK TO BACK SERVICE CONDUCTOR LENGTH WILL BE | | | LIMITED PER THE AHJ. PROVIDE A NOTE. | | | 8. SHOW BONDING AND GROUNDING REQUIREMENTS. | | | 9. FEEL FREE TO CONTACT ME SHOULD YOU HAVE ANY | | | QUESTIONS OR CONCERNS. | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-08-09 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-08-09 |
Time |
15:19 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-08-07 |
Time |
13:13 |
Sent To |
|
|
| Notes |
| 2017-08-08 13:13:55 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-07-27 |
|
|
Cont ID |
|
| Sent By |
cthroop |
Date |
2017-07-27 |
Time |
09:11 |
Rev Time |
0.00 |
| Received By |
cthroop |
Date |
2017-07-24 |
Time |
15:39 |
Sent To |
|
|
| Notes |
| 2017-07-25 15:40:12 | RESUB ROUTED TO CCOLE |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
| Sent By |
|
Date |
2017-06-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-06-06 |
Time |
10:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-10 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-04-11 |
Time |
13:41 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
4 |
Status |
P |
Date |
2017-08-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-08-08 |
Time |
17:37 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-08-08 |
Time |
17:37 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
F |
Date |
2017-07-26 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-07-26 |
Time |
07:38 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-07-25 |
Time |
17:23 |
Sent To |
|
|
| Notes |
| 2017-07-26 07:41:42 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17040520 | | | 7/26/17 | | | | | | THE COMMENTS FROM THE 1ST REVIEW STILL EXISTS. I HAVE | | | REPRINTED THEM BELOW. PLEASE NOTE THE SUBMITTED | | | CONTRACT FROM AM-PM AC INC. INDICATES A VALUE OF | | | $4950.00 FOR THE AC WORK, HOWEVER THE RESUBMITTAL | | | APPLICATION IS ONLY INDICATING AN INCREASE OF $495.00. | | | I AM ASSUMING THIS IS A TYPO- PLEASE CORRECT. | | | | | | 1ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL | | | PERMIT #17040520 | | | 6/16/17 | | | | | | 1) THE PREVIOUS REVIEW OF THE PROPOSED PROJECT | | | INDICATES THAT NO PLANS OR JOB VALUE WAS PROVIDED FOR | | | THE MECHANICAL WORK. NOW THAT PLANS AND A MECHANICAL | | | SUB-PERMIT APPLICAION HAVE BEEN SUBMITTED, THE TOTAL | | | VALUE OF THE PROJECT MUST INCREASE ACCORDINGLY. PLEASE | | | PROVIDE A SIGNED CONTRACT FOR THE PROPOSED AC WORK, AND | | | ADJUST THE VALUE ON THE PERMIT APPLICATION- SECTION | | | | | | 109.3 WPB AMENDMENTS TO THE FBC. | | | | | | 2) THE PROPOSED PROJECT SHALL BE IN COMPLIANCE WITH | | | SECTION R101.4.3 FBC-14 ENERGY CONSERVATION. REFER TO | | | SECTION R101.5.1 AND SUBMIT EITHER FORM R402 OR R405 TO | | | VERIFY COMPLIANCE. | | | | | | 3) SUBMIT THE MIAMI-DADE NOA FOR THE CONDENSER TIE-DOWN | | | CLIPS, AND PLACE THE NOA NUMBER AT THE CU MOUNTING | | | DETAIL ON SHEET M-1. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-06-16 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-06-16 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-06-16 |
Time |
12:30 |
Sent To |
|
|
| Notes |
| 2017-06-16 12:34:03 | 1ST REVIEW FBC-2014 RESIDENTIAL MECHANICAL | | | PERMIT #17040520 | | | 6/16/17 | | | | | | 1) THE PREVIOUS REVIEW OF THE PROPOSED PROJECT | | | INDICATES THAT NO PLANS OR JOB VALUE WAS PROVIDED FOR | | | THE MECHANICAL WORK. NOW THAT PLANS AND A MECHANICAL | | | SUB-PERMIT APPLICAION HAVE BEEN SUBMITTED, THE TOTAL | | | VALUE OF THE PROJECT MUST INCREASE ACCORDINGLY. PLEASE | | | PROVIDE A SIGNED CONTRACT FOR THE PROPOSED AC WORK, AND | | | ADJUST THE VALUE ON THE PERMIT APPLICATION- SECTION | | | | | | 109.3 WPB AMENDMENTS TO THE FBC. | | | | | | 2) THE PROPOSED PROJECT SHALL BE IN COMPLIANCE WITH | | | SECTION R101.4.3 FBC-14 ENERGY CONSERVATION. REFER TO | | | SECTION R101.5.1 AND SUBMIT EITHER FORM R402 OR R405 TO | | | VERIFY COMPLIANCE. | | | | | | 3) SUBMIT THE MIAMI-DADE NOA FOR THE CONDENSER TIE-DOWN | | | CLIPS, AND PLACE THE NOA NUMBER AT THE CU MOUNTING | | | DETAIL ON SHEET M-1. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
N |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
rmcdouga |
Date |
2017-05-10 |
Time |
15:38 |
Rev Time |
0.00 |
| Received By |
rmcdouga |
Date |
2017-05-10 |
Time |
15:38 |
Sent To |
|
|
| Notes |
| 2017-05-10 15:38:37 | NO MECHANICAL WORK IS SHOWN ON THE PLANS. NOTE UNDER | | | SCOPE OF WORKS STATES THAT THE A/C EQUIPMENT AND DUCT | | | WORK ARE TO BE REPLACED BY THE A/C CONTRACTOR. SUBMIT | | | EQUIPMENT SIZING CALCULATIONS, AHRI CERTIFICATIONS FOR | | | THE EQUIPMENT AND PLANS FOR THE DUCTWORK WITH AN | | | EQUIPMENT SCHEDULE UNDER A SEPARATE PERMIT. A SEPARATE | | | PERMIT, APPLICATION AND PLANS ARE REQUIRED. DO NOT | | | INCLUDE THE COST OF THIS WORK IN THE MASTER PERMIT. THE | | | VALUE OF THE A/C WORK WILL BE USED FOR THE SEPARATE | | | MECHANICAL PERMIT. |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-06-15 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-06-15 |
Time |
08:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-06-15 |
Time |
08:16 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-04-28 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-28 |
Time |
07:55 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-28 |
Time |
07:29 |
Sent To |
|
|
| Notes |
| 2017-04-28 08:02:34 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. THE DOWN STAIRS BATHROOM GROUP SHALL BE VENTED | | | SEPARATELY FROM THE SOIL STACK THE KITCHEN SHALL ALSO | | | BE VENTED SEPARATELY. PER FBCRES P3101.2.1 , P3108.1 | | | | | | 2. A CLEAN OUT IS REQUIRED AT THE BASE OF THE SOIL | | | STACK. PER FBCRES P3005.2.6 | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|