| Plan Review Stops For Permit 17040239 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
3 |
Status |
P |
Date |
2017-05-19 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-19 |
Time |
07:11 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-19 |
Time |
06:42 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-10 |
Time |
07:40 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-10 |
Time |
07:26 |
Sent To |
|
|
| Notes |
| 2017-05-10 07:46:04 | ****PROVISO**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. VALUE HAS BEEN ADJUSTED; SEE FRONT SCREEN NOTES. IF | | | APPLICANT OBJECTS TO VALUE ASSIGNED TO PROJECT OR DEMO | | | WORK (4X FEE), CONTACT ME PRIOR TO PERMIT ISSUANCE. | | | | | | 2. A DETAIL FOR THE RAMP WAS NOT PROVIDED. THE RAMP AND | | | RAIL ARE TO COMPLY WITH FBC A 405, 505. SUBJECT TO THE | | | FIELD INSPECTOR'S DISCRETION, A REVISION MAY BE | | | REQUIRED. | | | |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
F |
Date |
2017-04-14 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-04-14 |
Time |
15:59 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-14 |
Time |
15:50 |
Sent To |
|
|
| Notes |
| 2017-04-14 16:00:14 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | 1. ACCESSIBLE ROUTE TO THE ALTERED AREA IS REQUIRED, | | | FBC A 202.4. THE ENTRY DOOR DOES NOT MEET THE | | | REQUIREMENTS OF FBC A 303. | | | | | | 2. FBC 109, PROVIDE A COPY OF THE CONTRACT FOR THIS | | | JOB. ADDITIONAL INFORMATION MAY BE REQUIRED. | | | | | | 3. A01 RESTROOM DETAILS INCLUDE OUTDATED REFERENCES (CH | | | 11) AND DETAIL NOT COMPLIANT, SEE GRAB BAR HEIGHT | | | REQUIREMENT TO BE MEASURED TO TOP OF BAR, FBC A 609.4. | | | CHECK ALL DETAILS. | | | |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-15 |
Time |
08:56 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-15 |
Time |
08:56 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-04-21 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-04-21 |
Time |
08:27 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-04-21 |
Time |
08:27 |
Sent To |
|
|
| Notes |
| 2017-04-21 08:32:36 | INITIAL ELECTRICAL PLAN REVIEW | | | | | | APPLICABLE CODES IN EFFECT: | | | FLORIDA BUILDING CODE 2014 5TH EDITION | | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2014 5TH | | | EDITION | | | NFPA 70- 2011 | | | COMMENTS: | | | | | | 1. GENERAL NOTES TO CONSTRUCTION DOCUMENTS: PLEASE | | | PROVIDE A BLOCK NOTE INDICATING THE REQUIRED SEPARATE | | | PERMITS AND DATA SPECIFICATION SHEET SUBMITTALS FOR ALL | | | LOW VOLTAGE SYSTEMS TO INCLUDE BUT NOT LIMITED TO CCTV, | | | PHONE AND DATA, WIRELESS SYSTEMS, ETC. A NOTE WILL | | | SUFFICE. | | | 2. PLEASE LABEL ALL RECEPTACLES WITHIN 6FT OF ALL | | | SINKS, SEE MULTIPLE LOCATIONS. NEC 210.8B | | | 3. ADD RECEPTACLE FOR AC ON ROOFTOP WITHIN 25FT OF | | | UNIT, SHOW IF EXISTING. FBC 107.3.5 | | | 4. COMMENTS MAY FOLLOW UPON RE-REVIEW. PLEASE FEEL FREE | | | TO CONTACT ME SHOULD YOU HAVE ANY | | | | | | | | | VALENTINO PEREZ | | | ELECTRICAL PLANS EXAMINER II | | | 561-805-6717 | | | [email protected] | | | | | | | | | | | | | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-05-16 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-16 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-15 |
Time |
17:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-04-13 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-04-13 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-04-13 |
Time |
09:32 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
4 |
Status |
N |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-30 |
Time |
16:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-26 |
Time |
10:08 |
Sent To |
|
|
| Notes |
| 2017-05-30 10:08:48 | IMPACT FEES ROUTED TO SHILL |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
3 |
Status |
N |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
lmarchan |
Date |
2017-05-30 |
Time |
10:08 |
Rev Time |
0.00 |
| Received By |
lmarchan |
Date |
2017-05-17 |
Time |
12:04 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-17 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-08 |
Time |
14:23 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-25 |
Time |
10:05 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-08 |
Time |
14:22 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
2 |
Status |
P |
Date |
2017-05-30 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-30 |
Time |
16:37 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-30 |
Time |
16:37 |
Sent To |
|
|
| Notes |
| 2017-05-30 16:38:17 | PLAN STAMPED; NO MU NUMBER, $0 DUE | | | | | | |
|
|
| Review Stop |
IMPACT |
COUNTY IMPACT FEES |
| Rev No |
1 |
Status |
F |
Date |
2017-05-10 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-10 |
Time |
08:08 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-10 |
Time |
08:08 |
Sent To |
|
|
| Notes |
| 2017-05-10 08:09:17 | ****CORRECTIONS**** | | | | | | SAMANTHA HILL | | | BUILDING PLANS EXAMINER | | | [email protected] | | | 561-805-6724 | | | | | | FBC = FLORIDA BUILDING CODE, 5TH EDITION (2014) | | | FBC B = FBC BUILDING | | | FBC EB = FBC EXISTING BUILDING | | | FBC A = FBC ACCESSIBILITY | | | FBC EC = FBC ENERGY CONSERVATION | | | | | | IMPACT FEE ASSESSMENT BY PALM BEACH COUNTY IS REQUIRED | | | (PER W.SWOPE). CONTACT 561-233-5025 FOR MORE | | | INFORMATION. | | | | | | THE PLANS ARE TO BE STAMPED AND THE RECEIPT SHOWING | | | THAT ANY FEES DUE HAVE BEEN PAID ARE TO BE PROVIDED. | | | | | | THIS MAY BE DONE AFTER ALL REVIEWS ARE COMPLETE, BUT | | | MUST BE DONE PRIOR TO PERMIT ISSUANCE. | | | | | | | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
3 |
Status |
P |
Date |
2017-05-23 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-23 |
Time |
11:26 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-23 |
Time |
11:26 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
F |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-12 |
Time |
17:14 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-12 |
Time |
17:14 |
Sent To |
|
|
| Notes |
| 2017-05-12 17:18:27 | 2ND REVIEW FBC-2014 MECHANICAL | | | PERMIT #17040239 | | | 5/12/17 | | | | | | RESULTS: DENIED. | | | | | | 1) THE REQUESTED VENTILATION CALCULATIONS WERE NOT | | | PROVIDED, AND THE PLAN DOES NOT SHOW HOW THE REQUIRED | | | OUTSIDE AIR IS BEING PROVIDED INTO THE SPACE. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-04-12 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-12 |
Time |
14:41 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-04-12 |
Time |
14:41 |
Sent To |
|
|
| Notes |
| 2017-04-12 15:08:01 | 1ST REVIEW FBC-2014 MECHANICAL, EXISTING BUILDING CODES | | | PERMIT #17040239 | | | 4/12/17 | | | | | | 1) REFER TO SECTION 809.2 FBC-14 EXISTING BUILDING CODE | | | AND PROVIDE MINIMUM VENTILATION CALCULATIONS FOR ALL | | | ROOMS AND SPACES PER TABLE 403.3 FBC-14 MECHANICAL. | | | PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND | | | PROVIDED CFMS OF OUTDOOR AIR. | | | | | | 2) REFER TO SECTION C403.2.7.5 FBC-14 ENERGY | | | CONSERVATION AND INDICATE HOW THE AIR DISTRIBUTION | | | SYSTEM WAS SIZED AND DESIGNED. | | | | | | 3) A MEANS OF RETURN AIR OTHER THAN UNDERCUTTING DOORS | | | IS REQUIRED FOR THE TREATMENT ROOMS AND THE OFFICE- SEE | | | SECTION 601.5 | | | | | | 4) THE SPA SERVICES NOTES ON SHEET A-01 INDICATES | | | MANICURES WILL BE PERFORMED. PLEASE SHOW THE LOCATIONS | | | OF THE NAIL STATIONS AND PROVIDE EXHAUST SYSTEMS IN | | | COMPLIANCE WITH TABLE 403.3 . | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-05-17 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-17 |
Time |
10:48 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-15 |
Time |
09:28 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-04-25 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-25 |
Time |
09:16 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-25 |
Time |
09:16 |
Sent To |
|
|
| Notes |
| 2017-04-25 10:02:38 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. SHOW COMPLIANCE WITH FBC ACC 604.7 DISPENSERS. | | | TOILET PAPER DISPENSERS SHALL COMPLY WITH 309.4 AND | | | SHALL BE 7 INCHES (180 MM) MINIMUM AND 9 INCHES (230 | | | MM) MAXIMUM IN FRONT OF THE WATER CLOSET MEASURED TO | | | THE CENTERLINE OF THE DISPENSER. | | | | | | 2. GRAB BARS ARE TO BE MEASURED FROM THE TOP OF THE | | | GRIPPING SURFACE TO FINISHED FLOOR NOT THE CENTER OF | | | THE BAR. PER FBC ACC 609.4 | | | | | | 3.THE BREAK ROOM SINK AND AT LEAST ONE OF THE TREATMENT | | | ROOM SINKS SHALL COMPLY WITH FBC ACC 606.2 CLEAR FLOOR | | | SPACE. | | | A CLEAR FLOOR SPACE COMPLYING WITH 305, POSITIONED FOR | | | A FORWARD APPROACH, AND KNEE AND TOE CLEARANCE | | | COMPLYING WITH 306 SHALL BE PROVIDED. | | | | | | 4. THE SHOWER SHALL COMPLY WITH ONE OF THE SHOWER TYPES | | | IN FBC ACC 608 PROVIDE DIMENSIONS AND MOUNTING HEIGHTS | | | ON THE PLAN. PER WPB AMEND TO FBC 107.2.1 | | | | | | 5. THE BRANCH DRAIN FOR THE TREATMENT ROOM SINKS AND | | | BREAK ROOM SINK SHALL CONNECT TO THE BUILDING DRAIN | | | DOWN STREAM OF THE BATHROOM GROUP. PER FBC PL 912.1 | | | | | | 6. THE LAVATORY IN THE BATHROOM SHALL COMPLY WITH FBC | | | PL 416.5 TEMPERED WATER FOR PUBLIC HAND-WASHING | | | FACILITIES. | | | TEMPERED WATER SHALL BE DELIVERED FROM LAVATORIES AND | | | GROUP WASH FIXTURES LOCATED IN PUBLIC TOILET FACILITIES | | | PROVIDED FOR CUSTOMERS, PATRONS AND VISITORS. TEMPERED | | | WATER SHALL BE DELIVERED THROUGH AN APPROVED | | | WATER-TEMPERATURE LIMITING DEVICE THAT CONFORMS TO ASSE | | | 1070 OR CSA B125.3. | | | 607.1.1 TEMPERATURE LIMITING MEANS. | | | A THERMOSTAT CONTROL FOR A WATER HEATER SHALL NOT SERVE | | | AS THE TEMPERATURE LIMITING MEANS FOR THE PURPOSES OF | | | COMPLYING WITH THE REQUIREMENTS OF THIS CODE FOR | | | MAXIMUM ALLOWABLE HOT OR TEMPERED WATER DELIVERY | | | TEMPERATURE AT FIXTURES. | | | | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
2 |
Status |
P |
Date |
2017-05-26 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2017-05-26 |
Time |
13:20 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2017-05-26 |
Time |
13:20 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
Z |
ZONING |
| Rev No |
1 |
Status |
P |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
aaponte |
Date |
2017-05-12 |
Time |
13:29 |
Rev Time |
0.00 |
| Received By |
aaponte |
Date |
2017-05-12 |
Time |
13:29 |
Sent To |
|
|
| Notes |
|
|