Plan Review Details - Permit 17031248
Plan Review Stops For Permit 17031248
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-07-11 Cont ID  
Sent By cthroop Date 2017-07-11 Time 10:36 Rev Time 0.00
Received By cthroop Date 2017-07-11 Time 10:18 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-04-25 Cont ID  
Sent By cthroop Date 2017-04-25 Time 11:32 Rev Time 0.00
Received By cthroop Date 2017-04-25 Time 09:29 Sent To  
Notes
2017-04-25 11:53:54BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. PROVIDE SITE PLAN.
 1A. SHOW BUILDING SETBACKS TO PROPERTY LINES.
 1B. SHOW LOT DRAINAGE.
 2. FOUNDATION.
 2A. PROVIDE DETAIL FOR NEW TO OLD SOG CONNECTION.
 3. PALM BEACH COUNTY IMPACT FEES MAY BE REQUIRED.
 4. ROOFING PERMIT REQUIRED.
 4A. NOA 15-0203.05 IS EXPIRED. PROVIDE CURRENT NOA FOR
 NEW ROOF SYSTEM.
 5. ENERGY SUBMITTAL, FORM 405 SHALL BE REVIEWED AND
 APPROVED BY BUILDER.
 6. TERMITE TREATMENT REQUIRED. POST SOIL TREATMENT
 CERTIFICATION ON-SITE PRIOR TO FOUNDATION INSPECTION.
 7. MECHANICAL PLAN SHALL BE REVIEWED AND APPROVED BY
 DESIGNER.
  
 FBC 107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS
 SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE
 ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE
 AND LOCATION OF NEW CONSTRUCTION AND EXISTING
 STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE
 ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED
 GRADES AND, AS APPLICABLE, FLOOD HAZARD AREAS,
 FLOODWAYS, AND DESIGN FLOOD ELEVATIONS; AND IT SHALL BE
 DRAWN IN ACCORDANCE WITH AN ACCURATE BOUNDARY LINE
 SURVEY.
  
 FBC R401.3 SITE DRAINAGE
 PROVIDE TWO SETS OF A SITE DRAINAGE PLAN SHOWING
 COMPLIANCE WITH FBC R401.3 DRAINAGE.
 SURFACE DRAINAGE SHALL BE DIVERTED TO A STORM SEWER
 CONVEYANCE OR OTHER APPROVED POINT OF COLLECTION THAT
 DOES NOT CREATE A HAZARD.
 LOTS SHALL BE GRADED TO DRAIN SURFACE WATER AWAY FROM
 FOUNDATION WALLS. THE GRADE SHALL FALL A MINIMUM OF 6
 INCHES WITHIN THE FIRST 10 FEET.
 EXCEPTION: WHERE LOT LINES, WALLS, SLOPES OR OTHER
 PHYSICAL BARRIERS PROHIBIT 6 INCHES OF FALL WITHIN 10
 FEET, DRAINS OR SWALES SHALL BE CONSTRUCTED TO ENSURE
 DRAINAGE AWAY FROM THE STRUCTURE.
 IMPERVIOUS SURFACES WITHIN 10 FEET OF THE BUILDING
 FOUNDATION SHALL BE SLOPED A MINIMUM OF
 2 PERCENT AWAY FROM THE BUILDING.
  
 FBC 107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS.
 CONSTRUCTION DOCUMENTS SHALL BE DIMENSIONED AND DRAWN
 UPON SUITABLE MATERIAL. CONSTRUCTION DOCUMENTS SHALL BE
 OF SUFFICIENT CLARITY TO INDICATE THE LOCATION, NATURE
 AND EXTENT OF THE WORK PROPOSED AND SHOW IN DETAIL THAT
 IT WILL CONFORM TO THE PROVISIONS OF THIS CODE AND
 RELEVANT LAWS, ORDINANCES, RULES AND REGULATIONS, AS
 DETERMINED BY THE BUILDING OFFICIAL.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.
  
 FBCE-R101.5.1.1 BUILDING THERMAL ENVELOPE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R402
 SHALL BE SUBMITTED TO THE BUILDING OFFICIAL TO
 DEMONSTRATE CODE COMPLIANCE BY THIS METHOD.
  
 _ OR _
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 R318.1 TERMITE PROTECTION.
 TERMITE PROTECTION SHALL BE PROVIDED BY REGISTERED
 TERMITICIDES, INCLUDING SOIL APPLIED PESTICIDES,
 BAITING SYSTEMS, AND PESTICIDES APPLIED TO WOOD, OR
 OTHER APPROVED METHODS OF TERMITE PROTECTION LABELED
 FOR USE AS A PREVENTATIVE TREATMENT TO NEW
 CONSTRUCTION. SEE SECTION 202, REGISTERED TERMITICIDE.
 UPON COMPLETION OF THE APPLICATION OF THE TERMITE
 PROTECTIVE TREATMENT, A CERTIFICATE OF COMPLIANCE SHALL
 BE ISSUED TO THE BUILDING DEPARTMENT BY THE LICENSED
 PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWING
 STATEMENT: ?THE BUILDING HAS RECEIVED A COMPLETE
 TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES.
 TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS
 ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE
 AND CONSUMER SERVICES.?
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY
 REVIEWED SHEETS DETACHED AND MARK VOID.
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2017-04-06 Cont ID  
Sent By jleahy Date 2017-04-06 Time 16:46 Rev Time 0.00
Received By jleahy Date 2017-04-06 Time 16:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-07-11 Cont ID  
Sent By cthroop Date 2017-07-11 Time 10:35 Rev Time 0.00
Received By cthroop Date 2017-07-05 Time 15:43 Sent To  
Notes
2017-07-06 15:44:01RESUB ROUTED TO HMOSER

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-04-25 Cont ID  
Sent By skennedy Date 2017-04-25 Time 12:46 Rev Time 0.00
Received By skennedy Date 2017-03-31 Time 14:06 Sent To  
Notes
2017-04-03 14:06:43R22

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-09-26 Cont ID  
Sent By cthroop Date 2017-09-26 Time 14:29 Rev Time 0.00
Received By cthroop Date 2017-09-26 Time 14:29 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-04-25 Cont ID  
Sent By cthroop Date 2017-04-25 Time 11:28 Rev Time 0.00
Received By cthroop Date 2017-04-25 Time 09:30 Sent To  
Notes
2017-04-25 11:29:55BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-07-10 Cont ID  
Sent By hmoser Date 2017-07-10 Time 14:59 Rev Time 0.00
Received By hmoser Date 2017-07-10 Time 14:19 Sent To  
Notes
2017-07-10 14:59:47PASS PROVISO
 REFER TO SECTION M1602.2 PROHIBITED SOURCES
 2014 RESIDENTIAL CODE

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-04-25 Cont ID  
Sent By skennedy Date 2017-04-25 Time 12:36 Rev Time 0.00
Received By skennedy Date 2017-04-25 Time 12:36 Sent To  
Notes
2017-04-25 12:46:111ST REVIEW: FBC 2014 5TH ED. RESIDENTIAL
 1ST REVIEW FBC 2014 EXISTING BUILDING
  
 MECHANICAL FAILED
  
 1) SHEET M1 IS NOT SIGNED BY THE IDENTIFIED DESIGNER OF
 RECORD. M GONZALEZ IS LISTED. PLEASE SIGN PER THE
 FOLLOWING SECTION:
 FBC-107.2.1 INFORMATION ON CONSTRUCTION DOCUMENTS. ALL
 INFORMATION, DRAWINGS, SPECIFICATIONS AND ACCOMPANYING
 DATA SHALL BEAR THE NAME AND SIGNATURE OF THE PERSON
 RESPONSIBLE FOR THE DESIGN.
 PLEASE NOTE TOU HAVE PROVIDED A NOTE ON THE EQUIPMENT
 SCHEDULE AS FOLLOWS: "OR EQUIVALENT." IT IS A BEST
 PRACTICE TO REMOVE SUCH NOTES AS THE INSTALLED
 EQUIPMENT MUST BE THE SPECIFIED EQUIPMENT UNLESS
 REVISED. NOTE THE SEER LISTED IS DIFFERENT THAN THE
 SEER LISTED ON THE ENERGY FORM.
  
 2) FORM R405 PROVIDED IS NOT ACCURATELY COMPLETED.
  
 THE SEER LISTED OF 16.00 IS NOT CONSISTENT WITH THE
 SEER LISTED IN THE MECHANICAL EQUIPMENT SCHEDULE OF
 14.00. THE FRONT SHEET OF THE FORM IS MISSING
 INFORMATION AT THE TOP AND IS MISSING THE OWNER'S
 REPERSENTATIVE OR OWNER'S SIGNATURE.
  
 FBCE-101.5.1.1.2 SIMULATED PERFORMANCE ALTERNATIVE.
 AN ACCURATELY COMPLETED RESIDENTIAL BUILDING FORM R405
 (GENERATED BY COMMISSION APPROVED SOFTWARE) SHALL BE
 SUBMITTED TO THE BUILDING OFFICIAL TO DEMONSTRATE CODE
 COMPLIANCE BY SECTION 405.
  
 STEVEN KENNEDY, CBO
 ASSISTANT BUILDING OFFICIAL
 (561) 805-6710
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2017-04-24 Cont ID  
Sent By gjohnson Date 2017-04-24 Time 10:55 Rev Time 0.00
Received By gjohnson Date 2017-04-24 Time 10:38 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2017-07-11 Cont ID  
Sent By cthroop Date 2017-07-11 Time 10:35 Rev Time 0.00
Received By cthroop Date 2017-07-11 Time 10:18 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2017-04-25 Cont ID  
Sent By cthroop Date 2017-04-25 Time 11:30 Rev Time 0.00
Received By cthroop Date 2017-04-25 Time 09:29 Sent To  
Notes
2017-04-25 11:32:18BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 ROOFING PERMIT REQUIRED
  
 1. NOA 15-0203.05 IS EXPIRED. PROVIDE CURRENT NOA FOR
 NEW ROOF SYSTEM.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING SUBMITTALS.

Review Stop Z ZONING
Rev No 1 Status P Date   Cont ID  
Sent By   Date 2017-04-07 Time   Rev Time 0.00
Received By pgreilic Date 2017-04-07 Time 11:39 Sent To  
Notes
2017-04-07 11:39:37PAUL GREILICH, SENIOR PLANNER
 561-822-1443
 [email protected]