Plan Review Details - Permit 17040244
Plan Review Stops For Permit 17040244
Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-04-26 Cont ID  
Sent By tklarge Date 2017-04-26 Time 05:08 Rev Time 0.00
Received By tklarge Date 2017-04-24 Time 08:37 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-04-18 Cont ID  
Sent By tklarge Date 2017-04-18 Time 05:13 Rev Time 0.00
Received By tklarge Date 2017-04-17 Time 06:04 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-04-07 Cont ID  
Sent By gjohnson Date 2017-04-07 Time 16:35 Rev Time 0.00
Received By gjohnson Date 2017-04-07 Time 16:35 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-04-26 Cont ID  
Sent By tklarge Date 2017-04-26 Time 05:07 Rev Time 0.00
Received By tklarge Date 2017-04-24 Time 08:37 Sent To  
Notes
2017-04-24 08:37:59APPROVED BY PLUMBING/SENT TO UTILITIES FOR REVIEW. TKL.
 4/24/17.

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-04-18 Cont ID  
Sent By tklarge Date 2017-04-18 Time 05:13 Rev Time 0.00
Received By tklarge Date 2017-04-17 Time 06:07 Sent To  
Notes
2017-04-18 04:50:321) THIS DEVICE IS NOT LISTED ON THE USC WEBSITE AS AN
 APPROVED DEVICE AS REQUIRED BY THE CWPB
 CROSS-CONNECTION CONTROL MANUAL AND THEREFORE CANNOT BE
 USED.
 2) SUBMIT A PLAN SHOWING THE LOCATION AN APPROVED
 BACKFLOW PREVENTER. IF THERE IS A SEPARATE METER
 DEDICATED TO THE IRRIGATION SYSTEM, THEN THE MINIMUM
 LEVEL OF PROTECTION SHALL BE A DOUBLE CHECK VALVE
 ASSEMBLY PER THE CWPB CROSS-CONNECTION CONTROL MANUAL.
 3) SUBMIT A DETAIL SHOWING THE ARRANGEMENT OF THE
 BACKFLOW PREVENTER ON THE IRRIGATION SYSTEM. AN
 ATMOSPHERIC BACKFLOW PREVENTER DEVICE IS NOT FOR USE
 UNDER CONTINUOUS PRESSURE SO IT WOULD HAVE TO BE
 LOCATED DOWNSTREAM OF A SOLENOID VALVE ON THE SYSTEM.
 CLARIFY.
 4) THIS DEVICE (288A) IS DESIGNED FOR LOW FLOW WATER
 INSTALLATIONS AND DOES NOT APPEAR TO BE APPROPRIATE FOR
 AN IRRIGATION SYSTEM APPLICATION.
  
 TIM LARGE
 CHIEF PLUMBING INSPECTOR
 PLUMBING PLAN REVIEW
 561-805-6692
 [email protected]
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-04-07 Cont ID  
Sent By gjohnson Date 2017-04-07 Time 16:35 Rev Time 0.00
Received By gjohnson Date 2017-04-07 Time 16:35 Sent To  
Notes
2017-04-07 16:48:211ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. DEVICE IS NOT LEAD FREE AND CAN NOT BE USED IN
 CONNECTION OF POTABLE WATER SYSTEMS. PER FBC PL 605.2.1
  
 2. DEVICES SHALL BE APPROVED FOR LEAD FREE ON THE
 UNIVERSITY OF SOUTHERN CALIFORNIA'S LIST OF APPROVED
 DEVICES. PER WPB UTILITIES CROSS CONNECTION CONTROL
 MANUAL
  
  
 FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT
 THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL
 COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  