Plan Review Details - Permit 17030959
Plan Review Stops For Permit 17030959
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2017-07-25 Cont ID  
Sent By cthroop Date 2017-07-25 Time 10:58 Rev Time 0.00
Received By cthroop Date 2017-07-25 Time 07:31 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2017-05-05 Cont ID  
Sent By cthroop Date 2017-05-05 Time 14:14 Rev Time 0.00
Received By cthroop Date 2017-05-05 Time 09:19 Sent To M
Notes
2017-05-05 14:30:58BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1. ROOFING PERMIT REQUIRED.
 2. PROVIDE NOA'S/PRODUCT APPROVALS FOR NEW ROOF SYSTEM
 COMPONENTS.
 3. PALM BEACH COUNTY IMPACT FEES REQUIRED.
 4. NOA'S LISTED ON WINDOW AND DOOR SCHEDULE DO NOT
 MATCH PRODUCT APPROVALS SUBMITTED. CORRECT SCHEDULES ON
 SUBMITTED PLANS.
 5. PROVIDE NOA'S FOR WINDOW MULLIONS.
 6. PROVIDE DEMENSIONS FOR LANDING AT BOTTOM OF STAIRS.
 7. GUARDS AT STAIRS AND BALCONY - A. HEIGHT - 42" B.
 MAX OPENING - 4".
 8. TWO DIFFERENT PLAN PAGES ARE LABELED S-2. PLEASE
 CLARIFY.
  
 FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 SPECIFICALLY, PROVIDE ROOFING, WINDOW, AND DOOR
 SUBMITTALS.
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
 R311.7 STAIRWAYS.
  
 R311.7.6 LANDINGS FOR STAIRWAYS.
 THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM
 OF EACH STAIRWAY. THE MINIMUM WIDTH PERPENDICULAR TO
 THE DIRECTION OF TRAVEL SHALL BE NO LESS THAN THE WIDTH
 OF THE FLIGHT SERVED. LANDINGS OF SHAPES OTHER THAN
 SQUARE OR RECTANGULAR SHALL BE PERMITTED PROVIDED THE
 DEPTH AT THE WALK LINE AND THE TOTAL AREA IS NOT LESS
 THAN THAT OF A QUARTER CIRCLE WITH A RADIUS EQUAL TO
 THE REQUIRED LANDING WIDTH. WHERE THE STAIRWAY HAS A
 STRAIGHT RUN, THE MINIMUM DEPTH IN THE DIRECTION OF
 TRAVEL SHALL BE NOT LESS THAN 36 INCHES (914 MM).
  
 R311.7.8 HANDRAILS.
 HANDRAILS SHALL BE PROVIDED ON AT LEAST ONE SIDE OF
 EACH CONTINUOUS RUN OF TREADS OR FLIGHT WITH FOUR OR
 MORE RISERS. R311.7.8.1 HEIGHT.
 HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED
 PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF
 RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM)
 AND NOT MORE THAN 38 INCHES (965 MM).
  
 SECTION 1013 GUARDS
  
 1013.2 WHERE REQUIRED.
 GUARDS SHALL BE LOCATED ALONG OPEN-SIDED WALKING
 SURFACES, INCLUDING MEZZANINES, EQUIPMENT PLATFORMS,
 STAIRS, RAMPS AND LANDINGS THAT ARE LOCATED MORE THAN
 30 INCHES (762 MM) MEASURED VERTICALLY TO THE FLOOR OR
 GRADE BELOW AT ANY POINT WITHIN 36 INCHES (914 MM)
 HORIZONTALLY TO THE EDGE OF THE OPEN SIDE. GUARDS SHALL
 BE ADEQUATE IN STRENGTH AND ATTACHMENT IN ACCORDANCE
 WITH SECTION 1607.8.
  
 1013.3 HEIGHT.
 REQUIRED GUARDS SHALL NOT BE LESS THAN 42 INCHES (1067
 MM) HIGH, MEASURED VERTICALLY AS FOLLOWS:
  
 1. FROM THE ADJACENT WALKING SURFACES;
  
 2. ON STAIRS, FROM THE LINE CONNECTING THE LEADING
 EDGES OF THE TREAD NOSINGS; AND
  
 3. ON RAMPS, FROM THE RAMP SURFACE AT THE GUARD.
  
 1013.4 OPENING LIMITATIONS.
 REQUIRED GUARDS SHALL NOT HAVE OPENINGS WHICH ALLOW
 PASSAGE OF A SPHERE 4 INCHES (102 MM) IN DIAMETER FROM
 THE WALKING SURFACE TO THE REQUIRED GUARD HEIGHT.
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2017-07-21 Cont ID  
Sent By jleahy Date 2017-07-21 Time 07:16 Rev Time 0.00
Received By jleahy Date 2017-07-21 Time 07:16 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2017-04-04 Cont ID  
Sent By jleahy Date 2017-04-04 Time 11:17 Rev Time 0.00
Received By jleahy Date 2017-04-04 Time 11:17 Sent To  
Notes
2017-04-04 11:20:40FLORIDA BUILDING CODE 2014 5TH EDITION
 FLORIDA BUILDING CODE 2014 5TH ED. RESIDENTIAL
 NFPA 70 2011 EDITION
  
 LOAD CALCULATION FOR PANEL "B" SHOWS 68 AMPERS WIRE
 FROM MAIN IS ONLY #6, SOME OF THE NOTATIONS SHOW 100A
 PANEL AND SOME SHOW 60A
 PLEASE CLARIFY
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 BN1165, BU1753, PX163
 561-805-6713
  
  

Review Stop HIST HISTORICAL
Rev No 2 Status P Date 2017-07-25 Cont ID  
Sent By fmittner Date 2017-07-25 Time 13:20 Rev Time 0.00
Received By fmittner Date 2017-07-25 Time 13:20 Sent To  
Notes
***NONE***

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2017-04-28 Cont ID  
Sent By fmittner Date 2017-04-28 Time 15:53 Rev Time 0.00
Received By fmittner Date 2017-04-28 Time 15:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2017-08-08 Cont ID  
Sent By tklarge Date 2017-08-08 Time 11:41 Rev Time 0.00
Received By tklarge Date 2017-08-08 Time 11:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2017-07-31 Cont ID  
Sent By hmoser Date 2017-07-31 Time 14:50 Rev Time 0.00
Received By hmoser Date 2017-07-05 Time 15:23 Sent To  
Notes
2017-07-06 15:23:29R34

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2017-05-31 Cont ID  
Sent By cthroop Date 2017-05-31 Time 14:06 Rev Time 0.00
Received By cthroop Date 2017-05-30 Time 13:17 Sent To  
Notes
2017-05-31 13:17:50IMPACT FEES ROUTED TO CTHROOP

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2017-05-10 Cont ID  
Sent By hmoser Date 2017-05-10 Time 09:26 Rev Time 0.00
Received By hmoser Date 2017-03-23 Time 13:21 Sent To  
Notes
2017-03-24 13:21:02R24

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2017-05-31 Cont ID  
Sent By cthroop Date 2017-05-31 Time 14:07 Rev Time 0.00
Received By cthroop Date 2017-05-31 Time 14:06 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2017-05-05 Cont ID  
Sent By cthroop Date 2017-05-05 Time 14:13 Rev Time 0.00
Received By cthroop Date 2017-05-05 Time 09:19 Sent To  
Notes
2017-05-05 14:16:19BUILDING PLAN REVIEW
 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1
 ADMINISTRATION
  
 CHRISTOPHER S. THROOP, C.B.O.
 PLANS EXAMINER, PX3169
 CONSTRUCTION SERVICES DIVISION
 TEL: 561-805-6726
 FAX: 561-805-6676
  
 1ST REVIEW
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 BEFORE A PERMIT TO CONSTRUCT CAN BE ISSUED, IMPACT FEES
 MUST BE PAID TO PALM BEACH COUNTY. UPON APPROVAL, ONE
 SET OF PLANS SHALL BE SIGNED OUT AND SUBMITTED TO PALM
 BEACH COUNTY FOR AN IMPACT FEE REVIEW. THE PLANS WITH
 THE IMPACT FEE STAMP AND A COPY OF THE PAID RECEIPT
 MUST BE RETURNED TO THE CITY BUILDING DEPARTMENT BEFORE
 THE BUILDING PERMIT CAN BE ISSUED. FOR INFORMATION CALL
 PALM BEACH COUNTY IMPACT FEES AT (561) 233-5025.
  
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2017-07-31 Cont ID  
Sent By hmoser Date 2017-07-31 Time 14:50 Rev Time 0.00
Received By hmoser Date 2017-07-31 Time 14:44 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2017-05-10 Cont ID  
Sent By hmoser Date 2017-05-10 Time 09:26 Rev Time 0.00
Received By hmoser Date 2017-05-10 Time 08:01 Sent To  
Notes
2017-05-10 09:26:09PLAN DENIED
 1) PROVIDE TYPE OF EQUIPMENT ON EQUIPMENT SCHEDULE
 PER SECTION 107 FBC
 2) PROVIDE CONDENSER TIE DOWN DETAIL. PER SECTION
 301.15 WIND FBC (M) 2014
 3) MECHANICAL NOTE # 1 REFERS TO 2010 CODES.
 WE ARE IN 2014 CODES.
 4) MECHANICAL NOTE # 5 STATES FLEX DUCT SHALL
 BE R-6. REFER TO SECTION R403.2.1 FLORIDA ENERGY
 CODE 2014 FLEX DUCT IN ATTIC SHALL BE A
 MINIMUM OF R-8.
  
 PLAN REVIEW BY HAROLD MOSER
 [email protected]
 OFFICE 561-805-6732
 FAX 561-805-6676

Review Stop P PLUMBING
Rev No 3 Status P Date 2017-08-08 Cont ID  
Sent By tklarge Date 2017-08-08 Time 11:38 Rev Time 0.00
Received By tklarge Date 2017-08-08 Time 11:38 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2017-07-21 Cont ID  
Sent By gjohnson Date 2017-07-21 Time 12:27 Rev Time 0.00
Received By gjohnson Date 2017-07-21 Time 11:34 Sent To  
Notes
2017-07-21 12:34:192ND REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. THE 3" SOIL STACK FROM 2ND FLOOR SHALL TIE IN
 DOWNSTREAM OF THE FIST FLOOR BATHROOM GROUP. PER FBC
 RES P3108.1
  
 PREVIOUS COMMENT HAS NOT COMPLIED 4. PROVIDE
 MANUFACTURES SPES FOR TANKLESS WATER HEATER. WPB AMEND
 TO FBC 107.2.1
  
  
 FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT
 THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL
 COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2017-04-14 Cont ID  
Sent By gjohnson Date 2017-04-14 Time 12:43 Rev Time 0.00
Received By gjohnson Date 2017-04-14 Time 11:05 Sent To  
Notes
2017-04-14 13:29:551ST REVIEW
  
 GEORGE JOHNSON
 PLUMBING PLANS EXAMINER LL
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES
 BUILDING DIVISION
 561-805-6711
 [email protected]
  
 PLUMBING COMMENTS:
  
 1. TOILET AND SHOWER DOWN STAIRS ARE NOT VENTED SHOULD
 BE VENTED TOGETHER WITH LAV. PER FBC PL 901.2.1\
  
 2. CLEAN OUTS ARE REQUIRED AT THE BASE OF SOIL STACKS.
 FBC PL 708.3.4
  
 3. ONE VENT SHALL TERMINATE OUTDOORS. PER FBC PL 904.3
  
 4. PROVIDE MANUFACTURES SPES FOR TANKLESS WATER HEATER.
 WPB AMEND TO FBC 107.2.1
  
  
 FYI A COMPLETE AND THOROUGH REVIEW CANNOT BE DONE AT
 THIS TIME. UPON RESUBMITTAL THERE MAYBE ADDITIONAL
 COMMENTS.
  
 WHEN RESUBMITTING PLANS, REMOVE AND REPLACE ANY PAGES
 AS NECESSARY. A NARRATIVE LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER WITH A DESCRIPTION OF THE CHANGES MADE
 AND IDENTIFYING THE SHEET OR SPECIFICATION PAGE WHERE
 THE CHANGE CAN BE FOUND WILL HELP EXPEDITE THE REVIEW.
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status P Date 2017-07-25 Cont ID  
Sent By cthroop Date 2017-07-25 Time 11:02 Rev Time 0.00
Received By cthroop Date 2017-07-25 Time 11:02 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2017-07-25 Cont ID  
Sent By fmittner Date 2017-07-25 Time 13:21 Rev Time 0.00
Received By fmittner Date 2017-07-25 Time 13:21 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2017-04-28 Cont ID  
Sent By fmittner Date 2017-04-28 Time 15:53 Rev Time 0.00
Received By fmittner Date 2017-04-28 Time 15:53 Sent To  
Notes
***NONE***