| 2017-04-11 08:35:09 | BUILDING PLAN REVIEW |
| | 2014 FLORIDA BUILDING CODE W/2010 WEST PALM BEACH |
| | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1 |
| | ADMINISTRATION |
| | |
| | CHRISTOPHER S. THROOP, C.B.O. |
| | PLANS EXAMINER, PX3169 |
| | CONSTRUCTION SERVICES DIVISION |
| | TEL: 561-805-6726 |
| | FAX: 561-805-6676 |
| | |
| | 1ST REVIEW |
| | RESULTS: DENIED |
| | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| | |
| | 1. PROVIDE SITE PLAN WITH LOCATION OF DECK AND SETBACKS |
| | TO PROPERTY LINES. |
| | FBC 107.3.5 MINIMUM PLAN REVIEW CRITERIA FOR BUILDINGS. |
| | THE EXAMINATION OF THE DOCUMENTS BY THE BUILDING |
| | OFFICIAL SHALL INCLUDE THE FOLLOWING MINIMUM CRITERIA |
| | AND DOCUMENTS: A FLOOR PLAN; SITE PLAN; FOUNDATION |
| | PLAN; |
| | |
| | 2. PROVIDE LANDINGS AT STAIRS. |
| | R311.7.6 LANDINGS FOR STAIRWAYS. |
| | THERE SHALL BE A FLOOR OR LANDING AT THE TOP AND BOTTOM |
| | OF EACH STAIRWAY. THE MINIMUM WIDTH PERPENDICULAR TO |
| | THE DIRECTION OF TRAVEL SHALL BE NO LESS THAN THE WIDTH |
| | OF THE FLIGHT SERVED. LANDINGS OF SHAPES OTHER THAN |
| | SQUARE OR RECTANGULAR SHALL BE PERMITTED PROVIDED THE |
| | DEPTH AT THE WALK LINE AND THE TOTAL AREA IS NOT LESS |
| | THAN THAT OF A QUARTER CIRCLE WITH A RADIUS EQUAL TO |
| | THE REQUIRED LANDING WIDTH. WHERE THE STAIRWAY HAS A |
| | STRAIGHT RUN, THE MINIMUM DEPTH IN THE DIRECTION OF |
| | TRAVEL SHALL BE NOT LESS THAN 36 INCHES (914 MM). |
| | |
| | 3. FOUNDATION PLAN AND FRAMING PLAN ON SHEET S-2 |
| | REFERENCE PLAN PAGE S-3. NO S-3 SUBMITTED. PLEASE |
| | CLARIFY. |
| | |
| | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE |
| | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY |
| | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT |
| | CORRECTED PAGES INTO SUBMITTAL AND LEAVE THE PREVIOUSLY |
| | REVIEWED SHEETS DETACHED AND MARK VOID. |
| | |