| Plan Review Stops For Permit 17031136 |
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-15 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-05-15 |
Time |
12:38 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-05-15 |
Time |
12:38 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
B |
BUILDING (STRUCTURAL) |
| Rev No |
1 |
Status |
P |
Date |
2017-04-04 |
|
|
Cont ID |
|
| Sent By |
shill |
Date |
2017-04-04 |
Time |
14:48 |
Rev Time |
0.00 |
| Received By |
shill |
Date |
2017-04-04 |
Time |
14:48 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
2 |
Status |
P |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-18 |
Time |
11:21 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-18 |
Time |
11:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
E |
ELECTRICAL |
| Rev No |
1 |
Status |
F |
Date |
2017-04-19 |
|
|
Cont ID |
|
| Sent By |
vperez |
Date |
2017-04-19 |
Time |
10:58 |
Rev Time |
0.00 |
| Received By |
vperez |
Date |
2017-04-19 |
Time |
10:58 |
Sent To |
|
|
| Notes |
| 2017-04-19 10:58:52 | PLEASE ADDRESS MECHANICAL FOR AN ELECTRICAL APPROVAL. | | | FBC 107.3.5 | | | | | | V. PEREZ | | | *6717 |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
2 |
Status |
P |
Date |
2017-05-05 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-05-05 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-05-05 |
Time |
12:42 |
Sent To |
|
|
| Notes |
| 2017-05-05 13:10:21 | 2ND REVIEW COMMENTS | | | | | | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. | | | | | | FAILURE TO FOLLOW THESE PROVISO COMMENTS WILL RESULT IN | | | A FAILED FIRE INSPECTION. | | | | | | | | | 1) | | | SHEET 1.1 - THERE IS NO INDICATION OF A FIRE CODE | | | REFERENCE AND/OR COMPLIANCE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | PLEASE ENSURE ALL WORK IS DONE IN COMPLIANCE WITH THE | | | ABOVE NOTED CODE. | | | | | | | | | | | | | | | 2) | | | SHEET 1.1 - THERE ARE INDICATIONS OF WALLS THAT ARE | | | BEING REMOVED AND NEW WALLS INSTALLED (OR A RAISED | | | CEILING). | | | | | | ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND | | | SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY | | | CERTIFIED LIFE SAFETY CONTRACTORS. | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | PLEASE ENSURE COMPLIANCE WITH: | | | | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
FIRE |
FIRE DEPARTMENT |
| Rev No |
1 |
Status |
P |
Date |
2017-04-04 |
|
|
Cont ID |
|
| Sent By |
pleduc |
Date |
2017-04-04 |
Time |
|
Rev Time |
0.00 |
| Received By |
pleduc |
Date |
2017-04-03 |
Time |
11:29 |
Sent To |
|
|
| Notes |
| 2017-04-04 11:12:46 | PLEASE CONSIDER THE FOLLOWING AS PROVISO: | | | | | | THESE PROVISO COMMENTS WILL BE VERIFIED AND CONFIRMED | | | AT THE TIME OF FIRE INSPECTION. | | | | | | FAILURE TO FOLLOW THESE PROVISO COMMENTS WILL RESULT IN | | | A FAILED FIRE INSPECTION. | | | | | | | | | 1) | | | SHEET 1.1 - THERE IS NO INDICATION OF A FIRE CODE | | | REFERENCE AND/OR COMPLIANCE. | | | | | | THE PROPOSED PROJECT SHALL MEET THE REQUIREMENTS OF THE | | | 5TH EDITION OF FLORIDA FIRE PREVENTION CODE INCLUDING | | | THE 2012 EDITION OF NFPA 1 AND NFPA 101 AND ALL OTHER | | | APPLICABLE CODES OR STANDARDS. | | | | | | PLEASE ENSURE ALL WORK IS DONE IN COMPLIANCE WITH THE | | | ABOVE NOTED CODE. | | | | | | | | | | | | | | | 2) | | | SHEET 1.1 - THERE ARE INDICATIONS OF WALLS THAT ARE | | | BEING REMOVED AND NEW WALLS INSTALLED (OR A RAISED | | | CEILING). | | | | | | ANY REMOVAL AND/OR CONSTRUCTION OF WALLS AND /OR | | | CEILINGS REQUIRE AN EVALUATION OF THE FIRE ALARM AND | | | SPRINKLER SYSTEM FOR CODE COVERAGE AND COMPLIANCE BY | | | CERTIFIED LIFE SAFETY CONTRACTORS. | | | THE LIFE SAFETY SYSTEMS, FIRE ALARM AND/OR FIRE | | | SPRINKLER SHALL REMAIN ACTIVE THROUGHOUT THE | | | CONSTRUCTION PERIOD. | | | ANY AND ALL WORK ON THE FIRE ALARM AND FIRE SPRINKLER | | | SYSTEMS SHALL BE DONE UNDER SEPARATE SHOP DRAWINGS AND | | | BY CERTIFIED LIFE SAFETY CONTRACTORS. | | | | | | PLEASE ENSURE COMPLIANCE WITH: | | | | | | FIRE SPRINKLER WORK SHALL COMPLY WITH THE REQUIREMENTS | | | OF NFPA 13, 2010 EDITION. | | | FIRE ALARM WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 72, 2010 EDITION. | | | CONSTRUCTION WORK SHALL COMPLY WITH THE REQUIREMENTS OF | | | NFPA 241, 2009 EDITION. | | | | | | | | | PETER LEDUC | | | FIRE MARSHAL | | | 561-804-4709 | | | [email protected] | | | |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
2 |
Status |
N |
Date |
2017-05-18 |
|
|
Cont ID |
|
| Sent By |
jleahy |
Date |
2017-05-18 |
Time |
11:22 |
Rev Time |
0.00 |
| Received By |
jleahy |
Date |
2017-05-04 |
Time |
16:03 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
I |
INCOMING/PROCESSING |
| Rev No |
1 |
Status |
N |
Date |
2017-04-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-21 |
Time |
12:54 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-03-29 |
Time |
10:21 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
2 |
Status |
P |
Date |
2017-05-08 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-05-08 |
Time |
17:33 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-05-08 |
Time |
17:33 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
M |
MECHANICAL (A/C) |
| Rev No |
1 |
Status |
F |
Date |
2017-04-07 |
|
|
Cont ID |
|
| Sent By |
ccole |
Date |
2017-04-07 |
Time |
10:09 |
Rev Time |
0.00 |
| Received By |
ccole |
Date |
2017-04-07 |
Time |
10:09 |
Sent To |
|
|
| Notes |
| 2017-04-07 10:23:48 | 1ST REVIEW FBC-2014 MECHANICAL | | | PERMIT #17031136 | | | 4/7/17 | | | | | | 1) SHEET 2.1: THE LEGEND INDICATES A 50 CFM KITCHEN | | | EXHAUST FAN THAT IS NOT SHOWN ON THE PLAN. PLEASE NOTE | | | THAT A MINIMUM 100 CFMS IS REQUIRED PER TABLE 403.3 IF | | | THE EXHAUST IS OPERATED INTERMITTENTLY. | | | | | | 2) SHOW THE LOCATIONS OF THE COOKTOP EXHAUST FAN AND | | | EXHAUST DUCT AND SUBMIT MANUFACTURER'S SPECIFICATIONS- | | | SEE SECTION 505.2. | | | | | | 3) PROVIDE THE CFMS AT EACH NEW SUPPLY DIFFUSER. | | | | | | 4) PROVIDE EXHAUST FOR THE NEW DRYER. SHOW THE TYPE AND | | | SIZE OF EXHAUST DUCT, THE DUCT RUN AND TERMINATION | | | LOCATION, OR THE POINT OF CONNECTION TO THE EXISTING | | | EXHAUST RISER. ADVISORY: EXHAUST DUCTS SHALL NOT EXTEND | | | INTO OR RUN THROUGH PLENUMS- SECTION 504.4. | | | | | | CHRISTOPHER L. COLE | | | MECHANICAL PLANS EXAMINER | | | 401 CLEMATIS STREET | | | WEST PALM BEACH FL 33401 | | | 561-805-6719 | | | [email protected] | | | |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
2 |
Status |
P |
Date |
2017-05-12 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-05-12 |
Time |
11:50 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-05-12 |
Time |
09:05 |
Sent To |
|
|
| Notes |
|
|
| Review Stop |
P |
PLUMBING |
| Rev No |
1 |
Status |
F |
Date |
2017-04-21 |
|
|
Cont ID |
|
| Sent By |
gjohnson |
Date |
2017-04-21 |
Time |
12:31 |
Rev Time |
0.00 |
| Received By |
gjohnson |
Date |
2017-04-21 |
Time |
12:18 |
Sent To |
|
|
| Notes |
| 2017-04-21 12:53:11 | 1ST REVIEW | | | | | | GEORGE JOHNSON | | | PLUMBING PLANS EXAMINER LL | | | CITY OF WEST PALM BEACH | | | DEVELOPMENT SERVICES | | | BUILDING DIVISION | | | 561-805-6711 | | | [email protected] | | | | | | PLUMBING COMMENTS: | | | | | | 1. PROVIDE RISER DIAGRAM FOR NEW WASHING MACHINE . PER | | | WPB AMEND TO FBC 107.3.5.1.3(13) | | | | | | 2. WASHING MACHINE BRANCH DRAIN SHALL BE MIN OF 3" PER | | | FBC PL 406.2 | | | | | | 3. THE WASHING MACHINE DRAIN SHALL NOT TIE INTO THE WET | | | VENT OF THE BATHROOM GROUP, IT SHALL TIE IN DOWN STREAM | | | OF BATHROOM GROUP. PER FBC PL 912.1 | | | | | | | | | | | | FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT | | | THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL | | | COMMENTS. | | | | | | WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES | | | AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW | | | COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE | | | AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE | | | THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW. | | | |
|
|